JASC 2560
Service difficulty reports · 40,709
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MASA2018090113540Flashlight · inoperativeFWD F/A FLASHLIGHT INOP. PLACED ON MEL.SDR MASA2018090113539Flashlight · inoperativeFO`S FLASHLIGHT INOP. PLACED ON MEL.SDR MASA2018090113538Flashlight · inoperativeFO'S FLASHLIGHT INOP. PLACED ON MEL.SDR F3LA2018090600424Fitting · out of adjustDOOR RT SHOWS DISARMED IN FLIGHT. ADJUSTED R2 GIRTBAR FITTINGS REF AMM 52-13-00-820-057A. PRESSUREIZED AC REF AMM 21-31-00-710-002A. OPS NORMAL OK TO CONTINUE.SDR AALA2018090549031Flashlight · inoperativeFLASHLIGHT AT THE L1 DOOR WAS INOPERATIVE. REPLACED THE FLASHLIGHT IAW AMM 25-65-00.SDR AALA201809049053Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. MAINTENANCE SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201809049029Bottle · low pressureR4 DOOR EMERGENCY ACCUMULATOR BOTTLE HAD LOW PRESSURE. SERVICED THE BOTTLE IAW AMM 52-10-00. OPS AND LEAK CHECKED GOOD.SDR AALA201809049028Cylinder · low pressureL1 DOOR EMERGENCY ACCUMULATOR HAD LOW PRESSURE. SERVICED L1 DOOR CYLINDER IAW AMM 52-10-00. OPS AND LEAK CHECKED GOOD.SDR SWAA2018090424768Fitting · missingL1 DOORWAY FORWARD GIRT BAR BRACKET FITTING MISSING. INSTALLED FITTING PER DWG AND SRM.SDR MASA2018083013536Battery · dischargedFWD FA FLASHLIGHT INOP. REPLACED BATTERY.SDR IPXA2018083193376Mount · brokenFOUND THE EVAS MODULE BROKEN. THE EVAS MOUNT WAS BROKEN. REPLACED THE CAPTAIN`S EVAS MOUNT IAW EO 757-2560-45127H. REINSTALLED THE EVAS UNIT.SDR IPXA2018083103384Switch · brokenL1 DOOR DISARMED LIGHT MODULE BROKEN. REMOVED & REPLACED L1 DOOR DISARMED LIGHT SWITCH MODULE IAW WDM 52-11-01 & OPS CHECKED AMM 52-11-02-410-801 CHECKS ILLEG. EFF SOURCE REF: IPC 52-11-70-01SDR AALA201808319014Cylinder · low pressureR4 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201808319021Damper · low pressureR1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. SERVICED R1 DOOR DAMPER IAW AMM 52-10-00.SDR AALA201808309016Damper · low pressureL2 DOOR DAMPER HAD LOW PRESSURE. SERVICED L2 DOOR DAMPER IAW AMM 52-10-00.SDR AALA201808309007Bottle · low pressureCIDS MESSAGE FOR R4 DOOR CHECK PRESSURE. SERVICED R4 DOOR ASSIST ASSEMBLY IAW AMM 52-10-00.SDR FDEA2018091082212Retaining Clip · missingCREW REPORTED R1 DOOR SLIDE DIFFICULT TO ARM. FOUND R1 DOOR ARMING HANDLE BINDING. OPENING AND CLOSING OF DOOR NORMAL. FOUND GIRT EXTENSION NOT FOLDED CORRECTLY AND HANGING BELOW DOOR. REPOSITIONED GIRT BAR WITH GIRT EXTENSION IAW AMM 25-61-21-04. TESTS NORMALSDR SWAA2018090424736Fitting · crackedR1 DOOR FORWARD GIRT BAR STOWAGE CLIP ATTACHMENT CRACKED. REPAIRED CLIP PER EA.SDR AALA2018083109036Cylinder · low pressureL4 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. MAINTENANCE SERVICED CYLINDER TO PROPER PRESSURE IAW AMM 52-10-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA2018083109035Cylinder · low pressureR3 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. MAINTENANCE SERVICED THE CYLINDER TO PROPER PRESSURE IAW AMM 52-22-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201808319034Cylinder · low pressureL3 DOOR EMERGENCY OPERATION CYLINDER PRESSURE WAS LOW. MAINTENANCE SERVICED THE CYCLINDER IAW AMM 52-22-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201808319001Bottle · low pressureL4 DOOR ASSIST BOTTLE IN YELLOW BAND. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA2018083109019Handle · looseFORWARD SERVICE DOOR ASSIST HANDLE WAS LOOSE. SECURED FORWARD SERVICE DOOR ASSIST HANDLE IAW AMM 52-11-31.SDR AALA201808309032Lens · missingR2 DOOR SLIDE ARMED LIGHT LENS WAS MISSING. MAINTENANCE REPLACED THE LENS AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201808309030Lamp · burned outARM LIGHT AT THE L4 DOOR WAS BURNED OUT. MAINTENANCE REPLACED THE LAMP AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201808309012Cylinder · low pressureL4 DOOR EMERGENCY CYLINDER PRESSURE WAS LOW. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201808299035Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-600-802.SDR MASA2018082813531Battery · inoperativeFWD FA FLASHLIGHT INOPERATIVE. REPLACED THE BATTERY.SDR MASA2018082813529Flashlight · inoperativeFA FLASHLIGHT INOPERATIVE.SDR MASA2018082813528Flashlight · inoperativeFWD FA FLASHLIGHT INOPERATIVE.SDR DALA2018091805646Girt Bar · obstructed4L DOOR DID NOT DISARM ON FIRST TRY. REARMED AND IT DISARMED NORMALLY ON SECOND TRY. REMOVED DEBRIS FROM GIRT BAR ON 4L DOOR. ARM/DISARM CKS GOOD.SDR AALA2018083099030Cylinder · low pressureL2 EMERGENCY EXIT DOOR CYLINDER PRESSURE WAS LOW. MAINTENANCE SERVICED THE CYLINDER IAW AMM 52-22-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR GTIA201808302819Bottle · low pressureDURING A WEEKLY CHECK, FOUND THE R2 DOOR ASSIST BOTTLE BELOW LIMITS. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201808299021Battery · inoperativeFLIGHT ATTENDANT OTBD L1 JUMPSEAT FLASHLIGHT INOPERATIVE. REPLACED THE FLASHLIGHT BATTERY IAW AMM 25-65-00. OPS CHECKED NORMAL.SDR IPXA2018082983309Indicator · brokenL1 DOOR DISARMED LIGHT WAS BROKEN. REPLACED L1 DOOR DISARMED LIGHT IAW WDM 52-11-01. TESTED GOOD.SDR IPXA2018082983308Indicator · brokenR1 DOOR DISARMED LIGHT WAS BROKEN. REPLACED THE DOOR DISARMED LIGHT IAW WDM 52-11-01. TESTED GOOD.SDR SWAA2018082924679Glowstrip · missingLT PHOTOLUMINESCENT STRIP MISSING AT AISLE 1. INSTALLED STRIP PER DWG.SDR AALA201808289009Girt Bar · disengagedR4 DOOR SLIDE LIGHT BURNED OUT. FOUND R4 GIRT BAR NOT ENGAGING PROPERLY. INSTALLED THE GIRT BAR IAW AMM 25-16-10. ACCOMPLISHED REQUIRED CHECKS. SLIDE ENGAGE LIGHT CHECKS NORMAL.SDR AALA201808289021Bottle · defectiveL4 DOOR ASSIST BOTTLE HAD ZERO PSI. REPLACED THE DIAPHRAGM IN THE PERCUSSION MECHANISM OF THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-10-00-610-001-A.SDR AALA201808289006Damper · low pressureL1 ENTRY DOOR ASSIST BOTTLE HAD LOW PRESSURE. REPLACED THE L1 ENTRY DOOR DAMPER IAW AMM 52-11-14.SDR MASA2018082713527Battery · inoperativeFWD FA FLASHLIGHT INOPERATIVE. REPLACED THE BATTERY.SDR MASA2018082763523Flashlight · inoperativeFWD FA FLASHLIGHT WAS INOPERATIVE.SDR GTIA2018082702817Bottle · low pressureL2 DOOR EMERGENCY ASSIST ACTUATOR BOTTLE HAD LOW PRESSURE. SERVICED THE L2 DOOR ASSIST ACTUATOR BOTTLE IAW AMM 52-10-00. ALL CHECKED GOOD.SDR AALA201808299006Bottle · low pressureR4 DOOR ASSIST BOTTL ELOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-22-00.SDR SWAA2018082824635Slide · out of positionR2 DOOR SLIDE GIRT BAR LOOSE. REPOSITIONED SLIDE IAW MT.SDR REXA2018082860718Flashlight · no testFA EMERGENCY FLASHLIGHT BELOW THE SEAT WAS NOT TESTING CORRECTLY. RED LIGHT WAS NOT FLASHING. REMOVED AND REPLACED THE FWD FLASHLIGHT IAW AMM 25-62-02, OPS CHECKED GOOD.SDR DALA2018082805320Girt Bar · dirtyL2 DOOR DOESN'T ARM PAST DEPARTURE TIME. REMOVED DEBRIS FROM GIRT BARS. REMOVED OBSTRUCTION. ALL OPS SATISFACTORY IAW AMM 52-11.SDR GTIA2018082762816Bottle · low pressureDOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED DOOR ASSIST BOTTLE L1 IAW AMM 52-10-00-614-001.SDR MASA2018082613522Battery · inoperativeAFT F/A FLASHLIGHT INOPERATIVE. REPLACED THE BATTERYSDR MASA2018082613521Flashlight · inoperativeFWD FA FLASHLIGHT INOPERATIVE.
Back to JASC 2560