Executive Airshare, LLC
Service difficulty reports · 36
Reports filed under designator XMXR by a repair station, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE submitter_designator = 'XMXR' AND submitter_type_code = 'B' ORDER BY difficulty_date DESC, sdr_id DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE submitter_designator = 'XMXR' AND submitter_type_code = 'B' ORDER BY difficulty_date DESC, sdr_id DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR XMXR2022083006Flow Valve · failedECS VALVE 1 FAIL - RESET ONCE ON GROUND WITH POWER CAME BACK 2 MIN LATERSDR XMXR2022083003Flow Valve · failedON POWER UP, ECS 1 VALVE FAIL CAS. POWER CYCLE AND ENGINE RUN MADE NO DIFFERENCESDR XMXR2022082403Starter Gen · leakingGEN 1 FLUCTUATING VOLTAGE.(28.6-25.1 APPX.) DURING CRUISE FLIGHT. OIL LEAKING FROM GEN OUTLET.SDR XMXR2022083005Flow Valve · failedBLEED 1 FAIL IN FLIGHTSDR XMXR2022083001Flow Valve · failedAT ALTITUDE BLEED 1 CYCLES BETWEEN OPEN AND CLOSE IN AUTOSDR XMXR2022082402Starter Gen · warning messageGEN 1 FAIL CASSDR XMXR202205232001Stand Off · bentWE EXPERIENCED MULTIPLE COCKPIT EFFECTS INCLUDING LOSS OF BATT 1 VOLTAGE INDICATION, SWPS FAIL, PUSHER TEST FAIL, ENGINE NO DISPATCH, SAT, TAT, ISA, SHOWING RED X’S, ETC. TROUBLESHOOTING THIS ISSUE LED US TO A DAMAGED WIRE BUNDLE FORWARD OF THE PILOTS LEFT RSDR XMXR2022083004Flow Valve · failedECS 1 VALVE FAIL CASSDR XMXR2022083002Flow Valve · failedINTERMITTENT ECS2 FAIL CASSDR XMXR2022082401Shaft · excess play#1 ENGINE VIBRATION REPORTED ON START UP BY PILOT. AFTER REMOVAL - MECHANIC REPORTED SUSPECT SHAFT SIDE PLAYSDR XMXR20201214002Shutoff Valve · failedECS 2 FAIL CAS.SDR XMXR20201118006Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS BATTERY PACK.SDR XMXR20201118002Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS NR 2 AFT BATTERY PACK.SDR XMXR20201118001Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED BATTERY NR 1 FWD BATTERY PACK.SDR XMXR2020121408Valve · failedBLEED 2 FAILED IN FLIGHT. RESET AND FAILED A SECOND TIME.SDR XMXR20201118008Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS BATTERY PACK.SDR XMXR20201118007Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS BATTERY PACKSDR XMXR20201118005Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS NR 2 AFT BATTERY PACK.SDR XMXR20201118004Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS NR 2 AFT BATTERY PACK.SDR XMXR20201118009Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS BATTERY PACK.SDR XMXR20191211010Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR20191211020Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR20201118003Battery Pack · failedEMERGENCY LIGHTS FLICKERING. REPLACED EMERGENCY LIGHTS NR 2 AFT BATTERY PACK.SDR XMXR2020121405Valve · failedBLEED 2 FAIL CAS.SDR XMXR2020121409Valve · failedAFTER SEVERAL LANDINGS, EACH TIME BLEED 2 FAIL CAS FAIL, THEN CAS WOULD GO AWAY.SDR XMXR20191211024Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR20191211023Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR2020121401Flow Valve · failedBLEED 1 LEAK CAS.SDR XMXR2020121407Valve · failedMULTIPLE BLEED 1 FAIL CAS MESSAGES APPEARED IN FLIGHT.SDR XMXR2020121406Valve · failedBLEED 2 FAIL CAS IN FLIGHT.SDR XMXR2020121402Shutoff Valve · failedECS VALVE 1 FAIL.SDR XMXR20191211019Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR2020121404Valve · failedECS 2 VALVE FAIL CAS IN FLIGHT.SDR XMXR2018022200002Precooler · brokenDURING ROUTINE INSPECTION OF PRE-COOLER ASSEMBLY FOUND INTERNAL VANES BROKEN OFF PRE-COOLER ASSEMBLY BLOCKING AIRFLOW OVER COOLING FINS. AFTER MORE RESEARCH FOUND HAS A SERVICE LETTER ADDRESSING THIS ISSUE. SL 505-36-0003. AFFECTED PRE-COOLER P/N 10965000-105 SDR XMXR2018022200001Precooler · brokenDURING ROUTINE INSPECTION OF RT PRE-COOLER ASSEMBLY FOUND INTERNAL VANES BROKEN OFF RT PRE-COOLER ASSEMBLY BLOCKING AIRFLOW OVER COOLING FINS. AFTER MORE RESEARCH FOUND HAS A SERVICE LETTER ADDRESSING THIS ISSUE. SL 505-36-0003. AFFECTED RT PRE-COOLER P/N 1096SDR XMXR2018021500001Precooler · leakingPNEUMATIC SYSTEM RT BLEED AIR PRE-COOLER P/N 9914402-4 OR 8161-2 S/N S4883T0680 FOUND AREAS ON PRE-COOLER ASSEMBLY THAT HAVE BEEN LEAKING BLEED AIR INTO PYLON AREA. PART HAS A LIFE LIMIT OF 3500 HOURS OR 108 MONTHS WHICHEVER OCCURS FIRST. DEFECTIVE PART ONLY H
Back to Executive Airshare, LLC