SDR DALA2025070805163Retainer · crackedSHIP 3122 DURING INSPECTION OF AFT GALLEY G5 FOUND IN COMPARTMENT 510F O/B TROLLEY RETAINER BLOCK HAS CRACK 3/8" LONG. CORRECTIVE ACTION: COMPLIED WITH ER/A 627623-4. (7732415).Jul 7, 2025 · N322NB · Airbus A319114SDR DALA2025070805161Retainer · crackedSHIP 3122 DURING INSPECTION OF AFT GALLEY G5 DOUND IN COMPARTMENT 512F CRACK IN I/B TROLLEY RETAINER BLOCK 5 INCHES LONG AND O/B TROLLEY BLOCK CRACK 3/4" LONG. CORRECTIVE ACTION: COMPLIED WITH ER/A 627623-14. (7732413).Jul 7, 2025 · N322NB · Airbus A319114SDR DALA2025070805160Retainer · crackedSHIP 3122 FOUND CRACK ON COMPARTMENT 510 O/B TROLLEY RETAINER BLOCK. CORRECTIVE ACTION: COMPLIED WITH ER/A 627623-4. (1069491).Jul 7, 2025 · N322NB · Airbus A319114SDR DALA2025070705022Retainer · corrodedSHIP 3130 CORROSION ON TROLLEY RETAINER BLOCK COMPARTMENTS 110, 111 AND 112 OF G ALLEY 1 AT FWD GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 626879-14. (1067145).Jul 6, 2025 · N330NB · Airbus A319114SDR CALA2025070706271Coffeemaker · faultedAIRCRAFT GATE RETURNED DUE TO SMELL OF SMOKE IN AFT GALLEY. FLAGGED AS SDR FOR A/R DEBRIEFED FA AND STATED THAT A POPPING SOUND IN AFT GALLEY WAS HEARD AND VISIBLE WHITE SMOKE CAME FROM COFFEE MAKER GRILL AREA (SEE PHOTO) WITH AN ELECTRICAL BURN ODOR. FA OPENEJul 5, 2025 · N66893 · Boeing 737924ERSDR DALA2025070805164Retainer · crackedSHIP 3122 DAMAGES ON THE G5 GALLEY COMPARTMENTS 510, 511, 512 TROLLEY RETAINER AREA. CORRECTIVE ACTION: ACCOMPLISHED ER/A 627623-14. (1061643).Jul 3, 2025 · N322NB · Airbus A319114SDR CALA2025070306206Hose · brokenALL CHILERS FAILED ON DEPARTURE DURING VISUAL INSPECTION FOUND #3 SCU (ICS OUT) HOSE COUPLING BROKEN REF LOG PAGE #5417191 FOR CORRECTIVE ACTION. COMPLIED WITH INTEGRATED COOLING SYSTEM DEAERATING REF AMM 21-53-00-00A-255C-A. COMPLIED WITH OPS CHECKS AND LEAKJul 2, 2025 · N15969 · Boeing 7879SDR DALA2025062904820Coffeemaker · odorBURNING PLASTIC SMELL FROM AFT GALLEY. FOUND AFT GALLEY COFFEE MAKER POSITION A508 WITH DAMAGE TO WIRING. DEFERRED COFFEE MAKER. LATER, REPLACED HARNESS IN COMPARTMENT F107AND COMPLIED WITH ER/A 627359-14. (LP 7094022, 7094003)Jun 26, 2025 · N530DE · Airbus A321271NXSDR CALA2025062705989Oven · contaminatedAFT GALLEY OVENS 707/708 CAUSED HAZE AND ELEC ODOR FROM VENT BEH IND SPOKE WITH CREW ON INBOUND, OVEN 707 WAS THE ISSUE - REAR FAN VENT OF OVEN IS SCORCHED WITH BURNT FOOD AND FAN LOOKS TO BE BURNT TOO. REQUIRES REPLACEMENT. OVEN 708 OPS OK, NO SMELL WHEN SWITJun 25, 2025 · N227UA · Boeing 777222SDR CALA2025062605890Lavatory · dirtyAFT LEFT LAV SPILLED SEWAGE-SMELLING LIQUID ON TAKEOFF. LAV CURRNT U/S. AFT FLOOR NEEDS CLEANING PERFORMED OPS CHECK OF TOILET AND SINK IN LAV D AS REQUIRED. VERIFIED NO LEAKS. CLEANERS SANITIZED AREA. OK FOR SERVICE.Jun 25, 2025 · N17289 · Boeing 7378SDR CALA2025062505868Oven · failedREF HISTORY OF AFT GALLEY SMELL/CB POPPING SEE LOG 5310250/ 5261450/5263366. PER SSM 25-31-14 REMOVE AN OVEN AND VERIFY IFM 25-38-35 PG 2141 3 PHASE POWER AT OVEN IS CORRECT BETWEEN PHASES. START SOME OVENS AND VERIFY EACH PHASE VOLTAGE DROP AS OTHER OVENS AREJun 24, 2025 · N12005 · Boeing 78710SDR CALA2025062605907Oven · odorELEC SMELL ON T/O AGAIN ON LANDING BUT MUCH STRONGER SPOKE TO FLIGHT CREW IN AFT GALLEY AREA WHERE SMELL WAS OBSERVED. NO SMOKE NOTED BUT THEY FEEL THE SMELL WAS AT OVENS 708 AND 711. ESFR LOG REQ EXAMINED P100 CK2425502 AND L20/21/7 FOR DEFECTS NONE FOUND. VIJun 23, 2025 · N12005 · Boeing 78710SDR VNAA2025062511101Coffeemaker · odorTHE FLIGHT CREW REPORTED A BURNING POPCORN SMELL WHILE ENROUTE. THE SMELL DISSIPATED. NO MEDICAL ATTENTION REQUIRED. PERFORMED OPS CHECK OF THE TEMPERATURE CONTROL SYSTEM IAW AMM 21-60-00-710-801. OPS CHECK GOOD AT THIS TIME. DURING OPS CHECK, NO ODORS WERE Jun 21, 2025 · N529EA · Cndair CL6002C10SDR CALA2025062305794Oven · dirtyGALLEY OVENS 705 AND 706 BREAKERS WERE PULLED BY FA DUE TO SUSPECTED SMOKE FROM BEGIND THEM. PER CONDITIONAL INSPECTION 05-51-58, SOURCE WAS ISOLATED TO BEHIND OVENS 705 AND 706. REMOVED OVENS 705 AND 706 IN REFERENCE TO AMM 25-32-02 AND INSPECTED BEHIND THEM Jun 20, 2025 · N787UA · Boeing 777222SDR CALA2025062305785Oven · dirtyOVEN 606 SMOKING INSPECTED OVEN REF AMM 05-51-58 AND FOUND SOURCE TO BE OVEN 606. FOUND BURNING/BURNT FOOD MATERIAL ALONG BOTTOM LINING AND CLEANED. RAN THROUGH OPS CHECKS AND NO SMOKE CREATED REF AMM 25-32-02. SUSPECT STEAM FUNCTION OF OVEN EXACERBATED EFFECTJun 20, 2025 · N787UA · Boeing 777222SDR DALA2025061904602Coffeemaker · odorSHIP 3238 DISC: APPROX 10 MIN AFTER TAKEOFF FA'S REPORTED ELECTRICAL SMELL IN BACK {ROWS 25-32} ODOR DISSIPATED WITHIN A FEW MINUTES. C/A: INSPECTED ENGINES AND APU NO SIGNS OF OIL. PERFORMED ENGINE AND APU PNEUMATIC RUN NO SIGN OF SMOKE SMELL. REMOVED AND REPJun 18, 2025 · N338NW · Airbus A320212SDR DALA2025061904597Coffeemaker · odorSHIP 3221 DISC: AFTER PUSHBCK FLT ATTENDANT REPORTED AN ELECTRICAL SMELL IN THE AFT GALLEY, ALSO REPORTED THAT THE FLOOR FELT UNUSUALLY WARM IN FRONT OF THE AFT JUMPSEATS. C/A: /S PER A320 W/C 0550-2002 DECISION TREE. FLT ATT REPORTS ELEC SMELL BY COFFEE MAKERJun 17, 2025 · N321US · Airbus A320211SDR CALA2025061705591Oven · odorAIRCRAFT SMELLS OF MILDEW AND IS INC IN INTENSITY. PAX ARE UNCOM FORTABLE DEBRIEFED CREW ON ARRIVAL, CREW SAYS SMELL IS MAINLY COMING FROM MID LAV TO FWD OF CABIN UPON INVESTIGATING ODOR, FOUND FOOD IN FWD GALLEY OVEN TO BE SPOILED AND TO BE THE CAUSE OF BAD SJun 16, 2025 · N37408 · Boeing 737924SDR AALA202506182806Oven · contaminatedAIRCRAFT WAS NOT GROUNDED: FA REPORTS BURNING SMELL COMING FROM FWD RIGHT OVEN (98-06-10861). WE COULD SMELL IT IN THE COCKPIT AS WELL. OVEN CONFIRMED AS SOURCE CB COLLARD. **SUPPLEMENTAL REPORT FOR SDR AALA202506162806.** (CLOSED)** MAINTENANCE FOUND BURNED FJun 13, 2025 · N827AW · Airbus A319132SDR CALA2025061705626Oven · contaminatedOVEN 204 CREATED SMOKE I N THE GALLEY. SMOKE ALAR M BRIEFLY WENT OFF. FOUND BURNT FOOD AND DEBRIS AT THE BOTTOM OF THE OVEN. ACPED MEL. PLACED OM DF 2500BI. PLACED ON MEL. CLEAN OIL RESIDUE INSIDE OVEN #204, SMOKE STILL VISIBLE AFTER OPS CHECKING. PARTS NOT AJun 13, 2025 · N17402 · Boeing 7379SDR AALA202506162806Oven · odorAIRCRAFT WAS NOT GROUNDED: FA REPORTS BURNING SMELL COMING FROM FWD RIGHT OVEN (98-06-10861). WE COULD SMELL IT IN THE COCKPIT AS WELL. OVEN CONFIRMED AS SOURCE CB COLLARD. (OPEN)Jun 13, 2025 · N827AW · Airbus A319132SDR CALA2025061305545Oven · odorCHILLER 208 FWD GALLEY HAD ELECTRICAL ODOR THEN SHUT DOWN.ODOR S TOPPED SDR HAS BEEN FLAGGED PER GMM 04-20-16 3B (5) ACCOMPLISHED CONDITIONAL INSPECTION REF. AMM. TASK 05-51-58-800-801-C3. ABLE TO VERIFY THAT ELECTRICAL ODOR COMING OUT OF OVEN #108. G11. PLACIJun 10, 2025 · N74007 · Boeing 777224SDR AALA202506181962Oven · contaminatedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT IS SAYING THE NUMBER 1 OVEN HAS A BURNING SMELL WHEN USED. REMOVE AND REPLACE NUMBER 1 OVEN. PER AMM 25-32-03. OPERATIONAL CHECK GOOD.Jun 9, 2025 · N882NN · Boeing 737823SDR AALA202506101962Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTANDENT IS SAYING THE NUMBER 1 OVEN HAS A BURNING SMELL WHEN BEING USED. * (OPEN).Jun 9, 2025 · N882NN · Boeing 737823SDR HALA20250606031Lavatory · pax errorINFO TO MX FA REPORTED SOMEONE SMOKING IN LAV/STARTED A SMALL FIRE. FA EXTINGUISHED WITH WATER, NO AGENT DISCHARGE. PERFORMED PRECAUTIONARY CHECK OF LAV FIRE EXTINGUISHER. NO DAMAGE NOTED. PER AMM 26-25-01-212-801. OK FOR SERVICE.Jun 4, 2025 · N489HA · Boeing 717200SDR SCNA20250605198Coffeemaker · contaminatedCOFFEE HAS WEIRD/TOXIC/METALLIC TASTE. SERVICED H2O RAN FLUSHED COFFEE MAKER WATER NOW TASTE IS IK. REF 12-14-01 REV 86Jun 4, 2025 · N804SY · Boeing 7378SDR VNAA202508030010Fitting · corrodedCORROSION ON FITTING (1EA) OF ACCESS 104 AT GALLEY 1. FITTING (1EA) OF ACCESS 104 AT GALLEY 1 WAS REPLACED PER SAFRAN CMM 25-32-02.Jun 3, 2025 · N637NN · Cndair CL6002D24SDR CALA2025060505283Oven · dirtyFA REPORTS BURNING SMELL IN AFT GALLEY. UNABLE TO LOCATE SOURCE CLEANED GALLEY OVEN 425 FROM FOOD SPILL. OPS CHECK GOOD, NO MORE ODOR/SMELL.Jun 3, 2025 · N13750 · Boeing 737724SDR SCNA20250603187Oven · smokeAFT OVEN A/C LEFT SMOKES, NEEDS TO BE CLEANED ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) ) - RESOLUTION: CLEANED AFT GALLEY OVEN #3 OPS CHECK GOOD REF AMM 25-31-01. THIS CLEARS MEL 25-10 MDDR# 131761Jun 3, 2025 · N836SY · Boeing 7378KNSDR VNAA202508030012Fitting · corrodedCORROSION ON FITTINGS OF ACCESS 407 (1 EA) AT GALLEY 4. FITTING OF ACCESS 407 (1 EA) AT GALLEY 4 WAS REPLACED PER CMM 25-32-99.Jun 2, 2025 · N637NN · Cndair CL6002D24SDR VNAA202508030011Fitting · corrodedCORROSION ON FITTINGS OF ACCESS 306 (1EA) AND 307 (2EAS) AT GALLEY 3. FLOORS FITTINGS WITH P/N CDSP2019-7C-650 AND P/N CDSP2019-7C-700 OF ACCESS 306 (1EA) AND 307 (2EAS) AT GALLEY 3 WERE REPLACED PER CMM 25-33-13.Jun 2, 2025 · N637NN · Cndair CL6002D24SDR CALA2025060405262Oven · odorELECTRIC SMOKE SMELL MID GALLEY OVENS INOP PERFORMED OPS CHECK OF MID GALLEY OVENS NO BURNING SMELL/FAULTS NOTED. SMELLY OVENS CORRECTION CAN BE FOUND ON LP 5055964. OVEN OPS CHECK REF MM TASK 25-32-02-700-801-004.Jun 2, 2025 · N27015 · Boeing 777224SDR CALA2025060405260Tray · odorSMELL OF POSSIBLE ELECTRICAL SMOKE FRM FWD GALLEY OVENS UPON TBS FOUND CHOCOLATE AND CARMEL ON OVEN CATERING TRAY GENERATING BURNING SMELL WHEN OVEN IS OPERATING. NOTIFIED CATERING FOR NEW TRAYS. NO FAULTS NOTED WHEN OVENS OPERATING REF MM TASK 25-32-02-700-80Jun 2, 2025 · N27015 · Boeing 777224SDR CALA2025060405259Control Unit · faultedDURING INSPECTION FOR ODOR IN THE CABIN FOUND AFT GALLEY G6 NOT POWERED. CYCLING AFT RH GALLEY BREAKER ON THE P11 PANEL U34 RESTORED G6 POWER. NOTICED ODOR COMING FROM G6 A FEW MINUTES LATER. INSPECTED WIRING BEHIND COFFEE MAKERS,CIRCUIT BREAKER PANEL AND CHILJun 2, 2025 · N665UA · Boeing 767322SDR SCNA20250603189Oven · dirtyAFT OVEN A/C LEFT SMOKES, NEEDS TO BE CLEANED ( NON-ESSENTIAL EQUIPMENT AND FURNISHING. CLEANED AFT GALLEY OVEN #3 OPS CHECK GOOD REF AMM 25-31-01. THIS CLEARS MEL 25-10 MDDR# 131761Jun 2, 2025 · N805SY · Boeing 7378Q8SDR SWIA20250602030Oven · smokeINFLIGHT FORWARD FA REPORTED SMOKE COMING FROM FORWARD GALLEY OVEN. SMOKE DISSIPATED AFTER OVEN WAS TURNED OFF. SMOKE WAS WHITE AND HAD ELECTRICAL SMELL TO IT. OVEN REMAINED OFF FOR REST OF FLIGHT WITH NO FURTHER ISSUE. (FLIGHT 3426 - FILED CLOSED)MAY 30, 2025May 30, 2025 · N181SY · Emb ERJ170200LRSDR AALA202506028860Oven · shortedAIRCRAFT WAS NOT GROUNDED: OVEN NUMBER 1 HAS WEIRD SMELL POSSIBLE BURNING ELECTRICAL VERIFIED FORWARD GALLEY OVEN NUMBER 1 FAULTY. REMOVED AND REPLACED FORWARD GALLEY OVEN NUMBER 1. PER AMM 25-32-03. OPERTIONAL CHECK GOOD.May 30, 2025 · N857NN · Boeing 737823SDR SWIA20250530001Oven · smokeINFLIGHT FORWARD FA REPORTED SMOKE COMING FROM FORWARD GALLEY OVEN. SMOKE DISSIPATED AFTER OVEN WAS TURNED OFF. SMOKE WAS WHITE AND HAD ELECTRICAL SMELL TO IT. OVEN REMAINED OFF FOR REST OF FLIGHT WITH NO FURTHER ISSUE.C: NEF-GAL-7; MX ACTIONS COMPLIED WITHCATMay 30, 2025 · N181SY · Emb ERJ170200LRSDR CALA2025053005116Oven · faultedFWD GALLEY OVEN2 GOT VERY HOT HAD BAD BURNING SMELL THAT WAS HOT TER THAN OVEN1 UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC METER INITIATED FOR WITH VENDOR ID V951670 MAC RELATED WORK ORDER 0000000031382May 28, 2025 · N35271 · Boeing 737824SDR YENA2025052800545Coffeemaker · odorFLT#1520, ATL-JFK. 'FLIGHT ATTENDANTS REPORTED MOMENTARY BURNING SMELL IN AREA AROUND COFFEE POTS. AFT GALLEY; C/W INFO NOTICE 2017-T015 SECTION A. FOUND COFFEE MARKS 404 & 405 HAS BURNT SMELL, REF LP 4336567, ITEM 1 (REMOVED AND REPLACED 405 COFFEE MAKER IAW May 27, 2025 · N630JB · Airbus A320232SDR CALA2025053005115Chiller · faultedELECTRICAL SMELL IN AFT GALLEY. DISCUSSED AFT GALLEY BURNING SMELL WITH FIGHT ATTENDANT IN AFT GALLEY. UPON ARRIVAL OF MX TO AIRCRAFT SMELL WAS NO LONGER PRESENT. ATTEMPTED TO RECREATE SMELL NO SMELL NOTED. FLIGHT ATTENDANT NOTED THAT SMELL APPEARED AFTER CHILMay 25, 2025 · N482UA · Airbus A320232SDR AALA202505288321Oven · smokeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTANDENTS REPORTS RIGHT HAND OVEN HAS A BURNING RUBBER SMELL AND SOME SMOKE WHEN TURNED ON. REMOVED AND REPLACED FORWARD GALLEY RIGHT OVEN. PER AMM 25-32-02. OPERTIONAL CHECK GOOD.May 24, 2025 · N942AN · Boeing 737823SDR AALA202505262694Coffeemaker · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORTED A BURNING ELECTRICAL SMELL IN THE FORWARD GALLEY. NO VISIBLE INDICATIONS. OCCURRED SHORTLY AFTER REACHING CRUISE ALTITUDE (FL290) AND STARTED TO DISSIPATE JUST BEFORE DESCENT. TOTALLY CLEAR PASSING 15,000 FEMay 24, 2025 · N447AN · Airbus A321253NXSDR AALA202505269978Coffeemaker · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORTED A BURNING ELECTRICAL SMELL IN THE FORWARD GALLEY. NO VISIBLE INDICATIONS. OCCURRED SHORTLY AFTER REACHING CRUISE ALTITUDE (FL290) AND STARTED TO DISSIPATE JUST BEFORE DESCENT. TOTALLY CLEAR PASSING 15,000 FEMay 24, 2025 · N447AN · Airbus A321253NXSDR DALA2025052704091Oven · odor(LOG 7053205) FAS REPORTED A STRONG BURNING RUBBER SMELL FOR APPROX 10 MIN. T/S AND FND F/C GALLEY OVEN DIRTY AND HEATING IMPROPERLY. R/R F/C GALLEY OVEN ASSY PER B737 AMM 25-31 AND ALL OPS NML.May 23, 2025 · N861DN · Boeing 737932ERSDR AALA202505261256Oven · odorAIRCRAFT WAS NOT GROUNDED: NUMBER 1 OVEN NEEDS TO BE REPLACED DUE TO PUNGENT BURNED PLASTIC SMELL WHEN UTILIZED. MULTIPLE PASSENGERS COMPLAINED. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO ODORS NOTEDMay 20, 2025 · N153UW · Airbus A321211SDR CALA2025052004850Coffeemaker · sparksALL AFT GALLEY COFFEE POTS SPARKING CB PULLED TO REMOVE POWER LOCKING TO VERIFY GMM 05-30-05 WAS COMPLIED WITH. FLIGHT ATT STATED SAW COFFEE MAKERS SPARK IN SEQUENCE AT EACH COFFE MAKER 1 TIME THEN PULLED BREAKERS PULLED ALL AFT GALLEY COFFE MAKERS OUT,NO HEAMay 17, 2025 · N212UA · Boeing 777222SDR CALA2025051904756Chiller · faultedPLASTIC BURNING SMELL AT MID GALLEY. STOPPED USING OVENS AND COF EE DEBRIEFED FLT ATTD AND NOTED SOURCE OF SMELL APPEARS TO COME FRO M CHILLER DUE GRINDING BEARING NOISE. OPERATED OVENS AND CMS AND FOUND SERVICEABLE. DE-ACTIVATED C31 CHILLER CB PER MEL AND INSMay 13, 2025 · N211UA · Boeing 777222SDR DALA2025051603793Oven · odorSHIP 3258 DISC: FLT ATTN REPORTED OVEN SMELLED LIKE BURNING PLASTIC WENT AWAY WHEN TURNED OFF. C/A: FLT ATTENDENT STATED SHE SMELLED BURNING PLASTIC WHEN OVEN WAS RUNNING AFTER TURNED OFF NO SMELL. PERFORMED OPS TEST OF OVEN FOR 10 MINS FULL HEAT NO BURNING SMMay 12, 2025 · N358NW · Airbus A320212SDR CALA2025051204607Unknown · smokeAFTER TO FA SAID STEAM/SMOKE OUT OF 2L GALLEY DRAIN.AREA HOT TO TOUCH. ACCOMPLISHED INSPECTION IAW AMM 05-51-99-99A-282A-A. NO FINDING OF ELECTRICAL SHORT, SMOKE, FUMES OR IRREGULAR HIGH HEAT FOR ALL GALLEY EQUIPMENT, CEILING LIGHTS AND CEILING ELEC COMPONENTSMay 11, 2025 · N13018 · Boeing 78710
Back to JASC 2530