JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202009209010Valve · inoperativeAIRCRAFT WAS GROUNDED: AT FL410, RUMBLING NOISE THROUGHOUT ENTIRE AIRCRAFT. LEFT PACK AUTO SHUTDOWN, BURNING SMELL THROUGHOUT AIRCRAFT. CABIN AIR COMPRESSOR L2 AND L1 STATUS MESSAGE LT PACK EICAS MESSAGE. DECLARED EMERGENCY AND RETURNED TO DFW. FOUND CAC ASDR UIEA2020092182018A/C Pack · inoperativeLEFT PACK INOP AIR CONDITIONING PACKS -200/300, NOTIFY DISPATCH, ER RESTRICTED R-60. TRANSFERRED TO MDDR 134625, IAW MEL 21-51-01-01 CAT C DUE DATE 28 SEP 20 DGG PROCEDURE C/W ACL 0716Z. PERFORMED VISUAL INSPECTION OF PACK BAY AREA, IAW FIM 21-00 TASK 802, FSDR P5CA2020091800316Controller · faultedRIGHT PACK TEMP EICAS IN FLIGHT. PERFORMED PTC BITE TEST, FOUND CONTROLLER FAULT. REMOVED AND REPLACED CONTROLLER, IAW AMM 21-51-4.SDR SIMA20200917003A/C Pack · overheatedABORTED TAKEOFF PACK 2 OVERHEAT MSG. C/A FLIGHT CREW PLACARDED PACK 2 MEL 21-30 AUTH 090257-C MOC ID 373623.SDR P5CA2020091400312Controller · malfunctionedRIGHT PACK TEMP EICAS AFTER TAKEOFF, LEFT PACK DEFERRED. RETURN TO ICN. FOLLOWED FIM TASK 21-51 FAULT TREE 844 PERFORMED T/S, FOUND RT STANDBY CONTROLLER FAULT. REMOVED AND REPLACED RT STANDBY CONTROLLER AND CHECKED OK, NO FAULT FOUND PER AMM 21-51-14/401. SDR ASAA2020091553181Acm · failedRIGHT PACK LIGHT ILLUMINATED AT GATE WITH BOTH PACKS ON. GROUNDED-YES. RAN BITE CHECK AND FOUND PACK TCV FAULTED. REMOVED AND REPLACED TEMP CONTROL VALVE, REF B737-900 AMM 21-21-10. OPS CHECK GOOD. CONTINUED RUNNING PACK AND FOUND THE AIR CYCLE MACHINE TOSDR SWIA202053332Bypass Valve · crackedAFT EQUIPMENT BAY RT ACM SUPPORT STRUCTURE PLATE ASSEMBLY AT APPROXIMATELY FS 708.0 AND BL 18 RT HAS CRACKS AT INBOARD AFT MOUNT BOLT. C-CHECK RO 10/13/2020. REPLACED CRACKED PLATE ASSEMBLY ON RT ACM SUPPORT STRUCTURES WITH NEW PN 601R95222-1 PO T- 56457, RESDR P5CA2020091400311Controller · malfunctionedLT PACK INOP, COCKPIT WOULD NOT COOL DOWN, REMAINED OVER 33'C AT FL 340 ENTIRE FLIGHT. TRANSFERRED TO MDDR 134263 IAW MEL 21-51-01-01, CAT C. REMOVED AND REPLACED LT PACK TEMP CONTROLLER AND OPER CHECKED OK, NO FAULT FOUND, PER AMM 21-51-14/401. A/C OK FOR SDR VNAA2020091211101A/C Pack · odorOILY SMELL COMING FROM THE PACKS. INVESTIGATED OIL SMELL COMING FROM PACKS. COULD NOT REPLICATE PROBLEM. FOUND NO DEFECTS AT THIS TIME. OPS CHK OF A/C SYS SOURCING FROM APU & BOTH ENG ABOVE IDLE. NO ODORS DETECTED AT THIS TIME.SDR COEA2020091002811Acm · failedFLIGHT 1704, ENROUTE HNL-OGG/AIR TURNBACK DISCREPANCY. NO PRESSURIZATION ON CLIMB OUT, DUCT TEMP OVER 50 DEGREES C. AIRCRAFT WAS RETURNED TO HNL, NO EMERGENCY DECLARED. LANDED WITHOUT INCIDENT. MAINTENANCE DEFERRED. MAINTENANCE REPLACED THE AIR CYCLE UNITSDR IPXA2020091106068A/C Pack · odorINSPECTION TYPE: N/A ON DESCENT FROM FL370 EXPERIENCE A STRONG ACRID SMELL OF SMOKE, AS IN A FOREST FIRE SMELL, THIS MAY BE MISTAKEN AS AN A/C FIRE BY THE SUBSEQENT, REF AMM 21 00 21 102 030. REMOVED OF SMOKE SMELL FROM PNEUMATIC SYSTEM ACCOMPLISHED.SDR VNAA2020091111102Acm · failedFOUL ODOR COMING FROM PACKS. TROUBLESHOT PER FIM. INSPECTED APU AND LOAD CONTROL VALVE, FOUND NO EVIDENCE OF OIL CONTAMINATION. RAN PACKS IN ALL BLEED CONFIGURATIONS WITH AND WITHOUT ENGINES AND DETERMINED SMELL TO BE PREVALENT WITH LT PACK. SUSPECT LT ACMSDR P5CA2020090860301Controller · malfunctionedLT PACK TEMP EICAS INDICATION ON DEPARTURE. RAN QRH TEMP EICAS AND INOP MSG EXTINGUISHED. BIT ON LPTC SHOWS CONT FAULT + RAI ACTUATOR, RESET + VERIFIED C/O IAW AMM 21-51-00. DEFECT CLEARED SUBS PACK OPS DURING TRANSIT SATIS. DUE HISTORY APPLIED MEL 21-51-0SDR UIEA2020090801960Warning Message · false activationHI FLOW INHIBIT STATUS MESSAGE. PERFORMED FIIM 21-51 FT 813 UP TO STEP 21, MESSAGE CLEARED. NO FURTHER DEFECTS NOTED. OPERATED LT & RT PACK FOR 1 HR IAW 21-51-00, MESSAGE DID NOT APPEAR. OPERATIONS CHECK NORMAL.SDR ASAA2020090853139Switch · inoperativeDURING "AFTER START" PROCEDURE RT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL, EXTINGUISHED ON MASTER CAUTION RESET. GROUNDED - YES. REPLACED TURBINE INLET OVERHEAT SWITCH, PER AMM 21-51-41 AND OPS CHECKED GOOD PER TSR 709929. CLEARS MEL 21-32B, PLACARDSDR GTIA2020090735347A/C Pack · contaminatedDIRTY SOCK ODOR REPORTED BY FLIGHT ATTENDANT IN FORWARD CABIN ON DESCENT, PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED). PERFORMED LEVEL A DECONTAMISDR ASAA2020090843137Actuator · failedON MASTER CAUTION RECALL, LEFT PACK LIGHT ILLUMINATED. EXTINGUISHED ON MC RESET. GROUNDED - YES. LEFT RAM AIR ACTUATOR FAULT SHOWN. R & R LEFT RAM ACTUATOR, REF B737-800 AMM 21-51-21. TEMP CONTROLLER BITE CHK GOOD. MASTER CAUTION RESET NORMAL.SDR P5CA2020090410300Actuator · malfunctionedON CLIMB OUT RECEIVED "L PACK TEMP" EICAS MESSAGE. COMPLIED WITH QRH.(<P>PACK TEMP CONT "AUTO" INOP. ITEM DEFERRED PER MEL 21-51-03-01, MDDR #133749, CAT 'C'.</P><P>LP 1153914 ITEM 7: PTC BITE SHOWS "RAM INLET ACTR" FAULT, SO REMOVED & REPLACED L PACK RAM AIR SDR ASAA2020090331129Actuator · intermittentDURING CRUISE THE PACK LIGHT ILLUMINATED. RAN QRH AND LIGHT WOULD NOT STAY EXTINGUISHED. PACK TURNED OFF PER QRH FOR REMAINDER OF FLIGHT. GROUNDED - YES. REF B737-900 FIM 21-53 TASK 820, COMPLETED STEPS A THRU E AND F (1&2). DURING RAM AIR SYSTEM-OPERATIOSDR DALA2020090202917Condenser · crackedCREW NOTICED ODD SMELL AND HAZE IN COCKPIT AT FL 410, HAZE DISSIPATED QUICKLY, CALLED ATL MAINTENANCE TO TROUBLE SHOOT. TURNED OFF TRIM SWITCH AND HAZE RETURNED. RESET TRIM SWITCH AND HAZE WENT AWAY, TURNED OFF RIGHT PACK NO HAZE BUT SMELL STILL PRESENT. MAINTSDR UIEA2020090101906A/C Pack · malfunctionedLEFT AC PACK NOT COOLING PROPERLY VERY DIFFICULT TO MAINTAIN CABIN TEMP ON GROUND ,,REF PREV WRITE UP ON PAGE 1140366(<P>INSPECTED LEFT A/C PACK COMPONENT BITE IS DONE ON BOTH ZONE TEMP CONTROL UNIT AND LEFT PACK TEMP CONTROL,PACK AND TRIM VALVES OPERATIONAL CSDR ASAA2020082933127A/C Pack · malfunctionedLT PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL AND GOES OUT ON MC RESET. GROUNDED - YES. ACCOMPLISHED PACK TEMP CONTROL BITE PROCEDURE ON NR 1 AND NR 2 CONTROLLERS, BOTH TESTS PASSED NO FAULTS NOTED. VERIFIED GREEN LIGHT ON, NO LRU FAULTS-ON SRADA EXIT SDR ASAA2020083123106Actuator · failedRIGHT PACK LIGHT ILLUMINATED ON CLIMBOUT. RAN CHECK LIST PACK LIGHT RESET, OPS NORMAL THEREAFTER. GROUNDED - YES. ACCOMPLISHED B737-900 FIM 21-53 TASK 820 STEP 820A- F2A2, NO DEFECTS FOUND. PER FIM 21-53 TASK 820 REMOVED AND REPLACED RAM AIR EXHAUST ACTUATSDR MASA2020082710558Acm · failedCAPTAIN REPORTED SMOKE/ODOR IN THE COCKPIT AFT A L PACK AUTO FAIL CAUTION MESSAGE. AFTER SHUTTING DOWN THE LT PACK THE SMOKE AND ODOR DISSIPATED AND THE FLIGHT CONTINUED WITH THE LT PACK OFF. MAINTENANCE DETERMINED THE CAUSE OF THE SMOKE/ODOR WAS DUE TO FAILURSDR SWIA202052081A/C Pack · failedLOST THE LEFT PACK AT CRUISE, FL240. STARTED DESCENT. IAW QRH PRESSED EMERGENCY DEPRESS AT 17000 FEET. PAX O2 MASKS DEPLOYED. FLIGHT 5171.SDR ASAA2020082753088Warning Light · false activationON RECALL RT PACK LIGHT ILLUMINATED. GROUNDED - YES. ACCOMPLISHED PACK ZONE TEMP CONTROLLER BITE B737-900 AMM 21-61-00, GRD VERIFICATION SUCCESSFUL. OPS CHECK NORMAL.SDR ASAA2020082543078Warning Message · false activationON CLIMBOUT RIGHT PACK ILLUMINATED. RAN QRH AFTER COOLING DOWN PACK RESET. GROUNDED - YES. PERFORMED PZTC BITE, REF B737-900 FIM 21-62 TASK 801, NO FAULTS ON EITHER PZTC. REMOVED UNION FROM ACM TO INSPECT BLADES WITH BORESCOPE, NO DAMAGE FOUND. REINSTALLESDR UIEA2020082401855Warning Message · false activationL PACK TEMP EICAS MESSAGE DISPLAYED DURING CLIMB L PACK OFF ALSO DISPLAYED PERFORMED LH PACK TEMP CONTROLLER BITE PROCEDURE PER B 767 AMM 21-51-00. NO CURRENT FAULTS PRESENT. NO PREVIOUS FAULTS LOGGED ON CONTROLLER. BOTH PACKS OPERATING SATISFACTORY AT THIS TISDR ASAA2020082503074Warning Message · false activationON MC RECALL LT PACK LIGHT ILLUMINATED. FOLLOWED QRH, EXTINGUISHED AFTER MC RESET. GROUNDED - YES. NR 1 ZONE TEMP CONT LOGGED SRADA EXIT FAULT. PERFORMED PACK TEMP CONTROL BITE PROCEDURE ON THE NR 1 & 2 ZONE TEMP CONTROL UNIT, PER B737-900 FIM 21-62 TASK 8SDR UIEA2020082431851Warning Message · false activation"R PACK OFF" EICAS MESSAGE @ 4000'. PERFORMED BITE OPERATIONAL CHECK OF PACK SYSTEM PER AMM 21-00-00. OPS CHECK GOOD, NO MESSAGES. COULD NOT DUPLICATE AT THIS TIMESDR UIEA2020082621848Control Valve · failedRH PACK INOP. WILL NOT RESET. REMOVED AND REPLACED THE NR 2 PACK LOW LIMIT CONTROL VALVE IAW AMM 21-51-11/201. OPS AND LEAK CHECKED GOOD.SDR ASAA2020082423059Sensor · faultedLT PACK LITE ILLUMINATES ON RECALL, EXTINGUISHES ON RESET -FL350. GROUNDED - YES. PERFORMED PACK ZONE TEMP CONTROL BITE, REF B737-900 FIM 21-62 TASK 801. FOUND RAM AIR SENSOR SRADA EXIT FAULT LOGGED. PERFORMED LT RAM AIR EXIT ACTUATOR FAULT ISOLATION, REF SDR UIEA2020082401857Warning Message · false activationAFTER LANDING, RECEIVED A FWD EQUIP VALVE ADVISORY MESSAGE. PERFORMED BITE TEST OF EQUIPMENT COOLING SYSTEM CONTROLLER. NO FAULTS NOTED IAW AMM 21-58-00.SDR GTIA2020082435322A/C Pack · contaminatedFUME EVENT PACK 1 (ONE) ON DESCENT TO MSY APPX F000. APPLIED SUPPLEMENTAL PROCEDURE PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED. PERFORMED DECONSDR VNAA2020082311102Acm · failedSMOKE IN COCKPIT. (CREW REPORTED SMOKE IN COCKPIT AND CABIN. NOXIOUS SMELL. APU ON, BOTH PACKS ON). INVESTIGATED LH PACK AND FOUND DAMAGE TO ACM AND TEMP CONTROL VALVE. REMOVED AND REPLACED TEMP CONTROL VALVE IAW CRJ 700 AMM 21-51-20-000/400-801.SDR IPXA2020082159281A/C Pack · odorON DECENT BETWEEN 10,000 AND 8000 FEET ENCOUNTERED DIRTY WATER SOCK SMELL FROM AIR CONDITIONING.RAN BOTH PACKS FOR 1 HOUR IAW AMM 21- 00-00-862-001. NO ODOR DETECTED, COULD NOT DUPLICATE MALFUNCTION. OK TO CONTINUE.SDR VNAA2020082311101Acm · failedFLIGHT 5316 CLT-LYH DECLARED EMERGENCY ON FINAL APPROACH FOR SMOKE IN THE CABIN, AIRCRAFT WAS BALE TO LAND SAFELY AND TAXI OFF RUNWAY NO ISSUES. AIRCRAFT MET BY FIRE AND RESCUE ON TAXI WAY NO INDICATION OF FIRE. AIRCRAFT PROCEEDED TO TAXI TO GATE AND DEPLANE NSDR UIEA2020082491819Controller · malfunctionedR PACK TEMP EICAS MSG (PACK TEMPERATURE CONTROL SYSTEMS (-200/-300), AUTO MODE) TRANSFERRED ITEM TO MDDR 133072 PER MEL 21-03-01, CAT C, DUE 28 AUG 20 MCC ALEY DISP SP 2222Z. REMOVED AND REPLACED RH PACK TEMP CONTROLLER BOX REF AMM 21-51-14. OPS CHECKS OK. THISDR UIEA2020082101839Sensor · malfunctionedRT PACK PRIMARY HEAT EXCHANGE TEMP SENSOR DATA MISSING REMOVED AND REPLACED TEMP SENSOR IAW B767 AMM 21-52-08, OPS CHECKED GOODSDR UIEA2020082101838Warning Light · false activationR PACK TEMP LIGHT ILLUMINATED ON CLIMB OUT PERFORMED B.I.T.E TEST IAW AMM REF 21-51-00. NO FAULTS FOUND. SYSTEM OPS NORMAL.SDR ASAA2020082083041A/C Pack · malfunctionedSHORTLY AFTER REACHING TOP OF CLIMB THE MASTER CAUTION AND LEFT PACK LIGHTS ILLUMINATED. WE RAN THE QRH, WHICH ALLOWS A RESET AND THE PACK LIGHT WENT OUT. AROUND 3 MINS LATER IT CAME BACK, LEADING US TO SECURE THE PACK. LEFT PACK TEMP INDICATED MID 40'SC. SDR KCSA2020081812Sensor · failedEQUIPMENT COOLING. REMOVED AND REPLACED FLIGHT DECK. LOW FLOW DETECTOR IAW B747-400 AMM CHAPTER 21-58-02. PERFORMED OPS CHECK IAW 21-58-00. OPS CHECK GOOD. PERFORMED EQUIPMENT COOLING TASK IAW CHAPTER 21-58-00-705-062. OPS CHECK GOOD. AIRCRAFT OK FOR CONTINUEDSDR UIEA2020082171804Warning Message · false activationEICAS L PACK TEMP(<P>PERFORMED FIM 21-51 FT 844 PACK TEMP CONTROLLER BITE. NO FAULTS ON BIT OR PREVIOUS F/L. VERIFY WAS A GO. FOLLOWED FIM UP TO #8. SYSTEM IS OK FOR SERVICE. RAN PACK FOR 1 HOUR IAW AMM 21-51-00 NO FAULTS NOTED.SDR ASAA2020081633038Warning Light · false activationMASTER CAUTION AIR COND LIGHT ILLUMINATED AFTER RUNNING DESCENT CHECKLIST. LEFT PACK LIGHT ILLUMINATED. LIGHT EXTINGUISHED AFTER PRESSING MASTER CAUTION - PRESS TO RESET, RAN QRH 12.2. GROUNDED - YES. NR 1 ZONE CONT LOGGED RAM AIR ACT FAULT. FAULT CLEAREDSDR ASAA2020081863033Actuator · inoperativeLEFT PACK ILLUMINATED ON RECALL, LIGHT EXTINGUISHES WHEN MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED BOTH LT RAM AIR ACTUATORS, REF B737-900 AMM 21-51-21 AND 21-51-27. OPS CHECK GOOD AND BITE TEST GOOD, NO FAULTS AT THIS TIME.SDR ASAA2020081733021Control Valve · failedAFTER START RT PACK LIGHT ILLUMINATED ON RECALL. RESET WITH MC RECALL. GROUNDED, YES. REF B737-900 FIM 21-62 TASK 801, 21-62 TASK 831. NR 2 ZONE TEMP CONTROLLER SHOWS: TCV (THIS PACK). REQUIRES TCV (V141). REMOVED AND REPLACED ZONE 2 TEMPERATURE CONTROL VSDR UIEA2020081701802A/C Pack · overheatedLEFT PACK OVER HEAT ILLUMINATED HISTORY REMOVED, INSPECTED, AND REINSTALLED THE LH PACK OVERHEAT SWITCH REF B767 AMM 21-51-18. NO DEFECTS NOTED AT THIS TIME.SDR GTIA2020081735310A/C Pack · odorON FINAL APP PACK 1 GAVE OF MUSTY SOCKS SMELL PACK 1 OFF SMELL WENT AWAY ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED TSM #05-50-00-SDR UIEA2020081731766Controller · malfunctionedR PACK TEMP REMOVED AND REPLACED RT TEMP SENSOR TS 199 AND STBY SENSOR IAW 21-51-08 (OFF PART: PN624014-2, NSN). NO HELP. TRANSFERRED TO MEL 21-53-03-01, AUTO MODE, REMOVED AND REPLACED RH PACK TCV IAW AMM 21-51-12 AND REPLACED RT PACK CONTROLLER IAW AMM 21-5SDR UIEA2020081421760Warning Message · false activationRIGHT PACK TEMP EICAS DURING CRUISE AT FL 340 1716Z(<P>ACCOMPLISHED FIM 21-51-00-810-877-001. RESET R PACK TEMP CONTROLLER AND OPS CHECKS GOOD PER MM 22-51-00. NO FAULTS.<BR /></P>)
Back to JASC 2150