JASC 2560
Service difficulty reports · 40,741
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2016080554573Battery Pack · dischargedAFT CABIN INBD ON RT SIDE EMERGENCY FLASHLIGHT INOPERATIVE. R & R BATTERY PACK IAW AMM.SDR SWAA2016080854624Fitting · brokenR2 DOOR EMERGENCY EVACUATION SLIDE AFT GIRT BAR FITTING NUT PLATE BROKEN. R & R FITTING IAW SRM.SDR SWAA2016080554583Cover · looseL2 DOOR EMERGENCY EVAC SLIDE MANUAL HANDLE COVER LOOSE. SECURED COVER IAW SIP.SDR SWAA2016080454516Strap · out of adjustLEFT EMERGENCY EXIT ESCAPE STRAP OUT OF ADJUST. ADJUSTED STRAP IAW AMM.SDR DALA2016080305864Girt Bar · dislodgedFOUND R4 DOOR SLIDE GIRT BAR DISLOGED FROM SLIDE ASSY. PINNED INFLATOR BOTTLE AND REINSTALLED R4 SLIDE GIRT BAR MECHANISM IAW AMM 25-61. REMOVED PIN FROM INFLATOR BOTTLE. OK FOR SERVICE. MECHANISM ARM WITHOUT FAULT.SDR ASOA2016080215158Megaphone · damagedMEGAPHONE BATTERY HOLDER MELTED. REMOVED AND REPLACED THE MEGAPHONE IAW AMM 25-61-14. REF IPC 25-61-14, FIG 1, ITEM 5.SDR SWAA2016080254476Battery · dischargedRT EMERGENCY FLASHLIGHT BATTERIES INOPERATIVE. R & R BATTERIES IAW AMM.SDR SWAA2016080254474Battery · dischargedLEFT EMERGENCY FLASHLIGHT BATTERIES INOPERATIVE. R & R BATTERIES IAW AMM.SDR ASOA2016080115157Megaphone · inoperativeMEGAPHONE INOPERATIVE. R & R MEGAPHONE IAW AMM 25-61-14, REF IPC 25-61-14, FIG 1, ITEM 5.SDR AALA201608029006Fitting · out of adjustR2 DOOR DISARMS INFLIGHT BY ITSELF. AIRCRAFT GROUNDED. ADJUSTED R2 DOOR GIRT BAR FITTING CLEARANCE IAW AMM 52-13-22 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201608029003Escape Rope · frayedRIGHT OVERWING ESCAPE LIFE LINE ROPE ASSEMBLY FRAYING NEAR END. REPLACED ESCAPE ROPE ASSEMBLY.SDR IPXA2016080206599Evas Unit · detachedINSPECTION TYPE:ON COCKPIT PREFLIGHT NOTICED CAPTS EVAS LAYING SIDEWAYS, NOT ATTACHED TO ANYTHING. REMOVED CAPTAINS EVAS UNIT FROM AIRCRAFT. INSTALLED CAPTAIN'S EVAS BRACKET ASSY KIT PN 6303-3 IAW DWQ VSC 6307, SHEET NR 7 & NR 12, MC 0986317, INSTALLED LT EVASDR UIEA2016080100655Mask · damagedMAIN CABIN R4 PBE DAMAGED. REMOVED AND REPLACED PBE MASK IAW AMM 25-60-00.SDR UIEA2016080100659Escape Rope · brokenTWO EMERGENCY DEVICES BROKEN, EMERGENCY DECENT DEVICES REPLACED IAW AMM 25-61-03.SDR FDEA201607312695Proximity Sensor · dirtyL1 DOOR SLIDE LIGHT INOPERATIVE WITH DOOR CLOSED AND SLIDE ARMED. CLEANED SMALL AMOUNT OF DEBRIS FROM GIRT BAR PROXIMITY SWITCHES, CYCLED DOOR ARMING LEVER MANY TIMES, L1 LIGHT OPS CHECKED NORMAL IAW MM 25-66-00-0-0.SDR SIMA20160731002Flashlight · brokenF/O FLASHLIGHT ON/OFF SWITCH BROKEN, REPLACED F/O FLASHLIGHT IAW AMM TASK 33-50-16. OPS CHECK GOOD.SDR C77A20160803002Flashlight · inoperativeCAPTAIN`S FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED THE FLASHLIGHT ASSY IAW AMM. OPS CHECKED GOOD.SDR AALA201607319005Battery · dischargedEMERGENCY FLASHLIGHT UNDER FORWARD FLIGHT ATTENDANT SEAT INOPERATIVE. REPLACED THE BATTERY AND ACCOMPLISHED A SATISFACTORY OPS CHECK.SDR MASA2016073012886Flashlight · inoperativeCAPTAINS FLASHLIGHT INOPERATIVE.SDR SWAA2016090955647Girt Bar · damagedL1 DOOR ESCAPE SLIDE GIRT BAR STOP DAMAGED. R & R GIRT BAR IAW AMM.SDR SWAA2016090955646Retainer · damagedL1 DOOR ESCAPE SLIDE COVER AFT GIRT BAR RETAINER FASTENER DAMAGED. R & R RETAINER ASSY IAW SRM.SDR SWAA2016090955645Latch · damagedL2 DOOR ESCAPE SLIDE LATCH BLOCK ASSY DAMAGED. R & R LATCH ASSEMBLY IAW SRM.SDR SWAA2016090855620Strap · inoperativeLEFT EMERGENCY EXIT HATCH ESCAPE STRAP INOPERATIVE. R & R THE STRAP IAW AMM.SDR SWAA2016090855619Strap · inoperativeRIGHT EMERGENCY EXIT HATCH ESCAPE STRAP INOPERATIVE. R & R THE STRAP IAW AMM.SDR SWAA2016082254974Retainer · looseL1 DOOR GIRT BAR AFT RETAINER LOOSE. R & R THE RETAINER ASSEMBLY IAW SRM.SDR SWAA2016080254416Bracket · looseR1 DOOR EMERGENCY SLIDE GIRT BAR AFT BRACKET LOOSE. SECURED THE GIRT BAR HOLDER IAW SIP.SDR GTIA2016072901522Flashlight · inoperativeCAPTAIN`S EMERGENCY FLASHLIGHT INOPERATIVE. R & R CAPTAIN`S EMERGENCY FLASHLIGHT IAW OPERATOR`S EMERGENCY EQUIPMENT DWG NK320-232EQ.SDR AALA201607309004Girt Bar · obstructedR4 DOOR WILL NOT ARM. REMOVED DEBRIS FROM FORWARD SIDE OF GIRT BAR HOLD DOWN POINT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK OF THE DOOR ARMING SYSTEM.SDR SIMA20160729005Flashlight · inoperativeFORWARD F/A FLASHLIGHT NOT CHARGING. R & R FOWARD F/A FLASHLIGHT IAW AMM 33-50-16.SDR VQIA201607290027Pin · wornUNABLE TO ARM L1 DOOR. DURING INSPECTION, FOUND BUSHING AND PIN ASSY WORN ON GIRT BAR FORWARD TELESCOPING MOUNT FORK. R & R BUSHING AND PIN ASSY IAW AMM 52-11-22, SUBTASK 52-11-22-420-050-A. NO FURTHER DEFECTS NOTED.SDR R61A201607280446Flashlight · inoperativeCREW REPORTED THAT THE CAPTAINS FLASHLIGHT WAS NOT CHARGING. REMOVED AND REPLACED THE FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR R61A201607280441Flashlight · inoperativeMAINTENANCE REPORTED THAT THE FORWARD F/A FLASHLIGHT WAS INOPERATIVE. MAINTENANCE R & R FORWARD F/A FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR MASA2016072812883Flashlight · inoperativeFWD FA FLASHLIGHT INOPERATIVE.SDR AALA201607279010Lever · broken3L DOOR ARMING LEVER BROKEN OFF. AIRCRAFT GROUNDED. REPLACED L3 DOOR ARM - DISARM LEVER IAW AMM 52-22-22-400-001-A AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR R61A201607250431Battery Pack · inoperativeMAINTENANCE REPORTED THAT THE FLIGHT ATTENDANT SPARE FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED SPARE FLASHLIGHT BATTERY IAW AMM AND OPS CHECKED GOOD.SDR UHLA201607250370Girt Bar · stuckL1 DOOR WON'T ARM. GIRT BAR STUCK. INSPECTED AND FOUND L1 DOOR GIRT BAR NOT SNAPPED IN PLACE. RESECURED GIRT BAR IAW MM 52-11-41 AND NO DEFECTS NOTED. CHECKS GOOD IAW MM 52-11-20.SDR MASA2016072512880Flashlight · inoperativeFWD FA FLASHLIGHT NOT BLINKING.SDR RAIA201607240001Cradle · inoperativeAFT FA FLASHLIGHT HOLDER NOT CHARGING THE FLASHLIGHT.SDR R61A201607240430Flashlight · inoperativeCREW REPORTED THAT THE FORWARD FLIGHT ATTENDANT FLASHLIGHT WAS INOPERATIVE. MAINTENANCE PERFORMED OPS CHECK OF FORWARD FLIGHT ATTENDANT FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR MASA2016072412877Battery Pack · inoperativeEMERGENCY FLASHLIGHT INOPERATIVE. REPLACED BATTERY.SDR ASOA2016072315133Battery Pack · dischargedFA FLASHLIGHT INOPERATIVE. REPLACED THE BATTERIES AND OPS CHECKED GOOD IAW AMM 25-61-04. ACFT OK FOR SERVICE.SDR R61A201607230429Flashlight · intermittentCREW REPORTED THAT THE CAPTAIN`S FLASHLIGHT WAS WORKING INTERMITTENTLY. MAINTENANCE REMOVED AND REPLACED CAPTAINS FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR R61A201607230428Flashlight · missingCREW REPORTED THAT THE FIRST OFFICERS FLASHLIGHT WAS MISSING. MAINTENANCE INSTALLED A NEW FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.SDR QXEA2016072200461Escape Rope · unsecureEMERGENCY ROPE PROTRUDING FROM THE DITCHING DAM ON THE RIGHT FORWARD EMERGENCY EXIT DOOR. SECURED THE ROPE. NO DEFECTS NOTED. RETURNED TO SERVICE.SDR AALA201607259020Battery · dischargedBOTH FLASHLIGHTS DO NOT FLASH AT FORWARD FLIGHT ATTENDANT JUMP SEAT. REPLACED THE BATTERIES ON BOTH FLASHLIGHTS DO NOT FLASH AT FORWARD FLIGHT ATTENDANT JUMP SEAT IAW AMM 25-65-00.SDR IPXA2016072206162Pbe · unserviceablePBE HAS LOST VACUUM PACK. R & R PBE IAW AMM 25-64-00-902-041.SDR MASA2016072212876Battery · inoperativeFWD FA FLASHLIGHT DOES NOT CHARGE. REPLACED THE BATTERYSDR AALA201607229004Bushing · damagedR2 DOOR AFT GIRT BAR MECHANISM LINK HAS A DAMAGED SPACER ON TORSION SPRING ASSEMBLY. REPLACED SPRING ASSEMBLY AND ADJUSTED GIRT BAR MECHANISM LINK PER AMM 20-11-00-912 AND TASK CARD 19C84252007.SDR MASA2016072112875Flashlight · inoperativeAFT ATT FLASHLIGHT INOPERATIVE.SDR UIEA2016072100618Control Panel · no testFOUND ELT CONTROL PANEL FUNCTIONAL CHECKED FAILED. REPLACED THE ELT CONTROL PANEL AND PERFORMED ELT TEST THE RESULT WAS SATISFACTORY IAW AMM 23-24-01.
Back to JASC 2560