JASC 2432

Service difficulty reports · 2,249

Reports filed under 2432 · Battery/Charger System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2432'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2012081404509Battery · faultyBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ELEC REPLACED CONTACTOR AND NR 2 BATTERY PER MM, OPS CHECKED NORMALAug 13, 2012 · N414UA · Airbus A320232SDR UALA2012081604541Battery · faultyMAIN BATTERY CHARGER STS MSG. REPLACED MAIN BATTERY, ALL INDICATIONS NORMAL.Aug 13, 2012 · N550UA · Boeing 757222SDR N6WA2012081304Charger · malfunctionedAPU BATTERY CHARGER STATUS MESSAGE. SWAPPED MAIN BATTERY WITH APU CHARGER IAW AMM 24-32-05 & 24-32-07.Aug 13, 2012 · N152GJ · Cndair CL6002C10SDR UALA2012080804295Battery · failedAPPROX 30 MINUTES AFTER GROUND POWER HOOKED UP, SMOKE EXITING E/E EXHAUST. OPENED E/E DOOR AND SMOKE IN AREA. BATTERY BOX RED HOT. ALSO NOTE AIRCRAFT LOG 6. REPLACED MAIN BATTERY AND BATTERY CHARGER. BATTERY STILL IN PROCESS OF FULLY CHARGING. NEED TO VEAug 7, 2012 · N798UA · Boeing 777222SDR UALA2012080804301Charger · failed'BAT CHARGER APU' EICAS STATUS MSG DISPLAYED. APU BATTERY CHARGER FAILS. INPUT POWER TO APU BATTERY CHARGER GR IS OFF OR FAILS. APU BATTERY CHARGER INTERLOCK IS OPEN. APU BATTERY IN OVERHEATED CONDITION. REPLACED APU BATTERY AND CHARGER.Aug 7, 2012 · N127UA · Boeing 747422SDR UALA2012080604223Battery · failedAPU BATTERY FAILED. REPLACED BATTERY. APU BATTERY WEAK MESSAGE CLEARED. THEN APU BATTERY CHARGER INTERNAL FAULT MESSAGE BECAME ACTIVE. REPLACED BATTERY CHARGER MESSAGE CLEARED. OPS CHECKS GOOD. APU BATTERY MSG REOCCURED.Aug 3, 2012 · N781UA · Boeing 777222SDR UALA2012080604209Battery · weakMAIN BATTERY WEAK STATUS MESSAGE DISPLAYED. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM.Aug 2, 2012 · N772UA · Boeing 777222SDR ASAA2012081092692Battery · inoperativeAPU WILL NOT START. ACFT GROUNDED. R & R STARTER GENERATOR IAW AMM 49-41-21-000-801 & 49-41-21-400-801. STARTER OPS CHECKED GOOD ON GROUND POWER. AFTER SWITCHING OFF APU GENERATORS, APU AUTO SHUTDOWN. PERFORMED APU BITE PROCEDURE 49-60-00-810-801. FOUND FAug 1, 2012 · N557AS · Boeing 737890SDR TRBA20120730002Battery · inoperativeDURING MAINTENANCE INSPECTION, FOUND THE MAIN BATTERY HAS NO POWER. THE ACFT WAS REMOVED FROM SERVICE. R & R THE BATTERY AND THE EMERGENCY BATTERY IAW WC EX-243185-RAI-10010-006. THE ACFT WAS RETURNED TO SERVICE.Jul 30, 2012 · N414WF · Aerosp ATR72212SDR TRBA20120730001Battery · unserviceableDURING MX INSPECTION FOUND THE EMERGENCY BATTERY WITH LOW VOLTAGE. ACFT REMOVED FROM SERVICE. R & R EMERGENCY BATTERY IAW WORK CARD EX-243185-RAI-10020-002. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.Jul 30, 2012 · N447AM · Aerosp ATR72SDR UALA2012073004117Battery · faultySTATUS MESSAGE MAIN BATTERY CHARGER DISPLAYED IN FLT. REPLACED "MAIN BATTERY" PER AMM.Jul 28, 2012 · N553UA · Boeing 757222SDR UALA2012072704069Charger · failedSTANDBY TEST FAILED. MAIN BATTERY DOES NOT RECHARGE. MAIN BATTERY CHARGER WAS REPLACED.Jul 26, 2012 · N121UA · Boeing 747422SDR FDEA201207262721Relay · inoperativeAPPROX 6.5 HRS INTO FLIGHT BATTERY DISCHARGING ALERT ILLUMINATED IAW QRH, DIVERTION INITIATED, AFTER 5-7 MINUTES THE ALERT WENT OUT. ELECTED TO PROCEED TO DESTINATION. VOLTAGE WAS CONSTANT 33 VOLTS DURING AND AFTER THE ALERT. ILLUMINATED AGAIN ON SHORT FJul 26, 2012 · N529FE · Doug MD11FSDR CA120727013Battery · overheated(CAN) DEFECT-1066780 AUXILIARY BATTERY HOT CAUTION LIGHT WITH SMOKE REPORTED COMING FROM BATTERY. POWER SHUTOFF AND FIRE CRASH HAS DISCONNECTED BATTERY. AUXILIARY BATTERY REPLACED. TESTED SERVICEABLE IAW AMM 24. REMOVED BATTERY ROUTED TO O/H SHOP FOR INSPJul 25, 2012 · Dhav DHC8311SDR FDEA201207252669Charger · malfunctionedEMERGENCY POWER TEST FAIL NOTED ON POST FLIGHT INSP. EPCU SHOWS BATTERY/INTFC UNDER CURRENT FAULTS AND LAST TWO FLIGHT LEGS. COMPLIED WITH FIM 24-30-03-00 BATTERY VOLTAGE FOUND TO BE WITHIN LIMITS. EMERGENCY POWER TEST ATTEMPTED THREE TIMES, TWO FAILED, PJul 25, 2012 · N608FE · Doug MD11FSDR UALA2012072704078Battery · faultyDUE TO REPEAT HITS ON BCL2 WITH BCL2 AND FUSE 4PB2 BEING REPLACED. REPLACED BATTERY 2. TESTED OK ON CFDS.Jul 24, 2012 · N848UA · Airbus A319131SDR UALA2012072704075Battery · faultyEICAS MESSAGE, MAIN BATTERY CHARGER DISPLAYED AND BATTERY DISCHARGE LIGHT EXTINGUISHED. REPLACED MAIN AIRCRAFT BATTERY, OPS CHECKED GOOD.Jul 24, 2012 · N521UA · Boeing 757222SDR UALA2012072303960Battery · faultyCREW REPORTED A MAIN BATTERY AND CHARGER MESSAGE. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM, OPS CHECKED NORMAL, MESSAGES CLEARED.Jul 23, 2012 · N769UA · Boeing 777222SDR CA120719007Battery · thermal runaway(CAN) DURING CRUISE, FLIGHT CREW RECEIVED A MAIN BATTERY HOT RED WARNING LIGHT AND CONFIRMED THE BATTERY OVERHEAT CONDITION ON THE BATTERY TEMPERATURE DISPLAY SCALE. AN EMERGENCY WAS DECLARED AND DECISION WAS TAKEN TO RETURN AND LAND. THE ACFT LANDED WITHOUT Jul 18, 2012 · Dhav DHC8102SDR SIMA20120708010Battery · malfunctionedFLIGHT 3559, CREW REPORTED, AFTER TAKEOFF AT AROUND 3000 FT HAD A MASTER WARNING BATTERY 2 OVERTEMP MESSAGE DISPLAYED ON EICAS. FOLLOWED AOM PROCEDURES AND DECLARED AN EMERGECNY AND RETURNED DEPARTURE. AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMJul 8, 2012 · N657AE · Emb EMB145LRSDR SIMA20120708002Battery · malfunctionedON FLIGHT 3559 THE CREW REPORTED THAT DURING CLIMB AFTER TAKEOFF THE NR 2 BATTERY OVERTEMP WARNING CAME ON "71" C. THE CREW DECLARED AN EMERGENCY AND RETURNED TO MIA. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND Jul 8, 2012 · N662EH · Emb EMB145LRSDR ASAA2012071692557Battery · failedAPU WILL NOT START. INTEREGATED CDU FAULT CODE 49-41248. STARTER CONVERTER UNIT SHOWS SYS INOPERATIVE. DURING BATTERY START WITH NO EXTERNAL POWER APPLIED, BATTERY STARTING VOLTAGE 25 VDC THEN DROPS TO A MINIMUM OF 19VDC WITH A MAX CURRENT DRAW OF -210 AMPSJul 1, 2012 · N596AS · Boeing 737890SDR UALA2012070203518Battery · dischargedMAIN BATTERY CHARGES STATUS MESSAGE. REMOVED AND REPLACED MAIN BATTERY AND REMOVED AND REPLACED MAIN BATTERY CHARGER.Jun 29, 2012 · N553UA · Boeing 757222SDR TRBA20120623001Battery · dischargedDURING MX INSPECTION, FOUND THE EMERGENCY BATTERY HAS LOW VOLTAGE. THE ACFT WAS REMOVED FROM SERVICE. R & R EMERGENCY BATTERY IAW WC EX-243185-RAI-10020-001. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.Jun 23, 2012 · N429AT · Aerosp ATR72SDR MASA2012062134916Battery Pack · inoperativeNR 2 BATTERY PACK INOPERATIVE. REMOVED AND REPLACED NR 2 BATTERY EMERGENCY PACK.Jun 19, 2012 · N511MJ · Cndair CL6002C10SDR YYFA20120612001Battery · failedDURING WALK AROUND, FOUND SMOKE COMING OUT OF BATTERY VENT PORTS. MX R & R BOTH SHIPS BATTERIES, BATTERY CHARGER AND THERMAL SENSORS IAW AMM 24-30-01,02,00.Jun 12, 2012 · N836NK · Doug DC983SDR ASAA2012062192397Charger · inoperativeAFTER ENGINE START, ELECRICAL LIGHT ILLUMINATED. ACFT GROUNDED. AUX BATTERY CHARGER INOPERATIVE, FAULT ON PANEL. AUX BATTERY CHARGER BATTERY LED INDICATION IS DARK. REMOVED AUX BATTERY CHARGER REF 24-31-31-000-801, INSTALLED AUX BATTERY CHARGER. BATTERY LEDJun 2, 2012 · N559AS · Boeing 737890SDR ASAA2012062092387Charger · inoperativeLIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. PERFORMED FIM TASK 24-31-00-810-801. AUX BATTERY CHARGER INOPERATIVE, FAULT CODE SHOWED ON DISPLAY. PERFORMED FIM TASK 24-31-00-810-825. AUX BATTERY CHARGER RESET AND OPS CHECKED NORMAL IAW FIM TASK 24-31-Jun 2, 2012 · N559AS · Boeing 737890SDR TRBA20120601001Battery · dischargedDURING B INSPECTION, FOUND THE EMERGENCY BATTERY LOW VOLTAGE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY BATTERY IAW W/C EX-243185-RAI-10020-001. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.Jun 1, 2012 · N355AT · Aerosp ATR72212SDR UALA2012052702995Battery · faultyMAIN BATTERY CHARGER STATUS MESSAGE AT DEPARTURE. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER AMM, OPS CHECK OK.May 25, 2012 · N550UA · Boeing 757222SDR TRBA20120524001Battery · faultyCREW REPORTED, DURING TAXI RECEIVED A MAIN BATTERY CHARGE INDICATION FAULT MESSAGE. ACFT REMOVED FROM SERVICE. R & R MAIN BATTERY. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.May 24, 2012 · N408AT · Aerosp ATR72212SDR TIMA20120501007Battery · leakingDURING ENGINE START ALL ELECTRICAL POWER FAILED. CAUSE WAS FOUND TO BE ACID LEAK THROUGH AT THE NEGATIVE POST OF THE AIRCRAFT LEAD ACID BATTERY WHICH CAUSED CORROSION OF THE CONNECTOR.May 1, 2012 · N326CA · Beech 99ASDR CA120502008Battery · weak(CAN) COULD NOT START THE ACFT BECAUSE THE BATTERY WAS WEAK. REMOVED THE BATTERY TO FIND IT LEAKING. REPLACED THE BATTERY WITH A NEW RG355. THIS BATTERY WAS INSTALLED NEW IN SEPTEMBER 2011.Apr 30, 2012 · Snias AS350B2SDR AALA20120428009Charger · defectiveMCO INFLIGHT STL-MIA. CREW REPORTED MAIN BATTERY CHARGER EICAS STATUS MESSAGE. COULD NOT VERIFY REASON OR ISSUES OF BATTERY STATUS. EMERGENCY DECLARED FLIGHT DIVERTED MCO LANDED WITHOUT INCIDENT. REPLACED MAIN BATTERY CHARGER THAT WAS BAD. SYSTEM GROUND Apr 28, 2012 · N182AN · Boeing 757223SDR ASAA12511458Battery · failedMAIN BATTERY SHOWS 27 VOLTS AND A CONSTANT CHARGE OF 3 AMPS. AUX BATTERY SHOWS 27 VOLTS AND A CONSTANT 2 AMP CHARGE. ACFT GROUNDED. R & R AND TESTED AUX AND MAIN BATTERY IAW MM 24-31-11. TEST PASSES OK FOR SERVICE.Apr 25, 2012 · N592AS · Boeing 737890SDR UALA2012042402452Battery · inoperativeTEST FLT, NR 2 ENGINE FIRE LOOP A FAULT IN FLT. REMOVED AND REPLACED ENGINE AND APU FIRE PANEL FOR TROUBLESHOOTING. NO CHANGE, INSTALLED ORIGINAL PANEL IAW AMM. NR 2 MAIN BATTERY WAS FOUND INOPERATIVE AND IS THE SOURCE OF THE POWER FOR THE NR 2 ENGINE LOOPApr 24, 2012 · N418UA · Airbus A320232SDR ASAA12511428Battery · failedACFT AUX BATTERY SHOWED +2 AMPS FOR ENTIRE 5 HR FLIGHT. VOLTS WERE NORMAL AT 27. NO OTHER ABNORMAL ELECTRICAL INDICATIONS NOTED. REPLACED NR 1 AND NR 2 BATTERY MAIN IAW AMM 24 31 11. OPS CHECKED GOOD. GROUND FUNCTIONAL CHECKED GOOD IAW AMM 24-31-11 NR 2 BATTApr 18, 2012 · N533AS · Boeing 737890SDR DALA1222649214Battery · overheatedFLIGHT CREW REPORTED STRONG ELECTRICAL ODOR IN FORWARD CABIN. MAINTENANCE FOUND HOT, SHIPS BATTERIES. REMOVED AND REPLACED SHIPS BATTERIES. OPERATION CHECKED GOOD PER AMM.Apr 12, 2012 · N914DN · Doug MD9030SDR ASAA12511371Battery · warning lightBATTERY DISCHARGE LIGHT ON 10 AMPS ON MAIN BATTERY METER. COMPLETED MAIN BATTERY CHARGER OP TEST PER AMM 24-31-21-PB501. MAIN BATTERY & CHARGER OP CHECKED GOOD, BATTERY DISCHARGE LIGHT EXTINGUISHED. AIRCRAFT WAS ON JETWAY POWER AT THE TIME OPS GOOD ON APU PApr 8, 2012 · N514AS · Boeing 737890SDR UALA2012040402086Battery · faultySTATUS MESSAGE FOR APU BATTERY CHARGER. APU BATTERY REPLACED.Apr 4, 2012 · N773UA · Boeing 777222SDR ASAA12511350Battery · failedAIRCRAFT AUX BATTERY INDICATED +2 AMP CHARGE CONTINOUSLY FOR 2.5 HOURS. VOLTS WERE STEADY AT 27. MAIN BATTERY INDICATED 27 VOLTS 0 AMPS FOR ENTIRE TIME. NO OTHER ELECTRICAL SYSTEM ABNORMALITIES NOTED. REMOVED AND INSTALLED MAIN AND AUX BATTERY REF 24-31-11Apr 4, 2012 · N557AS · Boeing 737890SDR UALA2012040202045Battery · dischargedON ARRIVAL RECEIVED FLIGHT CONTROL SYS ON MAT MESSAGE 24-50241, LEFT FC BATTERY IS LOW, PER FIM 24-35 TASK 802. REPLACED BATTERY, MESSAGE EXTINGUISHED, PER MM OPERATIONAL TEST, NO FAULTS FOUND.Mar 31, 2012 · N226UA · Boeing 777222SDR TRBA20120320002Battery · unserviceableON FLIGHT 4811, CREW REPORTED THAT AFTER ENGINE START THE EMERGENCY BATTERY FAULTED. AIRCRAFT WAS REMOVED FROM SERVICE. R & R EMERGENCY BATTERY IAW W/C EX243185-RAI-10020-002. THE OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.Mar 20, 2012 · N342AT · Aerosp ATR72212SDR UALA2012030201296Battery · faultyMAIN BATTERY FAILS TEST JOB CARD 5-5010-A STEP 22U. AMPS DO NOT DROP TO ZERO WITHIN ONE TO TWO SECONDS. REPLACED MAIN BATTERY.Mar 2, 2012 · N543UA · Boeing 757222SDR ASAA12511174Unknown · malfunctionedMAIN BATTERY SHOWS A 3 AMP CHARGE ENTIRE FLIGHT. REF AMM 24 31 11 400 802 002 BATTERY AMPS SHOULD BE BELOW 5 AMPS POST BATTERY CHANGE. PRECAUTIONARY REPLACED MAIN AND AUX BATTERY PER AMM REF 24 31 11 000 802 002/ 24 31 11 400 802 002.Mar 2, 2012 · N579AS · Boeing 737890SDR UALA2012030201316Charger · faultyMAIN BATTERY DISCH EICAS. REPLACED MAIN BATTERY CHARGER, OPS CHECK OKAY.Mar 1, 2012 · N218UA · Boeing 777222SDR UALA2012030101288Battery · faultyMAIN BATTERY CHARGER STATUS MSG. REPLACED MAIN BATTERY AND BATTERY CHARGER PER MM, OPS CKS GOOD. CLEARED MESSAGE. BATTERY READING 29 VOLTS.Feb 29, 2012 · N646UA · Boeing 767322SDR UALA2012030101281Relay · faultyELEC STANDBY SYS ELECTRICAL DC-STANDBY POWER SYSTEM FAILED THE SYSTEM SELF-CHECK. STATUS MSG-2413035 ACTIVE AP MODE. REPLACED MAIN BATTERY RELAY REF MM, MAT TESTED BATTERY RELAY OPERATIONAL.Feb 28, 2012 · N212UA · Boeing 777222SDR ASAA12511164Battery · dischargedA/C MAIN BATTERIES LOW. REMOVED AND REPLACED BOTH BATTERIES PER MM 24 31 11. OPS CKS NORMAL.Feb 28, 2012 · N588AS · Boeing 737890SDR TRBA2012059002Battery · inoperativeFOUND EMERGENCY BATTERY INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R EMERGENCY BATT IAW/JIC 24-31-85 RAI 10020 OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.Feb 26, 2012 · N426AT · Aerosp ATR72
Back to JASC 2432