Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017072802379Controller · odorGALLEYS GALLEY G1A - OVEN AT GALLEY DEFECTIVE MID GALLEY OVENS HAD ACRID ODOR FROM MID ACRID ODOR FROM OVEN OVEN OFF. ODOR DISSIPATED. REMOVED AND REPLACED OVEN TEMP CONTROLLER AMM 25-20-00, OPS CHECKED GOOD.SDR CALA2017072802373Oven · smokeOVEN 410 MID GALLEY SMOKES. NO APPARENT SPILL. REMOVED AND REPLACED OVEN IAW AMM 25-34-00. OPS NORMAL.SDR AALA201707289012Oven · failedAFT GALLEY OVEN 6-11 MAKING NOISE AND HAS ODOR. REPLACED AFT GALLEY OVEN.SDR DALA2017072705821Oven · odorFA REPORTED STRONG ELECTRICAL ODOR FROM FWD GALLEY IAW QRH PROCEDURE, TURNED OFF UTILITY BUSSES AND ODOR DISAPATED. REPLACED THE OVEN ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR CALA2017072402352Coffeemaker · odorODOR IN MID GALLEY OVENS NOT IN USE TURNED OFF COFFEE POTS SMELL DISSIPATED. REMOVED AND REPLACED COFFEE MAKER 303 IAW AMM 25-34-00 OPS CHECK GOODSDR CALA2017072102306Oven · faultyPER INBD FLT ATTN, AFT GALLEY OVEN R42 VERY HOT AFTER 10 MIN ON, OVEN CB R42 TRIPPED, G3 GALLEY CB PANEL VERY HOT, PER INBD FLT ATTN WHEN OVEN DOOR OPENED ELECTRIC SMELL. REMOVED AND REPLACED OVEN AT LOCATION R42 IAW AMM 25-35-19. OPS CHECK GOOD.SDR CALA2017072102304Oven · odorOVEN SMELLS BAD 430 OVEN 430 IN AFT GALLEY HAS ELECTRICAL BURNING SMELL. REPLACED OVEN 430 REF AMM-25-34-00. OPS CHECK OK.SDR CALA2017072102299Oven · smokeGALLEY OVEN INOPERATIVE, FILLS WITH SMOKE AFTER 2 MINUTES OF USE MID GALLEY, CYCLED THE CIRCUIT BREAKER. OVEN GROUND CHECKED NORMAL.SDR AALA201707219036Coffeemaker · sparksFWD GALLEY NR 1 COFFEEMAKER SHOT OUT A SPARK WHEN TURNING OFF. REMOVED AND REPLACED THE NR 1 COFFEEMAKER IAW AMM 25-39-02. LEAK AND OPS CHECKED GOOD.SDR AALA201707249057Warmer · faultyTHE AIRCRAFT WAS NOT GROUNDED. WARMER NR 1 IN FIRST CLASS GALLEY EMITS A ELECTRICAL BURNING SMELL. R&R AT F/C GALLEY, BUN WARMER OV3 (NR 1) IAW AMM 25-32-02. OPS CKD GOOD. OKAY FOR SVC.SDR P5CA2017071600222Oven · failedDURING THE MIDDLE OF CRUISE FLIGHT, CREW OBSERVED VOLUMINOUS SMOKE EMITTING FROM THE GRILL PLATE ABOVE THE OVEN, ACCOMPANIED BY A VERY STRONG ELECTRICAL BURNING ODOR. CREW SHUTDOWN ALL ELECTRICITY IN UPPER GALLEY BY PULLING CIRCUIT BREAKERS. SMOKE GENERATIONSDR AALA201707179011Coffeemaker · failedAFT GALLEY NR 2 COFFEEMAKER IS SPARKING AND EMITTING A BURNED WIRE ODOR. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-32-00. OPERATIONAL CHECKED GOOD.SDR AALA201707269058Oven · faultyAIRCRAFT WAS NOT GROUNDED. DURING FLIGHT THE FORWARD GALLEY NR 2 OVEN OVERHEATED AND BURNT FOOD. REMOVED AND REPLACED GALLEY OVEN IAW CMM 25-35-53. OPERATIONAL CHECK GOOD.SDR CALA2017071502249Oven · smokeOVEN 411 INOP. SMOKE EMITTING FROM TURNED OFF. REMOVED AND REPLACED OVEN OPS CK GOOD REF AMM 25-34-00SDR CALA2017071402219Oven · sparksOVEN SMOKING OR SPARKING 205. REPLACED OVENSDR AALA201707149002Oven · odorRIGHT SIDE OVEN IN THE MID GALLEY IS VERY SLOW TO HEAT AND HAS A VERY STRONG CHEMICAL ODOR WHILE HEATING. CHEMICAL ODOR WAS VERY STRONG. REPLACED THE OVEN IAW AMM 25-35-19.SDR AALA201707129015Oven · sparksFORWARD GALLEY OVEN NR 1 IS INOPERATIVE. FLIGHT ATTENDANT REPORTED SPARKS. REMOVED AND REPLACED THE OVEN IAW AMM 25-32-02. OPERATIONAL CHECKED GOOD.SDR CALA2017071002139Oven · overheatedOVEN 413 AFT GALLEY OVERHEATED AFTER 15 MINUTES, SETOFF SMOKE ALARM IN LAVATORY. R & R THE OVEN. OPS CHECKED GOOD.SDR CALA2017070802113Oven · smokeGALLEY OVEN 411 INOPERATIVE, SMOKE WHEN USED. R & R THE AFT GALLEY OVEN IAW AMM 25-34-00, OPS CHECKED OK.SDR CALA2017070802111Oven · malfunctionedOVEN 107 WAS HOT EVEN THOUGH NOT IN USE ELECTRICAL ODOR COMING FROM AREA. PULLED THE CIRCUIT BREAKER AND RESET AND PERFORMED OPS CHECK NO ELECTRICAL ODOR AND OPS NORMAL.SDR AALA201707109015Oven · smokeFWD GALLEY OVEN SMOKES AND HAS A BURNING METAL ODOR. REPLACED OVEN.SDR AALA20170707007Oven · smokeEMERGENCY DECLARED, AND DIVERTED DUE TO REPORTED SMOKE FROM FORWARD GALLEY OVEN. LANDING UNEVENTFUL. REMOVED AND REPLACED NR 1 INBOARD OVEN IAW AMM 25-39-03. OPS CHECKED GOOD. AIRCRAFT WAS GROUNDED.SDR DALA2017070605231Circuit Card · burnedCREW REPORTED THE FORWARD GALLEY OVEN CONTROL PANEL CAUGHT FIRE. FLIGHT ATTENDANT PUT THE FIRE OUT WITH AN EXTINGUISHER AND SECURED THE CIRCUIT BREAKER FOR THE OVEN. MAINTENANCE REMOVED OVEN AND INSPECTED AREA. NO EXTERNAL DAMAGE FOUND. FOUND CIRCUIT CARD BUSDR ASAA2017070421292Oven · failedF/A REPORTED THE RIGHT OVEN IN FORWARD GALLEY STARTED SMOKING AND COILS WERE GLOWING RED. FA TURNED OFF OVEN BUT COILS STILL GLOWED RED. PULLED THE CIRCUIT BREAKERS. OVEN COOLED DOWN. ACFT GROUNDED. CHANGED OVEN, IAW CMM 25-36-55.SDR AALA201707039042Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED. FLIGHT ATTENDANT REPORTED ODOR IN THE AFT GALLEY. REMOVED AND REPLACED COFFEEMAKER NR 1 IAW AMM 25-35-15. LEAK AND OPERATIONAL CHECK GOOD.SDR CALA2017070202082Oven · smokeWARMING OVEN SMOKING OR SPARKING 204. REMOVED AND REPLACED OVEN, OPS CHECK GOOD AMM 25-34-00.SDR CALA2017070102075Oven · sparksMID CABIN OVEN R12 HAD SMOKE AND SPARKS WHEN TURNED ON. REMOVED AND REPLACED OVEN R12, IAW MM 25-31-00, OPS CHECK GOOD.SDR CALA2017070102072Oven · sparksOVEN SMOKING OR SPARKING 204 OVEN 204 IN 1ST CLASS GALLEY SMOKES WHEN YOU TURN IT ON. REMOVED AND REPLACED OVEN 204 IAW 25-34-00, NO SPARKS OR SMOKESDR CALA2017070102068Oven · odorOVEN PRODUCED A BAD BURNING ODOR. PULLED THE CIRCUIT BREAKJER AS A PRECAUTION, RAN OVEN, REMOVED AND REPLACED GALLEY OVEN IAW AMM 25-34-00-400-801C3, OPS NORMAL.SDR CALA2017063002025Coffeemaker · odorHEAVY ELECTRICAL ODOR IN MID GALLEY WHEN COFFEEMAKERS TURNED ON. WENT AWAY WHEN OFF IAW AMM 05-51-58-910-801C1. INSPECTION OF THE MID GALLEY AREA IAW ITM STP C1B AND 2B , ACCOMPLISHED A THOROUGH INSPECTION OF COFFEEMARKER AND WARMERS WIRING ,CIRCUIT BREAKERSSDR CALA2017063002007Oven · odorAFT GALLEY OVEN 411 HAD BURNING ELECTRICAL ODOR AFTER TURNING ON. REMOVED AND REPLACED OVEN AT 411,OPS CHECK O.K.SDR CALA2017063002006Chiller · odorAFT GALLEY CHILLERS OVERHEATED. BURNING SMELL NOTED. R&R RIGHT AFT GALLEY CHILLER IAW AMM 25-33-02-01. OPS CHECK GOOD . NO DEFECTS NOTED.SDR YENA201706290543Coffeemaker · odorDIVERTED DUE TO AN ELECTRICAL ODOR REPORTED AROUND THE FORWARD COFFEE POTS AND GALLEY AREA. FOLLOWED FLOW CHART FOR SMOKE EVENT. FOLLOWED TSM 24-00-00-810-823-A. CAUSE OF SMOKE FROM FWD COFFEEMAKER.SDR CALA2017062501978Oven · odorGALLEYS GALLEY G4A OVEN AUTO STOPS DURING COOKING, FAULT 6 DISPLAYED, FAINT ELECTRICAL ODOR. FOUND NR 1 OVEN INOPERATIVE. REMOVED AND REPLACED THE OVEN, OPS CHECKED GOOD IAW AMM 25-34-00SDR AALA201706269001Oven · smokeNR 2 OVEN IN FWD GALLEY HAD ABNORMAL AMOUNT OF SMOKE COME OUT OF OVEN (+30 MIN OF USE) WHILE REMOVING MEALS. MEALS WERE NOT BURNED AND SMOKE DID NOT SMELL LIKE BURNED FOOD OR CRUMBS. REMOVED AND REPLACED NR 1 FWD GALLEY OVEN IAW AMM 25-35-19.SDR CALA2017062301940Chiller · odorMID GALLEY ELECTRICAL ODOR. ALL CIRCUIT BREAKERS PULLED, ODOR STOPPED. REPLACED THE CHILLER, OPS OK.SDR AALA201706219003Fan · failedFORWARD GALLEY LEFT OVEN PERODICALLY MAKES VERY LOUD NOISE WHEN THE FAN RUNNING AND THE FAN SPARKS AND SMOKES IN THE AREA BEHIND THE FAN SHROUD ON THE INSIDE OF THE OVEN. MAINTENANCE REPLACED THE OVEN IAW MM 25-35-19-401.SDR CALA2017061901898Coffeemaker · odorUPON DECENT FA CALLED COCKPIT TO REPORT BURNT ELECTRIC SMELL NEAR GALLEY. REMOVED AND REPLACED COFFEEMAKER 106 AND BREWED OPS CHECKS GOOD.SDR AALA201706199027Oven · faultySTRONG ELECTRICAL ODOR FROM BUSINESS CLASS GALLEY OVEN. REMOVED AND REPLACED THE OVEN IAW AMM 25-32-00. OPERATIONAL CHECKED GOOD.SDR DALA2017062104875Oven · failedWHEN GALLEY OVEN WAS TURNED ON, THE FAN WAS NOISY AND SMOKE WAS PRESENT. OVEN WAS TURNED OFF AND SMOKE CEASED. CIRCUIT BREAKER WAS PULLED AND COLLARED.SDR ASAA2017061621105Coffeemaker · odorFAS REPORT ELECTRICAL ODOR COMING FROM AFT GALLEY COFFEEMAKERS. CIRCUIT BREAKERS PULLED, ODOR DISAPPEARED. ACFT GROUNDED. REMOVED AND REPLACED THE AFT GALLEY COFFEEMAKER. REVERSED SPECIAL PROCEDURE. OPS CHECKED GOOD.SDR AALA201706169016Coffeemaker · odorSTRONG ELECTRICAL ODOR FROM THE MID GALLEY LASTING 10 MINUTES. ACCOMPLISHED ODOR WORKCARD 21-92-01. REMOVED AND REPLACED ESPRESSO MACHINE. OPERATIONAL CHECK GOOD.SDR DALA2017061404727Oven · smokeREPORTED SMOKE IN THE CABIN DURING TAXI. SMOKE SEEMED TO BE COMING FROM ONE OF THE OVENS AND THE SHIP RETURNED TO THE GATE. REPLACED THE OVEN.SDR CALA2017061001787Oven · failedOVEN 106 FWD BURNS FOOD AND SMOKES. TEMP UNCONTROLABLE. FIRE HAZARD. R & R THE OVEN. ALL OPS OK.SDR CALA2017060901740Controller · faultyOVEN 106 OVERHEATS WHILE COOKING. BURNS FOOD AND SMOKES. TEMP CONTROL UNCONTROLLABLE. REMOVED AND REPLACED OVEN TEMP CONTROLLER. OVEN OPERATES NORMAL WITH CONTROLLING (CYCLING) TEMPERATURE.SDR AALA201706079018Coffeemaker · defectiveTHE AIRCRAFT WAS NOT GROUNDED. FLIGHT ATTENDANTS REPORTED THAT WHEN TRYING TO USE THE LOWER AFT GALLEY COFFEE MAKER, A BURNING SMELL EMANATED AND THEY TURNED IT OFF. REPLACED AFT GALLEY COFFEE MAKER NUMBER 5 IAW AMM 25-32-00 CKS GOOD.SDR CALA2017060501687Oven · sparksOVEN SMOKING OR SPARKING 205 OVEN 2 SMOKES ON HIGH BURNING WALL LINER REMOVED AND REPLACED GALLEY OVEN 205.SDR CALA2017060501686Oven · odorOVEN IN AFT GALLEY HAS BURNING ELECTRICAL ODOR WHEN IN USE. REPLACED OVEN R53 WITH NEW OVEN PER MM 25-32-02SDR AALA201706059001Coffeemaker · odorAFT CABIN ODOR. VERIFIED AFT GALLEY NR 2 COFFEEMAKER CAUSING ODOR. REMOVED AND REPLACED THE COFFEEMAKER.SDR AALA201706059003Oven · inoperativeFORWARD GALLEY OVEN INOPERATIVE. BURNING PLASTIC ODOR WHEN HEATING. MAINTENANCE REPLACED THE OVEN IAW AMM 25-35-19.
Back to JASC 2530