JASC 2560
Service difficulty reports · 40,709
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2018071031563Retaining Clip · brokenINSPECTION TYPE:PS-1, LIFE STOWAGE COMPARTMENT DOOR SUPER SEATS LEFT AND CTR RETAINING CLIPS BROKEN. R&R LIFE VEST STOWAGE COMPARTMENT BETWEEN LEFT AND CTR SUPER SEATS, REF AMM 25-64-01-201.SDR MASA2018071013398Battery · dischargedFWD FA FLASHLIGHT INOP. REPLACE BATTERY.SDR MASA2018071013395Flashlight · inoperativeFWD FA FLASHLIGHT RED LED INOP. PLACED ON MEL.SDR REXA2018071100609Flashlight · inoperativeFWD EMER FLASHLIGHT OUT/INOP. R&R LIGHT IAW AMM 25-61-00. OPS CHECK GOOD.SDR AALA2018071109020Cylinder · low pressureR4 DOOR DAMPER PRESSURE LOW. CHARGED THE DOOR DAMPER IAW AMM 52-22-00. THE AIRCRAFT WAS GROUNDED.SDR WX0A2018071073352Megaphone · inoperativeFOUND AFT MEGAPHONE INOP. R&R AFT MEGAPHONE.SDR MASA2018070913394Flashlight · inoperativeCAPT FLASHLIGHT RED INDICATOR INOP. PLACED ON MEL.SDR SWAA2018071123367Glowstrip · brokenLT AISLE PHOTOLUMINESCENT STRIPS BROKEN BETWEEN ROWS 2 TO ROW 15. R&R STRIP IAW TC.SDR AALA2018071099055Handle · looseL2 DOOR DISARMING LEVER HANDLE IS LOOSE. SECURED THE DOOR DISARMING LEVER HANDLE IAW AMM 52-13-22.SDR AALA201807099043Bottle · low pressureL1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201807099029Girt Bar · lack of lubeL2 DOOR 2L IS DIFFICULT TO ARM & DISARM. LUBRICATED THE GIRT BAR. OPS CHECKED GOOD, OK FOR SERVICE.SDR AALA201807099041Bottle · low pressureR3 EMERGENCY EXIT DAMPER BOTTLE PRESSURE LOW. SERVICED THE BOTTLE IAW AMM 52-10-00-614-001-A.SDR AALA201807099039Bottle · low pressureR4 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE BOTTLE IAW AMM 52-22-00-614-002-A.SDR MASA2018070813390Flashlight · inoperativeAFT FA FLASHLIGHT INOP. PLACED ON MEL.SDR MASA2018070813389Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MEL.SDR AALA2018071109019Cylinder · low pressureR4 DOOR EMERGENCY CYLINDER PRESSURE WAS LOW. SERVICED EMERGENCY CYLINDER IAW AMM 52-10-00.SDR AALA2018071109014Lever · looseR2 DOOR ARMING LEVER LOOSE. SECURED THE ARMING LEVER.SDR AALA2018071099052Bottle · low pressureCIDS FOR CHECK R2 DOOR PRESSURE MESSAGE. SERVICED THE DOOR ASSIST BOTTLE IAW 52-10-00.SDR AALA201807099044Bottle · low pressureR4 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-22-14. NO LEAKS DETECTED.SDR AALA201807099037Cover · missingL1 DOOR ASSIST HANDLE COVER MISSING. REPLACED THE HANDLE COVER IAW AMM 52-10-00. OK FOR SERVICE.SDR REXA2018070600612Knob · missingMEGAPHONE VOLUME KNOB MISSING. REMOVED AND REPLACED MEGAPHONE IAW AMM 25-61-14. PERFORMED OPS TEST. OPS TEST GOOD. A/C OK FOR SVC.SDR AALA2018071099049Girt Bar · fodR2 DOOR WILL NOT ARM. REMOVED DEBRIS FROM THE DOOR GIRT BAR. OPS CHECKED OK IAW AMM 52-70-00.SDR AALA2018071099048Girt Bar · lack of lubeR2 DOOR ARMING LEVER GRINDS WHEN OPERATED. CLEANED & LUBRICATED THE GIRT BAR HOOKS. OPS CHECKED GOOD IAW AMM 25-62-00.SDR SIMA201807081004Flashlight · odorSTRONG SULFUR SMELL IN CABIN AND ALSO COCKPIT BURNS THE EYES BOTH ENGINE AND PACK ON. PERFORMED GVI FWD AVIONICS AFT BAY NO FINDINGS INSPECTED CABIN AND FOUND ALL FLASHLIGHTS BURNT SMELL LIKE SULFUR. RAN APU PACKS AND BLEEDS NO SMELL NOTED CREW RAN ENGINES NO SDR AALA201807099036Flashlight · inoperativeAFT FLIGHT ATTENDANT FLASHLIGHT WAS INOPERATIVE. ADJUSTED AND FIXED THE AFT FLASHLIGHT IAW AMM 25-60-00. OPS CHECKED OK.SDR MASA2018070613388Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MEL.SDR DALA2018071304473Lanyard · out of position1R DOOR LANYARD STUCK IN GIRT BAR. FREED LANYARD AND RESECURED.SDR AALA2018071099047Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESSURE WAS AT 650 PSI, AT 90F. SERVICED THE BOTTLE IAW AMM 52-10-00.SDR AALA2018070969020Cylinder · low pressureR4 DOOR DAMPER EMERGENCY OPERATION CYLINDER AT 1400 PSI AT 79 DEGREES F. SERVICED THE CYLINDER IAW AMM 52-10-00-614-001-A.SDR AALA2018070969019Pin · frozenFOUND THE RIGHT AFT EMERGENCY EXIT HATCH DISARM PIN FROZEN. REPLACED THE SLIDE RELEASE PIN MECHANISM IAW AMM 52-21-11.SDR FDEA201807051631Lock · lack of lubeR1 DOOR GIRT BAR ESCAPE SLIDE ENGAGEMENT ARM LIGHT WILL NOT ILLUMINATE. REMOVED GIRT BAR LOCKS, CLEANED AND LUBED LOCKS AND FLOOR FITTINGS. REINSTALLED GIRT BAR LOCKS AND ENGAGED GIRT BAR ASSY. R1 DOOR SLIDE ARMS NORMAL WITH NORMAL INDICATION. REF MM 25-66-01SDR HNAA2018070600142Battery · malfunctionedSMOKE ODOR IN PLANE, WHEN RECIRC FAN TURNED OFF, SMELL WENT AWAY. OPS CHECK RECIRC FAN WITH NO DEFECTS NOTED. INSP CABIN & FOUND AFT CABIN FLASHLIGHT BATTERIES VERY HOT WITH STRONG SULFUR ODOR. REPLACED AFT FLASHLIGHT & BATTERIES. REPLACED F/A AND CAPTAINS FLASDR IPXA2018070631418Mount · brokenF/O'S EVAS MOUNT HAS BROKEN FROM A/C. REINSTALLED MOUNT FOR FO'S EVAS REF EO B757-2560-45127-H.SDR REXA2018070600596Seal · brokenAFT PBE SEAL BROKEN. INSTALLED AFT PBE SEAL AS REQUIRED. A/C OK FOR SVC.SDR AALA201807069017Girt Bar · out of adjustR4 DOOR LT GIRT BAR ATTACHED SHOWS RED WHEN ARMED. ADJUSTED GIRT BAR, OPS CHECKED GOOD IAW AMM 52-11-25-825-001.SDR AALA201807106004Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESSURE WAS 1,650 PSI AT 90F. SERVICED THE BOTTLE IAW AMM 52-10-00.SDR AALA201807096005Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESSURE WAS 1,700 PSI AT 90F. MAINTENANCE SERVICED THE BOTTLE IAW AMM 52-10-00, AND PERFORMED A SATISFACTORY OPS CHECK.SDR AALA201807096003Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESSURE WAS 1,700 PSI, AT 90 DEGREES FARENHEIT. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201807096002Bottle · low pressureL1 DOOR ASSIST BOTTLE PRESSURE WAS 650 PSI AT 90F. SERVICED THE BOTTLE IAW AMM 52-10-00.SDR SWAA2018070423309Glowstrip · damagedLT PHOTOLUMINESCENT STRIP DAMAGED AT 1ST SECTION. R&R STRIP IAW AMM.SDR AALA201807099026Battery Pack · failedL1 PASSENGER DOOR EMERGENCY POWER ASSIST SYSTEM, BATTERY FAILED. REPLACED DOOR ASSIST BATTERY PACK IAW AMM 52-11-20. CHECKED GOOD, OK FOR SERVICE.SDR DALA2018070604393Girt Bar · out of adjustDOOR 1R SLIDE/ GIRT BAR NEEDS ATTENTION FOR REQUIREMENT TO STOW GIRT BAR IN DOOR. READJUSTED GIRT BAR. OPS NML. OK FOR SERVICE.SDR AALA2018070659018Bottle · low pressureR3 OVERWING DOOR ASSIST BOTTLE BELOW LIMITS. SERVICED THE R3 OVERWING DOOR ASSIST BOTTLE IAW AMM 52-20-00.SDR AALA201807063029Bottle · low pressureR3 OVERWING DOOR ASSIST BOTTLE BELOW GREEN BAND. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-20-00.SDR AALA20180703013Support · brokenAIRCRAFT WAS NOT GROUNDED. FLASHLIGHT ASSEMBLY SUPPORT AT DOOR 1L BROKEN. REPLACED FLASHLIGHT ASSEMBLY AT DOOR 1L, CHECKED OK PER AMM 25-64-00. OPERATIONAL TEST OK PER AMM 25-64-01.SDR IPXA2018070531405Pin · defectiveR1 DOOR EVAC SLIDE UPPER MOUNT PINS DO NOT LOCK REF IPC 25-61-05-01 ITEM 035. R&R R1 DOOR EVAC SLIDE UPPER MOUNT PINS WITH REF TO MM 25-61-15.SDR MASA2018070312380Flashlight · inoperativeFWD FA FLASHLIGHT INOP. PLACED ON MEL.SDR MASA2018070312379Flashlight · inoperativeFWD FA'S FLASHLIGHT INOP. PLACED ON MEL.SDR DALA2018070304407Latch · obstructed1R DOOR WOULD NOT ARM. REMOVED DEBRIS FROM GIRT BAR LATCHES. OPS CHKS NML. OPS CHK NML.SDR DALA2018070304402Girt Bar · obstructed1R DOOR ARMED LIGHT WILL NOT COME ON WHEN DOOR IS ARMED. FOUND DEBRIS STUCK BY 1R DOOR GIRT BAR REMOVED DEBRIS. ALL CHKS NORMAL. REF AMM 25-66.
Back to JASC 2560