JASC 2520
Service difficulty reports · 2,086
Reports filed under 2520 · Passenger Compartment Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2520' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2520' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013041602610Trim Panel · unsecureAFT GALLEY FLOOR TRIM BY AFT ROW OF CARTS IS COMING UP HARD TO PULLOUT CARTS. SECURED TRANSITION STRIP DOWN PER EC-RA# 2525-01497. ECRA COMPLIED WITH. (TRANSITION PART NOT AVAIL FOR REPLACEMENT)SDR UALA2013041002427Bumper · unsecureCREW REPORT: SEAT BUMPER STRIP 27D COMING OFF. SEAT BUMPER REMOVED AND STOWED IN CLOSET. REPLACED BUMPER WITH NEW. OK TO CONTINUE.SDR UALA2013041002428Armrest · brokenARMREST CAP BROKEN AT SEAT 24D. INTERIM REPAIR REF EC-RA 2521-02520. RPR- :RESEATED ARMCAP IN PLACE.SDR UALA2013041002424Trim Panel · tornFLOOR TRIM BY 29F IS TORN. FLOOR TRIM HAS BEEN REMOVED, OKAY TO CONTINUE. PARTS: 110-3219 (ABS5310-01 - PROFILE) LOB: NSDR UALA2013040802300Armrest · looseARMREST-CONSOLE LOOSE (ROCKS) AT 26D. ARMREST LOOSE. REPAIRED USING ECRA 2521-02520. NEEDS ARMREST, PCN 005-5512. REMOVED AND REPLACED ARMREST ON SEAT 26D. OPS CHECKS GOOD. OK TO CONTINUE.SDR R61A201304070353Psu · unsecureCREW REPORTED THAT THE PSU PANEL OVER ROW 18D DROPPED. MAINTENANCE RESECURED PSU PANEL PER BOMBA AMM AND OPS CHECKED GOOD.SDR UALA2013040802336Carpet · mismanufacturedPER IPC 33-52-00 AIRCRAFT IS MISSING EEL FLOOR LAMP IN FRONT OF AFT FWD LAV DOOR. EEL FLOOR LAMP IS PRESENT BUT IS COVERED BY CARPET. TRIMMED CARPET AND REPAIRED EEL LAMP PER MM AND IPC. OP CHECKS OKAY.SDR R61A201304050352Psu · unsecureCREW REPORTED THAT THE PSU OVER SEAT 1A FELL DOWN. MAINTENANCE RESECURED PSU PER BOMBA AMM AND OPS CHECKED GOOD.SDR UALA2013040502290Support Bracket · detachedSEAT 40D LIFE VEST POUCH SUPPORT BRACKET IS DETACHED FROM THE SEAT. SECURED BRACKET.SDR UALA2013040302180Seat · looseSEAT ASSY 36ABC LOOSE. SECURED SEAT 36ABC.SDR UALA2013040302176Tube · out of positionOXYGEN PANEL DOOR FELL OPEN 24DEF. MASKS DID NOT DEPLOY. OXY DOOR DID NOT OPEN. THE RUBBER TUBING ALONG THE PSU CAME OUT AND CAUSED THE PSU TO DROP SLIGHTLY. INSTALLED TUBING AND PSU INTO PLACE.SDR USAA2013040200025Seat · out of adjustEXIT ROW 9D RECLINES INTO EXIT AISLE. LOCKED SEAT 9D UPRIGHT IAW AIRCRAFT MAINTENANCE MANUAL 20-25-01.SDR UALA2013040102077Psu · damagedO2 MASK DOWN ROW 38. OVERHEAD PSU DAMAGED, HINGE BROKEN. PSU INOP, NO OXYGEN ROW 38CDEFG. REPLACED OXYGEN PSU AT CENTER ROW 38 IAW MM.SDR UALA2013040202117Window Shade · stuckRIGHT OVERWING EMERGENCY EXIT WINDOW SHADE STUCK. REPLACED WINDOW SHADE ASSY AT AFT RT DOOR, OPS CKD NORMAL. OK TO CONTINUE.SDR UALA2013040402235Seat · looseSEAT ROW 32 DEF LOOSE IN SEAT TRACK. SECURED SEAT ASSY, OPS CHECKED GOOD. VERIFIED SEAT PITCH AND SECURITY.SDR USAA2013040100012Transformer · overheatedCREW REPORTED AN ELECTRICAL SMELL IN FORWARD HALF OF A/C BOTH WITH EXTERNAL AIR AND APU AIR. MAINTENANCE PERFORMED J/C 26L00021001 AND FOUND PSU TRANSFORMER AT ROW 3A/C OVERHEATED. PER AMM, REMOVED AND REPLACED PSU IAW AMM 25-25-11-000-001A. PSU AT ROW 3A/CSDR USAA2013032900001Sign · detachedFORWARD ENTRY EXIT SIGN FELL DOWN. MAINTENANCE INSTALLED FWD EXIT SIGN.SDR UALA2013032902053Seat · brokenFORWARD CABIN F/A INBRD JUMP SEAT BROKEN BY 1L. UNTANGLED SEAT-BELTS.SDR R61A201303230315Bushing · missingWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE EMERGENCY ABSORPTION SYSTEM PLUG BUSHING MISSING. MAINTENANCE INSTALLED BUSHING IAW EMB 170 C AND D ZODIAC CMM 25-22-51. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201303230314Plug · damagedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE EMERGENCY ABSORPTION SYSTEM PLUG DAMAGED ON SEAT 4A. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY ABSORPTION SYSTEM PLUG IAW EMB 170 C AND D ZODIAC CMM 25-22-51. THE AIRCRAFT IS OUT OF SERVICE IN HEAVSDR R61A201303230313Structure · damagedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE EMERGENCY ABSORPTION SYSTEM QUADRANT DAMAGED ON SEAT 4A. MAINTENANCE REMOVED AND REPLACED THE QUADRANT IAW EMB 170 C AND D ZODIAC CMM 25-22-51. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201303230312Plug · misinstalledWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE EMERGENCY ABSORPTION SYSTEM QUADRANTS DAMAGED FROM IMPROPER INSTALLATION OF PLUG ON SEATS 8D, 10CD, 13D, 14D, 15D, AND 17D. MAINTENANCE REMOVED AND REPLACED THE QUADRANTS IAW EMB 170 CMM 25-22-50. THE ASDR R61A201303230311Plug · misinstalledWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE EMERGENCY ABSORPTION SYSTEM QUADRANT PLUGS INSTALLED INCORRECTLY, AND DAMAGED ON SEATS 8D, 10CD, 13D, 14D, 15D, AND 17D. MAINTENANCE REMOVED AND INSTALLED THE QUADRANT PLUGS IAW EMB 170 CMM 25-22-50. THSDR R61A201303180285Psu · out of positionCREW DISCOVERED THAT THE PSU PANEL ABOVE SEATS 12 D & F HAD FALLEN DOWN. MAINTENANCE RE-INSTALLED PSU PANEL PER BOMA AMM 25-28-0 AND OPS CHECKED GOOD.SDR R61A201303170283Psu · unsecureCREW REPORTED THAT THE PSU PANEL ON THE RIGHT SIDE OF ROW 13 DROPPED. MAINTENANCE RE-INSTALLED THE PSU PER BOMBA AMM 25-28-0 AND OPS CHECKED GOOD.SDR R61A201303170277Psu · unsecureCREW REPORTED THAT A PSU PANEL CAME DOWN DURING TAXI. CREW RETURNED TO GATE WHERE MAINTENANCE RE-SECURED PSU PANEL PER BOMBA AMM AND OPS CHECKED GOOD.SDR CA130321003Light · overheated(CAN) CBP-1 P4, CABIN UTILITY CIRCUIT BREAKER POPPED. MAINTENANCE FOUND FIRST CLASS CLOSET LIGHT FIXTURE IS BURNED WITH BROKEN WIRES.SDR UALA2013030801394Hinge · out of adjustOVERHEAD BIN 19DEF DOOR LATCH BROKEN. ADJUSTED OVERHEAD BIN HINGE.SDR R61A201303050222Psu · unsecureCREW REPORTS PSU FELL OVER ROWS 16 & 17 D AND C. MAINTENANCE RE-SECURED PER BOMBA AMM 25-28-0 AND OPS CHECKED GOOD.SDR USAA2013030600011Actuator · out of adjustSEAT 8DEF RECLINES TOO FAR INTO EXIT ROW AND WILL NOT STAY UP. MAINTENANCE ADJUSTED SEAT ACTUATOR, JAM NUTS AND RECLINE POSITION.SDR UALA2013030101227Trim Panel · out of positionCREW REPORT: ROW 24DEF LOWER BULKHEAD TRIM PIECE STICKING UP. STRAIGHTENED METAL TRIM AND TAPED IN PLACE. NO PASSENGER HAZARD.SDR 2013FA0000136Seat Frame · crackedDURING ANNUAL INSPECTION, FOUND PASSENGER SEAT WITH THE MAIN FRAME CRACKEDSDR UALA2013022701193Panel · unsecureCEILING PANEL FIRST CLASS NEEDS TO BE SECURED. AFT LATCH BROKEN. REPLACED LATCH AND LANYARD. RE-INSTALLED CEILING PANEL.SDR UALA2013021400877Seat · unsecureSEAT ROW 37 ABC NOT ATTACHED TO FLOOR. SECURED SEAT IN PLACE PER AMM.SDR UALA2013021300861Panel · unsecureCENTER CEILING PANEL ROW 28-29 RT SIDE HANGING DOWN APPROX 2 INCHES. REPOSITION CEILING PANEL. CHECK OKAY.SDR UALA2013021100807Window Shade · damagedWINDOW SHADE AT SEAT 20A DAMAGED OVERWING EXIT. REPLACED WINDOW SHADE.SDR USAA2013021100020Window Shade · stuckCREW REPORTS DOOR R2 WINDOW SHADE STUCK IN DOWN POSITION. MAINTENANCE FREED UP R2 WINDOW SHADE. OPS GOOD.SDR REXA2013020600274Door · out of adjustTHE FLIGHT ATTENDANT COMPARTMENT WITH THE EMERGENCY EQUIPMENT THE DOOR IS TOO STIFF TO OPEN. ADJUSTED THE FLIGHT ATTENDANT COMPARTMENT DOOR WHERE THE EMERGENCY EQUIPMENT IS STORED IAW CRJ AMM 25-42-01.SDR UALA2013020500701Window Shade · brokenAT DOOR 2L, WINDOW SHADE BROKEN. REPLACED WINDOW SHADE ASSY.SDR QXEA2013020200269Structure · malfunctionedF/A REPORTS THAT THE DOOR TO THE COMPARTMENT UNDER THE AFT F/A JUMPSEAT DOES NOT CLOSE PROPERLY. R & R AFT JUMPSEAT OTBD LOWER BASE/SEAT ASSY IAW AMM TASK 25-22-00-000-803, STEP 1-4A, PARA (6) AND 25-22-00-400-803, STEPS 1-4 A PARA (1) AND STEP 5. OPS CHECK SDR UALA2013020400668Pin · unsecureSEATS 34D, E & G APPEAR LOOSE. SEAT ASSY VERIFIED SECURE IN FLOOR TRACKS. SEATBACK BUSHINGS WORN CAUSING UNDESIRED PLAY. SEATS SECURE IN UPRIGHT POSITION. FOUND 34D RECLINE ACTUATOR PIP PIN LOOSE. SECURED PIN. CHECKED OKAY.SDR UALA2013012900529Gate · unsecureTOP LATCH ON SECURITY GATE DOES NOT STAY LATCHED. SECURED WITH TY WRAPS IN STOWED POSITION. REPLACED SECONDARY BARRIER GATE.SDR SCNA20130208054Insert · corrodedFORWARD LAV FLOOR HAS 4 BAD INSERTS AT LOWER DOOR FRAME. REMOVED & REPLACED 4 CORRODED INSERTS IN FORWARD LAV FLOOR AT LOWER DOOR FRAME.SDR SCNA20130208053Insert · corrodedRIGHT AFT LAV FLOOR HAS 1 BAD INSERT. REMOVED & REPLACED 1 CORRODED INSERT IN RIGHT AFT LAV FLOOR.SDR SCNA20130208052Insert · corrodedLEFT AFT LAV FLOOR HAS 2 BAD INSERTS. REMOVED & REPLACED 2 CORRODED INSERTS IN LEFT AFT LAV FLOOR.SDR SIMA20130125003Unknown · dirtyFOR FLIGHT 3325 THE CREW REPORTED THE AIRCRAFT CABIN HAD A STRONG ODOR OF FISH. THE CREW RECEIVED MANY COMPLAINTS FROM THE PASSENGERS. THE AIRCRAFT WAS REMOVED FROM SERVICE. INTERIOR CLEANING AND DISINFECTING OF FISH ODOR IAW STANDARD PRACTICES. THE AIRCRASDR UALA2013012100374Bolt · looseLOOSE BOLT THAT SECURES SEAT 28DEF TO FLOOR. REMOVED SEAT ROW FROM TRACKS. INBOARD SEAT TRACK DAMAGED. INSTALLED NEW NUT AND STUD, RE-INSTALLED SEATS.SDR UHLA2013011700011Overhead Bin · dirtyFLIGHT ATTENDANT REPORTS SULFUR TYPE SMELL IN CABIN DURING ALL PHASES OF FLIGHT. THE SMELL WAS CONSISTENT, DID NOT GET ANY WORSE OR ANY BETTER. PERFORMED OPS CHECK OF BLEED SYSTEM AND PACKS IAW AMM 36-00-00. NO FAULTS FOUND. INSPECTED OVERHEAD BINS, FOUND SDR SWAA2013012311743Reveal · brokenBROKEN REVEAL ON LEFT OVERWING EMERGENCY EXIT DOOR. REMOVED AND REPLACED REVEAL ON LEFT EMERGENCY EXIT DOOR IAW AMM 25-21-12.SDR UALA2013010400060Psu · unsecurePAX OXYEN GENERATOR UNIT HANGING DOWN FROM OVERHEAD AT ROW 25DEF, NOT JUST MASKS. FOUND PSU PANEL AT 25DEF HANGING BY LANYARD. VERIFIED O2 MASKS AND GENERATOR INTACT AND UNFIRED. RELATCHED PSU PANEL AND OK FOR SERVICE.
Back to JASC 2520