SDR AALA201811208005Bottle · low pressureR3 DOOR EMERGENCY ACCUMULATOR BOTTLE WAS LOW, 1000 PSI. MAINTENANCE SERVICED THE BOTTLE IAW AMM 52-22-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR SWAA2018111926908Glowstrip · damagedRT PHOTO LUMINESCENT STRIP DAMAGED AT ROW 1. R&R STRIP PER AMM.SDR SWAA2018111926879Battery · dischargedAFT GALLEY FLASHLIGHT INOP. R&R BATTERY PER MM.SDR AALA201811199026Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESSURE WAS LOW. MAINTENANCE SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A.SDR AALA201811199025Flashlight · inoperativeNR 2 FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REPLACED THE FLASHLIGHT IAW AMM 25-65-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201811199023Bottle · low pressureR4 DOOR ASSIST ACTUATOR BOTTLE HAD LOW PRESSURE. MAINTENANCE SERVICED THE R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201811199022Bottle · low pressureR1 DOOR ASSIST ACTUATOR BOTTLE HAD LOW PRESSURE. MAINTENANCE SERVICED THE BOTTLE IAW AMM 52-10-00.SDR AALA201811199015Lever · brokenTHE R3 DOOR ARMING LEVER WAS BROKEN OFF. THE AIRCRAFT WAS GROUNDED. REPLACED THE ARM/DISARM LEVER IAW AMM 52-22-22. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR AALA201811199010Girt Bar · dirtyL2 DOOR HARD TO ARM AND DISARM. CLEANED L2 DOOR GIRT BAR FITTINGS. OPS CHECKED GOOD.SDR AALA201811198001Bottle · low pressureR4 DOOR EMERGENCY ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE.SDR SWAA2018111926850Battery · dischargedAFT GALLEY EMERGENCY FLASHLIGHT INOP. R&R BATTERY IAW AMM.SDR DALA2018111906685Switch · fod(AIRCRAFT 5644, L/P 30 DAY HISTORY) 1R SLIDE LIGHT WILL NOT EXTINGUISH WITH DOOR DISARMED. REMOVED DEBRIS FROM AFT GIRT BAR SWITCH. NOW OPS NML.SDR GTIA2018111962974Bottle · low pressureR1 , R3 , L2 , L4 DOOR ASSIST BOTTLE BELOWLIMIT -SERVICED R1 , R3, L2 & L4 DOOR ASSITBOTTLES IAW AMM 52-10-00. TO PROPER LEVELS. OPS CHECK GOOD.SDR SWAA2018111926919Battery · dischargedFORWARD LT WINDSCREEN LOWER FLASHLIGHT INOP. R&R BATTERY IAW AMM.SDR DALA2018111966684Shoe · not seated(AIRCRAFT 5803, L/P 5012486) 4R DOOR ARMED INDICATIONS INOP. HANDLE JAMMED HALFWAY. RESEATED FWD GIRT BAR SHOE AND PERFORMED OP CK PER B757 AMM 25-66.SDR GTIA2018111952971Bottle · low pressureL-3 DOOR. LOW PRESSURE ON DOOR ASSIST ACCUMULATOR. -SERVICED L-3 DOOR ASSIST ACCUMULATOR AS PER A.M.M. 52-22-00.SDR AALA201811179003Girt Bar · obstructedTHE AIRCRAFT WAS NOT GROUNDED. DOOR 1R ARMING LEVER IS DIFFICULT TO MOVE. REMOVED DEBRIS FROM GIRT BAR AREA. OPERATIONS CHECK NORMAL.SDR AALA201811179002Battery · defectiveTHE AIRCRAFT WAS NOT GROUNDED. BATTERY NEEDS REPLACED ON FORWARD FACING ATTENDANT SEAT FLASHLIGHT. REPLACED BATTERY ON FLASHLIGHT IN FORWARD FACING ATTENDANT SEAT EQUIPMENT COMPARTMENT. OPERATIONS CHECK NORMAL.SDR FDEA2018111653217Girt Bar · out of adjustPDIS 923 52-10 0074 14NOV18 MUC OPEN U LOGPAGES:2711946 L1 DOOR SLIDE ARMED LIGHT INOP. FACT 16NOV18 02:00 CDG PERFORMED ADJUSTEMENT OF THE L1 DOOR GIRT BAR IAW SDR AALA201811169009Flashlight · missingFLASHLIGHT AT THE R2 JUMPSEAT WAS MISSING. REPLACED THE JUMPSEAT FLASHLIGHT.SDR GTIA2018111502961Bottle · low pressureL-3 DOOR. LOW PRESSURE ON DOOR ASSIST ACCUMULATOR. -SERVICED L-3 DOOR ASSIST ACCUMULATOR AS PER A.M.M. 52-22-00.SDR CALA2018111902393Girt Bar · worn(SUPPORT TASK EA 2560-02123 REV D) 2L DOOR GIRT BAR LEAK SPRING FWD AND AFT POSITION FAILED INSPECTION CHECK. REF VTSAA N/R 0028 865.CONTACT UNITED RELIABILITY ENGINEERING FOR FINAL REPAIR INFORMATION IF NEEDED.SDR SWAA2018111526812Glowstrip · damagedAFT LT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111526811Glowstrip · damagedFORWARD LT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111526806Glowstrip · damagedRT PHOTOLUMINESCENT STRIP DAMAGED AT 1ST SECTION. R&R STRIP IAW AMM.SDR SWAA2018111526805Glowstrip · damagedFORWARD RT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111526797Glowstrip · damagedAFT RT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR GTIA2018111542964Megaphone · defectiveMEGAPHONE FWD F/A STATION DEFECTIVE.-R&R MEGAPHONE IAW SPIRIT AIRRAFT DRAWINGS NK320-SPACEFLEX-EQSDR FDEA201811143215Switch · stuckDURING FLIGHT, LEFT SIDE CREW ENTRANCE DOOR SLIDE/RAFT INSIDE LIGHT CAME ON FOR REMAINING OF FLIGHT. FOUND LIGHT SWITCH STUCK IN. REMOVED SWITCH AND READJUSTED SWITCH, OPS CHECKS GOOD.SDR DALA2018111406625Indicator · inoperative(AIRCRAFT 6809, L/P 0825928) DOOR ARMED KNUCKLE KNOCKER INOPERATIVE / LOCATIONS:607 / DISARMED PLACARD LOOSE. / INTERIOR. R/R DISARMED PLACARD ASSY. OPS CHECK NORMAL PER B757 AMM 52-11.SDR MASA2018111411524Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MELSDR AALA201811169012Battery · no testEMERGENCY POWER ASSIST SYSTEM STATUS ON THE R2 DOOR WAS INOPERATIVE, GREEN LIGHT INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY POWER ASSIST SYSTEM BATTERY PACK IAW AMM 52-11-20, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201811159005Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED. FLASHLIGHT AT R1 FLIGHT ATTENDANT SEAT INOPERABLE. REPLACED FLASHLIGHT PER AMM 25-22-00.SDR AALA201811149005Bottle · low pressureR2 DOOR PRESSURE WAS LOW. THE AIRCRAFT WAS GROUNDED. REPLACED THE DOOR DAMPNER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-22-14.SDR AALA201811149003Cylinder · low pressureL4 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. 1200 PSI AT 75 DEGREES F. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201811149002Cylinder · low pressureR4 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. 1500 PSI AT 75 DEGREES F. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR SWAA2018111426766Megaphone · inoperativeAFT MEGAPHONE INOP. R&R MEGAPHONE PER AMM.SDR SWAA2018111426765Girt Bar · out of adjustR1 DOOR GIRT BAR MISALIGNED. ADJUSTED GIRT BAR PER AMM.SDR SWAA2018111326729Glowstrip · damagedAFT LT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111326728Glowstrip · damagedFORWARD LT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111326699Glowstrip · damagedFORWARD RT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR SWAA2018111326698Glowstrip · damagedAFT RT PHOTO LUMINESCENT TRACK LIGHTS DAMAGED. R&R LIGHT PER AMM.SDR FDEA201811133196Switch · brokenPUSH TO TEST SWITCH FOR ESCAPE SLIDE ON L1 DOOR BROKEN. SECURED TEST SWITCH FOR L1 ESCAPE SLIDE. OPS VERIFED NORMALSDR MASA2018111311523Flashlight · inoperativeFO'S FLASHLIGHT INOP. REPLACED FLASHLIGHTSDR IPXA201811145931Cylinder · emptyR1 DOOR PNEUMATIC CYLINDER PRESSURE WAS AT ZERO PSI. COMPLIED WITH A LEAK CHECK IAW AMM 52-11-04-700-801 AND 12-25-04-600-801.SDR AALA201811159015Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED. FORWARD ENTRANCE (1L) EMERGENCY FLASHLIGHT IS DEAD. REPLACED FORWARD EMERGENCY FLASHLIGHT PER AMM 25-65-00.SDR AALA201811159013Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED. 3RD JUMPSEAT ON LEFT FLASHLIGHT INOPERABLE. REPLACED FLASHLIGHT PER MM 33-50-00.SDR AALA201811159001Battery · dischargedAIRCRAFT WAS NOT GROUNDED. L1 DOOR AND FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERIES ARE DEAD. CHANGED BATTERIES IN BOTH EMERGENCY FLASHLIGHTS FOR L1 ATTENDANT STATION PER AMM 25-64-00.SDR AALA201811143002Bottle · leakingEICAS MESSAGE, L1 DOOR EPISODE SQUIB AND DOOR EPISODE SENSORS. REPLACED L1 DOOR EPAS PRESSURE BOTTLE AND PERFORMED SATISFACTORY OPERATIONAL CHECKED IAW AMM 52-11-22.SDR AALA201811149007Cylinder · low pressureL1 DOOR DAMPER CYLINDER PRESSURE WAS LOW. SERVICED THE CYLINDER IAW AMM 52-10-00. LEAK CHECKED GOOD, OK FOR SERVICE.
Back to JASC 2560