JASC 2560
Service difficulty reports · 40,709
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201812269017Bottle · low pressureL2 DOOR DAMPER CYLINDER HAD LOW PRESSURE. SERVICED L2 DOOR DAMPER BOTTLE IAW AMM 52-22-00.SDR AALA201812269016Cylinder · low pressureL1 DOOR EMERGENCY CYLINDER HAD LOW PRESSURE. SERVICED THE L1 DOOR CYLINDER IAW AMM 52-10-00.SDR IPXA2018122647223Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESSURE LOW.SDR DALA2018122647413Girt Bar · fodSHIP 6806 ENTRY DOOR ARMING LEVER HARD TO OPERATE / LOCATIONS: 1R ARMING LEVER MOVES ONTAKE OFFSLIDE LIGHT GOES OUTON CRUSEARMING LEVERMOVES BACK TO POSIONLIGHT COMES BACKON / INTERIOR. CORRECTIVE ACTION: FOUND DEBRIS ON GIRT BAR COVERS AT 1R DOOR, REMOVED AS SDR DALA2018122647410Holder · unsecureSHIP 689 1R DOOR GRIT BAR HOLDER FELL FROM DOOR NOT SECURED ON DOOR. CORRECTIVE ACTION: RE SECURED GIRT BAR AS REQ IAW AMM 25-66. (5095908)SDR MASA2018122211607Battery Pack · dischargedFWD FA FLASHLIGHT RED LIGHT NOT BLINKING
REPLACED BATTERY.SDR AALA201812269009Flashlight · inoperativeL1 FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT WAS INOPERATIVE. REPLACED THE FLASHLIGHT IAW AMM 25-64-01.SDR GTIA2018122413039Megaphone · inoperativeAFT MEGAPHONE INOP -REMOVED AND REPLACED MEGAPHONE WITH NEW DONE IAW AMM 25-65-51SDR MASA2018122111606Battery Pack · dischargedFWD FA FLASHLIGHT INOP
REPLACED BATTERYSDR MASA2018122111605Battery · inoperativeCA FLASHLIGHT INOP. REPLACED BATTERYSDR MASA2018122111604Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MELSDR AALA201812249005Bottle · low pressureR2 DOOR ASSIST PRESSURE WAS LOW DURING ARMING. SERVICED THE THE DOOR ASSIST BOTTLE IAW MM 52-22-14. SAFETY PINS INSTALLED AND REMOVED.SDR GTIA201812243036Bottle · low pressureR2 DOOR ASSIST + BOTTLE LOW PRESS-SERVICED R 2 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA201812243035Bottle · low pressureR4 DOOR ASSIST NEED SERVICE-SERVICE DOOR TO CORRECIT LIMIT IAW AMM 52-10-00.SDR FDEA2018122103589Indicator · inoperativePDIS 770 52-10 3481 20DEC18 MEM OPEN U LOGPAGES:2923497 WHEN ARMING THE R1 ENTRY DOOR THE "KNUCKLE BUSTER" DOES NOT FULLY DEPLOY. OPEREATED MODE SELECTOR LEVER AND FOUND THE SCREWS HOLDING THE MODE SELECTOR LEVSDR SIMA201812210003Flashlight · inoperativeMEL 25-53 AUTH # 120588-C LG PG 4420629-1 AFT EMERGENCY FLASH LIGHT NOT CHARGING-C/A-PERFORMED FUCTIONAL TEST OF AFT F/A FLASH LIGHT IAW E-140 AMM 33-51-01 AND CHECKS GOOD MEL RESTOREDSDR DALA2018122107327Fitting · looseSHIP 3873 FLIGHT ATTENDANTS REPORT 2R GIRT BAR DOOR FITTING IS LOOSE. CORRECTIVE ACTION: INSPECTED AND FOUND AFT FITTING CLIP HAS LOOSE GRIP FOR BAR SUPPORT. ADJUSTED CLIP FOR CLOSER TOLERANCE TO GRIP FAR. SECURES BAR IN STOW POSTION AS NORMAL. OK FOR SVC. (47SDR QXEA2018122000460Glowstrip · inoperativeGROUND PROXIMITY FLOOR LIGHTING NEAR SEAT 1A INOPERATIVE. REMOVED FROM SERVICE. R&R PHOTOLUMINESCENT INDICATOR STRIP LIGHT AT 1A IAW E175 AMM TASKS 33-50-21-000-801-A AND 33-50-21-400-801-A. OP CK GOOD. RETURNED TO SERVICE.SDR IPXA2018122107101Bottle · low pressureR1 DOOR BOTTLE PRESSURE WAS LOW. SERVICED THE BOTTLE IAW MM 12-25-04SDR IPXA2018122107098Bottle · low pressureR1 DOOR AIR BOTTLE OUT OF GREEN BAND. SERVICED R1 DOOR EMERGENCY DOOR BOTTLE IAW AMM 12-25-04.SDR MASA2018121911601Flashlight · inoperativeCA FLASHLIGHT INOP. REPLACED FLASHLIGHT.SDR MASA2018121911600Battery · dischargedFWD FA FLASHLIGHT INOP. REPLACED BATTERY.SDR AALA201812249004Girt Bar · detachedTHE R1 DOOR GIRT BAR WAS HANGING LOOSE. ATTACHED THE GIRT BAR. OPS CHECKED GOOD.SDR AALA201812209021Battery · dischargedFLASHLIGHTS ON FWD AND AFT JUMP SEAT LOW ON POWER. REPLACED THE BATTERY IAW AMM 25-64-00. OK FOR SERVICE.SDR AALA201812209020Battery · dischargedFLASHLIGHTS ON FWD AND AFT JUMP SEAT LOW ON POWER. REPLACED THE BATTERY IAW AMM 25-64-00. OK FOR SERVICE.SDR GTIA2018122083018Megaphone · malfunctionedZONE M MEGAPHONE DOES NOT SQUEAL WHEN TEST PLUG PULLED OUT-R/R ZONE M MEGAPHONE IAW AC DRAWING NK319-132-EQSDR AALA201812199015Housing · detachedAIRCRAFT WAS NOT GROUNDED: LEFT AFT DOOR EXIT HOUSING WAS COMING OFF. MAINTENANCE REATTACHED LEFT AFT DOOR SLIDE COVER PER AMM 25-61-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR MASA2018121811597Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MEL.SDR SWAA2018122027728Holder · looseR1 DOOR GIRT BAR HOLDER LOOSE. SECURED GIRT BAR CLIP IAW AMM.SDR SWAA2018121827692Strap · corrodedRT EMERGENCY EXIT HATCH ESCAPE STRAP HOOK CORRODED. R&R STRAP PER AMM.SDR SWAA2018121827691Strap · corrodedLT EMERGENCY EXIT HATCH ESCAPE STRAP HOOK CORRODED. R&R STRAP PER AMM.SDR AALA201812199003Bottle · low pressureL2 DOOR HAD A LOW PRESSURE LIGHT DISPLAYED AT THE NR 1 FLIGHT ATTENDANT POSITION. SERVICED THE L2 DOOR ASSIST BOTTLE IAW AMM 52-22-00-614-002-A.SDR AALA201812199002Plug · missingTHE LEFT FORWARD PASSENGER DOOR DAMPER CYLINDER GAUGE WAS MISSING THE FLUID PLUG. REPLACED THE CYLINDER IAW AMM 52-11-14-400-001-B.SDR AALA201812199010Battery · dischargedTHE L4 DOOR FLIGHT ATTENDANT SEAT FLASHLIGHT BATTERY WAS DISCHARGED. REPLACED THE BATTERY IAW AMM 25-64-00.SDR AALA201812199004Battery · dischargedL1 DOOR FLIGHT ATTENDANT SEAT FLASHLIGHT BATTERY DISCHARGED. THE AIRCRAFT WAS GROUNDED. REPLACED THE BATTERY IAW AMM 25-64-00.SDR FDEA201812173527Switch · inoperativeDURING SERVICE CHECK FOUND R1 DOOR SLIDE PTT BUTTON INOP. RELAMPED AND NO HELP. RELEASED FOR SERVICE PER MEL : 25-61-02. REPLACED BATTERIES NO HELP. REMOVED AND REPLACE PTT SWITCH REF AMM 25-61-04. OP CHECKS GOOD.SDR AALA201812189053Cylinder · low pressureR1 CABIN DOOR EMERGENCY OPERATING CYLINDER HAD LOW PRESSURE. MAINTENANCE SERVICED THE CYLINDER IAW AMM 52-10-00, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812189051Battery · inoperativeFLASHLIGHT IN THE AFT CABIN DID NOT WORK. MAINTENANCE REPLACED THE FLASHLIGHT BATTERY IAW MM 25-60-00, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR R61A201812171239Girt Bar · corrodedWHILE ACFT IN HEAVY CHECK MAINT FOUND -MAJOR -AFT SERVICE DOOR LOWER BEAM HAS SURFACE CORROSION AROUND GIRT BAR FITTINGS, REMOVED AND REPLACED R2 DOOR LOWER THRESHOLD BEAM REF EMB SRM 51-40-08,RESTORED SURFACE PROTECTION REF. E175 SRM 51-10-04, 51-10-05, AND 5SDR SWAA2018121827784Glowstrip · looseFORWARD CABIN AISLE CARPET SECTION BETWEEN PHOTOLUMINESCENT STRIP LOOSE BETWEEN ROW 1 TO ROW 4. R&R STRIP PER SIP.SDR SWAA2018121827783Glowstrip · looseLT PHOTOLUMINESCENT STRIP LOOSE BETWEEN SEAT 6 TO SEAT 10. ADJUSTED STRIP PER SIP.SDR AALA201812189046Damper · corrodedALL FOUR PASSENGER AND SERVICE DOOR DAMPERS WERE RUSTED. MAINTENANCE REPLACED THE DAMPERS IAW AMM 52-11-27, 52-41-27, 52-12-27, AND 52-42-27. PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812189045Damper · corrodedALL FOUR PASSENGER AND SERVICE DOOR DAMPERS WERE RUSTED. MAINTENANCE REPLACED THE DAMPERS IAW AMM 52-11-27, 52-41-27, 52-12-27, AND 52-42-27. PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812189044Damper · corrodedALL FOUR PASSENGER AND SERVICE DOOR DAMPERS WERE RUSTED. MAINTENANCE REPLACED THE DAMPERS IAW AMM 52-11-27, 52-41-27, 52-12-27, AND 52-42-27. PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812189039Damper · corrodedALL FOUR PASSENGER AND SERVICE DOOR DAMPERS WERE RUSTED. MAINTENANCE REPLACED THE DAMPERS IAW AMM 52-11-27, 52-41-27, 52-12-27, AND 52-42-27. PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812187001Battery · dischargedWHILE ACCOMPLISHING CC PS CHECK, FOUND THE L1 DOOR EMERGENCY FLASHLIGHT BATTERY DISCHARGED. REPLACED THE FLASHLIGHT BATTERY IAW AMM 25-64-01-960-802, AND PERFORMED A SATISFACTORY OPS CHECK.SDR AALA201812189014Battery · inoperativeEMERGENCY FLASHLIGHT AND HOLDER IN THE MID GALLEY WAS INOPERATIVE. REPLACED THE BATTERY IAW AMM 25-64-00.SDR IPXA2018121766974Indicator · damagedL1 ENTRY DOOR SLIDE DISARM LIGHT DAMAGED. REMOVED AND REPLACED L1 ENTRY DOOR SLIDE DISARM LIGHT INDICATION ASSY IAW SWPM 20-20-01, AND AMM 25-61-15. OPS CHECKED AND FUNCITONAL CHECKED GOOD.SDR GTIA2018121763026Bottle · low pressureR1 PAS DOOR ASSIST BOTTLE LEVEL LOW-SERVICED R1 PAX DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOODSDR MASA2018121611596Battery · dischargedAFT FA FLASHLIGHT INOP. REPLACED BATTERY.
Back to JASC 2560