SDR ASAA1058001Control Valve · stuckLEFT PACK LT/AIRCOND LT/ MASTER CAUTION ILLUMINATED DURING RECALL ON AFTER START CHECK. FOUND ON ZONE TEMP CONT 1 TCV THIS PACK FAULT. FOUND VALVE TO BE STUCK OPEN. REPLACED LT TEMP CONTROL VALVE. TEMP CONTROL VALVE TEST OPS CHECK GOOD REF AMM 21 51 10 400Jun 21, 2010 · N585AS · Boeing 737890SDR ASAA1057920Warning System · malfunctionedCONT CABIN LIGHT (ZONE TEMP) ILLUMINATES ON RECALL. PERFORMED FIM 21 62 00 810 842 OPERATED PACK (L) ZONE LIGHT DID NOT ILLUMINATE AND NO FAULT ON CONTROLLER, ALL GROUND TESTS PASS.Jun 12, 2010 · N557AS · Boeing 737890SDR ASAA1057895Unknown · malfunctionedLEFT PACK LIGHT ILLUMINATED ON RECALL. QRH WAS ACCOMPLISHED AND LIGHT EXTINGUISHED AFTER RESET. PERFORMED PACK / ZONE TEMPERATURE CONTROLLER BITE CHECK NO FAULTS NOTED PER AMM 21 62 00 810 801. CREW REPORTED NO PACK LIGHT ON RECALL. GROUND VERIFICATION COMJun 4, 2010 · N519AS · Boeing 737890SDR SIMA201015503Coupling · tornON FLIGHT 4523 THE CREW REPORTED, RECEIVED BLEED NR 2 LEAK WITH LOSS OF PRESSURIZATION. THE CREW DECLARED AN EMERGENCY AND DIVERTED TO BDL. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. DURING VISUAL INSPECTION OF THE NR 2 PAJun 3, 2010 · N823AE · Emb EMB135KLSDR HALA2010060200237Controller · malfunctionedETOPS SIGNIFICANT SYS - COMPARTMENT TEMP CONTROLLER INOP LIGHTS ILLUMINATED IN ALL ZONES INCLUDING FLIGHT DECK. FOUND ZONE TEMP CONTROLLER W/ HARD CONTROLLER FAULT WILL NOT RESET. T/S IAW FIM 21-61-00/10 FIG 103, COMPLETED RESISTANCE CHECK IAW BL 21. NO TROUJun 2, 2010 · N593HA · Boeing 76733ASDR MYWA100083Control System · inoperativeETOPS SIGNIFICANT SYSTEM - AUTO TEMP CONTROL DOES NOT OPERATE.May 31, 2010 · N734MA · Boeing 7378Q8SDR UALA2010052601801Heat Exchanger · failedCABIN PRESSURE WARNING. FLIGHT DESCENDED TO FL110. REPLACED SECOND HEAT EXCHANGER. LT PACK OPS CHECK GOOD. COOLS AS GOOD AS RT PACK.May 26, 2010 · N534UA · Boeing 757222SDR ASAA1057863Control Valve · malfunctionedAFTER ENGINE START LT PACK LIGHT ILLUMINATED & WOULD NOT EXTINGUISH PER QRH CHECKLIST COMMANDS. FOUND PRIMARY TEMP CONTROL VALVE FAULT. REPLACED L PACK TEMP CONTROL VALVE REF AMM 21 51 10 OPS & LEAK CHECK NORMAL. GROUND VERIFICATION CHECK ACCOMPLISHED. LT May 25, 2010 · N585AS · Boeing 737890SDR ASAA1057864Unknown · malfunctionedLEFT "PACK" LIGHT ILLUMINATED AT MASTER CAUTION CHECK BEFORE LANDING. LIGHT GOES OFF WHEN M/C IS RESET. FOUND NR 1 ZONE TEMP CONTROLLER W/ "THIS PACK" TCV FAULT. FAULT CLEARED UPON SUCCESSFUL COMPLETION OF PACK/ZONE TEMP CONTROL BITE TEST. L "PACK" LIGHT NMay 24, 2010 · N585AS · Boeing 737890SDR ASAA1057830Unknown · malfunctionedON TAXI OUT AFTER ENGINE START ON MASTER CAUTION RECALL. "AIR COND" AND CONTROL CABIN "ZONE TEMP" ILLUMINATED AND EXTINGUISHED ON MASTER CAUTION RESET. CREW REPORTED NO FAULT ON RECALL AFTER LANDING. PERFORMED BITE TEST ON BOTH PACK/ZONE CONTROLLER. REF FIMay 17, 2010 · N560AS · Boeing 737890SDR ASAA1057798Filter · dirtyAFTER ENGINE START AFTER RECALL THE CONT CAB ZONE TEMP LIGHT CAME ON. IT WENT OUT WITH MASTER CAUTION RESET. GROUNDED YES. BITE OF BOTH ZONE TEMP CONTROLLERS SHOW FLT DECK CABIN SENSOR FAULT. FOUND FILTER IN CONTROL CABIN CLOGGED. CLEANED FILTER & GROUND OMay 12, 2010 · N587AS · Boeing 737890SDR ASAA1057792Filter · dirtyZONE TEMP FOR CONT CAB ILLUMINATED ON RECALL. BITE CHECKED TEMP CONT IAW 21 61 00 BOTH FAULTED CONT CAB SENSOR FOUND FILTER DIRTY CLEANED IAW MM 21 61 06 BOTH CONTROLLERS RESET WITH NO FURTHER FAULTS.May 9, 2010 · N517AS · Boeing 737890SDR P90R7138Controller · failed(P90R) PILOT REPORTED THAT AFTER TAKEOFF, THE PASSENGERS REPORTED SMOKE IN THE CABIN AND MADE A PRECATIONARY LANDING. HE STATED THAT THEY DID GROUND RUNS AND COULD NOT DUPLICATE THE PROBELM. DURING OUR TROUBLESHOOTING, WE FOUND THE ACFT NOT PRODUCING COLD AIR.May 5, 2010 · N545LC · Beech 200BEECHSDR ASAA1057752Unknown · malfunctionedLEFT PACK LIGHT ILLUMINATED ON RECALL DURING LANDING CHECKLIST. VERIFIED ISSUE. BITE SHOWS TCV FAULT ON NR 1 ZONE TEMP CONTROLLER. BITE OF CONTROLLER RESETS FAULT. GROUND VERIFICATION CHECKS NORMAL REF AMM 21 61 20.Apr 20, 2010 · N557AS · Boeing 737890SDR ASAA1057552Control Valve · malfunctionedCONTROL CABIN ZONE TEMP LIGHT CAME ON DURING FLIGHT. RESETS ON RECALL OPS NORMAL. REPLACED CONTROL CABIN TEMP CONTROL VALVE.Mar 20, 2010 · N587AS · Boeing 737890SDR ASAA1057554Valve · malfunctionedON RECALL, AIR COND CONTROL CABIN LIGHT REMAINS ILLUMINATED. THE LIGHT EXTINGUISHES ON RESET. ACCOMP PACK/ZONE TEMP CONT BIT NR 2 FAULTED V143 (FLT DECK TRIM) NR 1 NO FAULTS. REPLACED FLT DECK TRIM VALVE ASSY, OPS CHECK GOOD.Mar 19, 2010 · N577AS · Boeing 737890SDR ASAA1057553Valve · malfunctionedWHEN RECALL IS PUSHED ZONE TEMP LIGHT FOR CONTROL CABIN ILLUMINATES. FOLLOWED QRH TRIP RESET PUSHED LIGHT REMAINS ON. MASTER CAUTION RESET IS PUSHED LIGHT GOES OUT. FAULT CODE 216 212 00. VERIFIED NR 2 ZONE TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT.Mar 18, 2010 · N558AS · Boeing 737890SDR ASAA1057551Warning System · activatedCONTROL CAB ZONE TEMP LIGHT ILLUMINATES DURING RECALL.Mar 18, 2010 · N519AS · Boeing 737890SDR ASAA1057546Valve · inoperativeCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES UPON RECALL EXTINGUISHES UPON RESET. REPLACED FLT DECK TRIM AIR VALVE PER AMM 21 61 21 000 801 AND 21 61 21 400 801 LEAK CHECK GOOD AND PERFORMED BITE PER AMM 21 62 00 810 801, NO FAULTS NOTED.Mar 17, 2010 · N587AS · Boeing 737890SDR ASAA1057531Valve · defectiveWHEN "RECALL" IS SELECTED "ZONE TEMP" IS ANNUNCIATED ON THE OVERHEAD PANEL. QRH PROCEDURE WAS FOLLOWED THE TEMP DID NOT INCREASE WHEN THE MASTER CAUTION WAS SELECTED. ALL WAS RESET UNTIL "RECALL" WAS RE-SELECTED DUCT TEMP DID NOT INCREASE DURING THIS PROCESSMar 13, 2010 · N577AS · Boeing 737890SDR ASAA1057532Warning System · malfunctionedON TAXI FROM SEA ZONE TEMP FOR CONT CAB ILLUMINATED ON RECALL. PROCEDURES FOR FLIGHT CREW PLACARD FOLLOWED FOR MEL 21 21F. SEA MAINTENANCE NOTIFIED. COULD NOT DUPLICATE DEFECT. OPERATED BOTH PACKS AND PERFORMED BITE CHECK'S ON BOTH CONTROLLERS BOTH SHOW "GMar 13, 2010 · N519AS · Boeing 737890SDR UALA2010031500870Valve · faultyF-D AIR COND SHOWS NO TARGET TEMP. RESET NO HELP. CANNOT MOVE TRIM VALVE. REPLACED FLT DECK TRIM VALVE.Mar 13, 2010 · N224UA · Boeing 777222SDR ASAA1057492Controller · intermittentRIGHT PACK LIGHT ILLUMINATES ON RECALL RESETS WHEN MASTER CAUTION IS RESET. PERFORMED PACK /ZONE TEMP CONTROLLER BITE TEST PER M/M 21 61 00 ON NR 2 CONTROLLER CONFIRMED FAULT FOUND INTERMITTENT FAULT ON RAM AIR ACTUATOR REPLACED SAME PER M/M 21 51 21. STILL Mar 5, 2010 · N566AS · Boeing 737890SDR NSVA201060Control Valve · faultyLEFT OVERTEMP LIGHT ILLUMINATED IN FLIGHT. REMOVED AND REPLACED LT DUAL TEMP CONTROL VALVE.Mar 4, 2010 · N191MJ · Saab 340BSDR UALA2010033001065Valve · faultyTRIM AIR VALVE ZONE B INOPERATIVE. DE-ACTIVATED ZONE B TRIM AIR VALVE IN CLOSED POSITION. REPLACED TRIM AIR VALVE AND OPS AND REVERSE MEL 2161P.Mar 2, 2010 · N209UA · Boeing 777222SDR ASAA1057476Unknown · malfunctionedON RECALL RIGHT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL. RIGHT PACK LOGGED TCV FAULT. PERFORMED FIM 21 62 TASK 801. PACK TEMP CONT BITE CHECK FAULT CLEARED. GROUND VERIFICATION CHECK GOOD OF RT PACK REF MM 21 00 00 800. SEAMC NOTIFIED.Feb 28, 2010 · N559AS · Boeing 737890SDR ASAA1057469Valve · faultyLEFT PACK LIGHT ILLUMINATED ON RECALL, QRH FOLLOWED, WILL NOT RESET. BITE CHECK SHOWS TCV FAULT. REPLACED TCV REF AMM 21 51 10, OPS CHECKS GOOD. LEAK CHECK GOOD. PACK LIGHT REMAINS EXT UPON RECALL.Feb 27, 2010 · N518AS · Boeing 737890SDR 2010FA0000246Controller · failedON TAKEOFF ROLL THE CREW NOTED A STRONG ELECTRICAL BURNING ODOR IN THE COCKPIT. THE TAKEOFF WAS ABORTED. THE ACFT WAS SHUTDOWN, ELECTRICAL POWER WAS TURNED OFF AND THE BATTERIES WERE DISCONNECTED. THE ACFT WAS THEN TOWED BACK TO THE HANGAR. THE SOURCE OF TFeb 23, 2010 · N127SF · Amd FALCON900EXSDR ASOA20100452Bypass Valve · failedREMOVED DEFECTIVE LT DUAL BYPASS VALVE AND INSTALLED REPAIRED UNIT. LEAK AND OPS CHECK GOOD AT THIS TIME WORK DONE IAW AMM 21-61-31 PACK NOW OPERATES IN MANUAL MODE ONLY DEFER CLEARED PLACARD REMOVED REF AFDL 527321-1 FOR OPERATION. (CLOSED)Feb 22, 2010 · N834AS · Cndair CL6002B19SDR ASAA1057449Valve · faultyCONT CAC "ZONE TEMP" ILLUMINATED UPON RECALL FOLLOWS QRH. CLEARS WITH MASTER CAUTION RESET. NR 2 PACK/ZONE TEMP CTRL LOGGED FLT DECK TRIM VALVE. REPLACED CONTROL CABIN TRIM MOD VALVE V143 REF MM 21 61 21. ALL INSTALLATION TESTS NORMAL PER MM 21 61 21. ETOFeb 22, 2010 · N587AS · Boeing 737890SDR ASAA1057413Valve · failedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. ACCOMPLISHED FIM 21 62 00 810 832 FOUND CONTROL CABIN TRIM AIR VALVE BAD. REPLACED TRIM AIR VALVE PER AMM 21 61 21 00 801 21 61 21 400 801 LEAK & OPS CHECKS GOOD. RE-ACCOMPLISHED FIM 21 62 00 810 832, NO Feb 17, 2010 · N564AS · Boeing 737890SDR UALA2010021700604Shutoff Valve · failedTRIM AIR PRSOV RIGHT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE FAILED. RESET OK MSG-2124202 INACTV TA MODE. REPLACED RT TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE PER MM. TEST PASSED.Feb 17, 2010 · N791UA · Boeing 777222SDR ASAA1057411Accessory Unit · failedWHEN PRESSING RECALL ON MASTER CAUTION ZONE TEMP LIGHT FOR CONTROL CABIN COMES ON. PER QRH WHEN MASTER CAUTION IS RESET LIGHT GOES OUT. REPLACED M324 AIR CONDITIONING ACCESSORY UNIT TESTED ACAU NORMAL REF MM 21 51 02 400 801. RAN BOTH PACKS FOR 20 MIN PERFOFeb 15, 2010 · N586AS · Boeing 737890SDR ASAA1057385Controller · malfunctionedCONT CAB/ZONE TEMP LIGHT ILLUMINATED. NR 2 ZONE/TEMP CONTROLLER LOGGED FLIGHT DECK TRIM VALVE FAULT. RESET FAULT ON NR 2 ZONE/TEMP CONTROLLER. GROUND VERIFICATION TEST PASSED REF MM 21 61 00.Feb 15, 2010 · N558AS · Boeing 737890SDR UALA2010021500564Valve · stuckCHRONIC IMPOSSIBLE TO CONTROL CABIN TEMP IN AUTO OR MANUAL OR STANDBY MODES. ACFT VERY COLD. FOUND TRIM AIR PRESSURE REGULATING VALVE STUCK CLOSED. REPLACED VALVE AND ACCOMPLISHED CHECKS.Feb 14, 2010 · N648UA · Boeing 767322SDR UALA2010020900511Regulator · uncontrollableACFT TEMP IS STILL VERY HARD TO CONTROL IN AUTO SEEMS TO WORK OK WITH TRIM AIR OFF. NEED TO REPLACE TRIM AIR PRESSURE REGULATOR. NO PART IN SFO. REMOVED AND REPLACED TRIM VALVE AIR PRESSURE REGULATOR. LEAK CHECKED IAW MM.Feb 8, 2010 · N674UA · Boeing 767322SDR ASAA1057329Modulating Valve · faultedON RECALL AIR COND ZONE TEMP FOR CONT CAB REMAINS ILLUMINATED. ALL LIGHTS EXTINGUISH AFTER RESETTING THE MASTER CAUTION SYSTEM. RELEASED PER MEL 21-21F. AUTH BY SEAMC. NR 2 TEMP CONT FAULTED TCU FLT DK V143, WAS ABLE TO RESET VALVE REF MM 21-61-00-700-806-Feb 5, 2010 · N586AS · Boeing 737890SDR ASAA1057324Valve · failedAIR COND ZONE TEMP CONT CAB LIGHT ON RECALL GOES OUT ON RESET. REMOVED AND REPLACED CONTROL CABIN ZONE TRIM AIR MODULATING VALVE, BITE CHECK GOOD, OPS CHECK GOOD. NO RECALL LIGHT. REMOVED ACFT FROM MEL 21 21F C/N PLACARD 0204012, REMOVED CONTACTED SEAMC VERFeb 4, 2010 · N559AS · Boeing 737890SDR MYWA100034Warning Light · illuminatedETOPS SIGNIFICANT SYSTEM - FWD CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL.Feb 1, 2010 · N752MA · Boeing 73748ESDR ASAA1057314Valve · faultedAFT ZONE TEMP ANNUNC ILLUMINATED. EXTINGUISHES WHEN MASTER CAUTION IS RESET. CONFIRMED ZONE TRIM VALVE FAULT ON NR 1 PACK ZONE TEMP CTL REF MM 21-61-00. REPLACED NR 1 ACAU REF MM 21-51-02. OPS NORMAL REF SAME. RE-ACCOMPLISHED PACK/ZONE TEMP CTL BITE TEST Feb 1, 2010 · N581AS · Boeing 737890SDR ASOA201000143Warning Message · illuminatedIN FLIGHT GOT DISPLAY COOL CAUTION MESSAGE COMPLIED WITH QRH MESSAGE DID NOT EXTENGUISH, LANDED AS DIRECTED BY QRH. JUST PRIOR TO LANDING PFD1 MFD1 AND PFD 2 HAD DISPLAY TEMP MESSAGE ILLUMINATED ON THEM. ACFT RETURNED TO DEPARTURE AFTER T/O -- EMERGENCY DECLFeb 1, 2010 · N860AS · Cndair CL6002B19SDR ASAA1057311Control Valve · intermittentON RECALL RIGHT PACK MASTER CAUTION ILLUMINATES GOES OUT WHEN MASTER CAUTION RESET. FAULT CODE 216 224 00. ACCOMPLISHED BITE TEST ON PACK/ZONE TEMP CONTROLLERS REF FIM TASK 21 62 00 810 801. FOUND INTERMITTENT FAULT ON RIGHT TRIM CONTROL VALVE. RESET FAULTJan 31, 2010 · N559AS · Boeing 737890SDR ASAA1057290Valve · stuckAFT ZONE TEMP ILLUMINATED ON RECALL EXTINGUISHES ON MASTER CAUTION RESET. AFT ZONE MODULATING VALVE STUCK OPEN DUE TO ZONE TEMP CONTROL VALVE FAULTY. VALVE ASSY ZONE TEMP CONT IPC 21 62 01 03 ITEM 10. 3214972 1. REMOVED & REPLACED TRIM AIR PRESSURE REGULATIJan 28, 2010 · N581AS · Boeing 737890SDR ASAA1057286Unknown · malfunctionedZONE TEMP FOR CONT CAB ILLUMINATES ON RECALL. QRH CHECKLIST ACCOMPLISHED. LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. BITE SHOWS FLT DECK TRIM VALVE FAULT ON NR 2 CONTROLLER. FAULT RESETS & BITE OF NR 1 AND NR 2 CONTROLLER OPS NORMAL REF AMM 21Jan 26, 2010 · N557AS · Boeing 737890SDR FDEA201001220227Valve · failedON CLIMB OUT RECEIVED LVL 2 ALERT TRIM AIR OFF TEMP REACHED 225 F. COCKPIT TEMP 99 F COULD NOT CONTROL TEMP IN AUTO WITH QRH OR MANUAL. TEMP LOWERED TO 190F AND REMAINED THERE UNTIL DECENT. FOUND FD TRIM AIR VALVE STUCK OPEN. PN 398398-3 CURRENTLY NIS ANJan 22, 2010 · N585FE · Doug MD11FSDR HALA2010011800036Controller · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS MESSAGE FWD CABIN TEMP. TEST CABIN TEMP CONTROL IAW BFIM 21 61 00 FIG 404, SYSTEM OK.Jan 18, 2010 · N580HA · Boeing 76733ASDR HALA2010011300018Controller · malfunctionedETOPS SIGNIFICANT SYSTEM - FWD CABIN TEMP INOP LIGHT DISPLAYED ON EICAS AND OVERHEAD. RESET ZONE TRIM CONTROLLER AND OPS NORMAL.Jan 13, 2010 · N580HA · Boeing 76733ASDR UALA2010011100145Controller · inoperativeCOCKPIT TEMP SELECTOR INOP LIGHT ON IN AUTO. INSTALLED NEW ZONE TEMP CONTROLLER. INOP LIGHT EXTINGUISHED. OPS NORMAL.Jan 10, 2010 · N657UA · Boeing 767322SDR ASAA1057189Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON RECALL. EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE CHECK REF FIM 21 62 00 810 801. NR 2 CONTROLLER LOGGED THIS PACK TCV. REMOVED AND REPLACED RIGHT PACK TCV REF MM 21 51 10. VALVE LEJan 2, 2010 · N559AS · Boeing 737890SDR ASAA0957173Modulating Valve · failedCONT CABIN ZONE TEMP AMBER LIGHT ILLUMINATES ON RECALL. LIGHT EXTINGUISHES WITH MASTER CAUTION PRESSED. REMOVED AND REPLACED CONTROL CABIN TRIM MODULATING VALVE IN LT A/C BAY PER AMM 21-61-21-400-801. PERFORMED BITE CHECK AND LEAK CHECK PER AMM 21-61-21-400Dec 27, 2009 · N557AS · Boeing 737890
Back to JASC 2160