JASC 2161
Service difficulty reports · 308
Reports filed under 2161 · Cabin Temperature Controller, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2161' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2161' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM88960329Temp Controller · malfunctionedON TAKEOFF, A STRONG ACRID SMELL FILLED THE CABIN IMMEDIATELY FOR APPROX 4-5 MINUTES. BEFORE CLEARING ODOR, RETURNED WHEN GEAR EXTENDED FOR LANDING. TEMP IN COCKPIT INCREASED, SMOKE DET. ACTIVATED. FOUND RT AUTO TEMP CONT HAD VALVE FULL OPEN, RAN FULL COLD SDR 96ZZZX570Control Module · failedMSP - FLT 417 - UPON ARRIVAL, FLIGHT CREW REPORTED AN ACRID ODOR AND SMOKE IN THE CABIN. ODOR AND SMOKE CLEARED WHEN LEFT PACK WAS TURNED OFF. MAINTENANCE REPLACED THE CABIN TEMPERATURE MODULE AND SYSTEM CHECKED OKAY.SDR HEEA956259Sensor · stickingSENSOR STICKING AND DOES NOT REGULATE TEMPERATURE.SDR 9518339911Temp Control · malfunctionedYXE - DURING CLIMB, SMOKE ACCUMULATED IN THE CABIN, CREW FOLLOWED COCKPIT OPERATING MANUAL PROCEDURES. AIRCRAFT RETURNED TO YXE AND LANDED WITHOUT INCIDENT. REPLACED THE LEFT AIR CONDITIONING PACK CONTROLLER AND COALESCER BAG, OPERATIONAL CHECK GOOD.SDR 95UAL900160Temp Controller · failedLEFT PACK MIX VALVE STUCK IN FULL COLD - CAUSED PACK TRIP WITH SMOKE IN COCKPIT AND CABIN. THIS INCIDENT OCCURRED ON AUGUST 7, BUT WAS NOT REPORTED THROUGH THE NORMAL CHANNELS. REPLACED CABIN TEMPERATURE CONTROLLER. COMPONENT CHECKED OKAY IN SHOP.SDR SIMA952451Temp Controller · failedFLT NR 3935 - FSM - FLIGHT ATTENDANTS REPORTED SMOKE SMELL AND HIGH PITCHED WHINE, FLIGHT DIVERTED TO FSM, RECIRC FAN TURNED OFF. CREW DECLARED EMERGENCY FOR PRIORITY HANDLING. MAINTENANCE INSPECTED AND DETERMIND FAULT WITH LEFT AUTO TEMP CONTROL SYSTEM. SYSDR 95ZZZZ250Amplifier · malfunctionedSTL - FLT 518 - DURING CLIMB A SMOKE ODOR APPEARED IN CABIN. TURNED RIGHT AIR CONDITIONING PACK TO FULL COLD, ODOR AND HAZE DISSIPATED, RETURNED TEMPERATURE CONTROL TO NORMAL RANGE. REPLACED TEMPERATURE CONTROL AMPLIFIER, (P/N 607146-2-2) AND WATER SEPARATORSDR 95ZZZX2449Valve · failedTEMPERATURE CONTROL VALVE DIAPHRAGM RUPTURED CAUSING DAMAGE TO DIAPHRAGM BODY AND SEVERING ACTUATING LINKAGE. AIRCRAFT WAS PREPARING FOR DEPARTURE WITH NO CONTROL OF COCKPIT HEAT. HEAT WAS FULL HOT. VALVE WAS REPLACED AND A CONTROL PRESSURE CHECK WAS C/W.
Back to JASC 2161