Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012040502116Structure · brokenRIGHT NOSE GEAR DOOR PROTECTIVE LIP METAL TRIM BROKEN. REPAIR BY APPLYING TWO LAYERS OF SPEED TAPE. NO LOOSE FASTENERS AND TAP TEST WAS GOOD.SDR UALA2012040302074Unknown · unknownDURING REFUELING NOTICED LEFT CTR REFUEL VLV LIGHT NOT ON AT IRP AND REFUEL FLOW REDUCED. SYSTEM OP CHECKED NORMAL. COULD NOT DUPLICATE THE PROBLEM.SDR UALA2012040302077Shutoff Valve · faultyRECEIVED FUEL IMBALANCE MESSAGE, ABOUT 7 HRS INTO FLT (MAIN TANKS) TEXT FROM LOGS 5-7: BALANCED AT TAKEOFF. JUST BEFORE CENTER TANK EMPTY. RT MAIN HAD INCREASED 2000 LBS TO ABOUT 65.6. OVER THE NEXT 3 HRS THE RT TANK CONTINUED TO GAIN ON THE IMBALANCE UNTIL SDR UALA2012040202057Display · inoperativeOUTBOARD DISPLAY INOPERATIVE. REPLACED DISPLAY, CHECKED OKAY.SDR UALA2012040202046Idg · faultyRIGHT ENGINE GENERATOR WILL NOT COME ON LINE. REMOVED NR 2 ENG IDG PER AMM. NEED TO INSTALL NEW IDG. INSTALLED NR 2 ENGINE IDG PER MM. IDLE LEAK AND OPS CHECKED OKAY.SDR UALA2012040202016Module · faultySEATS 9C AND 9D POWER TURNED OFF UNDER SEAT FROM ELEC ODOR AT BASE OF SEATS. ON ARRIVAL, NO ODOR FOUND. FOUND J2 CONX ON RD-KM6453-0808 BURNT AND P2 CONX ON RD-KM6480-2323 BURNT, REMOVED AND REPLACED BOTH PAC CABLES AND PAC SPM RD-FA3621-01 SN ON 34370 SN SDR UALA2012040202045Battery · dischargedON ARRIVAL RECEIVED FLIGHT CONTROL SYS ON MAT MESSAGE 24-50241, LEFT FC BATTERY IS LOW, PER FIM 24-35 TASK 802. REPLACED BATTERY, MESSAGE EXTINGUISHED, PER MM OPERATIONAL TEST, NO FAULTS FOUND.SDR UALA2012040202047Module · malfunctionedWEATHER RADAR HAS HEAVY STROBE AT AN 8 MILE ARC. REPLACED LEFT AIMS COMM 2 MODULE. WEATHER RADAR SYSTEM OP'S CHECKED GOOD.SDR UALA2012033001989Valve · malfunctionedDURING REFUELING, FOUND CENTRE TANK LT REFUEL VALVE DID NOT OPEN. DEPOWERED AND REPOWERED. CENTER TANK LT REFUEL VALVE NOW OPERATING NORMALLY.SDR UALA2012040202041Plate · looseNR 2 ENGINE PYLON ELECRICAL FEEDER CABLES W8100 & W8101 RETAINMENT PLATE IS LOOSE & HAS MIGRATED AFT. VIEWED FROM INSIDE OF PYLON DISC BOX ON FWD FACE OTBRD MOST FEED THRU.SDR UALA2012033002000Heat Shield · wornRIGHT HEAT SHIELDS WORN. REMOVED PYLON HEAT SHIELDS NR 2 ENG, PER MT 54-UA2. OUT OF LIMITS. REPAIRED HEATSHIELD. INSTALLEDSDR UALA2012033002001Shutoff Valve · warning lightTRIM AIR PRORITY SHUTOFF VALVE RT STATUS. REPLACED OPS CHECKED GOOD AND PASS MAP TEST.SDR UALA2012032801958O-Ring · cutFUEL IMBALANCE, LEFT FUEL INDICATION INCREASE SLOWLY. TEST FUEL QUANTITY INDICATION SYSTEM PER AMM. NO FUEL QTY STATUS MESSAGE, NO TANK UNITS & DENSITOMETERS FAULTS IN HISTORY. CONFIRMED SLOW RATE SUGGEST REMOVING LT PUMPS FOR INSPECTION AND POSSIBLE TANK ESDR UALA2012032701935Connector · unsecureNR 2 ENGINE, FUEL DIFFERENTIAL PRESSURE SWITCH CONNECTOR, BACKSHELL IS LOOSE. *SUPPLEMENTAL DATA UPDATE* RE-SECURED CONNECTOR.SDR UALA2012032701939Controller · failedL RAM AIR DOOR FAULTS. ACFT TEMP CONTROL SEEMS TO BE ADJUSTING ITSELF TEMP CONTROL IS INACCURATE THIS IS FOR THE WHOLE ACFT. LT RAM AIR INLET FAULTS AND STOPS TEST. LT RAM AIR INLET ACTUATOR LOCKED IN THE FULL OPEN AND CONNECTOR PLUG REMOVED. REPLACED LT CSDR UALA2012032801955Attach Fitting · damagedTWO FILLER PANELS BETWEEN PASSENGER SERVICE UNITS, BETWEEN LEFT AND RIGHT CENTER OVERHEAD BINS ARE HANGING DOWN. REPLACED MISSING CLIPS.SDR UALA2012032801956Nut Plate · brokenNUT PLATE FOR VERTICAL STABILIZER ACCESS PANEL 322FL IS BROKEN, LOCATED BOTTOM FRONT LEADING EDGE CORNER. REPLACED NUT PLATE AS REQUIRED.SDR UALA2012032701943Peep Sight · misinstalledCOCKPIT DOOR PEEP HOLE APPEARS TO BE INSTALLED IN REVERSE. REPLACED FLT DECK DOOR PEEK HOLE.SDR UALA2012032601922Structure · dentedDENT REPORTED FWD OF FWD CARGO DOOR, LOWER CORNER. AT STATION 501, WATERLINE 37-38. DENT APPROX 1"WIDE X 1. 5 INCH LONG. .015 DEPTH. DENT WITHIN LIMITS OF SRM 53-00-01 TABLE A, AND E. DENT DOT PROCESS NEEDS TO BE ACCOMPLISHED PER GMM 06-35-05. EVAL WAS ACPSDR UALA2012032301877Light · brokenDOOR 4LT EMERGENCY LIGHT ASSY BROKEN. REPLACED DOOR 4LT UPPER EMERGENCY EXIT LIGHT ASSY, OP CHECKS GOOD ON GROUND.SDR UALA2012032601907Switch · detachedJETTISON ARMING SWITCH CAME OFF. REPLACED SWITCH ASSY. VERIFIED JETTISON ARMING FUNCTIONED NORMAL.SDR UALA2012032201838Heat Shield · damagedHEATSHIELD SET INSTALLED ON THE NR 1 POSITION WAS LINE REPAIRED, NOT HEAT TREATED OR FLAME SPRAYED. HEAT SHIELDS REPAIRED IAW ECRA 5454-01037. HEAT SHIELDS REPAIRED IAW ECRA 5450-01902.SDR UALA2012032201836Satcom · malfunctionedEIGHT HOURS IN THE FLIGHT THE AIRCRAFT LOST SATCOM, ALL HF AND DATALINK FOR 1:20 MIN. RETURNED FOR 2 HRS THEN LOST ALL AGAIN FOR .5 HR. ACFT WAS NORDO FOR THIS PERIOD OF TIME. ON GROUND BOTH HF WORKS NORMAL. ANY MSG COME ON, COULD NOT FIND ANY CAUSE OF INOSDR UALA2012032301868Oven · dirtyBURNING ODOR 2R. NO SMOKE. ITEM ROLLED FORWARD. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DE-ACTIVATED W31 OVENSDR UALA2012032201824Oven · dirtyBURNING ODOR 2R, NO SMOKE. FOUND PLASTIC BUGS BURNT IN WARMING OVEN W31 CAUSED BURNING ODOR IN THE DOOR 2 AREA. REMOVED BUGS FROM OVEN. NEED TO CLEAN DEBRIS IN THE OVEN OR REPLACE ITSELF. CONSULTED WITH TOMC AND DEACTIVATED W31 OVEN PER MEL PROC. CREW ALSSDR UALA2012032201832Unknown · unknownFLIGHT CREW REPORTED THEY COULDN'T TRANSMIT OVER ACARS AND ANY QUERY BY THEM ON ACARS DIDN'T WORK. ATTEMPTED TO TROUBLESHOOT WITH NO SUCCESS.SDR UALA2012032001811Skin · damagedCATEGORY 'B' REPAIR ACP IAW SRM 53-0-01 REPAIR 7 (PAGE 109-127 OF 210). ZONE B INSP THRESHOLD IS 30,000 CYCLES WITH INSP INTERVAL OF 16,000 CYCLES. EXT FUSE SKIN AT STA 676 TO 697 S26L TO S27L DAMAGE REMOVED IAW SRM 53-00-01 REPAIR 7. HOLES NOT ZERO TIMED. SDR UALA2012032201834Skin · dentedTWO DENTS WERE FOUND ON OUTER SKIN OF LT FUSELAGE STA 676 TO STA 697, S26L TO S27L. CATEGORY B REPAIR ACP IAW SRM 53-00-01 REPAIR 7 (PAGE 109-127 OF 210).SDR UALA2012032201835Sensor · faultyEQUIP COOLING HORN IS GOING OFF WITH AN UPPER LEVEL ADVISORY EICAS EQUIP COOLING MSG. ALSO HAS AN AIR TEMP HIGH STATUS MSG WITH MAINT CODE 21-14081. ACP FIM 21-27 TASK 821, FOUND EQUIP LOW FLOW DETECTOR M21582 TO BE DEFECTIVE. REPLACED LOW FLOW SENSOR PER MSDR UALA2012032001797Controller · faulty'EQUIP COOLING' ADVISORY MSGS DISPLAYED UPPER EICAS. 'EQUIP COOLING CTRL L' STATUS ALSO. REPLACED EQUIPMENT COOLING CONTROLLER PER MM. GRN TEST AND OPS CHECK NORMAL.SDR UALA2012031901766Spar · corrodedRT WING REAR SPAR WEB CORROSION AROUND FASTENERS BETWEEN IRSS 340 AND IRSS 350 WHERE FUEL BOOST PUMP IS INSTALLED. REF 777EN-57-0299. BLEND OUT REPAIR ACP IAW ECRA 5720-02266.SDR UALA2012031901767Spar · corrodedLT WING REAR SPAR WEB CORROSION AROUND FASTENERS BETWEEN IRSS 340 AND IRSS 350 WHERE FUEL BOOST PUMP IS INSTALLED. REF 777EN-57-0300. BLEND OUT REPAIR ACP IAW ECRA 5720-02267.SDR UALA2012031901790Blower · faultyTHREE LAVS INOP, FLIGHT DIVERTED. LAVS AT 2R, 3L AND 4L INOP. NEED TOILETS REPLACED. SAMC REMARKS: BAD VACUUM SHUT OFF VALVES. PARTS: 120-9074 15800-029-3 (TOILET ASSY) 120-9075 15800-029-4 (TOILET ASSY). OP CHECKED AND LEAKED CHECK ALL THREE LAVS THATSDR UALA2012031901782Shutoff Valve · faultyAIR DEMAND C1 HYD PUMP APPEARS TO RUN CONT REGARDLESS OF SWITCH POSIT. REPLACED MODULATING SHUTOFF VALVE C1 HYD PUMP AS PER MM. ALL OPS AND CHECK OKAY.SDR UALA2012031901784Grommet · not seatedNR 1 ENGINE I/B GENERATOR FEED CABLES AT PYLON DISCONNECT BOX GROMMET MIGRATED AFT. CORRECTIVE ACTION AS REQUIRED. CUT LACING CORD ALONG FEEDER CABLE INSIDE BOX FOR ACCESS TO HARDWARE. RESEATED GROMMET, INSTALLED LACING CORD, RE-INSTALLED HEAT BLANKETS AND SDR UALA2012031901744Hydraulic Line · frayedRT MAIN GEAR DOWNLOCK HYD LINE FRAYED. HOSE LINE IS SERVICEABLE, WRAPPED WITH TAPE. REPLACED FRAYED HYD LINE. ACTUALLY TILT ACT HYD LINE PN 120-4155. SECURED AND LEAKED CHECKED IAW WITH SPECS FROM AMM 32-32-18.SDR UALA2012031901756Striker · faultyFLIGHT DECK DOOR (ENHANCED SECURITY DOOR) - DOES NOT UNLOCK WITH SWITCH SET TO UNLKD. CREW COMMENTS: PUSH BEFORE ROTATE FUNCTION INOP. POSSIBLE BAD PRESSURE SENSOR M52006?????. RPLC'D ELECTRIC STRIKER, OPS NORMAL.SDR UALA2012031601732Relay · faultyELECT STBY SYS STATUS MSG. MAT SHOWED MAINT MSG. 24- 13037 LATCHED. ACCOMPLISHED FIM 24-32 TASK 802 AND FAULT WOULD NOT UNLATCH. REPLACED RELAY K24013 REF FIM 24-32 TASK 802. MSG CLEARED.SDR UALA2012031401684Connector · faultyLIGHTING HARNESS LOCATED ON STR CLIP BETWEEN STA 1580 & 1601 STR 12R CONNECTOR D5188J IS NON COMPLIANT PER FCD 3321-01019 REV C PG 34 STEP 13. REPLACED CONNECTOR. ACCOMPLISHED INSPECTION AS REQUIRED REF FCD 3321-01019.SDR UALA2012031401685Connector · faultyLIGHTING HARNESS LOCATED BETWEEN STA 1580 & 1601 STR 12R, CONNECTOR D5188P IS NON COMPLIANT PER FCD3321-0101 9 REV C PG 34 STEP 13. REPLACED CONNECTOR D5188P REF FCD3321-01019. ACCOMPLISHED INSPECTION AS REQUIRED REF FCD 3321-01019.SDR UALA2012031401686Connector · faultySIDE WALL LIGHTING CONNECTOR DM33084E LOCATED AT STA 1840 LBL 90, CONNECTOR IS NON COMPLIANT PER FCD 3321- 01019 REV C PG 32 STEP 8. REPLACED CONNECTOR DM33084E REF FCD 3321-01019. ACCOMPLISHED INSPECTION AS REQUIRED REF FCD 3321-01019.SDR UALA2012031401688Connector · faultyLIGHTING HARNESS ON STR CLIP BETWEEN STA 1970 AND 1990 LT STR 12L CONNECTOR DM33036A IS NON COMPLIANT PER FCD 3321-01019 STEP 12 PG 34. REPLACED CONNECTOR DM33036A REF FCD 3321-01019. REPLACED CONNECTOR DM33036A REF FCD 3321-01019. ACCOMPLISHED INSPECTION ASDR UALA2012031401689Connector · improper partLIGHTING HARNESS ON STR CLIP BETWEEN STA 1970 1990 LT STR 12L CONNECTOR DM33036B IS NON-COMPLIANT PER FCD 3321- 01019. NEED TO SEND OLD CONNECTOR TO SFOEG. REPLACED CONNECTOR DM33036B REF FCD 3321-01019.SDR UALA2012031401690Connector · faultyLIGHTING HARNESS ON STR CLIP BETWEEN STA 1970 AND 1990 LT STR 12L CONNECTOR DM33036C INS NON-COMPLIANT PER FCD 3321-01019. NEED TO SEND OLD CONNECTOR TO SFOEG. REPLACED CONNECTOR DM33036C REF FCD 3321-01019.SDR UALA2012031401691Connector · defectiveSIDEWALL LIGHT BALLAST CONNECTOR DM33084E WON'T LOCK AT 41ABC. REPLACED SIDEWALL LIGHT ASSY AT ROW 41ABC PER AMM, OPERATIONAL CHECK OK.SDR UALA2012031601728Connector · faultyTRIM AIR LT STATUS MSG WHEN APU OFF. RPL'D BENCH PLUG TWINA X 1T ON DM21631AA REF WDM AND SWPM. CTC-L OPS CHECKED GOOD. NO STATUS MSG. RAN PACKS, ALL INDICATIONS NORMAL.SDR UALA2012031301655Structure · dentedCLUSTER OF 3 SMALL DENTS AT BS 681-697 BELOW STR 27R. MAJOR REPAIR ACCOMPLISHED. INSTALLED EXTERNAL DOUBLER REPAIR. HOLES WERE NOT ZERO-TIMED DUE TO POSSIBILITY OF SHORT EDGE MARGIN. THIS IS A CATEGORY "B" REPAIR.SDR UALA2012031401700Connector · unsecurePSU CONNECTOR AT 40J VERY DIFFICULT TO SECURE. CONNECTOR FOR PSU OXYGEN PANEL BAD. PCN 566-1135 IS NEEDED. CONNECTORS ARE TAPED AND SECURED. PSU PANEL IS SECURED. PARTS: 566-1135 AMC02PA03W PLUG. RPL'D CONN D35067P (WDM35-21-19 ) & INSTALLED PSU PNL IASDR UALA2012031301659Fmu · faultyREPLACE FUEL PUMP AND METERING UNIT FMU AS FOLLOW UP TO TAILPIPE FIRE REMOVED NR 1 ENGINE FMU REF MM. MR73205-57 OFF PER EG6769-1. REPLACED NR 1 ENG FUEL METERING UNIT PER MM, REFERENCE EG6769-1.SDR UALA2012031301657Connector · wrong partSTATION 1840 LBL 90, 2 EACH WRONG CONNECTORS INSTALLED. REF FCD 3321-01019 PAGE 32 ITEM 8. REPLACED CONNECTOR.
Back to Pratt & Whitney PW4090-3