JASC 2432
Service difficulty reports · 2,249
Reports filed under 2432 · Battery/Charger System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2432' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2432' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2018121197309Battery · dischargedBATT VOLTAGE LOW. GROUNDED - YES. REMOVED AND REPLACED MAIN AND AUXILIARY BATTERY REF B737-800 AMM 24-31-11/401. 4 C/B'S OPENED, TAGGED, AND RESET. OPERATIONAL CHECK SATISFACTORY. ETOPS GROUND VERIFICATION SUCCESSFUL.SDR ASAA2018120227179Not Reported · malfunctionedAUX BATTERY DID NOT SHOW NEGATIVE VALUE WITH BATTERY SWITCH ON AND GRD PWR SWITCH OFF. GROUNDED - YES. PERFORMED FIM 24-31 TASK 801 NO FAULTS. REMOVED AND REPLACED MAIN AND AUX BATTERY NO HELP. REINSTALLED ORIGINAL MAIN AND AUX BATTERY. PERFORMED OPS CHECK OPSSDR UIEA2018120302765Unknown · malfunctionedON BATTERY PWR STBY PWR DID NOT WORK. PERFORMED STANDBY OPERATIONAL TEST IAW AMM 24-33-00 TEST OK AT THIS TIME.SDR SWAA2018112827195Battery · faultyAIR TURNBACK, DURING CLIMBOUT THERE WAS A STRONG SMELL OF BURNING ELECTRICAL, FLIGHT ATTENDANT REPORTED THE SAME SMELL IN THE AFT GALLEY. R&R BATTERY PER MM.SDR SWAA2018112827167Charger · faultyAIR TURNBACK, DURING CLIMBOUT THERE WAS A STRONG SMELL OF BURNING ELECTRICAL, FLIGHT ATTENDANT REPORTED THE SAME SMELL IN THE AFT GALLEY. R&R BATTERY CHARGER PER MM.SDR ASAA2018110826750Battery · dischargedFOUND BATTERY SWITCH LEFT ON - BATTERIES ARE DISCHARGED. GROUNDED - YES. RMVD/INSTALLED FWD AND AFT MAIN BATTERIES REF B737-900 AMM 24-31-11. SYS CKS NML.SDR CALA2018110502301Charger · inoperativeBATTERY DISHAGE LIGHT CAME ON. RETURNED SHOWED 4 TO 8 DISCHG UN TIL LANDING REMOVED AND REPLACED MAIN BATTERY REF AMM 24-31-11-400-801-001.O PS CK GOOD. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1296306 SN OFF 6302 BATTERY, AIRCRA OFF 29-2431-9-9001 6302 ONSDR 2018FA0000527Battery · leakingBATTERY LEAKS FROM AROUND TOP SEALING JOINT BEHIND POSITIVE POST. THIS IS THE THIRD HELICOPTER WITH CORROSION DAMAGE THAT WE HAVE FOUND CAUSED FROM A BATTERY OF THIS PN. RECOMMEND BOTH BATTERY AND HELICOPTER MFG GET TOGETHER AND CORRECT THE PROBLEM. THERE HSDR QMLA2018102618115Battery Box · smokeUPON APPROACHING HOSPITAL, THE PILOT NOTICED A BATTERY DISCONNECT LIGHT ON THE CAD, AND AT ABOUT THE SAME TIME DETECTED AN ELECTRICAL TYPE ODOR IN THE AIRCRAFT. HE THEN TURNED OFF THE BATTERY AND WAS LESS THAN TWO MINUTES FROM THE HOSPITAL, AND CHOSE TO LAND ISDR 2018FA0000439Solenoid · failedBATTERY SOLENOID FAILED DURING LANDING EXTENSION.SDR UIEA2018102502344Battery · not reportedMAIN AIRCRAFT BATTERY NEEDS REPLACEMENT. R&R AIRCRAFT MAIN BATTERY IAW 24-31-01. OPS CHECK NORMAL.SDR 2018FA0000438Solenoid · openBATTERY SOLENOID OPENED DURING LANDING GEAR EXTENSION.SDR AALA2018102414004Light · malfunctionedINTERMITTENT BATTERY DISCHARGE LIGHT ILLUMINATED, DC AMPS SWING FROM -25 TO 204. THE AIRCRAFT WAS GROUNDED. PERFORMED FIM 24-30-00-810-834, AND MAIN BATTERY CHARGER OPS CHECKED IAW MM 24-31-21-710-801. NO FAULTS. OK FOR SERVICE.SDR ASAA2018100826398Charger · failed"BAT DISCHARGE" LIGHT ILLUMINATED. GROUNDED - YES. REPLACED MAIN BATTERY CHARGER REF AMM 24-31-21/401 OPERATIONAL TEST OK REF AMM 24-31-21-710-801.SDR ASAA2018100326350Charger · inoperativeELEC LIGHT ILLUMINATED ON P5-13 PANEL. GROUNDED - YES. FOUND BATTERY CHARGER INOP MSG. REPLACED BATTERY CHARGER PER AMM 24-31-21. NO FAULTS NOTED.SDR ASAA2018092426211Warning System · false activation"ELEC" LIGHT ILLUMINATED. GROUNDED - YES. ACCOMPLISHED ELEC LIGHT BITE TEST FOUND BATT CHARGER 1 INOP. RESET P92 E1 CB ELEC FLIGHT FAULT CLEARED OPS CHECK NORMAL REF FIM 24-31-TASK 801 & 24-31-TASK 825.SDR UIEA2018091902005Warning System · false activationAPU BATT CHARGE STATUS MESSAGE. MX PROCEDURE C/W. PERFORMED SYSTEM OPERATIONAL TEST OK IAW AMM 49-11-00.SDR UIEA2018091701987Battery · dischargedMAIN SHIPS BATTERY IS DEAD. REMOVED AND REPLACED BATTERY IAW AMM 24-31-01 OPS CHECK GOOD.SDR ASAA2018091726141Charger · failedBATTERY DISCHARGE LIGHT ILLUMINATED DURING CLIMB THROUGH APPROX FL 220. MAIN BATTERY SHOWED -5 AMPS DISCHARGE RATE. AUX BATTERY SHOWED POSITIVE CHARGE RATE. LIGHT EXTINGUISHED AFTER APPROX 8 MINUTES OR SO BUT MAIN BATTERY CONTINUED TO SHOW -2 AMPS. MAIN BATTERSDR UIEA2018091401975Charger · inoperativeAPU COLD START UNSUCCESSFUL -50 SAT FL 390 1ST ATTEMPT UNSUCCESSFUL, -42 SAT FL 350 AND & ERD ATTEMPTS UNSUCCESSFUL. REMOVED AND REPLACED APU BATTERY PER AMM 24-31-04, OPS CHECK OK. P/N 018550-000, S/N 063627. REMOVED AND REPLACED APU BATTERY CHARGER PER AMM 2SDR SWAA2018090524855Battery · failedIN DESCENT CAPTAIN AND FIRST OFFICER SMELLED POSSIBLE ELECTRICAL FUMES COMPLIED WITH QRC AND QRH. FOUND P5 PANEL WITH BATTERY FAIL INDICATION. R&R BATTERY IAW AMM.SDR ASAA2018090425985Warning System · false activationAFTER START ON RECALL BOTH BAT DISCHARGE AND ELEC LIGHT WERE ILLUMINATED. BEFORE FIRST CHECKLIST WAS COMPLETED BAT DISCHARGE LIGHT WENT OUT, BUT ELEC LIGHT STAYED ILLUMINATED. GROUNDED - YES. ACCOMPLISHED FIM 24-31-801 BATTERY CHARGER INOP FAULT CLEARED FAULT SDR ASAA2018090425974Charger · inoperativeSECOND OCCURRENCE, AFTER START ON RECALL BOTH BAT DISCHARGE AND ELEC LIGHT WERE ILLUMINATED. BEFORE FIRST CHECKLIST WAS COMPLETED BAT DISCHARGE LIGHT WENT OUT, BUT ELEC LIGHT STAYED ILLUMINATED. GROUNDED - YES. REMOVED AND REPLACED MAIN BATTERY CHARGER OPS CHESDR UIEA2018082601799Unknown · malfunctionedAIRCRAFT MAIN BATTERY SHOWS 3 VOLTS. SWAPPED MAIN BATTERY WITH APU FOR TROUBLESHOOTING MAIN AIRCRAFT BATTERY SHOWS CHARGED NO OTHER DEFECTS IAW AMM 24-31-01.SDR 2018FA0000346Battery · leakingMECHANIC FOUND SIGNS OF LEAKAGE AND CORROSION BEHIND LOWER AFT PASSENGER SEAT BULKHEAD, SEAT FRAME AREA, BATTERY SHELF, BAGGAGE COMPARTMENT FLOOR. THE AIRCRAFT BATTERY IS MOUNTED ON ITS SIDE CAUSING THE ACID TO LEAK FROM SEALED BATTERY SERVICE PORTS.SDR UIEA2018080901642Charger · faultyAPU BATTERY CHARGER EICAS MSG DISPLAYED. REMOVED AND REPLACED APU BATTERY CHARGER IAW AMM 24-31-05 NO FIX. REMAINS OPEN. PERFORMED TROUBLE SHOOTING FIM 24-31 FT 805. R&R BATERY CHARGER PN OFF 4-254-05 S/N OFF 0324. T/S REF FIM 24-31 FT 806, FOUND C/B P6A1 (BATSDR ASAA2018081092725Battery · dischargedBOTH MAIN BATTERIES WERE DEAD. ACFT GROUNDED. REPLACED THE MAIN & AUX BATTERIES IAW AMM 24-31-11. INSTALLATION TEST CHECKED NORMAL.SDR DALA2018081074984Battery · failedA BATTERY CHARGER MESSAGE ILLUMINATED, A LOUD BANG, THEN AN ELECTRICAL ODOR IN THE COCKPIT. DECLARED AN EMERGENCY. REPLACED MAIN BATTERY AND CHARGER, OP CHECKED GOOD.SDR DALA2018080304835Charger · odorDURING WALKAROUND NOTICED ELECTRICAL FUME/SMELL FROM E&E COMPARTMENT AND FWD GALLEY. FOUND BATTERY CHARGER RELAY A2 TERMINAL BURNT. REMOVED A/C BATTERIES PER AMM24-30. REMOVED BATTERY CHARGER RELAY PER AMM 24-00 GENERAL. REPLACED R2-56, R2-63 AND BATTERY CHARGSDR HNAA2018080200178Battery · overtempBATT 1 OV/TEMP MSG INFLT 258 DEG 79 DEG ON GATE. REMOVED AND REPLACED NR 1 BATTERY IAW AMM 24-36-01. OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2018080200177Battery · overtempBATT 1 OV/TEMP MSG INFLT 258 DEG 79 DEG ON GATE. REMOVED AND REPLACED NR 1 BATTERY IAW AMM 24-36-01. OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2018072300164Battery · thermal runawayBATTERY 1 OVER TEMP CONTINUED THERMAL RUNAWAY. BATTERY REACHED 82 DEGREES C BEFORE ARFF DISCONNECTED IT. NO FIRE OR IGNITION NOTED. R&R BATTERY ONE AND TWO IAW AMM24-36-01. OPS CK GOOD OK FOR SERVICE.SDR UIEA2018071101435Not Reported · out of positionSTANDBY PWR DISCHARGE DOES NOT ILLUMINATE IN BATT POS AND NO CURRENT DRAW BEING INDICATED. RE-POSITIONED W146-013-2A TO POSITION 16 AND W146-012-24 TO POSITION 13. OPS CHECK GOOD IAW AMM 24-33-00.SDR CA180706014Contactor · corroded(CAN) AIRCRAFT REPORTED TO HAVE INTERMITTENT ELECTRICAL ISSUES. TURNING MASTER SWITCH ON WOULD NOT ALWAYS POWER UP A/C. SOMETIMES A/C WOULD POWER UP AND AS SOON AS STARTER WAS ACTIVATED EVERYTHING WOULD POWER DOWN. SOMETIMES A/C WOULD NOT POWER UP AND AFTERSDR ASAA2018070225242Unknown · malfunctionedAUX BATTERY CHARGER INOP. GROUNDED - YES. ACCOMPLISHED AUX BATTERY CHARGER OPS TEST, OPS NML. REF AMM TASK 24-31-31-710-801.SDR UIEA2018062801281Guard · missingBATTERY SWITCH ON THE OVERHEAD PANEL, GUARD MISSING. REMOVED AND REPLACED BATTERY SWITCH GUARD IAW AMM 20-84-14.SDR ASAA2018061025029Charger · failed"ELEC" LIGHT ILLUMINATED ON O/H PANEL. GROUNDED - YES. SYS LOGGED "AUX BATT CHGR INOP" MESSAGE, FAULT CLEARED BUT AUX BATTERY CHARGER GREEN "CHARGER" LIGHT IS ONLY DIMLY LIT. AUX BATT IS VERY WARM TO THE TOUCH. REMOVED AND INSTALLED BOTH MAIN AND AUX BATTERIESSDR ASAA2018060924994Charger · failedELEC LIGHT ILLUMINATED ON THE OVERHEAD PANEL. ACFT GROUNDED. VERIFIED FAULT, FOUND AUX BATTERY CHARGER INOPERATIVE IAW FIM 24-31 TASK 801. REPLACED THE AUX BATTERY CHARGER. ACCOMPLISHED AN AUX BATTERY CHARGER TEST, TEST PASSED IAW AMM 24-31-31-710-801, SDR UIEA2018060801081Charger · malfunctionedEICAS MESSAGE MAIN BATT CHGR. REMOVED AND REPLACED BATTERY CHARGER IAW AMM 24-31-02-404-007 OPS CHK NML.SDR UIEA2018060501040Charger · no testMAIN BATTERY CHARGER FAILED TWICE AFTER TEST. REMOVED AND REPLACED THE MAIN BATTERY CHARGER IAW AMM 24-31-02. OPS CHECKED NORMAL.SDR UIEA2018053001004Charger · malfunctionedAPU BATTERY CHARGER STATUS MESSAGE. REPLACED THE APU BATTERY CHARGER IAW AMM 24-31-05. OPS CHECKED NORMAL.SDR UIEA201805290981Battery · dischargedAPU FAULT EICAS AFTER LANDING. FOUND LOW VOLTAGE ON THE APU BATTERY. REMOVED AND REPLACED THE APU BATTERY ASSY IAW AMM 24-31-04. OPS CHECKED GOOD.SDR UIEA201805290982Charger · low voltageAPU BATTERRY CHARGER HAD LOW OUTPUT. REMOVED AND REPLACED THE APU BATTERY CHARGER IAW AMM 24-31-05. OPS CHECKED OK.SDR P5CA2018041600060Warning Message · false activationBATTERY CHARGER STATUS INDICATED. COMPLETED FIM 24-31 FT 003 SYSTEM TEST. TESTED OK.SDR 29GA2018040200001Battery · overheatedNO BATTERY START LIGHT ILLUMINATED AFTER NR 2 ENGINE STARTED. TEMPERATURE RAISED DURING CRUISE AND RT BATTERY HOT LIGHT ILLUMINATED, PERFORMED AN EMERGENCY LANDING . R & R THE RT MAIN BATTERY IAW AMM 24-34-10-04. OPS CHECKED GOOD.SDR SIMA20180318002Pcb · burnedWHEN FO FIRST ARRIVED AT THE ACFT, NOTICED THE BATTERY MASTER SWITCH WAS LEFT ON. ELECTRICAL ODOR WAS PRESENT. GPU PLUGGED IN BUT NOT SELECTED. REMOVED AND REPLACED THE MAIN BATTERY AND APU BATTERY. ALL OPS CHECKED GOOD. REMOVED AND REPLACED THE LEFT DCPCSDR P5CA2018031700049Charger · malfunctionedSTATUS MESSAGE FOR THE APU BATTERY CHARGER. TRIED TO RESET THE APU BATTERY CHARGER CIRCUIT BREAKER BUT NO HELP. REMOVED AND REPLACED APU BATTERY IAW AMM 24-31-04, AND REMOVED AND REPLACED THE APU BATTERY CHARGE IAW AMM 24-31-05, TESTED OK.SDR FDEA201803170723Relay · faultyLEVEL ONE EMER POWER ON ALERT 4 HOURS INTO FLIGHT LEVEL CRUISE. REPLACED RELAY R2-5411 PER FIM 24-24-01-00. NO FAULTS NOTED. A/C OK FOR SVC.SDR ASAA2018030223739Circuit Breaker · trippedELEC AMBER LIGHT ILLUMINATED ON OVERHEAD PANEL. ACFT GROUNDED. FOUND AUX BATTERY CIRCUIT BREAKER TRIPPED. RESET THE CIRCUIT BREAKER IAW AMM 20-60-01. BITE TESTED IAW FIM 24-31 TASK 801. FOUND AUX BATTERY CHARGER FAILED AND STATIC INVERTER FAILED. CLEARESDR UIEA2018022500273Battery · defectiveAPU FAULT ON APU START. REMOVED AND REPLACED BATTERY CHARGER & BATTERY IAW AMM 24-31-05 / 24-31-04. OPS CKD GOOD.
Back to JASC 2432