Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2018010800099Oven · failedGALLEY OVEN INOPERATIVE AT R2 DOOR, CIRCUIT BREAKER R41 TRIPPED, A BURNING ODOR NOTICED ODOR DISSIPATED. RESET THE CIRCUIT BREAKER IAW AMM 20-16-11 AND OPS CHECKED THE OVEN. NO ODOR PRESENT AND OPS CHECKED NORMAL.SDR CALA2018010800096Oven · smokeAFT GALLEY OVENS SECURED DUE TO SMOKE FROM TOP OUTSIDE OF 411. 412/13. REMOVED AND REPLACED THE AFT GALLEY OVEN IAW AMM 25-34-00. OPS CHECKED GOODSDR AALA201801089036Oven · fireOVEN FIRE IN 1ST CLASS GALLEY, FIRE EXTINGUISHED WITHOUT FIRE EXTINGUSHER. REMOVED AND REPLACED THE OVEN. OPS CHECKED. OK FOR SERIVICE.SDR AALA201801049007Warmer · odorAIRCRAFT WAS NOT GROUNDED: WARMER OVEN COMPARTMENT ONE SMOKES WHEN TURNED ON AND SMELLS LIKE BURNT PLASTIC. MAINTENANCE SCHEDULED TO REPLACE BUN WARMER AS NEEDED. ***SUPPLEMENTAL TO UPDATE SECTION 4. MAINTENANCE REPLACED BUN WARMER OF COMPARTMENT ONE (FORWARD SDR REXA2018010200004Oven · smokeFA REPORTED THE GALLEY OVEN WAS SMOKING WHILE HEATING MEALS. PERFORMED AN OPS CHECK OF OVEN IAW AMM 25-32-01. NO DEFECTS NOTED.SDR DALA2018010300049Oven · smokeREPORTED SMOKE AND FUMES FROM FORWARD GALLEY OVEN DURING TAXI OUT. REPLACED THE OVEN.SDR CALA2017122504594Controller · failedOVENS NR 1 AND 2 IN 1ST CLASS BOTH OVERHEAT WITH ASSOCIATED ELECTRICAL WIRE ODOR. REMOVED AND REPLACED THE OVEN TEMP CONTROLLERS. RAN BOTH OVENS FOR 10 MINUTES ON HIGH, NO METALLIC ODORS NOTED.SDR CALA2017122604608Fan · failedSMOKE IN CABIN. EMERGENCY DECLARED. FOUND THE FWD CHILLER FAN FAILED, CAUSING SMOKE ODOR IN THE CABIN. THE FWD GALLEY CHILLER HAD NO OUTPUT. REMOVED AND REPLACE THE FWD GALLEY CHILLER IAW AMM 25-33-01. THE CHILLER OPS CHECKED GOOD IAW AMM 25-33-01-706-004.SDR AALA201712229014Oven · odorEMERGENCY DECLARED, DIVERTED DUE TO ELECTRICAL ODOR IN AFT GALLEY. OVEN OVERTEMPERATURE ACCOMPANIED BY SMOKE/FUMES (ACRID SMELL) WITH ELECTRICAL SMELL 6-11. OVER TIME, SMELL WENT AWAY. AIRCRAFT LANDED OVERWEIGHT WITHOUT INCIDENT. MAINTENANCE PERFORMED OVERWEISDR CALA2017122104558Oven · odorAFT OVEN 412 MAKING BURNIG PLASTIC ODOR. ODOR STOPPED WHEN TURNED OFF. REMOVED AND REPLACED OVEN AT POSTION 412, IAW AMM 25-34-00. OPS CHECKED GOOD.SDR CALA2017121904524Oven · smokeOVEN SMOKING OR SPARKING 204 OVEN NR 1 PSN 204 SMOKES AND SMELLS OF BURNT FOOD ODOR DISSIPATES WHEN TURNED OFF. REMOVED AND REPLACED OVEN AT POSITION 204 OPS CHECK.SDR CALA2017121904533Coffeemaker · odorAFT GALLEY SMELL OF BURNING PLASTIC. AFT RIGHT CHILLER TURNED OFF AND SMELL CEASED. REMOVED AND REPLACED M42 COFFEE MAKER. NO SMELL NOTED. NO LEAKS NOTED. OPS CHECK GOOD.SDR CALA2017121704485Oven · dirtyAFT OVEN 3 NEEDS TO BE CLEANED SMOKES AFT OVEN 3 IS CLEANED AND OPS CHECKED GOOD. OK TO CONTINUESDR CALA2017121604471Oven · sparksOVEN SMOKING OR SPARKING 205 REMOVED OVEN CONTENTS. FOUND RESIDUAL FROM PREVIOUS FLT. CLEANED AND OPS CHK''D OVEN. OK TO CONTINUE. OPS CHKS NORMAL.SDR CALA2017121604476Oven · smokeFWD GALLEY OVEN 1 HAS MOTOR NOISE AND SMOKE. C/B PULLED. RPL FWD GALLEY OVEN #204 PER AMM 25-34-00-400-801C3. OPS CKS OKSDR CALA2017121604472Oven · smokeFWD GALLEY OVEN 106 SMOKING BADLY. REPLACED THE OVEN.SDR CALA2017121304417Oven · odorELECTRICAL SMELL FROM F/C OVEN NUMBER 105. REPLACED OVEN AT LOC 105 PER AMM 25-35-19. OPS CHECK GOOD.SDR SWAA2017121318432Coffeemaker · faultyDIVERSION/DECLARED EMERGENCY, FLIGHT ATTENDANTS REPORTED A STRONG "TOXIC CHEMICAL" SMELL COMING FROM THE AFT GALLEY COFFEE POT AREA. R&R NR 1 COFFEEMAKER IAW AMM.SDR SWAA2017121318431Coffeemaker · faultyDIVERSION/DECLARED EMERGENCY, FLIGHT ATTENDANTS REPORTED A STRONG "TOXIC CHEMICAL" SMELL COMING FROM THE AFT GALLEY COFFEE POT AREA. R&R NR 2 COFFEEMAKER IAW AMM.SDR CALA2017121104387Oven · smokeOVEN 409 HAD EXCESSIVE SMOKE WHEN BEING USED. REPLACED THE OVEN IAW MM 25-31-00.SDR CALA2017121104386Oven · smokeOVEN 411 AT POS 5 INOP OVEN WAS SMOKING THEN SHUT ITSELF OFF. R/R OVEN AT 411 POS 5SDR CALA2017120804332Coffeemaker · odorCOFFEE MAKER M42 AFT GALLEY HAS A BURNING PLASTIC SMELL. REMOVED AND CLEANED PLASTIC FROM HOT PLATE ON COFFEE MAKER M42 OPS CHECKS NORMALSDR CALA2017120804330Oven · smokeOVEN SMOKING OR SPARKING 205 SMOKE FROM OVEN WHEN ACTIVATED. FA REPORT INSIDE CLEAN REMOVED AND REPLACED OVEN AS REQUIRED C/B RESET POS 205 OK TO CONTSDR CALA2017120804329Oven · smokeAFT LAV SMOKE EICAS. ISOLATED TO OVEN WHEN LAV DOOR WAS OPENED. REPLACED FAULTY OVEN AT POS 413 IN AFT GALLEY. OPERATIONAL CHECK OK.SDR AALA201712079017Fan · dirtyAIRCRAFT NOT GROUNDED. FORWARD GALLEY OVEN VERY HOT. OVEN VENT NEEDS CLEANED OFF BURNT TINFOIL. CLEANED DEBRIS FROM OVEN FAN PER AMM 25-35-19.SDR CALA2017120404315Oven · odorF/A REPORT BURNING SMELL IN AFT GALLEY OVENS OFF INSPECTED OVENS AND COFFE MAKERS , COULD NOT PERCIEV SAME WRITTEN SMELL,EXTRACTER BLOWERS WORKING FINE A/C OK TO CONTINUE.SDR CALA2017120304296Chiller · malfunctionedCHILLER 6.7.8 PLASTIC SMELL WHEN ON. REPLACED AFT CHILLER 6 OPS CK NORMAL REF IPC 25-33-03-11 NO EXISTING SMELL AROUND GALLEY AREA OK TO CONTINUE.SDR CALA2017112204187Oven · odorFA REPORTED THE OVEN R12 HAD ELECTRICAL ODOR. REPLACED THE OVEN IAW AMM 25-35-19-401. OPS CHECKED GOOD. OK TO CONTINUE.SDR CALA2017111904146Unknown · odorOVEN HAD A BURNED RUBBER ODOR AT THE AFT GALLEY G4B. OVEN 423 OR 424 NOT SURE WHICH ONE HAS BURNED RUBBER ODOR CLEANED OVENSDR CALA2017111704097Oven · smokeOVEN 110 FWD GALLEY BEGAN SMOKING. REPLACED THE OVEN. OPS CHECKED NORMAL. NO DEFECTS NOTED.SDR AALA201711169021Warmer · odorTHE AIRCRAFT WAS NOT GROUNDED. OVEN WARMER #2 HAS ELECTRICAL ODOR. REMOVED AND REPLACED OVEN-BUN WARMER IN THE FORWARD GALLEY PER AMM 25-32-02. OPERATIONAL CHECK GOOD.SDR CALA2017111104022Oven · smokeNR 2 OVEN SMOKED AND SMELLED LIKE AN ELECTRICAL PROBLEM . REPLACED THE OVEN IAW 25-34-00. OPS CHECKED GOOD,SDR CALA2017111003988Oven · overheatedOVEN IN MID GALLEY OVERHEATED, SMELLS OF SOMETHING BURNING ALSO ADJACENT WALL IS BURNED. REMOVED AND REPLACED THE OVEN IAW AMM 25-32-98. OPS CHECKED OK.SDR AALA201711099021Seal · leakingON CLIMB OUT AT 19,000 FT, CABIN PRESSURE WENT ABOVE 10,000 FT. EMERGENCY DECLARED. REPLACED THE FORWARD CARGO DOOR SEAL, ACCOMPLISHED PRESSURIZATION CHECK IAW AMM. OPS CHECKED NORMAL. AIRCRAFT GROUNDED.SDR CALA2017110303906Oven · smokeCREW REPORTS OVEN 204 EMITTING SMOKE. TURNED OFF AND DEACTIVATED.. SUSPECT GREASE ON FAN CAUSING SMOKE. R&R OVEN 204 IAW AMM 25-32-00. OPS CHK GOOD.SDR CALA2017110303903Oven · odorAFT GALLEY OVEN 425 SMELLS OF ELECTRIC BURN NO SMELL WHEN OFF. REPLACED OVEN AND OPS CHECKED. NO ELECTRICAL BURNING SMELL. OK TO CONTINUE ON WITH NEW OVEN INSTALLED.SDR VNAA2017103011101Heater · odorBURNING ODOR IN THE FORWARD CABIN AND FLIGHT DECK AREAS. MAINTENANCE INSPECTED AND FOUND THE ODOR TO BE COMING FROM GALLEY HEATER.SDR AALA201710279010Chiller · odorFWD GALLEY CHILLER EMITTED AN UNACCEPTABLE ODOR. REMOVED AND REPLACED IAW AMM.SDR DALA2017102607792Bracket · corrodedDURING INSPECTION FOUND CORROSION ON BRACKETS (17 EAS) OF GALLEY NR 4. MAINTENANCE REPLACED 2 BRACKETS (17EA) OF GALLEY NR 4 WERE REPLACED PER ERA 560951-14 REV ORIG AND ETI-37-17-315 REV 1.SDR CALA2017102203733Oven · odorOVEN 205 IS PRODUCING AN ACRID ODOR WHEN USED. NOT BURNED FOOD OVEN 205 OPS TEST DURING A FEW MINUTES FOUND ALL SERVICEABLESDR ASOA201710225165Coffeemaker · smokeBOTH COFFEEMAKERS EMITTED SMOKE DURING FLIGHT. REMOVED AND REPLACED THE COFFEEMAKERS. OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR 2WAA2017101900001Oven · odorWIRE BURNING ODOR AT 12000 FT, SMOKE IN FWD CABIN. TURNED OFF MASTER GALLEY POWER SWITCH, SMOKE DISSIPATED. PERFORMED A VISUAL INSPECTION AND EWIS ON MASTER GALLEY POWER SWITCH AND SURROUNDING CIRCUITRY AT OVER HEAD PANEL, AND ON EPC PANEL AND GALLEY WIRING ISDR CALA2017101303589Oven · sparksOVEN SMOKING OR SPARKING. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00. OPS CHECKED GOOD.SDR CALA2017101303588Oven · smokeOVEN 109 IN THE FORWARD GALLEY HAD SMOKE AND A BURNING ODOR DURING FLT. REMOVED AND REPLACED OVEN, OPS CHECKED NORMAL IAW AMM 25-34-00.SDR DXTA20171012544Coffeemaker · odorSMOKE ODOR IN THE COCKPIT, DESCENDING THROUGH 14,000 FT AND DISSIPATED AROUND 4,000 FT. NOTICEABLE SOOTING AT LEFT AND RIGHT GENERATORS. AIRCRAFT DEPARTED DURING THESE FIRE EVENTS. INSPECTED ENTIRE AIRCRAFT FOR SMOKE ODOR IN FLIGHT DECK & CABIN AREAS, RAN BSDR DALA2017101007411Unknown · odorDURING ON TAKEOFF, THE FLIGHT ATTENDANTS REPORTED A STRONG ELECTRICAL BURNING ODOR COMING FROM THE FWD COFFEEMAKERS. TWO OR THREE MINUTES LATER, THEY STATED THAT THE ODOR WAS DISSIPATING AND THEN GONE. RAN QRH BUT BEFORE TURNING ANYTHING OFF THE FLIGHT ATTESDR CALA2017100803536Oven · smokeSMOKE FROM AFT GALLEY OVEN SET OFF LAVATORY SMOKE DETECTOR, OVEN TURNED OFF. REMOVED AND REPLACED OVEN POSITION 411 IAW IFM 25-32-75. OPS CHECKED, FAULTS NOTED. ACFT OK TO CONTINUE.SDR DALA2017100407274Motor · odorUPPER DECK GALLEY ELEVATOR MOTOR PRODUCING AN ELECTRICAL SMELL. R&R LIFT CART ACTUATOR WITH ELECTRIC MOTORS PER AMM 25-38-02 OPS CK GOOD WIP 374716 PER AMM 25 38 REPLACED LOWER RESTRAINT ASSY LOADED CART OPERATED SEVERAL TIMES OK FOR SERVICE.SDR CALA2017092403313Oven · inoperativeOVEN 1 204 INOP, LIGHTS FLASH AND STRANGE SMELL. R&R OVEN 1 OPS CKS GOOD.SDR CALA2017092203256Oven · defectiveGALLEY OVEN DEFECTIVE. OVEN IN GALLEY NEAR L4 DOOR INOPERATIVE. CIRCUIT BREAKER PULLED DUE TO BURNING ODOR. R & R THE OVEN AND RESET THE CIRCUIT BREAKER OPS CHECKED GOOD IAW AMM 25-34-00.
Back to JASC 2530