SDR HEEA954969Regulator · malfunctionGENERATOR KICKS OFF INTERMITTENTLY DURING CROSS START.SDR HEEA954961Regulator · malfunctionCOULD NOT ADJUST OVERVOLTAGE. REPLACED Q4 TRANSISTOR P/N 03-0044-28, R65 RESISTOR P/N 05-508624. BENCH CHECK GOOD.SDR HEEA954928Regulator · defectiveGENERATOR WOULD NOT COME ON LINE.SDR HEEA954869Regulator · malfunctionREGULATOR CAUSING GEN. TO NOT COME ON LINE.SDR HEED9523Regulator · defective#2 ENGINE START DISENGAGE TRIPS BUSS INTERCONNECT, MUST RESET BATTERY SWITCH TO GET BUSS INTERCONNECT BACK ON LINE. ORDERED NEW PART.SDR 95ZZZX2564Generator · shortedVOLTAGE REGULATOR SHORTED BY ELECTRICAL PROBLEM IN GENERATOR CIRCUIT. TRACED TO EMERGENCY GENERATOR RESET BUTTON. REMOVED AND REPLACED VOLTAGE REGULATOR.SDR 95ZZZX2563Regulator · inoperativeVOLT REGULATOR INSTALLED, INOPERATIVE. REMOVED AND REPLACED VOLTAGE REGULATOR.SDR 95ZZZX2565Regulator · shortedVOLTAGE REGULATOR SHORTS BY ELECTRICAL PROBLEM IN GENERATOR CIRCUIT. TRACED TO EMERGENCY GENERATOR RESET BUTTON. REMOVED AND RESET VOLTAGE REGULATOR.SDR HEEA954723Volt Regulator · malfunctionGENERATOR COMES OFF LINE 8 TIMES IN 45 MINUTES OF FLIGHT.SDR 95ZZZX2562Regulator · inoperativeVOLTAGE REGULATOR INOPERATIVE. REMOVED AND REPLACED VOLTAGE REGULATOR.SDR 95ZZZX1978Regulator · failedVOLTAGE REGULATOR FAILED CAUSING AN OVER-VOLT CONDITON WHICH RESULTED IN SEVERAL WIRES BEHIND THE INSTRUMENT PANEL OVERHEATING AND CREATING SMOKE IN THE COCKPIT.SDR COM31052Gcu · defectiveLEFT DC GENERATOR FAILED IN FLIGHT. REPLACED THE LEFT GCU AND AIRCRAFT RETURNED TO SERVICE.SDR 95ZZZX2283Regulator · failedFLL/ATL - FLT 128 - EXPERIENCED AN ELECTRICAL MALFUNCTION WHEN THE RIGHT GENERATOR DROPPED OFF-LINE AFTER THE AIRCRAFT STARTED ITS ROLL FOR TAKEOFF. PILOT POWERED BACK AND PROCEEDED BACK TO THE GATE. CREW RESET CIRCUIT BREAKERS AND GENERATOR RESET TO NORMAL
Back to JASC 2436