JASC 2560
Service difficulty reports · 40,687
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2021041935691Bottle · low pressureFOUND L1 & R2 DOOR ASSYST ACCUMULATOR LOW.-SERVICED L1 & R2 DOOR ASSYST BTL ACCUUMULATOR IAW AMM 52-10-00.SDR FDEA202104180950Evas Unit · failedWHILE COMPLYING WITH EO H-2560-E0324416, REV G POS. P2. FOUND LT EVAS BATTERY TEST BUTTON REMAINED DEPRESSED AND UNABLE TO TEST. REMOVED AND REPLACED LT EVAS REF AMM 25-99-99-4. OPS CHECKED GOOD.SDR SIMA20210418003Cradle · brokenFLT DECK FA EMERGENCY FLASHLIGHT HOLDER CA FLASH LIGHT HOLDER CLAMP BROKEN MEL 2532 - AUTH# 04-141M-C REF LOGPAGE 4689409 ITEM 1-C/A-RAR CA FLIGHT DECK ATTENDANT EMERGENCY FLASHLIGH ASSY IAW EMB AMM 33-50-16. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TISDR AALA202104199030Escape Rope · deployedAIRCRAFT WAS GROUNDED: FLIGHT DECK ESCAPE DEVICE POSITION NO. 2 DEPLOYED AND SEAL BROKEN. REPLACED FLIGHT DECK ESCAPE DEVICE REEL POSITION #2 IAW 787 AMM 25-61-02-00B-702A.SDR SWAA2021042164620Battery · inoperativeAFT RIGHT GALLEY FLASHLIGHT INOP OK TO CONTINUE PER MEL 251201 SP#1B TRACKING NO. 76767. R/R FLASHLIGHT BATTERY IAW 256400 OPS CHECK GOOD CL# 76851.SDR SIMA20210417002Flashlight Assy · inoperativeEMERGENCY FLASHLIGHT NEAR LAV WILL NOT CHARGE. DEFERED AFT EMERGENCY FLASHLIGHT PER MEL 25-32. AUTH # 040240M-C. M PROCEDURES COMPLIED WITH. R & R FLASHLIGHT ASSEMBLY BEHIND LAST ROW DOUBLE SEAT IAW AMM 33-50-16. OPS CHECK GOOD. MEL ITEM RESTORED. DEFERED AFSDR AALA202104199029Escape Rope · deployedAIRCRAFT WAS GROUNDED: FLIGHT DECK ESCAPE DEVICE POSITION NO. 1 DEPLOYED AND SEAL BROKEN. REPLACED EMERGENCY DECENT DEVICE IAW 787 AMM 25-61-02.SDR DALA2021042002317Spring · weakSHIP 6716 1R KNUCKLE KNOCKER SPRING IS WEAK. CORRECTIVE ACTION: FOUND DOOR 1R MIDDLE SECTION OF DOOR LINIMG INTERFERING WITH KNUCKLE KNOCKER. ADJUSTED POSITION OF DOOR LINING PER B757 AMM 52-11. OPS CHECK GOOD. (7399684)SDR DALA2021041902281Life Line · missingSHIP 3145 - DURING 60 DAY RFID SCAN FOUND ESCAPE LIFE LINE MISSING AT LOCATION 14DEF OVERHEAD BIN. CORRECTIVE ACTION: INSTALLED NEW LIFE LINE AT LOCATION 14DEF. ( 6008491)SDR DALA2021041902280Bottle · low pressureSHIP 3144 - FOUND LH1 DOOR ASSIST ACCUMULATOR REQUIRE RE-CHARGING. CORRECTIVE ACTION: PERFORMED SERVICING IAW A319 AMM TASK. (7652704)SDR AALA202104199025Hook · looseAIRCRAFT WAS NOT GROUNDED: 1R GIRT BAR STOWAGE CLIP LOOSE. ADJUSTED GIRT BAR STOWAGE CLIP ON DOOR 1R PER AMM 25-61-00.SDR GTIA2021041935690Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR REQUIRES SERVICE-L1 DOOR ACCUMULATOR WAS SERVICED IAW AMM 52-10-00SDR GTIA2021041935689Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR LOW-SERVICED L1 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR DALA2021042002318Girt Bar · partial deploySHIP 6704 PARTIAL DEPLOYMENT OF GIRTBAR AT DOOR L1. CORRECTIVE ACTION: INSPECTED GIRT BAR PER 757AMM 25-66-10 UNHOOKED GIRTBAR FROM SLIDER AND REATTACHED DOOR OPERATES AND ARMS NORMAL. (7558554)SDR DALA2021042002311Light · inoperativeSHIP 649 ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHTS - BOTH 1L AND 1R DOOR SLIDE LIGHT INOP. CORRECTIVE ACTION: RESET P11-4 (R33), (R34). ALL DOOR SLIDE LIGHTS OPERATE NORMALLY. (1783621)SDR SWAA2021042064878Battery · no testAFT LFT FLASHLIGHT WILL NOT TEST. REMOVED AND REPLACED BATTERY PER MM 256400.SDR SWAA2021042064547Smoke Detector · activatedFORWARD LAVATORY SMOKE ALARM SOUNDED DURING DESCENT. NO SMOKE SEEN OR DETECTED. IN FLIGHT. THE FORWARD FLIGHT ATTENDANTS DID SMELL SOMETHING ELECTRICAL AFTER LANDING. / REPLACED FWD LAV SMOKE DETECT IAW AMM 26-14-01; OPS CHECK OK. C/W 05-51-26; NO DISCREPANCIESDR AALA202104189004Megaphone · inoperativeAIRCRAFT WAS GROUNDED: AFT MEGAPHONE INOPERATIVE. REMOVED AND REPLACED MEGAPHONE.SDR AALA202104189003Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: CHECK DOOR PRESSURE 1L ILLUMINATED ON CIDS PANEL. SERVICED L1 DOOR ASSIST BOTTLE PRESSURE IAW AMM 52-11-14.SDR GTIA2021041935688Bottle · low pressureDURING WEEKLY R1 DOOR ASSIST BOTTLE FOUND LOW.-SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR R61A2021042900369Pneumatic System · failedR2 DOOR DIDN'T ENGAGE IN KEEPER ASSY WHEN OPENED IN EMERGENCY CONFIGURATION. REPLACED R2 DOOR PNEUMATIC ASSY IAW AMM 52-42-51.SDR UIEA2021041400895Containment Bag · openM/D AFT L/H OVHD BIN RW 40 AVSAX CONTAIMENT BAG VACUUM SEAL BROKEN P/N AS-002-1.(<P>REMOVED AND REPLACED AFT AVSAX CONTAIMENT BAG AS PER B767-300 AMM 25-60-00.</P>)SDR SWAA2021041964490Handle · brokenCAPTAIN'S 'ASSIST HANDLE' BROKEN / REMOVED AND REPLACED PILOT SEAT ASSIST HANDLE PER 56-11-11.SDR SWAA2021041964271Flashlight · inoperative4 OF 6 FLAHSLIGHTS INOP OK TO CONTINUE PER MEL 25-64-02 SP1B TRACK# 108376 ( EMERGENCY FLASHLIGHT HOLDERS/FLASHLIGHTS ) / RESTORED AND PERFORMED OPERATIONAL CHECK OF ALL EMERGENCY FLASHLIGHTS REPLACED BATTERYS IN FLASHLIGHTS STOWED IN FWD JUMPSEAT AND AFT LEFTSDR AALA202104169005Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FOUND R4 DOOR ASSIST CYLINDER LOW PRESSURE. SERVICED R4 DOOR PER AMM 52-10-00.SDR AALA202104169006Girt Bar · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CREW DOOR 832 GIRT BAR ASSEMBLY. REPLACED GIRT BAR.SDR F3LA2021041500032Megaphone · inoperativeDISCREPANCY, LP1239913 ITEM 2: AFT BULL HORN INOP. CORRECTIVE ACTION: REMOVED AND REPLACED AFT MEGAPHONE, OPS TEST GOOD. REF AMM 25-65--51-710-002-A. NOTE 1) THIS WAS FOUND DURING PRE BOARDING FOR FLIGHT 383. NOTE 2) TIME SINCE INSPECTION, IS THE LAST TIME THSDR F3LA2021041500031Megaphone · inoperativeDISCREPANCY, LP1239913 ITEM 1: FWD BULL HORN INOP. CORRECTIVE ACTION: REMOVED AND REPLACED FWD MEGA PHONE BATTERIES, OPS TEST GOOD. REF AMM 25-65-51-970-001-A. NOTE 1 THIS WAS FOUND DURING PRE BOARDING FOR FLIGHT 383. NOTE 2 TIME SINCE INSPECTION, IS THE LASSDR GTIA2021041535687Bottle · low pressureR2 EMERGENCY EXIT DOOR ASSIST BOTTLE REQUIERE SERVICE-SERVICED R2 EMERGENCY EXIT DOOR ASSIST BOTTEL IAW AMM 52-22-00. LEAK CHECK GOOD.SDR GTIA2021041535686Bottle · low pressureL1 DOOR ASSIST BOTTLE REQUIRE SERVICE -SERVICED L1 DOOR ASSIST BOTTLE TO PROPER LEVEL IAW AMM 52-10-00. LEAK CHECK GOODSDR IXXA20210418015Flashlight · not reportedDEFERRAL MAINTENANCE ITEM #21961 INITIATED. AIRCRAFT RELEASED TO SERVICE.REMOVED AND REPLACED THE FORWARD EMERGENCY FLASHLIGHT IAW B767 AMM 25-60-00. THIS CLEARS DEFERRAL MAINTENANCE ITEM 21961. NO FURTHER MAINTENANCE ACTION REQUIRED. AIRCRAFT RELEASED TO SERVSDR U2RA2021041400011Bottle · depletedREFER TO NAL LP 44755-2 AND M-8A ITEM 2, PAGE 1 OF 1: THE L2 DOOR ASSIST BOTTLE WAS FOUND WITH A DEPLETED CHARGE. SERVICED THE L2 DOOR ASSIST BOTTLE AS REQUIRED I/A/W B757 AMM 12-15-10. LEAK CHECKS WERE GOOD - OKAY FOR CONTINUED SERVICE.SDR AALA202104159015Battery · weakAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT FLASH LIGHT AT R4 NEEDS BATTERY CHANGE DUE TO WEAK LIGHT. REMOVED AND REPLACED FLASH LIGHT BATTERY PER AMM 25-65-00.SDR AALA202104159004Battery · weakAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT FLASH LIGHT AT L1 NEEDS BATTERY CHANGE DUE TO WEAK LIGHT. REMOVED AND REPLACED FLASH LIGHT BATTERY PER AMM 25-65-00.SDR AALA202104159003Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FARM REPORTS 1L DOOR ASSIST LOW PRESSURE INDICATION. SERVICED L1 DOOR ASSIST WITH DRY NITROGEN PER AMM 52-40-00.SDR SWAA2021041564119Girt Bar · out of positionL-1 DOOR SLIDE; GIRT BAR; GIRT TOO LONG; NEEDS TO BE REINSTALLED / REPLACED L1 DOOR SLIDE GIRT PER MT725-61-06AMT# 117477INSP# 52251SDR SIMA20210414001Flashlight · missingFOUND EMERGENCY FLASHLIGHT MISSING.-C/A-REPLACED FLASHLIGHT AS REQUIRED PER EMB 175 AMM 33-51-01SDR DALA2021041602236Girt Bar · malfunctionedSHIP 6704 SLIDE LIGHT AT 3R DOOR WILL NOT ILLUMINATE WHEN DOOR IS ARMED. CORRECTIVE ACTION: RE-INSTALLED GIRT BAR SLIDE ARMS NML (7558544)SDR DALA2021041602235Door · malfunctionedSHIP 6802 F/A REPORTS UNABLE TO DISARM 2R DOOR. CORRECTIVE ACTION: DISARMED DOOR NO TROUBLE FOUND CONT IN SERVICE. (7480147)SDR GTIA2021041535685Bottle · low pressureL1 DOOR ASISST BOTTLE REQ SVC-SVCD LI DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR FDEA202104130911Hinge Pin · misalignedCAPTAIN'S ESCAPE LINE(ROPE) COVER WILL NOT OPEN. HINGE PINS APPEAR MISALIGNED REALIGNED PINS AS REQUIRED. AIRCRAFT OKAY FOR SERVICESDR DALA2021041302169Psu · no testSHIP 3245 DURING TEST SEAT 12ABC PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998089)SDR DALA2021041302167Psu · no testSHIP 3245 DURING TEST ROW 27DEF PSU/O2 PANEL DID NOT OPEN. REPACKED MASKS. OK FOR SERVICE. (7660102)SDR DALA2021041302166Psu · no testSHIP 3245 DURING TEST SEAT 32DEF PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7660100)SDR DALA2021041302165Psu · no testSHIP 3245 DURING TEST SEAT 28DEF PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998099)SDR DALA2021041302164Psu · no testSHIP 3245 DURING TEST SEAT ROW 28DEF PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998098)SDR DALA2021041302163Psu · no testSHIP 3245 DURING TEST SEAT 27ABC PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998097)SDR DALA2021041302162Psu · no testSHIP 3245 DURING TEST SEAT 26ABC PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998096)SDR DALA2021041302161Psu · no testSHIP 3245 DURING TEST SEAT 25ABC PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998095)SDR DALA2021041302160Psu · no testSHIP 3245 DURING TEST FOUND SEAT 21DEF PSU/O2 PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (3998094)
Back to JASC 2560