Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010121304538Control Unit · faultyRECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO RECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO SUCCESSFUL RESET AFTER REMOVAL & CLEANING OF PCA CONNECTORS; REMOVE INSPECT AND REPLACE IF NECESDR UALA2010121304548Connector · faultyACARS NO COMM MOST OF FLIGHT. IAW FIM 23-25-00-101 PARA D(B)UP TO STEP 4 ITEM REPLACED. DID FIND CONNECTORS LOOSE FROM SHIELDS AT HIGH POWER RELAY D2673, D2675. HIGH GAIN SYS LOGS ON FOR APPROX 90 SECONDS THEN SEARCHES AGAIN. CYCLE RESTARTS. HIGH PWR RELAY, PSDR UALA2010121004512Connector · dirtyEICAS MESSAGE REVERSER ISOLATION VALVE DISPLAYED AND REVERSER ISOLATION LIGHT ILLUMINATED DURING REVERSE THRUST. REACTIVATED REVERSER. CLEANED CONNECTOR AT REVERSER ISOLATION VALVE. CHECKED OPERATION SEVERAL TIMES. REVERSER OPERATION NORMAL, NO FURTHER MESSAGSDR UALA2010120904495Indicator · faultyFIRST OFFICER`S VSI OFF FLAG NEVER COMES IN VIEW. REPLACED VERTICAL SPEED INDICATOR IAW AMM. VSI TESTED SATISFACTORY.SDR UALA2010120904497Circuit Card · faultyLT ENGINE FIRE LOOP 2 DISPLAYED ON STATUS. FIRE TEST NO HELP. WON'T ERASE. REPLACED CARDS M684 AND M10274, LOOP RESISTANCE FROM CARD 684 PIN 19-20 1450 OHMS.SDR UALA2010121004517Lens · missingCEILING AISLE EMERGENCY LIGHT MISSING LENS AT LT ROW 37. FOUND AND REINSTALLED LENS.SDR UALA20101209001Wire · brokenCEILING AISLE EMERGENCY LIGHTS INOP AT SEATS 7AB AND 8KJ. REPAIRED BROKEN WIRE AT SEATS 7AB AND RESEATED LOOSE PIN AT CONNECTOR AT SEAT 8KJ, OP CHECKS GOOD.SDR UALA2010121004516Wire Harness · damagedEEL LIGHT INOP AT SEAT 6KJ. RELAMPED, BUT NO HELP. FOUND PIN PUSHED BACK AND RESECURED PIN BACK IN PLACE. OP CKD GOOD.SDR UALA2010120804484Line · leakingLEFT HYD SYS QTY INDICATES .68 RF ON STATUS AND EICAS PGS. FOUND LT SYS HYD QTY AT .40, SERVICED LT SYS TO FULL. FOUND EVIDENCE OF LARGE HYD LEAK IN TAIL. SUSPECT LT SYS RUDDER PCU OR LINE TO IT.SDR UALA2010120804487Control Unit · faultyRIGHT AND LEFT UTILITY BUSSES WILL NOT COME ON LINE AND A-C WILL NOT TAKE GROUND POWER. REPLACED BUSS POWER CONTROL UNIT IAW MM. OPS CKS NORMAL. BOTH UTILITY BUSSES ON LINE AND A-C WILL ACCEPT GROUND POWER.SDR UALA2010120904490Starter · faultyCREW REPORTS NR1 ENG REACHED 21P PERCENT N2 THEN ROLLED BACK TO 5 PERCENT. ABORTED START ATTEMPT, ENG SPOOLED DOWN TO 0 AND START VALVE LIGHT REMAINED ON. REPLACED LT ENG STARTER IAW MM. REPLACED LT ENG STARTER CONTROL VALVE. OPS CHECK NORMAL.SDR DALA1050830186Connector · looseEMERGENCY LIGHTS AT SEAT 25GF ARE INOPERATIVE. MX FOUND A CONNECTOR LOOSE AND RESEATED THE PIN. SYS OPS IS NORMAL.SDR UALA2010120604475Battery Pack · inoperativeEMERGENCY LIGHTS FLICKER. REPLACED BATTERY PACK.SDR UALA2010120604461Battery · faultyAFT RT EMERGENCY LIGHT FLOOR STRIP AND AFT GALLEY FLOOR STRIP ARE DIM WHEN SYSTEM TURNED ON. REPLACED BATTERY, TESTS GOOD.SDR DALA1050551201Wire · brokenEMERGENCY LIGHTS AT SEAT 38AB ARE INOPERATIVE. MX FOUND A BROKEN WIRE AND REPLACED. SYS OPS IS NORMAL.SDR DALA1050571201Wire Harness · brokenEMERGENCY LIGHTS AT 29AB ARE INOPERATIVE. MX FOUND A HARNESS WIRE BROKEN AND REPLACED. SYS OPS IS NORMAL.SDR UALA2010120204430Computer · faultyNUMEROUS EICAS WARNINGS AT TAKEOFF. REPLACED RT EICAS COMPUTER & LOADED OPS & OPC SOFTWARE. ACP EICAS BITE SEVERAL TIMES OK.SDR CA101202001Transceiver · damaged(CAN) OVERWEIGHT LANDING ON ACCOUNT OF AIRBORNE RETURN DUE TO WEATHER RADAR FAILURE, APPROXIMATE LANDING WEIGHT 152.0. CREW REQUESTED CFR TO BE ON STANDBY. FOUND BADLY DAMAGED PIN ON TRANSCEIVER (PIN2 ON C CONNECTOR) WX TRANSCEIVER REPLACED AS PER AM 34-43-0SDR DALA1034491200Wire · brokenSEAT MOUNTED EMERGENCY PATH LIGHTS AT 19AB ARE INOPERATIVE. MX REPAIRED A BROKEN WIRE. SYS OPS IS NORMAL.SDR UALA2010120104421Satcom · inoperativeSATCOM INOPERATIVE. RESET, NO HELP. SATCOM MENU NOT AVAILABLE ON CDU. HIGH AND LOW GAIN NOT AVAILABLE. REPLACED SATELLITE DATA UNIT PER MM. OPS CHECKED NORMAL.SDR UALA2010112904363Starter · sparksRAMP REPORTED SPARKING DURING NR 2 ENG START MOTORING. START ABORTED. REPLACED STARTER AND START VALVE.SDR UALA2010112904352Valve · faulty'L ENG HPSOV' UPPER EICAS MSG WITH LEFT ENG BLEED SELECTED OFF. MSG GOES AWAY WITH WHEN BLEED SELECTED ON. REPLACED L HPSOV, NO HELP. AFTER SEVERAL CYCLES WITH ENG RUNNING BLEED SWITCH ON NO DUCT PSI ALSO BLEED SWITCH OFF LIGHT ILLUMINATED.SDR DALA1034300171Power Supply · inoperativeEMERGENCY LIGHTS AT SEATS 24AB/GF TO 31AB/GF ARE INOPERATIVE. MX REPLACED SEAT 24AB M9009 POWER SUPPLY IAW AMM. SYS OPS IS NORMAL.SDR UALA2010112904350Valve · faultyRT ENG (BLEED) OFF LIGHT ON AND RT ENG BLEED OFF EICAS MESSAGE, WIT RUNNING, ENG BLEED SWITCH ON, LT AND RT ISOLATION VALVES CLOSED, AC PACK SELECTED ON, AND DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE. REPLACED RT ENG PRSOV. OPS NORMAL.SDR UALA2010112904351Controller · faultyNR 2 ENGINE BLEED INOP WITH ENGINE BLEED SWITCH ON. REPLACED HIGH STAGE REGULATOR AND CONTROLLER AND HIGH STAGE VALVE. OPS NORMAL.SDR UALA2010112904368Skin · damagedLARGE FASTENER MISSING FROM INBD SIDE NR 2 ENGINE PYLON, HOLE IS JUST IN FRONT OF PANEL 447ELX. BOLT IS THE FILLER FOR THE BOOTSTRAP SLING. NOT STRUCTURAL. TEMPORARY REPAIR WITH TAPE. REPLACED IN 5 CYCLES. SEE SERVICE TIP 54-52-01. IPC REF 54-51-57 ITEM 8SDR UALA2010112904356Fire Detector · out of limitsLEFT ENG FIRE LP2 STATUS MSG. ACCOMPLISHED FIM. REPLACED CARD FILE M682 AND SWAPPED AFOLTS NR 1 WITH NR 2, NO HELP. REINSTALLED CARD TO ORIGINAL POS, FOUND DETECTOR TS681 OUT OF LIMITS PER FIM. ACCOMPLISHED CARD FILE REPLACEMENT IAW MM.SDR UALA2010112904357Circuit Card · failedNR 2 ENG OVERHEAT LP2 AND OVERHEAT LP1 STATUS MESSAGE DISPLAYED LWR EICAS AFTER SWAPPING AFLOTS NR 1 AND NR 2 CARD PER FIM TO AID IN NR 1 ENG FIRE LP2 STATUS MSG. REPLACED NR 2 ENGINE AFOLTS CARD M10274 IAW MM, OP CHK GOOD.SDR 2010F00245Pump · failedPITCH ENHACEMENT SYS, HYD POWER TRANSFER UNIT FAILURE/RUPTURE. WHILE TESTING SPOILERS, AILERONS AND FLAPS A LARGE HYD LEAK WAS NOTICED FROM THE HORIZ STAB COMPARTMENT. CONDITIONS IMEDIATLY PRIOR TO SHUTDOWN OF HYD; LT HYD PUMP ON(QYT 1.4), THEN RT HYD PUMP ONSDR UALA2010112304330Fan · faultyFWD EQ SUP FAN 1 STATUS MESSAGE. REPLACED FAN, NO HELP. FAN RUNS FOR 6-7 MINUTES AND STOPS. REPLACED VIBRATION MONITOR PER AMM, NO HELP. REPLACED FAN AGAIN. OPERATIONS NORMAL.SDR UALA2010112304333Servo · failed2 YAW DAMPER DISPLAYED ON EICAS AND YAW DAMP INOP LIGHT ILLUMINATED RIGHT AFTER TAKEOFF. TESTED RIGHT YAW DAMPER. TEST FAILED FAULTING THE RIGHT YAW DAMP ACTUATOR. LEFT YAW DAMPER OPS NORMAL PER MM, FAILED RT YAW DAMPER ACTUATOR. REPLACED RT YAW DAMPER SERSDR UALA2010112404343Controller · failedNR 1 ENGINE HPC FAILED TEST ON HEALTH CHECK. REPLACED NR 1 ENGINE HPC, IAW AMM.SDR UALA2010112404344Connector · dirtyEMERGENCY LIGHT CHECK FAILED STEP C-62 AT DOOR 2 LEFT. FOUND CONNECTORS DIRTY ON PROX BOX ELEX UNIT AND CLEANED. OPS CHECKS GOOD.SDR UALA2010112404342Indicator · unknownFQIS HOT SHORT PROTECTOR WR. INSTALLED FQIS HOT SHORT PROTECTOR.SDR DALA1033811200Engine · failedAPPROX 400 FT AGL AND 190 KIAS APPROX, A LOUD BANG FROM THE LT ENGINE. RPM ROLLED BACK TO NEAR ZERO. ENGINE LT SHUTDOWN IAW CHECK LIST. R & R NR1 ENG IAW TRANS 1T148AD. OPS AND LEAK CK OK. ACFT OK FOR SERVICE.SDR UALA2010112204296Priority Valve · faultyRIGHT ENG PRV LIGHT MOMENTARILY ON TAKEOFF ROLL AND TWICE IN DESCENT WITH REDUCED POWER. REPLACED RT ENG PRV AS PER MM. ALL OPS AND IND NORMAL. PROBLEM RECURRED ON NEXT SEGMENT. REPLACED PRV NR 2 ENGINE IAW AMM. RAN ENGINE FOUND LIGHT FOR ENGINE STILL FLISDR UALA2010112204297Controller · faultyPRIORITY VALVE EICAS MESSAGE CAME ON AT 1000 FT & WENT OUT AFTER 30 SEC AND REPEATED THEN STAYED OUT. REPLACED PRV CONTROLLER PER MM. ACCOMPLISHED ENG HIGH PWR RUN. BLEED COMES ON MOMENTARILY AT 50 PERCENT N1.SDR UALA2010112204306Amplifier · inoperativeSATCOM HI GAIN INOPERATIVE. AMPLIFIER FOUND DEFECTIVE. REPLACED HIGH POWER AMPLIFIER.SDR UALA2010112204309Power Supply · failedPASSENGER REPORTED EMERGENCY LIGHTS BY DOOR 2L FLASHED ON AND OFF MOMENTARILY DURING FLIGHT. MAINT TEXT: EMERGENCY LIGHTS ON, WITHIN 20 TO 30 SECONDS SEATS 19AB THRU 23AB GO OFF, ALONG WITH OVERHEAD EXIT AISLE LIGHT AT SEAT 19AB. REPLACED PWR SUPPLY, OPS GOOSDR CA101122012Shutoff Valve · leaking(CAN) ELEC FLAP/SLAT MESSAGE AT CRUISE. DUE TO CTR HYD LEAK. FLAP/SLAT HYD SHUTOFF VALVE MODULE REPLACED AS PER AMM 29-11-00/201. LEAK CHECK AND FLT CONT OPS CHK, OK. MODULE INSTALLED DATE: 2004-01-13 OVERWEIGHT LANDING ACCOUNT OF MECHANICAL DIVERSION DUE SDR UALA2010111804271Actuator · faultyAPU DOOR EICAS MESSAGE DISPLAYED ON GROUND. NOT RESETABLE. SEVERAL DOOR FUNCTION PERF AND ECU RESET, NO HELP. BITE CHK EICAS FOR MSG'S. REPLACED INLET DOOR ACTUATOR. OPS CHECKS GOOD.SDR UALA2010111704255Battery Pack · inoperativeEMERGENCY CEILING LIGHTS ON THE LEFT SIDE ROWS 19JK THRU 22JK AND EMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1209 DO NOT OPERATE. REPLACED EMERGENCY LIGHT BATTERY PACK AT M1209 POWER SUPPLY PER MM. OPS CHECKS GOOD.SDR UALA2010111804263Battery Pack · inoperativeEXTERIOR EMERGENCY LITES AFT OF RT WING WHICH OPERATE VIA M733 EMERGENCY LIGHTS BATTERY PACK DO NOT ILLUMINATE WHEN TESTED. REPLACED AND OPS CHECKED THE M733 EMERGENCY LIGHT BATTERY ASSEMBLY PER MM. INSPECTED BY QC STAMP NR 822. OPS CHECKED GOOD. PEMCO NR SDR UALA2010111704262Actuator · faultyTEMP UNCONTROLLABLE ALL CABINS AND CP. ALL TEMP CONTROLS FULL COLD OR BOTH PACKS STB C TEMPS 75. ZONE TEMP BITE OK. FOUND RT PACK RAM AIR EXHAUST DOOR ACTUATOR INOP. DOOR MOVES BY ITSELF. A ACTUATOR NO STOCK FRA. REMOVED EXHAUST DOOR PER CDL. DOOR AND ACSDR HALA2010111500537Control Panel · malfunctionedETOPS SIGNIFICANT SYS - LT VOR DME INOP. REPLACED LT VOR/DME CONTROL PANEL IAW AMM 34-51-02, GND CHECK OK.SDR UALA2010111604240Floorbeam · crackedBS 770, MID GALLEY FLOOR CENTER RIGHT TRANSITION FLOORBEAM CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED TRANSITION BEAM IAW SRM, LOCATED, DRILLED AND DEBURRED NEW BEAM P/N STA 770 MID GALLEY FLOOR. INSTALLED NEW FLOORBEAM IAW SRM.SDR UALA2010111504230Oven · smokeWARMING OVEN NR W13 SMOKES AND SMELLS. REPLACED WARMING OVEN R13. OPS NORMAL.SDR UALA2010111504207Battery Pack · inoperativeEMERGENCY LIGHT INOP FWD OF DR2L. REPLACED BATTERY PACK, CHECKS GOOD.SDR UALA2010111504201Light · malfunctionedEXIT PATH LIGHTING ON RIGHT SIDE OF COACH ILLUMINATED. ACCOMPLISHED A TEST OF THE EMERGENCY LIGHTS, OPS CHECKED NORMAL ON GROUND.SDR UALA2010111504202Bushing · missingLEFT OVERWING BSLIDE DOOR DEPLOY CABLE IS MISSING SPACER, BUSHING ON THE FWD LOWER PULLEY. SUPPLEMENTAL DATA UPDATE, INSTALLED BUSHING INTO OVERWING SLIDE DOOR DEPLOY CABLE LOWER FWD PULLEY. OPS CHECKS GOOD.
Back to Pratt & Whitney PW4060