Pratt & Whitney PW4060
Service difficulty reports · 7,181
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2016022995169Floorbeam · corrodedMAJOR REPAIR, STATION 346, FLOORBEAM UPPER CAP CORRODED, BETWEEN RBL 28 & RBL 53. DAMAGE CUT OUT & REPAIR ACCOMPLISHED IAW 53-00-51 REPAIR 1 DETAIL 5.SDR CALA2016022995170Floorbeam · corrodedMAJOR REPAIR, STATION 324 FLOORBEAM UPPER CAP CORRODED, AT RBL 54. CORROSION REMOVED & REPAIR ACCOMPLISHED IAW SRM 53-00-51 REPAIR 2 DETAIL 1.SDR CALA2016022995171Battery · dischargedEMERGENCY EXIT LIGHTS INOPERATIVE. CEILING ABOVE ROWS 29 RT THROUGH AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07 PG 201.SDR CALA2016022995172Battery · dischargedEMERGENCY EXIT SIGN INOPERATIVE, JUST ABOVE & AFT OF ROW 39 RT. REPLACED BATTERY AT M734 IAW MM 33-51-07.SDR CALA2016022995173Battery · dischargedEMERGENCY EXIT SIGN INOPERATIVE AT AFT GALLEY RT SIDE. REPLACED BATTERY AT M734 IAW MM 33-51-07.SDR CALA2016022995174Battery · dischargedEMERGENCY EXIT LIGHT INOPERATIVE, DOOR 2 RT SILL LIGHT. REPLACED BATTERY AT M734 IAW MM 33-51-07.SDR CALA2016022995175Light · inoperativeEXTERIOR EMER EXIT LIGHT INOPERATIVE, FIRST LIGHT JUST AFT OF RT WING TE ON FUSELAGE. RELAMPED. OPERATIONS CHECKED NORMAL.SDR CALA2016022495125Unknown · malfunctionedAISLE PATH FLOOR STRIP BY LAVATORY 2L, OTBD REMAINS ON & ALSO EXIT SIGN. TROUBLE SHOT IAW SSM 33-51-01 & WDM 33-51-13. FOUND L979, EXIT SIGN, & AISLE PATH FLOOR STRIP AT LAVATORY 2L TO BOTH HAVE THE SAME POWER SUPPLY M1561. R & R M1561 EE LT BATTERY SUPPLY SDR CALA2016022495135Actuator · seizedTRAILING EDGE FLAP DISAGREE, FOUND NR 2 & 7 FLAP ROTARY ACTUATOR OVERLOAD INDICATORS TRIPPED, DUE TO SEIZED FLAP ACTUATOR. R & R FLAP ACTUATOR, RETURN TO SERVICE.SDR CALA2016022495130Frame · crackedAFT PIT, BS 1197+132, FRAME WEB CRACKED, AT LBL 32 & 35. REMOVED DAMAGE, HFEC, FABRICATED & INSTALLED REPAIR PARTS IAW ERA 5360-01433.SDR CALA2016022495129Frame · corrodedBS 1197+132, AFT PIT FRAME, T CAP CORRODED. REMOVED & INSTALLED NEW T CAP IAW SRM 51-40-05.SDR CA160215004Valve · defective(CAN) ACFT WAS DISPATCHED WITH PACK 2 INOPERATIVE. AFTER DEPARTURE THE TEMPERATURE WAS AT 30C AND UNCONTROLLABLE. CREW ELECTED TO RETURN TO DEPARTURE AIRPORT. IAW T/S ACTION. PRSOV TRIM AIR VALVE, LT REPLACED IAW AMM 21-61-06. LEAK AND FUNCTIONAL CHKS OFSDR CALA2016021295100Cap · corrodedAFT CARGO COMPARTMENT BS 1197, RBL 44, T CAP HAS CORROSION ON LOWER SURFACE. FABRICATED, DRILLED & INSTALLED T CAP IAW SRM 51-40-02 PARA 4 FIG 3 & 8 PARA 7D FIG 12 & SRM 51-30-01 PARA 7 FIG 7, 51-40-05 PARA 4 FIG 1 & DWG 146T1206.SDR CALA2016021295101Cap · corrodedAFT CARGO COMPARTMENT, BS 1197+44, RBL 46, T CAP HAS CORROSION ON LOWER SURFACE. R & R NEW T CAP, PN 146T1060-1, IAW DWG 146T1225 & SRM 51-40-02 PARA 4 FIGS 3, 8, 12 & SRM 51-40-05 FIG 2.SDR CALA2016020895093Light · inoperativeEXTERIOR EMER EXIT LIGHT INOPERATIVE. RT SIDE OF FUSELAGE JUST FWD OF AFT CARGO DOOR. RELAMPED EXTERIOR EMER EXIT LIGHT.SDR CALA2016020495088Floorbeam · corrodedCABIN STATION 1584, LBL 21 FLOORBEAM HAS CORROSION. CORROSION R & R ACCOMPLISHED IAW SRM 51-10-02 & SRM 53-00-51 REPAIR 2 FIG 201 DETAIL I.SDR CALA2016020895091Skin · dentedBODY STATION 347, STRINGER 28L - S29L, EXT FUSELAGE SKIN DENT. REMOVED DAMAGE. HFEC FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-01 REPAIR 29 FIGURE 201.SDR CALA2016020495080Light · inoperativeEMERGENCY EXIT CEILING LIGHT INOPERATIVE AT ROW 10 RT. RELAMPED & OPERATIONS CHECKED NORMAL.SDR CALA2016020495081Connector · unsecureEMERGENCY EXIT LIGHT INOPERATIVE AT AFT GALLEY FLOOR. SECURED CONNECTOR. OPERATIONS CHECKED NORMAL.SDR CALA2016020495082Light · inoperativeEXTERIOR EMER EXIT LIGHT INOPERATIVE AT DOOR 2 LT. RELAMPED EMER LIGHT IAW AMM 33-51-03.SDR CALA2016020495083Light · inoperativeEXTERIOR EMER EXIT LIGHT INOPERATIVE AT DOOR 2 RT. REPLACED EMER EXIT LIGHT IAW AMM 33-51-03.SDR CALA2016012895059Battery · dischargedSEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEAT ROW 35 RT - 39 RT. REPLACED BATTERY AT M99804 IAW MM 33-51-07 PG 201. OPERATIONS CHECKED NORMAL.SDR CALA2016011294995Wire · chafedBREAKER P36 ON P11 RESETS, BUT POPS WHEN SQUIB TEST 1 PRESSED. ON PUSHBACK & DURING POWER XFER BREAKER ALSO POPPED. REPLACED RT OFF WING ESCAPE SYS EMER BATTERY CHARGER ASSEMBLY. BREAKER P36 ON P11 STILL TRIPS DURING SQUIB TEST 1. ALSO TRIPS WITH CONNECTORSDR CALA2016011594999Wire · chafedBREAKER P36 ON P11 RESETS, BUT POPS WHEN SQUIB TEST 1 PRESSED. ON PUSHBACK & DURING POWER XFER BREAKER ALSO POPPED. REPLACED RT SIDE OFF WING ESCAPE SYS EMER BATTERY CHARGER ASSEMBLY. BREAKER P36 ON P11 STILL TRIPS DURING SQUIB TEST 1. ALSO TRIPS WITH CONNSDR CALA2016010894977Connector · unsecureEMERGENCY EXIT FLOOR EMER EXIT LIGHT INOPERATIVE, JUST FWD OF SEAT 1K. SECURED BATTERY CONNECTOR. OPERATIONS CHECKED NORMAL.SDR CALA2016010894978Connector · unsecureLOWER FWD EMER EXIT SIGN INOPERATIVE AT DOOR 1 RT. SECURED BATTERY CONNECTOR. OPERATIONS CHECKED NORMAL.SDR CALA2016010894979Lug · unsecureTOP FWD EMER EXIT SIGN INOPERATIVE AT DOOR 2 LT. SECURED CONTACT LUG BEHIND SIGN. OPERATIONS CHECKED NORMAL.SDR CALA2016010894980Battery · dischargedSEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEAT ROWS 34 LT - 39 LT. REPLACED BATTERY AT M739 IAW SSM 33-51-01. LIGHTS OPERATIONS CHECKED NORMAL.SDR CALA2016010894981Skin · dentedDENT ON FUSELAGE AT STRINGER 37 RT & BS 654+44, JUST AFT OF FWD CARGO DOOR. REPAIRED FUSELAGE SKIN IAW SRM 53-00-01 FIG 201 REPAIR 12.SDR CALA2016010894970Cap · corrodedCORROSION ON LOWER SURFACE OF T CAP IN AFT CARGO PIT, STATION 1197+88 & RBL 36. UPON EVALUATION FOUND T CAP TO HAVE 100% MATERIAL LOSS. OUT OF LIMITS IAW SRM 53-00-07 FIG 101. R & R T CAP 146T1060-01 IAW SRM 51-40-05 & 51-40-02.SDR CALA2016010894971Cap · corrodedCORROSION ON LOWER SURFACE OF T CAP IN AFT CARGO PIT, STATION 1131, LBL 36. T CAP IN AFT CARGO HAD 100% MATERIAL LOSS. R & R IAW SRM 51-40-02.SDR CALA2016010894961Strut · brokenAFTER TAKEOFF ACFT EXPERIENCED A VIBRATION IN AREA OF NLG. ACFT RETURN TO FIELD. FOUND NLG LT AFT DOOR ATTACH STRUT BROKEN. REPLACED & ADJUSTED THE LT AFT NLG DOOR OPERATOR STRUT ASSEMBLY IAW AMM 32-22-04. JACKED NOSE IAW AMM 07-11-02 & SWUNG GEAR TO VERIFSDR CALA2016010894963Connector · disconnectedLOWER EMER EXIT LIGHT SIGNS AT DOORWAYS 1LT & 1 RT INOPERATIVE. CONNECTED EMER LIGHT BATTERY PACK CONNECTOR AT LOWER FWD CORNER OF EMER EXIT DOORWAY LIGHT IAW WDM 33-51-11. OPERATIONS CHECK OF ABOVE EMER EXIT LIGHTS, FOUND NORMAL IAW AMM 33-51-00.SDR CALA2016010894964Connector · disconnectedLOWER EMER EXIT LIGHTS AT LT & RT OVERWING INOPERATIVE. TOTAL OF 4 LIGHTS. CONNECTED EMER EXIT LIGHT BATTERY PACK CONNECTOR AT LT & RT EMER EXIT LIGHT IAW WDM 33-51-11. OPERATIONS CHECKED NORMAL IAW AMM 33-51-00.SDR CALA2016010894966Connector · disconnectedLOWER EMER EXIT LIGHTS AT DOORWAYS 2 LT & 2 RT INOPERATIVE. CONNECTED EMER LIGHT BATTERY PACK CONNECTOR AT LOWER FWD CORNER OF EMER EXIT DOORWAY LIGHT IAW WDM 33-51-11. OPERATIONS CHECK OF ABOVE EMER EXIT LIGHTS FOUND NORMAL IAW AMM 33-51-00.SDR CALA2015123094925Floorbeam · corrodedCORROSION ON LOWER SURFACE OF T CAP IN AFT CARGO PIT STATION 1219, LBL 36. R & R AFT CARGO COMPARTMENT, T CAP AT STATION 1219 IAW SRM 51-40-02 & DWG 146T0250.SDR CALA2016010494937Frame · crackedSTATION 1140 RT TENSION TIE FRAME WEB, 2 EACH FASTNER HOLES CRACKED. STATION 1140 RT TENSION TIE FRAME WEB R & R IAW SRM 53-40-07 REPAIR 2 FIG 201 REV 94 & DWG 65B01570 REV C.SDR CA151229012Transmitter · failed(CAN) AT APPROXIMATELY 1000FT AGL GO AROUND WAS INITIATED DUE TO AN EICAS FLAP T/E ASYMMETRY AND T/E CAUTION MESSAGE. FLAPS WERE STUCK AT FLAP 30. ACFT DECLARED A PAN PAN AND AFTER COMPLETING CHECKS, RETURNED FOR A SUCCESSFUL LANDING WITH CFR STANDING BY. RSDR CALA2015122494915Light · arcedON FINAL APPROACH LIGHT BURNING ODOR NOTED. SMOKE ALARM IN LAVATORY 2R WENT OFF, NO APPARENT FIRE. CAPTAIN STATES MID RT LAVATORY IS WHERE SMOKE DETECTOR ACTIVATED. INSPECTED LAVATORY WATER HEATER, LAVATORY ASSEMBLY, ASSEMBLY ELEC COMPONENTS FOR ANY SIGN OFSDR CALA2015122494916Light · inoperativeEXTERNAL EMERGENCY LIGHT AT R2 DOOR INOPERATIVE. RELAMPED, R & R AFT RT LIGHT ASSEMBLY. FOUND PUSHED BACK PIN AT CONNECTOR M733, SECURED IAW WDM 33-51-06. OPERATIONS NORMAL.SDR HALA2015121800250Engine · malfunctionedETOPS SIGNIFICANT SYSTEM, IN CRUISE FL370 STATUS MESSAGE RT OIL FILTER 2 MINUTE LATER RT OIL FILTER EICAS MSG ILLUMINATED, RETARDED RT ENGINE LEVER PROGRESSIVELY UNTIL EICAS OUT IAW QRH PROCEDURE EICAS WOULD ILLUMINATE UNTIL POWER REDUCED TO FOLLOWING SETTINGSSDR CALA2015121494877Shear Tie · corrodedSHEAR TIE CORRODED AFT CARGO BS 1562, STRINGER 38L - 38R. REPAIRED IAW ECRA 5360-01383. REPAIRED HAS BEEN APPROVED FOR STATIC STRENGTH VIA FAA 8100-9 DTD 7 -7-2014.SDR CALA2015121494887Floorbeam · corrodedCABIN BS 287, RBL 50, FLOORBEAM UPPER CHORD CORROSION. REMOVED CORROSION, HFEC FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-51 REPAIR ONE FIGURE 201.SDR CALA2015121494886Skin · dentedMAJOR REPAIR, DENT IN FUSELAGE WAS CUT OUT & A DOUBLER INSTALLED AT STATION 654.44 - 654.66, & STRINGER 34R - 35R. REPAIR WAS ACCOMPLISHED IAW SRM 53-00-01 REPAIR 14 FIG 201 DETAIL 1. THIS IS A CAT B REPAIR LOCATED IN ZONE A & WILL REQUIRE REPETITIVE INSPECTSDR CALA2015112394850Charger · defectiveEMERGENCY EXIT LIGHTS INSPECTION AT SEAT 19 - 23 AB. R & R EPSU CHARGER FOR SEAT ROWS 19 - 23 AB AMM 33-51-07. POWER SUPPLY OPERATIONS TEST COMPLIED WITH AMM 33-51-07-712-032. TEST CHECKED GOOD.SDR CALA2015111994848Light · inoperativeSEAT ROWS 8AB, JK 7AB, 2A HAVE ONE EACH BULB INOPERATIVE FOR EMER LIGHTING. RELAMPED SEATS AS REQUIRED. OPERATIONS CHECKED GOOD.SDR CALA2015111994849Light · inoperativeSEAT ROWS 28L & 38R ALSO CEILING PANEL 35 LT SIDE EMER LIGHTS INOPERATIVE. RELAMPED SEAT ROWS 28LH, 34LH, 35LH & 33RH. OPERATIONS CHECKED GOOD.SDR CALA2015111794827Floorbeam · corrodedCABIN FLOORBEAM STATION 1562, LBL30, HAS CORROSION AT BOLT HOLE. REPAIRED IAW SRM 53-00-51 REPAIR 2 FIG 201.SDR CALA2015111794828Floorbeam · corrodedFLOORBEAM CORRODED ON UPPER SURFACE AT BS 1461, LBL 11. INSTALLED REPAIR IAW SRM 53-00-51 REPAIR 1 FIG 201.SDR CALA2015111794816Floorbeam · corrodedBS 325, RBL 17 FLOORBEAM UPPER CHORD CRACKED. UPPER CHORD REPAIRED IAW ECRA 5310-06646. THIS IS A CATEGORY A REPAIR.
Back to Pratt & Whitney PW4060