Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2540' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2021020100107Beam · corrodedM/D LAV M LWR THRESHOLD BEAM FOUND CORROSION REF NON-ROUTINE NR 9423357. M/D LAV M LWR THRESHOLD BEAM REPLACED AS PER ECRA 2541-01533 REV.SDR CALA2021020100106Frame · corrodedM/D LAV M O/B VERTICAL FRAME FOUND CORROSION REF NON-ROUTINE NR 9423362. M/D LAV M O/B VERTICAL FRAME REPLACED AS PER ECRA 2541-01533 REV.SDR CALA2021020100105Frame · corrodedM/D LAV L O/B VERTICAL FRAME FOUND CORROSION REF NON-ROUTINE NR 9423364. M/D LAV L O/B VERTICAL FRAME REPLACED AS PER ECRA 2541-01534 REV.SDR CALA2021020100104Beam · corrodedM/D LAV L LWR THRESHOLD BEAM FOUND CORROSION REF NON-ROUTINE NR 9423359. M/D LAV L LWR THRESHOLD BEAM REPLACED AS PER ECRA 2541-01534 REV.SDR CALA2021020100103Beam · corrodedCAB LAV L THRESHOLD BEAM FOUND CORROSION, REFER NON-ROUTINE NR 9423784. CAB LAV L THRESHOLD BEAM REPAIRED AS PER ELRA 2541-01531.SDR CALA2021020100102Beam · corrodedCAB LAV M THRESHOLD BEAM FOUND CORROSION, REFER NON-ROUTINE NR 9423770. CAB LAV M THRESHOLD BEAM REPAIRED AS PER ECRA 2541-01532 REV.SDR SWAA2021022244610Plate · wornWEAR ON GIRT BAR FITTING ADAPTER PLATE(4EA) AND ALL HARDWARE AT AFT GALLEY AREA / REPLACED GIRT BART FITTING ADAPTER PLATE(4EA) AND ALL HARDWARE AT AFT GALLEY AREA IAW B737-700 AMM 25-66-02-400-801SDR SWAA2021032523789Threshold · canningAFT LAV DOOR METAL THRESHOLD OIL CANNED. REQUIRES REMOVAL FOR FURTHER INSPECTION. / REMOVED AND REPLACED AFT LAV. THRESHOLD PER SRM 51-40-02SDR SWAA2020082811937Lavatory · odorPAX REPORTED PLASTIC BURNING ODOR IN FWD LAV; IT WAS CONFIRMED BY A FLT ATT. ALSO REPORTED HOT CEILING IN LAV. THERE WAS NO VISIBLE SMOKE AND THE ODOR DISSIPATED DURING DESCENT. LANDED UNEVENTFULLY. FIRE DEPART REPORTED NO GAS OR ELEVATED TEMPERATURE IN LAV. /SDR 120B2020071600103Control Module · failedAFT LAV LIGHT ILLUMINATED AND WILL NOT CLEAR.SDR 120B2020071400078Indicator · wornFORWARD LH LAVATORY (FS3) WASTE COMPARTMENT TEMPERATURE INDICATOR NEEDS REPLACEMENT.SDR FDEA2020050410868Unknown · odorAIRCRAFT UNUSABLE . FUMES IN COCKPIT FROM DISINFECTANT IS OVERWHELMING. ESPECIALLY ON F/OS SIDE. SUSPECT FLUID IN THE LAV IS THE PROBLEM. WHEN LAV DOOR IS OPEN FUMES ARE EXTREMELY STRONG. FLIGHT CREW DEBRIEF REVEILED THAT ODOR /FUMES WAS COMING FROM LASDR DALA2020040602192Unknown · fireSHIP 3801 DIVERT TO DENVER DUE TO PAX STARTED FIRE IN AFT LEFT SIDE AFT LAV . CORRECTIVE ACTION: INSPECTED AFT LAV,NO DAMAGE FOUND, INSPECTED DOORS, AND ALL COMPARTMENTS NO TROUBLE FOUND, OK FOR SVC (7132068).SDR CALA2019092801657Mechanism · failedLAV E DOOR STUCK CLOSED. LOCK MECHANISM FAILED IN THE LOCK POSITION. SLIGHT DAMAGE TO BIFOLD DOOR AND DOOR FRAME WHILE TRYING TO RELEASE DOOR LOCK TO GAIN ACCESS TO PASSENGER. REPLACED E DOOR BI FOLD ASSY REF AMM 25-41-02-400-801C1 LOCKS UNLOCKS OKSDR SCNA20190907133Attach Fitting · delaminatedLAV A FWD OUTBOARD FLOOR ATTACH FITTING STRUCTURE DELAMINATED ADJACENT TO FITTING. REPAIRED LAV.SDR AALA201909069001Lock · out of adjustAIRCRAFT NOT GROUNDED: LEFT AFT LAV LOCKING MECHANISM VERY LOOSE CAUSING PEOPLE TO GET LOCKED INSIDE LAV. LT AFT LAV LOCKING MECHANISM WAS ADJUSTED IAW AMM 25-43-00, OK FOR SERVICE IAW AMM 25-43-00.SDR AALA201909059003Mechanism · out of adjustAIRCRAFT NOT GROUNDED: LAV 2L WILL NOT UNLOCK FROM INSIDE. ADJUSTED LOCK MECHANISM OF LAV 2L IAW ESO 21410 AND CMM 25-45-80. OPS CKD OK IAW ESO 21410.SDR I5EA2019052100032Toilet · overflowDISCREPANCY: AIR RETURN TO MDSD DUE TO LT AFT TOLIET OVER FLOWING INTO GALLEY AREA. CORRECTIVE ACTION: CLEANED AFT LT LAV AND GALLEY AREA. PERFORMED CONDITIONAL INSPECTION FOR TOLIET OVERSERVICING AND OVERWEIGHT LANDING IAW AMM 05-51-12 AND 05-51-74.SDR I5EA2019052800014Block · damagedDISCREPANCY: COMPLETE EO SWA-190203S, REV: IR, DATED: 02-15-2019. CORRRECTIVE ACTION: ACCOMPLISHED L/H AFT "D" LAVATORY REPAIR COMPOSITE EXTERIOR SURFACE AND FABRICATION ALUMINUME FLOOR FITTING BLOCKS PER EO SWA-190203S, REV: IR, DATED: 02-15-2019.SDR I5EA2019052800015Block · damagedDISCREPANCY: COMPLETE EO SWA-190203S, REV: IR, DATED: 02-15-2019. CORRRECTIVE ACTION: ACCOMPLISHED FWD "A" LAVATORY REPAIR COMPOSITE EXTERIOR SURFACE AND FABRICATION ALUMINUME FLOOR FITTING BLOCKS PER EO SWA-190203S, REV: IR, DATED: 02-15-2019.SDR I5EA2019052800013Block · damagedDISCREPANCY: COMPLETE EO SWA-190203S, REV: IR, DATED: 02-15-2019. CORRRECTIVE ACTION: ACCOMPLISHED RT AFT "E" LAVATORY REPAIR COMPOSITE EXTERIOR SURFACE AND FABRICATION ALUMINUME FLOOR FITTING BLOCKS PER EO SWA-190203S, REV: IR, DATED: 02-15-2019.SDR FDEA201905101024Latch · failedDURING POST FLIGHT CHECK FOUND LATCH ON, LAVATORY ACCESS DOOR, BENEATH SINK BROKEN. IN REF TO DISC. 25-40/5348 PREVENTIVELY SET LAV TO INOP RELEASED FOR SERVICE PER MEL : 25-41-01 CATEGORY : C EXPIRATION : 19MAY19 "MEL 25-41-01: LAVATORY WASTE CONTAINER FLAPPSDR AALA201905089008Knob · out of adjustAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR LOCK WOULD NOT TURN, DOOR LOCKED CLOSED. MAINTENANCE ADJUSTED FORWARD LAVATORY KNOB PER AMM 25-45-19.SDR CA190312002Doubler · corroded(CAN) LAVATORY PRESSURE BOX INNER DOUBLER CORRODED. AFTER INVESTIGATION FOUND INTERCOSTAL (P/N S53671402200) AND STRINGER #21 (P/N S53671407214020) BTW FR 40-42 CORRODED.SDR AALA201902139007Latch · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY BI-FOLD DOOR WAS STUCK. MAINTENANCE ADJUSTED RIGHTHAND AFT DOOR LATCH PER 25-45-21 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201901079023Door · out of adjustAIRCRAFT WAS NOT GROUNDED: RIGHT AFT LAVATORY DOOR WAS DIFFICULT TO OPEN. MAINTENANCE ADJUSTED RIGHT AFT LAVATORY DOOR ASSEMBLY AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201901079005Door · out of adjustAIRCRAFT WAS NOT GROUNDED: LAVATORY 4FL (AFT LEFT) DOOR DIFFICULT TO OPEN AND CLOSE. MAINTENANCE READJUSTED AFT LEFT HAND TOILET DOOR AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201901079009Door Frame · unsecureAIRCRAFT WAS NOT GROUNDED: F1 LAVATORY DOOR HARD TO OPEN. MAINTENANCE RESECURED LAVATORY F1 DOOR FRAME ASSEMBLY PER CMM 25-40-71 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201901079006Door · unsecureAIRCRAFT WAS NOT GROUNDED: LAVATORY 4F-R DOOR WAS DIFFICULT TO OPEN. MAINTENANCE SECURED LAVATORY 4F-R DOOR AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER ESO 21411.SDR AALA201901079020Hinge · lack of lubeAIRCRAFT WAS NOT GROUNDED: L1 LAVATORY DOOR WAS DIFFICULT TO OPEN. MAINTENANCE LUBRICATED LAVATORY DOOR HINGE L1 AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 25-41-02.SDR AALA201810019038Door · fodR1 DOOR ARMING LEVER WILL NOT INDICATE ARMED. THE AIRCRAFT WAS GROUNDED. REMOVED DEBRIS FROM THE R1 DOOR. OPS CHECKED OK IAW AMM 25-62-42.SDR GTIA2018091402845Door · unsecureFRONT LAV BIN DOOR FOUND ON FLOOR NOT CONNECTED TO HINGES. REATTACHED DOOR AS NEEDED REF MM 25-41-00.SDR 7C7A2018051424Fitting · corrodedCORROSION FOUND ON THE TOP OF LAVATORY CASTING AT BS 210, BETWEEN STRINGERS 25 - 27R. THE FITTING WAS REPLACED.SDR AALA201803069008Bottle · low pressureR2 DOOR ASSIST ACTUATOR BELOW MINIMUM PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW 52-22-00.SDR AALA201802269034Cylinder · low pressureR1 DOOR EMERGENCY CYLINDER ACCUMULATOR PRESSURE IS AT 950 PSI AT 46F. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201712289015Actuator · sticksAIRCRAFT NOT GROUNDED. LAVATORY D DOOR STICKS AND IS DIFFICULT TO OPEN AND CLOSE. PROPERLY INSTALLED DOOR ACTUATOR AS REQUIRED. OPERATIONS CHECK GOOD.SDR AALA201712129056Latch · out of adjustAIRCRAFT WAS NOT GROUNDED. DOOR OF LAVATORY 2F-1L, (NEAR DOOR 2L), DOES NOT UNLOCK CORRECTLY AND GETS STUCK IN LOCKED POSITION. ADJUSTED DOOR LATCH AT LAVATORY 2F-1L PER CMM 25-45-80. OPERATIONAL CHECK NORMAL.SDR AALA201712129053Counter · meltedAIRCRAFT WAS NOT GROUNDED. BURNING SMELL IN THE LEFT AFT LAVATORY. INSPECTION SHOWED SOMETHING HAS MELTED THE LAW COUNTER. NO EVIDENCE OF FIRE IN AFT LAVATORY ODOR CAUSED BY MELTED COUNTER TOP. OK FOR SERVICE.SDR AALA201711269010Latch · brokenAIRCRAFT WAS NOT GROUNDED. DURING DESCENT, THE FORWARD LAVATORY SMOKE ALARM ALERTED WITH NO SIGN OF ACTUAL SMOKE. SMOKE ALARM ACCESS PANEL LATCH IS BROKEN. REMOVED AND REPLACED LAVATORY A SMOKE ALARM PANEL LATCH PER AMM 25-41-49. OPERATIONAL CHECK GOOD.SDR HNAA2017092000322Knob · missingLAV DOOR EMERGENCY KNOB MISSING. INSTALLED NEW EXTERNAL LAV KNOB IN REF TO AMM 25-40-02-000/400-801-A. OK FOR SERVICE.SDR CALA2016072800455Lavatory · smokeSMOKE LAVATORY EICAS ADVISORY, SMOKE CONDITION DETECTED IN ONE OR MORE LAVATORIES. SMOKE ODOR AT LAVATORY H, NO FLT ATT CHIMES . LAVATORY SMOKE DETECTOR TEST PASSED IAW AMM 26-13-00. OPS CK OK.SDR SIMA20160316006Support · corrodedSSI 53-20-29 TOILET WASTE VLV SUPPORT, LAVATORY BUCKET, IS CORRODED. R & R LAVATORY BUCKET IAW SRM 51-40-02SDR AALA20151214006Circuit Board · burnedLAVATORY 3F1RC HAD AN ELEC BURNING SMELL, NO SMOKE VISIBLE. FLIGHT ATTENDANT TURNED ELEC DRAIN SWITCH TO OFF & SMELL DISSIPATED. FOUND THE LAVATORY 3F1RC GWIV PC BOARD BURNT. R & R GWIV IAW AMM 38-31-11. OPERATIONAL & LEAK CHECKED GOOD.SDR CA150922004Sink · leaking(CAN) UPON CLIMBOUT THE CREW OBSERVED AN UN-COMMANDED TRIM WITHOUT THE ASSOCIATED PHYSICAL CHARACTERISTICS BUT AUDIBLE TONES WERE HEARD. ADDITIONALLY, SEVERAL MESSAGES APPEARED TO INCLUDE AN AMBER FLIGHT SPOILER FAILURE WITH AN ASSOCIATED SLAT/FLAP HALF SPEEDSDR C40A20150924001Plunger · obstructedCRUISE AT FL360, ACFT EXPERIENCED A REAR BAY DOOR MWS INDICATION IMMEDIATELY FOLLOWED BY CABIN ALTITUDE. CREW & PAXS DONNED 02 MASKS. CREW DESCENDED TO SAFE ALTITUDE & RETURNED TO BASE. INSPECTION REVEALED TRASH ON PLUNGER FOR TOILET PREVENTING PROPER SEAL.SDR U5QA2015826068Door · brokenDECLARED EMER DUE TO PAX BEING TRAPPED IN LAVATORY, DOOR STUCK, WOULD ONLY OPEN ABOUT 1/4 INCH. NOTE THAT LAVATORY SEAT IS BELTED. ACFT IN MX NOW TO FIX. PICS RECEIVED FROM MX VENDOR REFLECT BOTTOM OF SLIDE AT BOTTOM OF DOOR WOULD NOT RETRACT WHILE CLOSING.SDR MASA2015032612977Bottle · low pressureDURING OVERNIGHT E-1, LC-1, & SERVICE CHECK INSPECTION, THE AFT SERVICE DOOR PNEUMATIC ASSY PRESSURE WAS FOUND AT 1500 PSI. AFT SERVICE DOOR WAS SERVICED UP 2300 PSI M5523380 WAS GENERATED TO ACCOMPLISH A GVI OF THE PRESSURE ASSY AFTER 24 HRS & REPEATED AT 48SDR UIEA2015012600026Latch · lack of lubeLAVATORY C WASTE BIN DOOR DOES NOT CLOSE CORRECTLY. LUBRICATED LAVATORY C WASTE BIN DOOR LATCH & HINGES IAW AMM 12-21-00.SDR UIEA2015012600024Door · damagedLAVATORY G WASTE BIN DOOR HAS EDGE DAMAGE & LOWER CORNER IS CRACKED. REPAIRED & PAINTED LAVATORY G WASTE BIN DOOR IAW AMM 25-00-00.SDR UIEA2015012600016Sidewall Panel · bowedLAVATORY AC 3 HAS A BOWED OUT SIDEWALL, INBD, AFT LOWER. R & R, REINSTALLED LAVATORY AC 3 IAW AMM 25-41-04.
Back to JASC 2540