SDR AALA202302165838Oven · smokeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT OVEN SMOKING. **SUPPLEMENTAL REPORT FOR AALA202301305838: MAINTENANCE REPLACED OVEN PER AMM 25-32-03 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.** (CLOSED)SDR AALA202301305838Oven · smokeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT OVEN SMOKING. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202301208187Oven · odorAIRCRAFT WAS GROUNDED: ONE HOUR INTO THE FLIGHT A SLIGHT ACRID SMELL IN FLIGHT DECK AT FL370. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE FORWARD GALLEY OVENS. REPLACED THE FORWARD GALLEY #1 OVEN (AALA202301201664) AND #2 OVEN (AALA202301208187) PER AMMSDR AALA202301201664Oven · odorAIRCRAFT WAS GROUNDED: ONE HOUR INTO THE FLIGHT A SLIGHT ACRID SMELL IN FLIGHT DECK AT FL370. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE FORWARD GALLEY OVENS. REPLACED THE FORWARD GALLEY #1 OVEN (AALA202301201664) AND #2 OVEN (AALA202301208187) PER AMMSDR SWAA2023020291572Light · brokenBROKEN GALLEY 1 EMERGENCY EXIT LIGHT ASSY AT FWD GALLEY AREA 2023-36567<[01] REPLACED ON GALLEY 1 EMERGENCY EXIT LIGHT ASSY AT FWD GALLEY AREA IAW B737-900 AMM 33-51-01-960-802;[02] CORRECTED STEP 1 REPLACED ON GALLEY 1 EMERGENCY EXIT LIGHT ASSY AT FWD GALLEY SDR DALA2023011300290Oven · fod(LOG 2579651) CREW NOTICED BURNING RUBBER SMELL COMING FROM OVEN. OUND ON GRILL AT BACK OF OVEN OVER FAN HAS MELTED PLASTIC FUSED TO OPENINGS. REMOVED AND REPLACED FWD GALLEY OVEN REF B737 AMM 25-31. OPS CHECKS OK.SDR AALA202301095109Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED THE FORWARD GALLEY OVEN ON LEFT SIDE PRODUCES STRONG BURNTPLASTIC SMELL WHEN USED. MAINTENANCE REPLACED THE OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202301069220Oven · smokeAIRCRAFT WAS NOT GROUNDED: NUMBER 1 OVEN IN FORWARD GALLEY MISSING BACK FAN COVER AND SMOKES EXCESSIVELY WHEN TURNED ON. REPLACED NUMBER 1 OVEN IAW AMM 25-32-03.SDR AALA202301125174Coffeemaker · odorAIRCRAFT WAS GROUNDED: DURING DESCENT FLIGHT ATTENDANTS REPORTED A MELTING PLASTIC SMELL FROM AFT GALLEY. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE AFT GALLEY COFFEE MAKERS. AFT LEFT COFFEE MAKER AND THE AFT RIGHT COFFEE MAKER (AALA202301122638) PERSDR AALA202301122638Coffeemaker · odorAIRCRAFT WAS GROUNDED: DURING DESCENT FLIGHT ATTENDANTS REPORTED A MELTING PLASTIC SMELL FROM AFT GALLEY. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE AFT GALLEY COFFEE MAKERS. AFT LEFT COFFEE MAKER AND THE AFT RIGHT COFFEE MAKER PER AMM 25-35-15.SDR AALA202212285174Coffeemaker · odorAIRCRAFT WAS GROUNDED: FDURING DESCENT FLIGHT ATTENDANTS REPORTED A MELTING PLASTIC SMELL FROM AFT GALLEY. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE AFT GALLEY COFFEE MAKERS. (OPEN)SDR ASAA2022122641235Oven · failedFA REPORTS ON FINAL LEFT REAR OVEN EMITTING SMOKE AND BURNING SMELL FA ALSO SAW SPARKS INSIDE OVEN . OVEN WAS POWERED OFF. GROUNDED - YES. REMOVED AND REPLACED AFT GALLEY OVEN REF B737-900 AMM 25-32-01. OPS CHECK GOOD.SDR AALA202212271664Oven · smokeAIRCRAFT WAS NOT GROUNDED: #2 OVEN IN FORWARD GALLEY SMOKES AFTER BEING ON FOR 5 MINUTES. REPLACED OVEN PER TASK 25-35-19-000-001 AND 25-35-19-400-001. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK..SDR AALA202212221664Oven · smokeAIRCRAFT WAS NOT GROUNDED: #2 OVEN IN FORWARD GALLEY SMOKES AFTER BEING ON FOR 5 MINUTES. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202212216462Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 GALLEY HAS PLASTIC ODOR WHEN IN USE. REPLACED OVEN PER AMM 25-32-03.SDR AALA202301044057Chiller · vibrationAIRCRAFT WAS GROUNDED, INFLT DECK, VIBRATION FELT INTERMITTENTLY STARTING ABOUT 8000'. RETRACTED LANDING LIGHTS BUT VIBRATION CONTINUED WITH ENGINE 1 N1 VIB 1.6 AND DOOR INDICATIONS NORMAL. AT ALT 16500, F/A CALLED TO SAY R1 DOOR VIBRATING. EMERGENCY DECLARSDR AALA202212204057Chiller · vibratesAIRCRAFT WAS GROUNDED: IN FLIGHT DECK, VIBRATION FELT INTERMITTENTLY STARTING ABOUT 8000'. CREW RETRACTED LANDING LIGHTS BUT VIBRATION CONTINUED WITH ENGINE 1 N1 VIB 1.6 AND DOOR INDICATIONS NORMAL. AT ALT 16500 #1 FLIGHT ATTENDANT CALLED TO SAY 1R DOOR VIBRATSDR CALA2022121603409Oven · smokeOVEN/WARMERSMOKING OR SPARKING 706 AFT GALLEY OVEN 706 REPORTED TO BE SMOKING WHEN TURNED ON. VERBAL REPORTED,SMOKE FROM OVEN INSIDE ONLY.CHKD OVEN 706,FOUND INOP WITH 'CRITICAL ERROR' MSG.PULLED AND COLLARED CB.REQUEST AUTH FOR OVEN 706 INOP IN AFT GALLEY PERSDR AALA202212192187Oven · smokeAIRCRAFT WAS NOT GROUNDED: LEFT OVEN SMOKING AND SMELLS LIKE BURNING PLASTIC. REMOVED AND REPLACED LEFT OVEN PER AMM 25-32-03-000-801.SDR DALA2022121508145Warmer · odorBUN WARMER HAS A BURNING ELECTRICS ODOR WHEN IN USE LOC M2 404. R & R BUN WARMER IN MID GALLEY.SDR KCSA2022121528Capacitor · blownLOUD NOISE OBSERVED FRM OVEN WHEN OPERATING IT FOLLOWED BY UNUSUAL SMELL, WHICH DISSIPATED IMMEDIATELY. UTILITY L/R OFF AS A PRECAUTION. TROUBLESHOT IN ACCORDANCE WITH FIM 21-00 TASK 810 DISCOVERED BLOWN CAPACITOR ON OVEN CONTROL UNIT SEE LOGPAGE 100121176, ITSDR AALA202212129819Oven · smokeAIRCRAFT WAS GROUNDED: RIGHT FORWARD GALLEY OVEN ARCING AND SMOKING. OVEN TURNED OFF, SMOKING STOPPED. REPLACED OVEN PER AMM 25-32-03.SDR DALA2022122208304Oven · odorOVEN PRODUCES A BURING RUBBER SMELL. REPLACED OVEN.SDR DALA2022120907956Warmer · fodMID GALLEY BUN WARMER. CONFIRMED BURNT PLASTIC BY FLIGHT CREW. CORRECTIVE ACTION: BE ADVISED THAT A BUN WARMER AND AN OVEN IS NOT THE SAME THING. AFTER PERFORMING OPERATIONAL CHECK OF BUN WARMER, THE UNIT WORKS NORMALLY. THE BUN WARMER HAS 2 MODES WHICH ARE HISDR DALA2022120507794Coffeemaker · smokeFA REPORTS AFT COFFEE MAKER EMITTING SMOKE AND AN ELECTRICAL ODOR. R & R COFFEE MAKER NR 3 IAW AMM 25-31. OPS CHECKED GOOD AND NO BURNING ODOR. C/W ODI CHK LIST AND WORKCARD 0550-9001-B757 AND INSPECTED COFFEE MAKER WIRING, IFE EQUIP, LIGHTS, BALLASTS, PSU, GSDR AALA202212050235Oven · odorAIRCRAFT WAS NOT GROUNDED: #2 OVEN IN FORWARD GALLEY SMOKES WHEN IN USE. REPLACED OVEN PER AMM 25-32-03.SDR DALA2023041202884Unknown · unknown(LOG 2516803) ACCOMPLISHED VA 97742 FOR GALLEY MODIFICATIONS TO COVERT LION AIR TO DELTA STANDARDS IN CONJUNCTION WITH AA 2530-01593.SDR DALA2023030601632None · none(LOG 2516820) PERFORM VA 97742 TO MODIFY PRE LION AIR GALLEY CONFIGURATION TO DELTA STANDARDS.SDR DALA2023030601631None · none(LOG 2516808) PERFORM VA 97742 TO MODIFY PRE LION AIR GALLEY CONFIGURATION TO DELTA STANDARDS.SDR DALA2023022401399None · none(LOG 2516817) MAINTENANCE PERFORMED MAJOR ALTERATION TO THE GALLEYS PER VA 97742.SDR AALA202211289214Oven · odorAIRCRAFT WAS GROUNDED: RIGHT OVEN IN FORWARD GALLEY HAS ELECTRICAL ODOR WHEN TURNED ON. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO ODORS NOTED.SDR AALA202211284651Oven · smokeAIRCRAFT WAS NOT GROUNDED: BUISNESS CLASS G4 GALLEY OVEN 3 NEEDS CLEANING. OVEN SMOKES WHEN HEATING. MAINTENANCE REPLACED OVEN3 PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202211218645Coffeemaker · odorAIRCRAFT WAS GROUNDED: ODOR COMING FROM FORWARD GALLEY. FLIGHT RETURNED TO LAX LANDING SAFELY. MAINTENANCE FOUND ODOR COMING FROM FORWARD GALLEY COFFEE MAKER CM4. REPLACED ESPRESSO / COFFEE MAKER PER AMM 25-33-28.SDR DALA2023022401402None · none(LOG 2500769) MAINTENANCE PERFORMED MAJOR ALTERATION TO THE GALLEYS PER VA 97741.SDR AALA202211178343Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFT GALLEY CHILLER MALFUNCTION LIGHT ILLUMINATED ALONG WITH A BURNING SMELL CHILLER WAS SWITCHED OFF AND SMELL STOP. AFT GALLEY CHILLER WAS FOUND TO BE THE SOURCE OF THE SMELL. SMELL STOPPED AFTER THE OVEN WAS TURNED OFF. REMOVED ANDSDR AALA202211104452Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDENTS REPORT UNUSUAL STRONG ODOR COMING FROM COFFEE POTT. MAINTENANCE REPALCED RIGHT HAND AFT COFFEE MAKER PER AMM 25-10-00.SDR QXEA2022110900317Coffeemaker · smokeAFT INBOARD COFFEE MAKER POWER BUTTON FLASHING AND VISIBLE SMOKE AND ELECTRICAL SMELL. REMOVED FROM SERVICE. REMOVED AND REPLACED AFT INBOARD COFFEE MAKER IAW AMM TASK 25-37-03-000-801-A/400-801-A. OPS CHECK GOOD, CLEAR DEFECT. RETURNED TO SERVICE.SDR DALA2022103107031Oven · odor(LOG 9576054) AFTER INITIAL (TOD) FA NOTICED ELECTRICAL BURTNING SMELL IN FORWARD GALLEY. NO HEAT. NO FIRE. NO SMOKE. T/S PER B737 FIM TASK 21-00-00-810-806. NO OTHER TROUBLE FOUND. R/R FWD GALLEY OVEN REF B737 AMM 21-31. AIR RECIRC FILTERS REPLACED PER B737 ASDR AALA202210251708Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS LEFT OVEN HAS ACRID ODOR WHEN IN OPERATION. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202210254329Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED SMELL OF POPCORN IN AFT GALLERY DURING LANDING. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED SAFLEY WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND HOT PLATE ON AND BURNED COFFEE ON HOT PLATE AND UNDER COSDR AALA202210191516Oven · smokeAIRCRAFT WAS NOT GROUNDED: NUMBER 1 OVEN IN FIRST CLASS GALLEY SMOKED WHEN TURNED ON FLIGHT ATTENDANT REPORTS FOUND REMNANTS POSSIBLE CAUSE. REMOVED AND REPLACED NUMBER 1 OVEN PER AMM 25-32-03.SDR DALA2022101706703Oven · contaminatedSHIP 1820 BURNT PLASTIC, MELTED PLASTIC HARDENED INTO BOTTOM OF THE BUN OVEN, CORRECTIVE ACTION: REMOVED DEBRIS FROM BUN OVEN, OK FOR SVC (9704975)SDR AALA202210179692Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN # 2 HAS BURNING ODOR. REPLACED OVEN PER AMM 25-32-03. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR DALA2022101806737None · noneSHIP 3318 COFFEE MAKER 1 RIGHT MID GALLEY LEAKS. CORRECTIVE ACTION: SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0002:3810-9202/003 00464 REPLACED COFFEE MAKER REF A330 AMM 25-35. (2451982)SDR SCNA20221011127Oven · smokeDEFECT 725184: OVEN SMOKING WHILE COOKING SMELLS ELECTRICAL. RESOLUTION: CATERING REPLACED OVEN RACKS AND INSERT WITH CLEAN UNITS OPS CHECK GOOD IAW AMM 25-30-61 NO ELECTRIC SMELL NOTED.SDR AALA202210052287Chiller · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL FLIGHT ATTENDANT REPORTED ACRID , PUNGENT ANTI FREEZE SMELL THAT LASTED 2 TO 3 MINUTES THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DETERMINED THE SOURCE OF THE ODOR WAS THE CHILLER. **SUPSDR AALA202210042287Chiller · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL FLIGHT ATTENDANT REPORTED ACRID , PUNGENT ANTI FREEZE SMELL THAT LASTED 2 TO 3 MINUTES THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DETERMINED THE SOURCE OF THE ODOR WAS THE CHILLER. **SUPSDR AALA202209280648Oven · fireAIRCRAFT WAS NOT GROUNDED: FIRST CLASS OVEN REQUIRES CLEANING. HALON FIRE BOTTLE USED TO PUT OUT FIRE. REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-33-00.SDR F3LA2022092600122Coffeemaker · failedFA REPORTED BURNING WIRE SMELL IN FWD LAV ON DESCENT. - CORRECTION ACTION: FOUND FWD COFFEE MAKER CAUSING BURNING SMELL. PLACED ON NEF 25-99-40 AD CN#1186814. PLACARDS INSTALLED WITH MCC ABM 430781N REFERENCE TSM 05-50-00-810-831-A AC OK FOR SERVICE.SDR SWAA2022092283383None · smokeFLIGHT ATTENDANT REPORTED SMOKE AFT GALLEY CEILING NEAR SERVICE DOOR. DISSIPATED AFTER 15 SECONDS. / [01] PERFORMED SMOKE AND FUME IN CABIN CONDITIONAL INSPECTION PER AMM 05-51-56 AND FIM 21-00 TASK 806. REPLACED AFT #2 COFFEE MAKER PER AMM 25-30-01. PERFORMED
Back to JASC 2530