SDR AUS20021407Cable · faulty(AUS) ALTERNATOR MAIN POWER CABLE FAULTY. CABLE WAS SPLICED CAUSING HIGH RESISTANCE. PERSONNEL/MAINTENANCE ERROR.SDR CA030106002Fuse · blown(CAN) FUSE (GMW1) HAS POPPED ON THREE DIFFERENT COMPANY B200 AIRCRAFT. FUSE PROJECTS 28 VDC OUTPUT CIRCUIT FROM THE EFIS STANDBY POWER SUPPLY (WIRES W3203-2 AND W3204-4). HAVE SUBMITTED QUERY TO RAYTHEON TECH SUPPORT FOR RECTIFICATION.SDR AUS20021263Contactor · unserviceable(AUS) BATTERY CONTACTOR SUSPECT FAULTY. WIRES W010-0013-24 ANDW010-0038-24 BURNT. INVESTIGATION FOUND THE BATTERY CONTACTOR K0455 PNO 170GC02-500 HAD A DISLODGED LEAF CONTACT ON TERMINAL S. THE LOOSE TERMINAL SHORT CIRCUITED CAUSING EXCESS CURRENT INWIRES.SDR SWIA200211406Relay · arcedRELAYS FO SIDE PANEL HOT. SMOKE ODOR IN COCKPIT. REPLACED APU FEEDER PROTECTION RELAY K0152 AND BUS BARS W1264, W163 DUE TO ARCING. OPERATED AIRCRAFT ELECTRICAL UNDER HEAVY LOADS ON APU GENERATOR WITHOUT CONTACTOR OR BUS BAR AREA SHOWING ANY SIGNS OF ABNORMSDR SWIA200211188Buss Tie · defectiveTURNING ON BATT MASTER, THE AROMA OF ELECTRICAL SMOKE EXISTED. NO CIRCUIT BREAKERS HAD POPPED. REPLACED BUSS TIE NR 2 CONTACTOR. TURNED ON BATT MASTER & RAN ALL SYSTEMS. NO SMOKE AROMA NOTED.SDR 02209409Control Unit · malfunctionedDURING THE CLIMB, THE CREW REPORTED THAT ELECTRICAL POWER HAD BEEN LOST. ALL 5DAU SCREENS WENT BLANK AND RADIO COMMUNICATION WAS INTERMITTENT. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO LGA AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONSDR 2002FA0000798Relay · burnedHAVE FOUND 2-3 RELAYS WITHIN PAST MONTH WITH BURNED CONNECTION TO MFG. THE MAIN BUSS CONNECTIONS OVER TIME HAVE TURNED BLACK AND HAVE ULTIMATELY FAILED.SDR MALA020349Power SupplyDURING LC1 FOUND MANY CABIN EMERGENCY LIGHTS INOP. MAINTENANCE REPLACED POWER SUPPLY AND BATTER SUPPLY (22LN) OPS CHECK GOOD.SDR 02157413Control Unit · failedDURING DESCENT OF THE FLIGHT FROM DAY TO CVG, THE CREW REPORTED THAT THE NR 1, 2 AND 3 FLIGHT DISPLAYS FAILED INTERMITTENTLY. THE AIRCRAFT WAS LANDED AT CVG WITHOUT INCIDENT. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE DC GENERATOR CONTROL UNIT (1VE PANELSDR AUS20020799Connector · faulty(AUS) NO2 GENERATOR FEED PLUG SUSPECT DIRTY.SDR AUS20020354Circuit Breaker · faulty(AUS) CARGO/LAVATORY CIRCUIT BREAKER SUSPECT FAULTY.SDR AUS20020303Current Limiter · failed(AUS) PILOT EXPERIENCED COMPLETE LOSS OF ELECTRICAL POWER WHEN THE UNDERCARRIAGE WAS RETRACTED AFTER TAKE-OFF. INVESTIGATION FOUND THE BUS 1 AND 2 CURRENT LIMITERS BLOWN. FURTHER INVESTIGATION FOUND THE ALTERNATOR BLOCKING DIODE HAD AN UNSERVICEABLEINSULATOR TSDR MALA020209Pdu · defectiveBEFORE TAKEOFF OF FLIGHT #3016, LEFT SIDE AVIONICS ARE LOST ANYTIME THE HYDRAULIC PUMP RUNS. RETURN TO GATE. MAINTENANCE REPLACED LH PDU, ALL CHECKS GOOD. SEE CONTINUATION CARD #063144 AND MM 409 #080345 FOR DETAILS.SDR UWU2002F00000Relay · failedAIRCRAFT ESS BUSS FILED, MESSAGE DISPLAYED ON ED NR 1, TROUBLESHOT PROBLEM TO AN INTERMITTENT AC ESS BUSS SENSE RELAY (K1XD) IN JB 18. REPLACED RELAY (K1XD), OPS TEST AC ESS BUSS SYSTEM, NO FAULTS NOTED. NOTE: ESS BUSS DID NOT FAIL, SENSE RELAY FAILED GIVINGSDR GLBA2002026Warning System · malfunctionedLEFT GEN TIE ANNUNCIATOR ILLUMINATED IN-FLIGHT. COULD NOT DUPLICATE.SDR GLBA2002024Printed Ckt Board · faultyBATTERY TIE OPENED INFLIGHT. REPLACED BUSS TIE PCB, OPS CHECKED SYSTEM SATISFACTORY.SDR DLM88020209Relay · burnedRELAY R2-50 GROUND SERVICE BUS TIE WAS FOUND BURNT AND TERMINALS A2 AND B2 SHORTED. REPLACED SAME.SDR MALA020142Pdu · defectiveA/C was originally on a Reposition Flight #422 from ABE-DTW. Enroute to DTW LH Main Buss dropped off line. Crew lost all Flight instruments on LH (Capt) side. Due to weather, Flight was diverted to FNT. Maintenance removed and replaced RH PDU PN A2043C, SNSDR AUS20020084Circuit Breaker · failed(AUS) CIRCUIT BREAKER FAILED.SDR MALA020139Pdu · defectiveDuring Flight #3185, RH Buss failed inflight. FO's Efis Displays (both) went blank. Maintenance replaced RH PDU then Buss failed again. Maintenance replaced LH PDU, and replaced Relay 72 PC. See 409 #080284 for details.SDR GLBA2002012Connector · looseANNUNCIATOR POWER SOURCE ILLUMINATED IN FLIGHT. RESEATED CONNECTOR ON PCB, OPS CHECKED SYSTEM SATISFACTORY.SDR RAIA00201027Pdu · inoperative5587-STL- RIGHT BATTERY ANNUNCIATOR LIGHT ILLUMINATED DURING TAXI. MAINTENANCE REMOVED AND REPLACED THE POWER DISTRIBUTION UNIT - OPS CK OK.SDR CHQ00098Electrical Box · shortedPILOT REPORTS SMOKE IN COCKPIT FROM F/O'S RELAY BOX.SDR CHQ00097Electrical Box · shortedPILOT REPORTS SMOKE IN COCKPIT FROM F/O'S RELAY BOX.SDR AALA20020077Circuit Board · failedLHR - FLT 131 - ONE HOUR AND 20 MINUTES INTO FLIGHT RIGHT MAIN AC BUSS FAILED WITH THE FOLLOWING EICAS MSGS. BULK AFT CARGO HEAT, ELMSP210 PANEL, RAT GEN HEAT, AIR GRNG R, RECIRCULATION FAN. DIVERTED TO LHR, DECLARED EMERGENCY, LANDING WEIGHT 452,00. TROUBLSDR 2002FA0000169Circuit Breaker · arcedCOCKPIT FILLED WITH SMOKE AND ODOR OF BURNING MATERIAL. INSPECTION OF WIRING AND SYSTEM INSTALLATION, FOUND ONE TERMINAL ON POWER CIRCUIT BREAKER PANEL WITH EVIDENCE OF ARCING, BUT NOT RELATED TO THIS UNITS OPERATION SOME INTERNAL FAILURE HAS OCCURRED, W HESDR CA011231003Diode · burned(CAN) PILOT HAD MULTIPLE FAILURES WHEN COMING IN TO LAND, SOME EXTERIOR AND INTERIOR LIGHTS WOULD NOT WORK AND THE LANDING GEAR WOULD NOT COME DOWN. THE PILOT EXTENDED THE GEAR MANUALLY AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE RT NR 1 BUSS FEEDER SDR HYI2001F00013Master Switch · failedON PREFLIGHT INSPECTION, AVIONICS MASTER SWITCH FAILED. MAINTENANCE REPLACED SWITCH AND RETURNED AIRCRAFT TO SERVICE.SDR CA020117010Circuit Breaker · broken(CAN) AT A ROUTINE 100 HOUR ANNUAL INSPECTION IT WAS DISCOVERED THAT TWO CIRCUIT BREAKERS HAD BROKEN REAR ATTACHMENT LUG AT THE BUS BAR ATTACH POINT.SDR HYI2001F00012Master Switch · failedON PREFLIGHT INSPECTION, AVIONICS MASTER SWITCH FAILED. MAINTENANCE REPLACED SWITCH AND RETURNED AIRCRAFT TO SERVICE.SDR RAIA00111007Fuse5273-RIC-CREW REPORTED DC BUSS #2 FAILURE, #2 ENGINE POWER LOSS, AND #1 HYDRAULIC SYSTEM FAILURE. MAINTENANCE TROUBLESHOT AND FOUND THE #2 DC BUSS FUSE BLOWN AND REPLACED FUSE IAW EMB 145 MM.SDR HYI2001F00005Master Switch · failedON PREFLIGHT INSPECTION AVIONIC MASTER SWITCH FAILED. MAINTENANCE REPLACED SWITCH AND RETURNED AIRCRAFT TO SERVICE.(K)SDR SWIA200110303Relay · failedWHEN CLIMBING TO ALTITUDE THE ELEC LIGHT ON MAP LIGHT UP AND EMERGENCY BUS OFF LIGHT CAME ON, ON THE OVERHEAD PANEL. EMERGENCY BUS 2CB (F10) AND DC INDICATION NR 2 (G4) BOTH POPPED. ATTEMPTED ONE RESET AND SAME THING HAPPENED AGAIN. BOTH TIMES THE CB'S POPPSDR POF2001F00000Switch · overheatedALTERNATOR SWITCH OVERHEATED.SDR HYI2001F00006Master Switch · failedON PREFLIGHT INSPECTION AVIONICS MASTER SWITCH AND RETURNED AIRCRAFT TO SERVICE.SDR HYI2001F00003Master Switch · failedON PREFLIGHT INSPECTION, AVIONICS MASTER SWITCH FAILED. MAINTENANCE REPLACED SWITCH AND RETURNED AIRCRAFT TO SERVICE.SDR HALA0100248Rccb · failedLAX - FLT 32 - AIR DIVERSION AT 3 HOURS INTO FLIGHT, LT EMERGENCY AC BUS OFF LIGHT ILLUMINATED, RESTORED SYSTEM. FOLLOWED CHECKLIST, 5 MINUTES LATER PROBLEM REOCCURRED. NR 1 GALLEY POWER OFF LIGHT ILLUMINATED. COULD NOT RESTORE POWER BY RESETTING, REMAINED SDR HYI2001F00002Master Switch · inoperativeCREW REPORTED AVIONICS MASTER SWITCH INOPERATIVE ON PREFLIGHT. MAINTENANCE REMOVED AND REPLACED SWITCH AND RETURNED AIRCRAFT TO SERVICE. (PTRS-2001B5540)SDR HYI2001F00001Master Switch · failedWHILE AIRCRAFT WAS TAXING, AVIONICS SYSTEM FAILED. CREW ENGAGED EMERGENCY AVIONICS BY PASS SWITCH, AND RETURNED TO THE GATE. MECHANICS REMOVED AND REPLACED AVIONICS MASTER SWITCH AND RELEASE AIRCRAFT BACK TO SERVICE.SDR NSVA0115Control Panel · faultyDURING TAKEOFF ROLL FROM ACK, PILOTS NOTED AUTO FEATHER LIGHT DID NOT COME ON, ALSO LEFT AND RIGHT ANTI-ICE C/B POPPED. CAPTAIN ELECTED TO ABORT TAKEOFF AND RETURN TO GATE. MAINTENANCE TROUBLESHOT PROBLEM DOWN TO BAD LEFT BUS TIE RELAY. REMOVED AND REPLACEDSDR AUS20011049Circuit Breaker · failed(AUS) NR 1 AVIONICS SWITCH / CIRCUIT BREAKER FAILED INTERNALLY. SUSPECT CAUSED BY RAIN WATER CORROSION DUE TO LOCATION OF CIRCUIT BREAKER BELOW THE LT OPENING WINDOW.SDR 2001FA0000352Buss · damagedPILOT REPORTED LOSS OF HALF OF AVIONICS BUSS, INCLUDING ONE NAV/COM AND GPS AND SMOKE AND A BAD ODOR IN THE COCKPIT. WIRE NR 2H1002 (22 GAUGE) BURNED FROM THE NAV. LIGHT C/B SWITCH TO PIN 11 OF THE JC001 CONNECTOR AND FROM PC001, PIN 11 TO JV001, PIN 1. TSDR COMA0160730Connector · burnedUPON APPLYING ELECTRICAL POWER TO AIRCRAFT FOR MAINTENANCE SEVERAL AVIONICS COOLING SYSTEM AND FLIGHT RECORDER SYSTEM CIRCUIT BREAKERS POPPED, ACCOMPANIED BY VARIOUS FAILURES OF COCKPIT PANEL BACKLIGHTING. INVESTIGATION FOUND THE JUNCTION BOX (JB-2) ELECTRICASDR HYI2001F00004Circuit Breaker · failedAVIONIC CIRCUIT BREAKER/SWITCH FAILED IN FLIGHT CAUSING COMPLETE AVIONIC FAILURE CREW UTILIZED EMERGENCY AVIONIC BUS SWITCH AND LANDED WITHOUT INCIDENT. SEVERAL SUCH FAILURES RECORDED RECENTLY. THIS SWITCH HAS A HIGH UTILIZATION FACTOR.(K)SDR GLBA2001205Fuse · looseANNUNCIATOR POWER SOURCE ILLUMINATED ON T/O. INSPECTED FOUND LOOSE CONNECTION ON PICO FUSE ON PCB A141. REPLACED BOARD, OPS CHECKED SYSTEM SATISFACTORY.SDR GLBA2001202Control Panel · defectiveLEFT GENERATOR FALLS OF LINE. REPLACED DC PWR PANEL, OPS CHECKED SYSTEM SATISFACTORY.SDR SWIA200110099Circuit Breaker · trippedON APPROACH TO PDX, EMERGENCY DC BUS 2 FAILED WHEN FLAPS WERE SELECTED 15 DEGREES.REMOVED AND REPLACED EMERGENCY DC BUS 2 CIRCUIT BREAKER IAW WM 20-00-07. NO DEFECTS NOTED.SDR SWIA200110098Buss · failedON APPROACH TO SEA THE ''EMERGENCY BUS OFF" LIGHT ON OVERHEAD PANEL LIGHT CAME ON, AND ON THE MAP PANEL THE AMBER APU, ELECTRIC, POWER OFF, DEICE AND BRAKES LIGHTS CAME ON. FOLLOWED QRH PROCEDURE TO AFM 3-8 PROCEDURE - EMERGENCY DC BUS FAILED.RESET EMERGENCY SDR 2001FA0000165Circuit Breaker · failedDURING FLIGHT, SMOKE WAS OBSERVED COMING FROM THE REAR OF A CB PANEL. CB'S PULLED PROGRESSIVELY TO IDENTIFY ONE CAUSING SMOKE. OTHERS RESET AFTER ISOLATING FAULTY ONE. AIRCRAFT LANDED. ON GROUND, FAILED CB REPLACED. FURTHER TROUBLE SHOOTING REVEALED. POWER WISDR 2001FA0000240Relay · damagedPILOT REPORTED SMOKE IN COCKPIT AND THEN CABIN FAN CIRCUIT BREAKER POPPED. FOUND LOAD BUS RELAY PN 688498 LOCATED BELOW RIGHT CIRCUIT BREAKER PANEL, WITH A HOLE BURNED IN IT. WITH CIRCUIT BREAKER PULLED, THE SMOKE WENT AWAY. PILOT RETURNED AIRCRAFT TO FACTO
Back to JASC 2460