Rolls-Royce RB211-535E4 series
Service difficulty reports · 2,136
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'RB211535E4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'RB211535E4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10563031Floor Panel · delaminatedINSPECTION TYPE:C4, BS 1100 TO 1060 LBL 25 TO BL 0 FLOORBOARD IS DELAMINATED AT EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G, APP B AND EO B757-5100-33281-BSDR IPXA10563032Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 340-440 BL 0 - LBL 25 WL 208 HAS 4 DAMAGE INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G, APP B.SDR IPXA10563033Floorboard · delaminatedINSPECTION TYPE:C4, BS 1100 TO 1060, BL 0 TO RBL 25, FLOORBOARD IS DELAMINATED AT EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692, APP B.SDR IPXA10563047Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1600-1681 RBL 25-RBL 45 HAS DAMAGED INSERTS, PUNCTURED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563054Floorboard · delaminatedINSPECTION TYPE:C4, BS 1200 TO 1100, RBL 25 TO 45 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563062Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGE BAY FLOOR PANEL BS 820-879 LBL 45-60 WL 208 IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NO B757-5320-9692-G.SDR IPXA10563077Floor Panel · puncturedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480-560, LBL 25-45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563090Floor Panel · wornINSPECTION TYPE:C4, MCB FLOOR PANEL BS 480-560, BL0 - LBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. REPLACED MCB FLOOR PNL IAW EO NO B757-5320-9692-G, STEPS 1-7.SDR IPXA10563100Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420, LBL 45 - LBL 60 IS PUNCTURED. FABRICATED REPLACEMENT FLOORBOARD AT MAIN CABIN BS 1320 -1420, LBL 45 - LBL 60 IAW EO NR B757-5320-9692-G.SDR IPXA10563103Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200-1320 BL 0 - LBL 25 IS DELAMINATED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200-1320, BL0 - LBL 25 IAW EO B757-5320-9692-G.SDR IPXA10563104Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200-1320, RBL 25-RBL 45 IS PUNCTURED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200-1320, RBL 25 - RBL 45 IAW EO B757-5320-9692-G.SDR IPXA10563105Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200 -1320, RBL 45 - RBL 60 IS HAS MISSING INSERTS, PUNCTURED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200 - 1320 RBL 45 -RBL 60 IAW EO B757-5320-9692-G.SDR IPXA10563121Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420, LBL 25- 45 HAS MISSING INSERT. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563123Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560- 620, BL0 - LBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563124Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560 - 620, LBL 25 - 45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563125Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480 - 560, BL 0 - RBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563126Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480 - 560, RBL 25 - 45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563146Floorboard · brokenINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420 RBL 45-RBL 60 IS BROKEN. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563147Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560-620, RBL 25-45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563148Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480-560, RBL 45-62, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT PANEL IAW ER B757-5320-9692-G.SDR IPXA10563149Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560-620, BL 0 - RBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563150Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1020-1060, RBL 45-65, WL 208 IS DELAMINATED AT EDGES. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563151Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 879-900, RBL 45-62, WL 208 HAS 2 DAMAGED INSERTS. FABRICATED REPLACEMENT FLOOR PANEL IAW E0 B757-5320-9692-G.SDR IPXA10563156Floor Panel · puncturedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1320-1400, RBL 25-45, WL 208 IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563160Floorboard · delaminatedINSPECTION TYPE:C4, BS 1200 TO 1100, LBL 25-BL 0 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS. FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA10563162Seat Track · corrodedINSPECTION TYPE:C4, MCB SEAT TRACK HAS CORROSION AT NUTPLATES BS 1184, LBL 60, WL 208. R & R TRACK IAW SRM 51-40-02.SDR IPXA10563163Floorboard · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOORBOARD BS 480-560, LBL 45-62, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA10563164Floorboard · brokenINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, LBL 45-LBL 60 IS BROKEN FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5100-33281 B.SDR IPXA10563165Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, LBL 25-LBL 45 HAS MISSING INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-G; EO B757-5100- 33281-B; SRM 53-00-50-1A1.SDR IPXA10563166Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, RBL 25-RBL 45, HAS MISSING INSERTS, PUNCTURED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G; EO B757-5100- 33281-B; SRM 53-00-50-1A1.SDR IPXA10563185Floorbeam · corrodedINSPECTION TYPE:C4, BS 1056, RBL 45 TO 65 FLOORBEAM IS CORRODED. REPLACED FLOORBEAM IAW SRM 51-10-02-0G AND SRM 51-40-02-0G.SDR IPXA10563186Floorbeam · corrodedINSPECTION TYPE:C4, BS 1020, RBL 25 TO RBL 45 FLOORBEAM IS CORRODED. REPLACED FLOORBEAM IAW SRM 51-10-02-0G AND SRM 51-40-02-0G.SDR IPXA10563187Floorbeam · corrodedINSPECTION TYPE:C4, BS 1020, LBL 45 TO LBL 25, FLOORBEAM CORRODED. REPLACED FLOORBEAM IAW SRM 51-10-02-0G AND SRM 51-40-02-0.SDR IPXA10563188Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, RBL 45-60, HAS MISSING INSERT. REPLACED FLOORBOARD IAW B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563189Floor Panel · crackedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420- 1400, RBL 25-45 HAS MISSING INSERT. REPLACED IAW EO B757-5320-9692-G.SDR IPXA10563194Floor Support · corrodedINSPECTION TYPE:C4, BS 1060 TO 1040, BL 0, FLOOR SUPPORT IS CORRODED. R & R FLOOR SUPPORT IAW SRM 53-40-51-0I AND DWG 144N8031-9.SDR IPXA10563196Floorbeam · corrodedINSPECTION TYPE:C4, BS 1056, BL 0 TO LBL 25 FLOORBEAM CORRODED. REPLACED FLOORBEAM IAW SRM 51-40-05-0G AND SRM 51-40-02-0G.SDR IPXA10563197Floorbeam · corrodedINSPECTION TYPE:C4, BS 1020, BL 0 TO LBL 25 FLOORBEAM CORRODED AT NUTPLATE HOLES. REPLACED FLOORBEAM IAW SRM 51-40-05-0G AND SRM 51-40-02-0G.SDR IPXA10563205Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 879 - 900 BL - RBL 25, WL 208 HAS ONE DAMAGED INSERT AND 7 DISBONDED INSERTS. FABRICATED NEW MAIN CARGO BAY FLOOR PANEL IAW EO B757-5320-9692-G AND EO B757-5100-33281 B.SDR IPXA10563206Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560 - 620, LBL 45 - 62, WL 208 IS WORN THROUGH THE REINFORCING FIBREGLASS PLIES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692 AND SRM 53-00-50-2R1.SDR IPXA10563236Stringer Clip · crackedINSPECTION TYPE:C4, MAIN CARGO STA 879, STR 16L STRINGER TIE CLIP IS CRACKED REMOVED, FABRICATED AND INSTALLED REPLACEMENT CLIP IAW SRM 51-40-02.SDR IPXA10563238Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 340- 440 BL0 - RBL 25, WL 208 HAS 1 DAMAGED INSERT. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563240Stringer Clip · crackedINSPECTION TYPE:C4, MAIN CARGO STA 879, STR 15L, STRINGER TIE CLIP IS CRACKED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT CLIP IAW SRM 51-40-02.SDR IPXA10563241Floor Support · corrodedINSPECTION TYPE:C4, BS 1040 TO 1060, LBL 25 FLOOR SUPPORT CORRODED. R & R SUPPORT IAW SRM 51-40-02.SDR IPXA10563242Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1060 - 1100, RBL 45 - 65, WL 208 IS DELAMINATED AT EDGES. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563243Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1060 -1100, RBL 25 - 45, WL 208 IS PUNCTURED AND DELAMINATED AT EDGES. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10563255Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOOR BOARD BS 1200-1320 LBL 45-60 HAS MISSING INSERTS, PUNCTURES. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A1 EO B757-5320-9692-G AND SRM B757-5100-33281-B.SDR IPXA10563256Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD, BS 1540-1600, BL 0-RBL 25 DELAMINATED. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A1, EO B757-5320-9692-G AND SRM B757-5100-33281-B.SDR IPXA10563257Floor Support · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT TRACK IS CORRODED INBD FLANGE BS 340, RBL 11, WL 208. REPAIR IAW ER 10-05046.SDR IPXA10563262Floorbeam · corrodedINSPECTION TYPE:C4, FUSE UPPER LOBE, CORROSION ON FLOOR FITTING, BS 323 TO 325. LBL 11 TO 14, WL 208. R & R IAW EO B757-5310-40175-A DATED 15-OCT-10 AND ER 10-05047 DATED 15-OCT-10.
Back to Rolls-Royce RB211-535E4 series