U/A Canada PT6A-27
Service difficulty reports · 642
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A27' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A27' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA000720004Control Cable · frayed(CAN) WHILE CARRYING OUT AN 800 HOUR INSPECTION, THE RT AILERON CABLE WAS FOUND TO BE FRAYED. THE DAMAGE TO THE CABLE WAS LOCATED AT THE PULLEY WHERE THE CABLE GOES THROUGH THE COCKPIT FLOOR BY THE COPILOT SEAT. THE 800 HOUR INSPECTION REQUIRES THAT YOU INSSDR CA000719025Actuator · cracked(CAN) PART NUMBER FOR TIME X CONDITION. CENTRE SHAFT LONGITUDINAL CRACKED. CRACK DISCOVERED AFTER REMOVAL.SDR 20000803SH010Vane · inaccurateA TREND HAS DEVELOPED INDICATING PROCEDURES, TECHNIQUES, OR WORKMANSHIP OF OVERHAULED VANE RINGS IS RESULTING IN PREMATURE FAILURE OF PN 3032651 WHICH RESULTS IN UNSATISFACTORY ENGINE PERFORMANCE AND POSSIBLE ENGINE FAILURE. (X)SDR CA000712019Bellcrank · twisted(CAN) WHILE CARRYING OUT AD CF-72-06R4 PART III, THE ELEVATOR QUADRANT WAS FOUND TO BE RUBBING AGAINST THE SIDE OF THE CABLE GUARD AS DESCRIBED IN THE AD. THE QUADRANT ASSEMBLY INCLUDING SUPPORT BRACKET WAS REPLACED PRIOR TO FLIGHT. (X)SDR CA000614034Rib · failed(CAN) WHILE THE AME WAS CARRYING OUT A 100 HOUR INSPECTON OF THE LT WING FLIGHT CONTROLS, NOTICED THERE WAS A SMALL CRACK ON THE TOP SKIN AND SEVERAL SHEARED RIVETS. THE FLAP WAS REMOVED, DISASSEMBLED AND INSPECTED. IT WAS FOUND THAT THE INTERNAL RIB P/N C3WSDR CA000621043Gearbox · making metal(CAN) AIRCRAFT RETURNED TO GOOSEBAY AFTER DEPARTURE DUE TO ENGINE PROBLEMS ON CLIMBOUT. ENGINE TORQUE DROPPED OFF FROM POWER SELECTED. CREW SHUTDOWN THE ENGINE AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTION REVEALED METAL IN THE OIL FILTER AND IN SDR 20000620SH015Blade · missingON TAKEOFF, PILOT FELT AIRCRAFT SHUDDER, RETURNED TO FIELD WITHOUT ANY DAMAGE TO AIRCRAFT. UPON INVESTIGATION ON ENGINE, FOUND 2 INCH SQUARE AREA MISSING FROM EXHAUST. UPON FURTHER INVESTIGATION, FOUND PORTION OF POWER TURBINE BLADE MISSING. THIS ENGINE HADSDR AU000400Relay · burned(AUS) GENERATOR CONTROL ASSEMBLY HEAT DAMAGE. LT REVERSE CURRENT RELAY (RCR) SEVERELY HEAT DAMAGED. RT REVERSE CURRENT RELAY HEATDAMAGED.SDR CA000606021Control Rod · cracked(CAN) DURING INSPECTION THE SERVO TAB LINK FOR THE AILERON WAS FOUND CRACKED AT THE UPPER END. THE CRACK EXTENDED FROM THE ROD END BEARING RETENTION RIVET HOLE TO THE END OF THE ROD. FOR REFERENCE SEE DEHAVILLAND IPC 27-10-00, FIG. 5 (SHEET 1 OF 1), ITEM 90. SDR 20000601SH018Fuel Cell · puncturedRIGHT NACELLE FUEL CELL FOUND LEAKING FUEL. INSPECTION REVEALED A PUNCTURE IN THE SIDE OF THE CELL CAUSED BY A TANK HANGER THAT HAD BECOME DISLODGED FROM ITS ORIGINAL LOCATION. THE HANGER PROTRUDING CLIP HAD REPOSITIONED TOWARD THE TANK LINER CAUSING THE TANSDR CA000414010Rod End · cracked(CAN) CRACK STARTING UNDER RODEND JAMNUT. APPROX. 1/2 IN LENGTHSDR 20000426SH027Fuel Line · crackedDISCOVERED FUEL LEAKING FROM LOWER COWL ON THE LEFT ENGINE ON A POST-FLIGHT INSP. INSP REVEALED THE FUEL LEAK SOURCE TO BE A HIGH PRESSURE FUEL LINE FROM THE FCU TO THE START FLOW CONTROL UNIT. THE SS LINE HAD A SMALL CRACK WHERE THE FERRULE WAS SECURED TO TSDR CA000331008Cooler · leaking(CAN) DURING ROUTINE INSPECTION IT WAS NOTED THAT THE OIL TRANSFER LINE ON THE REAR OF THE OIL COOLER WAS LEAKING UNDER STATIC CONDITIONS. WHEN THE UNIT WAS DRAINED IT WAS ALSO NOTED THAT THE DRAIN PLUG WAS THE INCORRECT TYPE. THE PLUG WAS A BOLT RATHER THANSDR CA000331009Support Bracket · wrong part(CAN) WHILE INSTALLING A NEW STARTER, THE AFT BEARING SUPPORT WAS OF A DIFFERENT TYPE THAN NORMAL. THE BEARING SUPPORT HAD A SHOULDER THAT WOULD NOT PERMIT THE COOLING DUCT TO FIT PROPERLY. UNIT WAS RETURNED FOR REPAIR.SDR CA000306008Armature · misoverhauled(CAN) PUMP WAS SENT FOR OVERHAUL. INTERNAL INSPECTION REVEALED THAT THE ARMATURE HAD BEEN MODIFIED BY REDUCING THE ARMATURE SHAFT SIZE AND SUBSTITUTING THE ORIGINAL BEARING WITH A COMMERCIAL BEARING THAT HAD THE SAME OUTSIDE DIAMETER, BUT A SMALLER INSIDE DIASDR CA000306010Armature · misoverhauled(CAN) PUMP WAS SENT FOR OVERHAUL. INTERNAL INSPECTION REVEALED THAT THE ARMATURE HAD BEEN MODIFIED BY REDUCING THE ARMATURE SHAFT SIZE AND SUBSTITUTING THE ORIGINAL BEARING WITH A COMMERCIAL BEARING THAT HAD THE SAME OUTSIDE DIAMETER, BUT A SMALLER INSIDE DIASDR 20000403AP007Fcu · malfunctionedFLT 9656 - EIS-SJU - LOSS OF POWER ON LEFT ENGINE ON CLIMB-OUT FROM EIS, 40 LBS LOW IN CRUISE. ON APPROACH WITH POWER LEVERS RETARDED FURTHER LOSS OF POWER. CREW OPTIONED TO SHUT DOWN ENGINE. EMERGENCY DECLARED. AIRCRAFT LANDED IN SJU WITHOUT INCIDENT. RESDR CA000309002Drive Shaft · misrepaired(CAN) SHAFT FOUND INSTALLED IS THE WRONG PART FOR THIS PARTICULAR STARTER-GEN. THE SHAFT IS .127 LONGER THAN THE FAN END THEN THE CORRECT P/N. SUSPECTED UNAPPROVED PARTS.INVESTIGATION REVEALED THAT PARTS WERE APPROVED AND MAINTENANCE PROCEDURES WERE AT FAULT.SDR CA000310005Gear · misrigged(CAN) CREW REPORTED ABNORMAL RUDDER INPUTS REQUIRED TO MAINTAIN STRAIGHT FLIGHT. MTCE HAD CHANGED QUADRANT GEAR LOCATED INSIDE THE RUDDER GEAR TAB. FULL RIGGING PROCEDURES WERE NOT FOLLOWED BY OPERATOR. FULL RIGGING C/W AND PROBLEM SOLVED.SDR CA000301051Ejector Valve · failed(CAN) PILOT REPORTED LOW LEVEL WARNING FROM NR 4 COLLECTOR TANK THAT FEEDS RIGHT ENGINE. BOTH ENGINES HAD TO FEED FROM LEFT TANK. INVESTIGATION REVEALED THAT EJ ECTOR PUMP MOUNTED IN NR 1 TANK WAS OBSTRUCTED BY A STRIP OF MASKING TAPE THEREFORE NOT PERMITTISDR AU000203017Control Cable · worn(AU) DURING ROUTINE 100 HOUR INSPECTION, FOUND A CABLE THAT WAS SHOWING SIGNS OF WEAR. CABLE WAS REMOVED AND INSPECTED. SEVERAL BROKEN STRANDS WERE FOUND. IT SHOULD BE NOTED THE WEAR CAN ONLY BE SEEN WITH THE FLAPS IN THE FULL DOWN POSITION. WHEN FLAPS WERSDR CA000203017Control Cable · worn(CAN) DURING ROUTINE 100 HR INSPECTION WE FOUND A CABLE THAT WAS SHOWING SIGNS OF WEAR. CABLE WAS REMOVED AND INSPECTED. SEVERAL BROKEN STRANDS WERE FOUND. IT SHOULD BE NOTED THAT THE WEAR CAN ONLY BE SEEN WITH THE FLAPS IN THE FULL DOWN POSITION. WHEN FLAPSSDR 20000522AP005Duct · damagedDURING A ROUTINE TRAINING FLIGHT, THE CREW REPORTED NR 1 ENGINE WILL NOT PRODUCE FULL POWER. DURING THE SCHEDULED ENGINE INSPECTION (EMMA NR 5) A SECTION OF BLEED AIR DUCTING WAS IDENTIFIED AS THE CAUSE. UPON FURTHER INSPECTION OF THE REMOVED DUCTING WAS NOTSDR AU000201024Brake Disc · froze(AU) UPON LANDING, THE LEFT OUTBOARD AND RIGHT INBOARD MAIN WHEEL TIRES WERE FLATTENED. BOTH BRAKE UNITS FOUND TO BE FROZEN, NOT ALLOWING WHEELS TO TURN ON LANDING. SUBMITTER STATES THIS IS THE 2ND INCIDENT WITHIN 48 HRS.SDR CA000201024Disk · frozen(CAN) UPON LANDING, THE LEFT OUTBOARD & RIGHT INBOARD MAIN WHEEL TIRES WERE FLATTENED.BOTH BRAKE UNITS FOUND TO BE FROZEN, NOT ALLOWING WHEELS TO TURN ON LANDING.SUBMITTER STATES THIS IS THE 2ND INCIDENT WITHIN 48 HRS.SDR AU000201023Brake Disc · froze(AU) WHEN AIRCRAFT LANDED, BOTH MAIN WHEEL TIRES WERE FLATTENED. BOTH BRAKE UNITS ON LEFT SIDE WERE FOUND TO BE FROZEN NOT ALLOWING WHEELS TO ROTATE ON LANDING. AIRCRAFT HAD TAXIED THROUGH DRIFTING SNOW DURING DEPARTURE PROVIDING A SOURCE OF WATER FOR SUBSEQSDR CA000201023Disk · frozen(CAN) WHEN AIRCRAFT LANDED, BOTH MAIN WHEEL TIRES WERE FLATTENED. BOTH BRAKE UNITS ON LEFT SIDE WERE FOUND TO BE FROZEN NOT ALLOWING WHEELS TO ROTATE ON LANDING.AIRCRAFT HAD TAXIED THROUGH DRIFTING SNOW DURING DEPARTURE PROVIDING A SOURCE OF WATER FOR SUBSEQUSDR CA000120013Case · corroded(CAN) 764.4 HRS OVER 10 MONTHS IN HOT , HIGH SALT ENVIRONMENT CAUSED CORROSSION THROUGH THE GAS GENERATOR CASE EXPOSING COMPONENTS OF THE COMPRESSOR STACK.SDR CA000118044Fuel Control · failed(CAN) SUSPECT CAUSE FOR HIGHER THAN NORMAL NGAT STARTUP.SDR CA000720002Rib · loose(CAN) EXCESSIVE LOOSENESS BETWEEN THE TWO HALVES OF THE FLAP AT THE CENTER HINGE ARM POSITION. THE RIBS ON EITHER SIDE OF THE HINGE ARM ARE ASSEMBLED TO THE ARM BY THE USE OF LONG MS20470AD5 SOLID RIVETS. IT WOULD APPEAR THAT THERE HAS BEEN SOME WORKING BETWESDR CA991209083Circuit Breaker · intermittent(CAN) START FAILURES RESOLVED WITH 5 AMP GENERATOR. RESET CIRCUIT BREAKER SHOWING AN INTERMITTENT OPEN CIRCUIT CONDITION. REPLACED.SDR CA991209072Rivet · loose(CAN) DURING INSPECTION OF THE ELEVATOR CONTROL SYSTEM, IT WAS NOTICED THAT THE PUSH PULL RIVETS WERE BLACK AND STAINED.THE PUSH PULL ROD WAS REMOVED FROM THE AIRCRAFT AND INSPECTED.AT THAT POINT WE DISCOVERED THAT THE RIVETS WERE LOOSE. THE RIVETS WERE REMOVSDR CA991112015Control Cable · broken(CAN) PILOT REPORTED AUTOPILOT NOT ENGAGING NORMALLY. AILERON SERVO CABLE FOUND BROKEN AT THE ENTRY INTO UPPER AILERON CABLE CLAMP. DUE TO LOSS OF TENSION , CABLES JUMPED OUT OF THEIR TRACKS, TWISTED AND JAMMED UNDER THE CABLE GUARD. BOTH CABLES EXHIBIT CRUSDR CA991028055Wire · shorted(CAN) INVERTER SYSTEM FAILED IN-FLIGHT. TROUBLESHOOTING FOUND WIRE FROM CVR INPUT SWITCH TO CIRCUIT BREAKER SHORTING TO ITS OWN SHIELDING. WIRE REPAIRED.SDR CA991028070Light · shorted(CAN) AFTER TAKEOFF, NOTICED FUMES IN COCKPIT. NON-ESSENTIAL ELECTRICS WERE SHUT OFF AND EMERGENCY DECLARED. CREW REPORTED THAT THEY HAD NOTICED WATER AROUND THE CIRCUIT BREAKER PANELS. ENGINEER INSPECTED THE AIRCRAFT AND FOUND SOURCE OF FUMES TO BE COMINSDR 99ZZZX4700Bleed Valve · leakingENGINE TEMPERATURE, N1 HIGH, TORQUE LOW, AND FUEL FLOW HIGH. INSPECTED FIRST STAGE COMPRESSOR SECTION BLADES FOR DAMAGE AND P3 LINES FOR CHAFED SECTIONS AND LOOSE FITTINGS. REPLACED BLEED VALVE FOR TROUBLESHOOTING PURPOSES. ALL ELSE CHECKED GOOD. PERFORMED SDR CA991028067Actuator · failed(CAN) AFTER LANDING, OUTBOARD FLAP FAILED TO RETRACT. ACTUATOR MANUALLY RUN IN AND SYSTEM SECURED. AIRCRAFT FERRIED TO MAIN BASE. REPLACED ACTUATOR. THIS UNIT HAS A 10,000 CYCLE LIFE.SDR CA990927067Pedal · cracked(CAN) DURING SCHEDULED MAINTENANCE, A CRACK WAS FOUND IN THE PILOT'S RT RUDDER PEDAL. THE CRACK RAN FROM THE BOTTOM EDGE OF THE CASTING TO THE PIVOT BUSHING AND THEN TO THE UPPER FORWARD HI-SHEAR RIVET.SDR CA991028068Connector · contaminated(CAN) SUSPECT WATER CAUSED SHORTING ON POWER INPUT PORTION OF CIRCUIT BREAKER PANEL - PERHAPS SOME WINDOW OPEN OR LEAK (HIGH WINDS CAN FORCE SIDE WINDOW TO OPEN SLIGHTLY). ALSO NOTED SOME COPILOT INSTRUMENT LIGHTS, ALSO NOT WORKING ( A SEPARATE PROBLEM). FOUSDR CA990927070Torque Tube · cracked(CAN) DURING ACCOMPLISHMENT OF SERVICE BULLETIN 2145, CRACKS WERE DETECTED ON BOTH RIGHT AND LEFT TORQUE TUBE ASSEMBLIES (P/N 115-610015-325). LEFT FOUND AT INBOARD SUPPORT (P/N 115-610015-1), RIGHT FOUND AT CENTER SUPPORT (P/N 115-610018-1). TORQUE TUBES RESDR 99ZZZX3928Mount · chafedUPON REMOVAL OF COMPRESSOR SECTION FROM RT SIDE, LOWER ENGINE MOUNT TUBE ASSY FOUND CHAFED ON TORSION TUBE BEYOND SERVICEABLE LIMITS. REPLACED ENTIRE MOUNT TUBE ASSY WITH SERVICEABLE MOUNT TUBE ASSY. CHAFE AREA DETERMINED TO BE IN VICINITY OF STAINLESS STEELSDR CA991004033Indicator · malfunctioned(CAN) ERRATIC FUEL QUANTITY DURING FLIGHT. NR 3-4 TRANSMITTERS AND INDICATOR REPLACED.SDR CA990907088Friction Lock · bent(CAN) PILOT REPORTED ENGINE SURGE DURING DESCENT WHEN PULLING POWER LEVER BACK AND THEN LETTING IT GO. INVESTIGATION FOUND THE PL FRICTION LOCK SHAFT WAS BENT, WHICH CAUSED FORWARD PRESSURE ON THE PL ASSEMBLY WHEN IT WAS PULLED BACK. NEW PARTS INSTALLED.SDR CA990728072Generator · failed(CAN) BOTH GENERATORS KICKED OFF SHORTLY AFTER TAKEOFF. FOLLOWING LONGER THAN NORMAL RUNNING ON THE GROUND WHILE WAITING DEPARTURE. ONE RESET, BUT THE OTHER WOULD NOT. RETURNED TO BASE CARRIED OUT. STARTER/GENERATOR REPLACED.SDR CA991112032Terminal Block · failed(CAN) NR 1 AFT BOOST PUMP WAS REPORTED AS INOPERABLE. ON INSPECTION OF THE CANISTER TYPE PUMP, THE TERMINAL BLOCK ON THE PUMP WAS FOUND SEVERELY BURNT AND MELTED AT THE PLUS TERMINAL. ABOUT ONE-HALF INCH OF THE A/C POWER WIRE INSULATION HAD ALSO BURNT OFF. SDR CA990728071Glow Plug · failed(CAN) DURING GLOW PLUG ROUTINE TEST, THE INBOARD PLUG WAS FOUND TO BE DEAD. SUBMITTER STATED THIS IS THE 4TH PLUG FROM BATCH 3B98 THAT HAS FAILED ALL WITH ONLY 100 HOURS.SDR CA990715011Manifold Assy · mismanufactured(CAN) PREVIOUSLY REPORTED TO P&W BY OPERATOR. BURRS AND MARKS HAVE BEEN FOUND IN THE PASSAGEWAYS OF THE TRANSFER TUBES. DIFFICULTIES ASSOCIATED IN ASSEMBLY IN WHICH THE OPERATOR FEELS COULD RESULT IN A FUEL HAZARD WHERE O-RINGS ARE DAMAGED AT INSTALLATION. SDR CA990728043Bearings · unapproved part(CAN) UNIT WAS DISASSEMBLED, IT WAS FOUND THAT THE BEARING INSTALLED WERE NOT OF THE MANUFACTURER'S TYPE.SDR CA990812008Duct · cracked(CAN) EXHAUST DUCT WAS NOTED TO HAVE A NUMBER OF CRACK INDICATIONS IN AND AROUND THE SEAM WELD AREA THAT ATTACHES THE POST P&W SB1430 INNER CONNECTION TO THE OUTER SKIN OF THE EXHAUST DUCT. CRACK INDICATIONS ARE LOCATED AROUND ENTIRE CIRCUMFERENCE.SDR AU990383Adapter · cracked(AUS) VERTICAL STABILIZER ATTACHMENT ADAPTER CRACKED THROUGH THE RIGHT ATTACHMENT BOLT HOLE.
Back to U/A Canada PT6A-27