SDR YENA20100724103Electrical Box · malfunctionedFLT 1263 BOS-AUS, INFLIGHT AT FL 340, THE F/A NR 1 REPORTED ELEC SMELL AT ROW 13. CREW DEPOWERED ALL 3 IFE/CSS SWITCHES AND SMELL ABATED AFTER FEW MINUTES. PERFORMED ELECTRIC ODOR SYSTEM INTEGRITY AND FOUND 11AB XEB WITH ODOR. REMOVED AND REPLACED 11AB XEB,SDR CA100726009Electrical Box · failedDURING FLIGHT, AN ACRID ODOR WAS DETECTED IN THE CABIN IN THE VICINITY OF ROWS 5-7DEF. THE LIVE-TV INFLIGHT ENTERTAINMENT SYS SEAT EQUIPMENT WAS SUSPECTED AS THE SOURCE OF THE ODOR AND WAS DEACTIVATED BY THE FLIGHT CREW. THE ODOR SOON DISSIPATED. FLIGHT WAS SDR AALA20100720MIA01Monitor · failedMIA - CREW REPORTED SMOKE AND ELECTRICAL ODOR IN CABIN. EMERGENCY DECLARED RETURNED MIA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND SMELL COMING FROM TV MONITOR IN THE MID GALLEY AREA. REPLACED TV MONITOR. SYSTEM GROUND CHECKED NORMAL OPSDR UALA2010063002333Monitor · sparksPAX REPORT SAW SPARKS IN OVERHEAD MONITOR AT ROW 27. MAINT REPLACE OR DEACTIVATE MONITOR BEFORE FLIGHT AND APPLY MEL 2520GY. PLACED DEFERRAL PER SAM-C FOR PRECAUTIONARY MEASURE FOR MONITOR REPLACEMENT. REF MEL 2520GY. REMOVED CONNECTOR FROM MONITOR AT ROW SDR UALA2010063002338Entertain Sys · inoperativeENTIRE PASSENGER ENTERTAINMENT SYSTEM IS INOPERATIVE.SDR UALA2010063002321Display · odorELECTRICAL ODOR IN CABIN. SEAT 1A VIDEO SCREEN POPPED & WENT BLANK. AN ELECTRICAL ODOR WAS NOTED AFTERWARDS BUT DISSIPATED AFTER VIDEO SYS & BUFFER BOXES SELECTED OFF. POSSIBLE VDB BOX FAILURE. SYSTEM REINSTATED. AFTER 10 MIN SLIGHT ELECT ODOR NOTED FROM SDR UALA2010062802309Multiplexer · faultyAMUX 2 HAS AN INTERNAL FAULT ON QUICK TEST ON CSCP. SYSTEM FOUND FAULTY. REPLACED AMUX 2 PER MM, OPS CHECKS GOOD.SDR F3LA2010063000445Entertain Sys · smokeREFERENCE LOG PAGE 529827 ITEM 1 AND LOG PAGE 529836 ITEM 1. SEAT 13A TV SMELLS HOT AND WAS SMOKING. INSPECTED ROW 13 ABC FOR SMOKE AND INSPECTED EPSU'S. NO DEFECTS NOTED. PERFORMED ELECTRICAL ODOR SYSTEM INTEGRITY CHECK IAW LIVE TV AMM 44-25-00 PAGE 5042 SDR AALA20100621CCS01Video Monitor · inoperativeCCS DURING FLIGHT FLIGHT ATTENDANTS NOTICED ELECTRICAL ODOR AROUND ROWS 12 TO 17 AND REALIZED MONITOR NUMBER 5 WAS INOPERATIVE AROUND THAT AREA. VIDEO MONITOR SYSTEM WAS POWERED OFF AND THE SMELL WENT AWAY. SYSTEM REMAINED OFF FOR DURATION OF FLIGHT. FLIGHT LSDR AALA20100620LHR02Audio Video Unit · failedLHR - FLIGHT ATTENDANT REPORTED SMELL OF BURNING WIRES NEAR SEAT 13G. SMELL DISSIPATED AFTER ELECTRIC POWER REMOVED FROM VIDEO SYSTEM AND RECIRCULATION FANS TURNED OFF. FLIGHT LANDED LHR WITHOUT INCIDENT. SEATS 12 E AND G AUDIO VIDEO UNIT FOUND WITH FAN FAISDR CA100712007Display · faultySTRONG ELECTRICAL ODOR, ROW 26/27 ACFT IN FLIGHT. CONFIRMED COMPLAINT. ISOLATED FAULT TO SEAT 28D SVDU INTERNALLY OVERHEATED/FAULT. REPLACED SEAT 28D SVDU WITH P2 DOWNLOAD AND OPS TESTED SERVICEABLE.SDR F3LA2010061600443Electrical Box · odorREF: PILOT WRITE UP LOG PAGE 530969, ITEM 1, 06/16/2010. HOT SMELL NOTED ROW 24D. TV SYS SHUT OFF, SMELL WENT AWAY. AIR TURN BACK. DEFER REF IAW MEL 44-20-01AA CONTROL NR 1075944. NO ODOR NOTICED ON GROUND. REF LOG PAGE 530975, ITEM 2, 06/17/2010. R & R SDR UALA2010052401747Transceiver · out of tolerancePORTABLE VHS TRANSCEIVER LOCATED IN COMPARTMENT ADJACENT TO 4 LT DOOR IS EXPIRED. INSTALLED NEW TRANSCEIVER IN AFT RT COMPARTMENT.SDR T17A420CT5/21Entertain Sys · odorDURING CLIMB OUT, CREW DETECTED ELECTRICAL SMOKE ODER AT SAME TIME PASSENGER REPORTED SMOKE COMING FROM LT PASSENGER ENTERTAINMENT DISPLAY UNIT. THE CAPTAIN IMMEDIATLY TURNED OFF GALLEY POWER. F/O WENT INTO CABIN AND PASSENGER HAD DISCONNECTED THE POWER CORD SDR UALA2010052001706Video Monitor · faultyCM2502 OVERAISLE VIDEO MONITOR AT SEAT 23G INOP. ORDERED PART PN 477W7162-33B (VIDEO MONITOR) NO STOCK. SFO OSTF NR M1030. VIDEO MONITOR NONE STOCK AT SFO. ORDERED ON OSTF M1030. ACTUAL MONITOR THAT IS INOP IS AT SEAT 22A, MONITOR AT SEAT 23G OPS CK OK. SDR DL757101273Entertain Sys · odorDURING FLIGHT, F/A DISCOVERED A BURNING ODOR AROUND ROW 32. IFE SYS WAS TURNED OFF. ODOR THEN DISSIPATED. MX CHECKED AND OPERATED ENTIRE IFE SYS AND ALL WAS NORMAL.SDR SIMA201013701Cd Player · malfunctionedON FLIGHT 4287 DURING CRUISE THE FLIGHT ATTENDANT REPORTED A BURNING ODOR FROM THE CD PLAYER. THE CREW PULLED CIRCUIT BREAKER J15AND THE ODOR WAS GONE. THE AIRCRAFT CONTINUED TO CMH AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED ASDR CNMA20100019Decoder · failedF/A'S BROUGHT TO ATTENTION OF COCKPIT THAT IF READING LIGHTS, CALL LIGHTS AND AUDIO INOP IN B ZONE MAY EFFECT O2 GENERATORS, MAINT CONTROL CONFIRMED RETURNED TO DEPARTURE. R&R SECTION TIMER DECODER IN ZONE "B", OTBD IAW AMM 23-33 CHK OPS NORMAL. ACCOMPLISHESDR YENA20100412058Electrical Box · malfunctionedFLT 828 SDQ-JFK SLIGHT BURNING / ELECTRICAL SMELL IN ACFT CABIN NEAR ROWS 22-24. DEPOWERED LTV SYSTEM AND SMELL DISSIPATED. PERFORMED TSM 23-39-00-810-801. NO DEFECTS NOTED. REPLACED XEB AT ROWS 24LT, 24RT AND 23LT DUE TO SUSPECTED BURNING ODOR PER MM 44-2SDR UALA2010040601149Video Display · faultySEAT 11D, E & F THE VIDEO & AUDIO INOP. CREW SMELLED SMOKE IN THAT AREA BEFORE TAKEOFF. MAINT CKD BUT DIDN'T FIND OR SMELL ANYTHING. FOUND VDB ITSELF SMELLED A LITTLE, REPLACED VDB AND VIDEO WORKS BACK TO NORMAL. SMELL DID NOT OCCUR WHILE ON GROUND.SDR YENA20100401048Electrical Box · failedFLT 631 BOS-SFO STRONG BURNING SMELL (ELECTRONIC) FROM MID CABIN. TURNED OFF LTV SMELL DISAPPEARED IMMEDIATELY. PERFORMED INSPECTION PER TASK 24-00-00-810-823. FOUND 9F DPCU TO SEB CABLE NOT SECURED. SECURED 9F DPCU CABLE IAW LTV MM 23-39-00. ALSO REMOVEDSDR F3LA2010031500366Entertain Sys · smokePILOT WRITE UP FOR LIVE TV SMOKE WARNING AT GATE. MX ACCOMPLISHED VISUAL INSP IAW LIVE TV AMM 44-25-00. NO DAMAGE OR DEFECTS NOTED AT THIS TIME. PERFORMED OPS TEST OF THE SMOKE DETECTOR CONTROL PANEL IAW LIVE TV AMM 44-25-00 PAGES 5040 AND 5041. SYS OPS TESTSDR UALA2010030500764Video Unit · smokeSMOKE IN THE CABIN AROUND ROW 10J, FOUND SMOKE COMING FROM VIDEO UNIT AT 10J. TURNED VIDEO SYSTEM OFF AND SMOKE DISSIPATED...PER SAMC DISCONNECTED WIRES UNDER SEAT 10J AND ALSO DEACTIVATED SW BY TURNING OFF SWITCH UNDER SEAT 10 J REF MEL 2520ACS. TURNED VIDESDR YENA20100226025Electrical Box · faultyFLT JB1758 SJU-FLL LIVE TV SEAT 21E ODOR IN AREA. FLL MX PERFORMED TSM 23-30-00-810-801 AND TSM 24-00-00-810-823 FOUND LIVE TV SEAT ELECTRONICS BOX (XEB) AT SEAT 21E HOT TO THE TOUCH. POSSIBLY OVERHEATING BUT WORKING AS A PRECAUTION LIVE TV DEACTIVATED AND DSDR UALA2010022600707Video Unit · faultyVEP NR 1 TAPE STUCK IN UNIT. REPLACED VEP, OPS CHK NORMAL.SDR UALA2010022200647Display · faultySMOKE OBSERVED FOR ONE MINUTE FROM VIDEO SCREEN AT 22H NO RECURRENCE. FOUND VIDEO DISPLAY INOP AT 22H. NEED TO REPLACE VIDEO DISPLAY ASSY. ROBBED DISPLAY FROM SEAT 25C, MOUNTED AT SEAT BACK OF 24C AND NO HELP. REPLACED 22H MONITOR, OPS CKS GOOD.SDR YENA20100219021Electrical Box · failedFLT JB820 SDQ-JFK CABIN CREW REPORTED ELECTRICAL BURNING SMELL IN THE AFT CABIN AROUND ROWS 24 AND 25. SECURED IFE RACK POWER AND THE SMELL DISSIPATED. MX PERFORMED INSPECTION FOR ELECTRICAL SMELL AS PER FIM 24-00-00-810-823 AND FIM 23-39-00-810-801. NO FAUSDR 2010F00043Antenna · wrong partCUSTOMER (LIVETV) REPORTED IN-FLIGHT ENTERTAINMENT RECEIVE ANTENNA PN 3070571-102, SN 369 CAUSED VHF NR 1 RECEPTION PROBLEM ON ACFT. ACFT WORK REQUEST STATES, "COMPLETE ENG RUN AND MONITORED VHF WHILE SELECTING SYS ON AND OFF. FOUND THAT LTV SYS CAUSED A 6-10SDR CA100217004Antenna · malfunctioned(CAN) DURING ENGINE RUNS, MX NOTED A SIGNIFICANT LOSS IN VHF NR 1 RECEPTION SENSITIVITY WHILE THE LIVE TV ENTERTAINMENT SYS WAS IN OPERATION, SPECIFICALLY IN THE UPPER TUNING RANGE. VHF NR 2 WAS UNEFFECTED. UPON REPLACEMENT OF THE LIVE TV SATELLITE ANTENNA, VHSDR DALA102723357Control Panel · smokeBURNING RUBBER ODOR IN CABIN, DEACTIVATED VIDEO CONTROL CTR IAW QRH SMOKE CABIN VIDEO SMOKE PROCEDURE, ODOR DISSIPATED AND LANDING WAS UNEVENTFUL. INSPECTED AND TESTED IFE AND NO BURNING ODOR DETECTED, ACFT CHECKS OK.SDR QXEA2010012900067Handset · malfunctionedCHIMES SOUNDS WHEN AFT F/A HANDSET IS PICKED UP ALONG WITH EMERGENCY LIGHT. REMOVED AND REPLACED AFT F/A HANDSET IAW AMM TASKS 23-31-11-000-802 AND 23-31-11-400-802. OPS TEST IS GOOD IAW AMM TASK 23-31-00-710-801. THIS ACTION CLEARS MEL 23-30-6(A). RETURNED SDR YENA20091230189Cooling Fan · seizedFLT 774 AUA-BOS DIVERTED TO BDA, SMOKE IND IN COCKPIT FOR AFT AVIONICS (LTV) RACK. PERFORMED GENERAL INSP PER TSM 23-39-00-810-801. FOUND LTV COOLING FAN SEIZED, FAN LIGHT ON AND C/B TRIPPED. REMOVED AND REPLACED COOLING FAN PER LTV MM 23-39-00. OPS CHECK SDR YENA20091221178Unknown · odorFLT JB712 SJU-JFK DURING FLIGHT BURNING ODOR COMING FROM LIVE TV POWER SUPPLY BOX FROM 18. MX PERFORMED INSPECTION OF IFES LIVE TV ELECTRICAL CIRCUITS & COMPONENTS AT ROW'S 17, 18 AND 19 LEFT/RIGHT PER AMM 23-39-00-810-801& ESPM 205200 NO CHAFING OR DEFECTS NSDR USAA2009122193399Deu · faultyFLT 388 - LAS-CLT - EMERGENCY EQUIPMENT - CIDS FAULT: FLIGHT ATTENDANT HANDSET AT L3 INOPERATIVE, SLIDE PRESSURE AND DOOR PRESSURE AT L3 AND R3 FAULTING, AND WON'T RESET. REMOVED AND REPLACED DEU B AT 300RH6 IAW AMM 23-73-47 OPERATIONAL CHECK WAS GOOD.SDR UALA2009121503886Monitor · faultyBURNING RUBBER ODOR NOTED IN AFT CABIN. FOUND COMING FROM 2ND TO LAST OVERHEAD MONITOR. DEACTIVATED OVERHEAD VIDEO SYS. REPLACED MONITOR AFT 2ND TO LAST AND CHECKED OKAY.SDR UALA2009121403860Entertain Sys · odorELECTRICAL SMOKE ODOR DETECTED BY CREW. LT CABIN SIDE ENTERTAINMENT SYS WENT INOPERATIVE. FOUND SEB BOX AT ROW 18 LT SIDE TO BE CAUSE OF ELECTRICAL ODOR. REPLACED SEB, POWERED UP ENTERTAINMENT SYS. NO FURTHER ODORS NOTED.SDR YENA20091118159Electrical Box · odorFLT JB72 MCO-JFK, DURING FLIGHT ELECTRICAL SMELL NOTICED FROM UNDER SEAT 10E. MX AT JFK COMPLIED WITH TSM 23-39-00-810-801 FOUND XEB AT SEAT 11 DEF WITH ELECTRICAL ODOR. REMOVED AND REPLACED SEAT 11 DEF XEB UNIT IAW LTV MM 44-20-17, LTV SYSTEM OPS CHECKS GOOSDR AALA20090915LAX01Power Supply · shortedCREW REPORTED SMOKING VIDEO MONITOR AT SEAT 17AB SHORTLY AFTER TAKEOFF. RETURNED TO LAX AND LANDED WITHOUT INCIDENT. FOUND A SHORTED POWER SUPPLY UNIT AT THE MONITOR. REPLACED POWER SUPPLY AND VIDEO MONITOR AT ROW 17AB. SYSTEM GROUND CHECKED NORMAL OPERATISDR CA090910009Connector · disconnectedHEATED PLASTIC ODOR CAME FROM UNDER SEAT 18AC. AFTER SCREENS 19AC AND 20AC WENT BLANK. 19A AND 20AC CAME BACK BUT NOT 19C. ODOR DISAPPEARED. CONNECTOR UNDER 18A RECONNECTED. 19C SVDU REPLACED. IP SEQUENCE AND SOFTWARE DOWNLOADED. AUDIO/VIDEO WORKS. NO BURNINGSDR YENA20090902103Electrical Box · failedFLT 1402 SFO-AUS HARSH ODOR REPORTED IN AFT CABIN WITH PACK 1 AND PACK 2 AND A HAZY SMOKE. WHILE T/S ODOR EVENT NOTED POSSIBLE SMELL FROM LTV XEB AT 23CD. OPS CHECK ON PACK 1 AND 2 OK IAW AMM 21-00-00. REMOVED AND REPLACED 23 XEB AND PERFORMED LTV MM 44-20-SDR YENA20090826101Entertain Sys · odorLIVE TV SYSTEM ALL, FLT CREW REPORTED ODOR COMING FROM ROW 9 AREA AND DISSAPATED WHEN LIVE TV SYSTEM WAS TURNED OFF. COMPLIED WITH TSM TASK 24-00-00-810-823. NO DEFECT NOTED. TSM TASK 23-39-00-810-801 NEEDS TO BE ACCOMPLISHED ON LIVE TV SYSTEM. LIVE TV SYSSDR YENA20090813095Entertain Sys · odorFLT 34 JFK ROC ON TAKE OFF CLIMBING TO 1500 FT FA NR 2 REPORTED A "BURNED PLASTIC ODOR" VERY STRONG IN THE BACK. A LITTLE IN FRONT OF CABIN AND NO SMELL IN COCKPIT NO SMOKE WAS REPORTED.GOING TO 14000 FT ODOR DISSIPATED ON DESCENT FA NR 2 SAID ODOR CAME BACK SDR YENA20090811094Entertain Sys · malfunctionedFLT 481 BOS-LGB LTV ALL INOP DUE TO BURNING SMELL. DURING FLIGHT STRONG ELECTRICAL ODOR COMING FROM ROW 18 AND 19 AREA. TURNED ENTIRE LIVE TV OFF AND SMELL SUBSIDED. PERFORMED INSPECTION OF LIVE TV SYSTEM PER TSM 23-39-00-810-801. RAN SYSTEM FOR ONE HOUR WSDR YENA20090810092Entertain Sys · malfunctionedFLT 844 - SJU-BOS - SMELL OF BURNED PLASTIC IN FLT ROWS 3-10, ROW 7 (SEAT 7E) IN PARTICULAR. SMELL DISSIPATED AFTER TURNING LTV OFF. PERFORMED THOROUGH INTEGRITY INSPECTION/ OPERATIONAL CHECK OF CABIN SEAT ROWS 1-12 RT, REMOVED SEB COVERS / SHROUD AND INSPECSDR YENA20090806088Entertain Sys · malfunctionedFLT 641 - JFK-SFO - DIRECT LTV WAS INTERMITTENT, THEN INOP. DID NOT RESPOND TO FULL RESETS, MOVIES WORKED. AFTER LANDING F/A'S CALLED TO REPORT AN ELEC/BURNING SMELL IN CABIN. AFT AVIONICS RACK POWER WAS SELECTED OFF AND SMELL DISSIPATED (LIVE TV SYSTEM-ALLSDR UALA2009071602106Control Panel · inoperativeCABIN SYSTEM CONTROL PANEL LOCK UP. CABIN SYSTEM CONTROL PANEL INOP, HAVE A CSCP IN DEN. TRIED SWAPPING AREA CONTROL PANEL TOUCH SCREEN WITH CSCP TOUCH SCREEN, NO HELP. NEEDS CSMU ON AOG F5256. MAINT NOTED, ALL OPS CHECK NORMAL.SDR YENA20090716074Entertain Sys · malfunctionedFLT 753 - JFK-CUN, SMOKE SMELL AT ROW 6 & 7. TURNED OFF LIVE TV, SMOKE WENT AWAY. PERFORMED TASK 23-39-00-810-801, PART B ON ROWS 4 THRU 9. NO FAULTS, OK FOR SERVICE.SDR YENA20090711072Electrical Box · failedFLT 1784, PLASTIC/ELECTRICAL ODOR IN THE VICINITY OF ROW 21, TURNED OFF TV/ASSC POWER BUT ODOR REMAINS. MET WITH BOTH CABIN CREW MEMBERS CONFIRMED PRESENCE OF ODOR AROUND ROW 19 RT AND ALL CONNECTORS ROW 19 RT TO 25 RT. FOUND DAMAGE PINS AT ROW 20 RT XEB. RSDR USAA2009062991623Decoder · faultedFLT 1625 - CLT-SEA - EMERGENCY EQUIPMENT - CIDS CAUTION LIGHT ILLUMINATED, FAULTING SLIDE PRESSURE MID RIGHT. SLIDE BOTTLE PRESSURE IS GOOD. TROUBLESHOOTING CONTINUES. REMOVED AND REPLACED MID DOOR DECODER ENCODER PER MAINTENANCE MANUAL 23-73-42. OPERATIONSDR NWAA092203309Video Monitor · odorACRID ODOR OF BURNING PLASTIC BEGAN SHORTLY AFTER TAKEOFF IN ROW 12, PULLED BREAKERS AND ODOR FADED, LANDING WAS UNEVENTFUL. BULKHEAD VIDEO MONITOR REPLACED AND CHECKS OK. REF LOG PAGE 0092917.
Back to JASC 2330