JASC 2560
Service difficulty reports · 40,687
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202107203528Girt Bar · stuckAIRCRAFT WAS NOT GROUNDED: 1R DOOR GIRT BAR STUCK IN ACTUAL DOOR. UNABLE TO FREE GIRT BAR. RESECURED GIRT BAR ON GIRT BAR RETAINER CLIPS ON DOOR PER AMM 25-66-01.SDR SWAA2021072195777Megaphone · brokenTHE FLIGHT ATTENDENT HAND HELD MEGAPHONE IS BROKEN. / R&R FA MEGAPHONE PER AMM 25-64-00SDR GTIA2021071935880Bottle · low pressureR2 DOOR ASSIST REQURIES NITROGEN SERVICE-SERVICED R2 DOOR ASSIST BOTTLE WITH NITROGEN PER AMM 52-10-00SDR GTIA2021071935879Bottle · low pressureL2 CABIN DOOR ASSIST BOTTLE BELOW SERVICABLE LIMITS-SERVICED L2 CABIN DOOR ASSIST BOTTLE IAW AMM 52-11-00SDR WX0A2021071973770Flashlight Assy · inoperativeFWD FA (INBOARD) EMERGENCY FLASHLIGHT NOT CHARGING. / R&R'D FWD FA (INBOARD) EMERGENCY FLASHLIGHT IN REF TO AMM 25-65-00. OPS CHECK GOOD."SDR DALA2021071904049Psu · no testSHIP 3250 DURING TEST PSU OXY PANEL 02DC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7756892)SDR DALA2021071904047Psu · no testSHIP 3250 DURING TEST PSU OXY PANEL 29ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7756895)SDR DALA2021071904046Psu · no testSHIP 3250 DURING TEST PSU OXY PANEL 23DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7756894)SDR DALA2021071904045Psu · no testSHIP 3250 DURING TEST PSU OXY PANEL 27ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7756893)SDR AALA202107202286Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: LH AFT FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT BATTERY IAW AMM 25-64-00, OPS CHECK GOOD.SDR AALA202107205216Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: FWD EMERGENCY FLASHLIGHT BATTERY INOPERATIVE. REPLACED EMERGENCY FLASHLIGHT BATTERY IAW MCM WORKCARD 0094, OPS CHECK GOOD.SDR SWAA2021072095587Hook · looseSLIDE PACK ON GALLEY SERVICE DOOR APPEARS LOOSE ; / [01] TIGHTENED GIRT BAR J-HOOKS PER SIP.SDR SWAA2021072095467Stop · missingAFT SERVICE DOOR GIRT BAR STOP RELEASE MISSING ; / [01] INSTALLED STOP RELEASE ON AFT SERVICE DOOR GIRT BAR I.A.W. AMM 20-00-00SDR SWAA2021072095762Stop · missingAFT SERVICE DOOR GIRT BAR STOP RELEASE MISSING / INSTALLED STOP RELEASE ON AFT SERVICE DOOR GIRT BAR IAW AMM 20-00-00SDR SWAA2021072095004Rivet · shearedCABIN L1 FWD. ENTRY DOOR GIRT BAR AFT STOW BRACKET NOT SECURE.(MARKED) / [01] FOUND RIVET SHEARED ON BRACKET. R&R FASTENER PER SRM 51-40-02SDR GTIA2021071935878Bottle · low pressureL1 DOOR ASSIST BOTTLE REQ SERVICING-SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2021071935877Bottle · low pressureR1 DOOR ASSIST BOTTLE LOW -SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR GTIA2021071935876Bottle · low pressureL1 DOOR AND R2 DOOR SLIDE ASSIT BOTTLE NEED SERVICING -SERVICED L1 AND R2 DOOR SLIDE ASSIT BOTTLE IAW AMM 52-10-00. NO LEAKS NOTED AT THIS TIME.SDR CALA2021071601112Battery · failedFWD PORTABLE ELT BITE TEST FAILS. REPLACED ELT BATTERY, PERFOMED BITE TEST REF AMM / TASK 25-64-05-700-801-C2 ALL CHECKS GOODSDR SWAA2021071995849Flashlight · failedSUPPLEMENTAL INFORMATION: FLASH LIGHT TEST FAILS ON FLASH LIGHT AFT OF CAPT SEAT. / RESEATED FLASH LIGHT ON CRADLE AFT OF CAPT SEAT IAW AMM 25-64-00 OPS CK GOODSDR SWAA2021071994954Girt Bar · out of positionR2 DOOR SLIDE GRIT BAR DRAGGING ; / [01] REPOSITIONED R-2 DOOR SLIDE GIRT BACK INTO PLACE. OPERATED DOOR NO DEFECTS NOTED. REF B737 AMM 25-66-01-400-803.; [02] VERIFIEDSDR DALA2021071904070Indicator · inoperativeSHIP 5816 SLIDE ARMED LIGHT DOOR 1L REPORTED INOP. CORRECTIVE ACTION: ACCOMPLISHED B757 CLEAN, INSP, LUBE, TEST WORK CARD 5211-2301, NTF. OP CHK NORMAL DURING NUMEROUS FUNCTION CHECKS. (7922029)SDR CALA2021071601110Frame · crackedRH FWD OVERWING EMERGENCY EXIT DOOR HAS CRACK IN INTERIOR AFT SUPPORT BRACE. REF N/R 11035.0333SDR CALA2021071601109Frame · crackedRH FWD OVERWING EMERGENCY EXIT DOOR HAS CRACK IN INTERRIOR FWD SUPPORT BRACE. REF N/R 11035.0334SDR GTIA2021071535874Bottle · low pressureL1 & L3 DOR ASSISTANCE BOTLLE-SERVICE L2 & L3 DOOR BOTTLE ASSISTANCE TO PROPER LEVEL IAW AMM 52-10-00SDR GTIA2021071535870Bottle · low pressureDURING WEEKLY CHECK FOUND L1 DOOR ASSIST REQ SERVICE-SERVICED L1 DOOR ASSIST PER AMM 52-10-00 NO LEAKS DETECTEDSDR IPXA2021071471669Warning Light · inoperativePREFLIGHT - DOOR SLIDED ARMED WARNING RED LIGHT WOULD NOT ILLUMINATE WHEN PRESS TO TEST BUTTON ACTIVATED. ITEM PLACED ON M750206 PER MEL 52-73-01-1 NO MX PROCEDURES REQUIRED. PLACARD INSTALLED.REPLACED APSU 7OWN PER A300 AMM 57-73-18-0401. OPS CK OK,SDR GTIA2021071535869Bottle · low pressureR1 DOOR ASSIST BOTTLE PRE CHARGE LOW. -SERVICED R1 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR AALA202107151972Cylinder · low pressureAIRCRAFT IN BASE MAINTENANCE: DID NOT PASS OPERATIONAL TEST PASSENGER CREW DOOR 831 DAMPING FUNCTION AT FORWARD GALLEY AREA. REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER ON PASSENGER CREW DOOR 831 PER AMM 52-11-14-400-001-B.SDR AALA202107154801Reservoir · low pressureAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER ASSIST RESERVOIR GAGE IS LOW. REMOVED AND REPLACED EMERGENCY POWER ASSIST SYSTEM RESERVOIR PER AMM 52-11-22.SDR AALA202107142385Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED L1 DOOR ASSIST BOTTLES TO CORRECT PRESSURE PER AMM 52-10-00.SDR AALA202107142461Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L3 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED L3 DOOR ASSIST BOTTLES TO CORRECT PRESSURE PER AMM 52-10-00.SDR AALA202107141068Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R4 DOOR ASSIST BOTTLES TO CORRECT PRESSURE PER AMM 52-10-00.SDR IPXA2021071371648Evas Unit · inoperativeCAPT'S L/H EVAS, COCKPIT SMOKE VISION SYSTEM , INOP. DEFERRED CAPT'S EVAS IAW MEL 25-60-01, DMP C/W, PLACARD INSTALLED,PARTS ORDERED ON REQ# 359345, A/C OK TO CONTINUE, P/N OFF 107STC-265, S/N OFF 0050Y03PINSTALLED A NEW LH EVAS IAW 757 AMM 25-69-00-400-801C1SDR AALA202107206425Cover · missingAIRCRAFT WAS NOT GROUNDED: 16A EMERGENCY WINDOW LANYARD COVER MISSING. **SUPPLEMENTAL REPORT FOR AALA202107196425: INSTALLED MISSING COVER AT 16A EMERGENCY WINDOW LANYARD PER AMM 25-21-00.** (CLOSED)SDR AALA202107196425Cover · missingAIRCRAFT WAS NOT GROUNDED: 16A EMERGENCY WINDOW LANYARD COVER MISSING. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)SDR UIEA2021071201519Seat Belt · damagedCOCKPIT F/O R/H SEAT BELT TSO TAG DAMAGE(<P>REMOVED AND REPLACED LAP BELT @ FIRST OFFICER SEAT IAW 767 AMM 25-11-00.</P> / <P>OPERATIONAL CHECK IS NORMAL PER AMM 25-11-01.</P>)SDR UIEA2021071201525Containment Bag · openMAIN DECK FIRE CONTAINMENT BAG AT AFT L/H CLOSET VACUUM SEAL BROKE P/N AS-002-1(<P>REMOVED & REPLACED AVSAX CONTAINMENT BAG AT AFT L/H CLOSET AS REQUIRED PER AMM 25-64-00. CK'D OK .</P>)SDR DALA2021071504027Indicator · inoperativeSHIP 172 AFT RIGHT SLIDE INDICATOR IS INOPERATIVE. CORRECTIVE ACTION: REPLACED SLIDE LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL. (LP 7525452)SDR AALA202107153969Concentrator · inoperativeAIRCRAFT WAS GROUNDED: L4 / R4 DOOR AREA FLIGHT ATTENDANT PANEL EMERGENCY EVACUATION SIGNAL SYSTEM INOPERATIVE. **SUPPLEMENTAL REPORT FOR AALA202107143969: REPLACED REMOTE DATA CONCENTRATOR 19 PER AMM 42-21-07.** (CLOSED)SDR AALA202107155426Bottle · low pressureAIRCRAFT WAS GROUNDED: 1L DOOR ASSIST BOTTLE EMPTY AND NEEDS SERVICED. SERVICED 1L DOOR ASSIST BOTTLE PER AMM 52-10-00.SDR DALA2021071403993Cover · missingSHIP 696 L4 DOOR FWD GIRT BAR SENSOR S10222 COVER PLATE MISSING. CORRECTIVE ACTION: INSTALLED L4 DOOR FWD GIRT BAR SENSOR COVER REF ERA 5609801-14MA REV A. (7630207)SDR AALA202107143303Cylinder · no testAIRCRAFT IN BASE MAINTENANCE: PASSENGER / CREW DOOR 831 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER FAILS OPERATIONAL TEST. REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-11-14-400-001-B.SDR AALA202107143969Control Panel · inoperativeAIRCRAFT WAS GROUNDED: L4 / R4 DOOR AREA FLIGHT ATTENDANT PANEL EMERGENCY EVACUATION SIGNAL SYSTEM INOPERATIVE. (OPEN)SDR DALA2021071403977Psu · no testSHIP 3257 DURING TEST PSU FAILED TO DROP AT SEAT L/H ROW 19. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (1873896)SDR SWAA2021071593453Battery · faultedFORWARD INBOARD EMERGENCY FA BATTERY FLASHING RED. / REMOVED AND REPLACED BATTERY FORWARD INBOARD EMERGENCY FA BATTERY IAW AMM 25-64-00SDR SIMA20210712001Flashlight · inoperativeFA FLASHLIGHT FOUND NOT CHARGING-C/A-RAR FA FLASHLIGHT IAW EMB AMM 33-50-16-000-801 AND 33-50-16-400-801. OPS CHECK GOOD. NO DEFECTS NOTED. END.SDR AALA202107133954Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR BOTTLE READS LOW. SERVICED R3 DOOR BOTTLE PER AMM 52-10-00-614-001.SDR AALA202107138110Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR ASSIST PRECHARGE LEVEL LOW ON DOORS 1R. SERVICED DOORS 1R PER AMM 52-10-00-614-001A.SDR AALA202107133912Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR ASSIST PRECHARGE LEVEL LOW ON DOORS 4R. SERVICED DOORS 4R PER AMM 52-10-00-614-001A.
Back to JASC 2560