JASC 2560
Service difficulty reports · 40,741
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA00407Battery · faultyFLASHLIGHT DOOR 2L INOPERATIVE. FOUND FAULTY BATTERY. REPLACED ENTIRE FLASHLIGHT ASSY, OPS CHECKED NORMAL.SDR 2008UALA00362Girt Bar · obstructed1R WILL NOT ARM. DEBRIS UNDER GIRT BAR FITTINGS. CLEANED DEBRIS FROM GIRT BAR AREA ON FLOOR. DOOR ARMS AND DISARMS NORMALLY.SDR UPS08B51481Inertia Reel · dislodgedINERTIAL REELS FELL OUT OF UNIT ON LANDING. NEED TO BE CHECKED FOR CORRECT STOWAGE. INSPECTED AND REPLACED ALL DESCENT DEVICES PER AMM 25-61-01-2.SDR SWAA080391Glowstrip · looseEEPLS PHOTOLUMINESCENT STRIP LOOSE AT ROW 8 ABC. REMOVED AND REPLACED STRIP PER MM.SDR 2008UALA00332Panel · shortedEVACUATION COMMAND - SIGNAL IN COCKPIT OVERHEAD PNL HAS DARK AREAS. ELECTRICAL SHORTING ON PANEL ITSELF. REPLACED COCKPIT EVAC PANEL, NORMAL OPERATION.SDR AALA200800087Strap · missingORD - EMERGENCY FLASHLIGHT IN CABIN MISSING STRAP. REPLACED STRAP FOR EMERGENCY FLASHLIGHT IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR UPS08851495Girt Bar · dirtyGIRT BAR JAMS ON RIGHT SIDE. CLEANED DEBRIS FROM GIRT BAR FLOOR LATCH AND LUBED. OPS CHECKS GOOD.SDR AALA200800084Flashlight · inoperativeLGA - EMERGENCY FLASHLIGHT IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY FLASHLIGHT IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR MASA200800025Cable Assy · missingASH FLT 7281 IAD. FWD F/A FIRE EXTINGUISHER MISSING BREAK AWAY CABLE. MX INSTALLED BREAK AWAY CABLE.SDR TRAX200800096Sign · missingEXIT SIGN MISSING AFT OF SVC DOOR. FLT 4425 DEL 42 MINS.SDR 2008UALA00289Girt Bar · looseFORWARD ENTRY DOOR EMERGENCY SLIDE GIRT BAR FLOOR ATTACH FITTING SCREWS LOOSE. SECURED GIRT BAR FLOOR ATTACHMENT FITTING.SDR SWAA080327Hook · looseDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED HOOK PER MM.SDR 2008UALA00272Link Assy · dirtyNR 2 LEFT MED, AFT DEPLOYMENT BAR LINK ASSY IS STIFF. CLEANED GIRT BAR. DRY LUBRICATED ASSEMBLY. REASSEMBLED AND OPS CHECKED. ACFT OK FOR SERVICE.
SDR SWAA080314Hook · brokenR1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK BROKEN. REMOVED AND REPLACED HOOK PER MM.SDR SWAA080300Fitting · looseR1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING LOOSE. SECURED FITTING PER SRM.SDR AALA200800058Flashlight · inoperativeLGA - EMERGENCY FLASHLIGHT AT AFT GALLEY CHARGE LIGHT INOPERATIVE. REPLACED EMERGENCY FLASHLIGHT AT AFT GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2008UALA00217Smoke Goggles · inoperativeF/O GOGGLES INOPERATIVE. SUSPECT BROKEN FROM PRE-FLIGHT CHECKS. REPLACED SMOKE GOGGLES. ACFT OK FOR SERVICE.SDR SWAA080246Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR SWAA080245Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR SWAA080244Battery · dischargedAFT CABIN EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PER MM.SDR 2008UALA00162Battery · dischargedBOTH FWD EMERGENCY FLASHLIGHTS DEAD. REPLACED BOTH BATTERIES. OPS CHECKED NORMAL.SDR TRAX200800063Glowstrip · missingPAX COMPARTMENT RIGHT SIDE OVERWING AFT EMERGENCY TRACK LIGHTING PHOTOLUMINESENT STRIP IS MISSING.SDR SWAA080218Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT RT BS 747 TO RT BS 827. REMOVED AND REPLACED STRIP PER MM.SDR SWAA080217Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT RT BS 520 TO RT BS 540. REMOVED AND REPLACED STRIP PER MM.SDR SWAA080216Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT RT BS 400 TO RT BS 440. REMOVED AND REPLACED STRIP PER MM.SDR SWAA080215Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT LT BS 639 TO LT BS 706. REMOVED AND REPLACED STRIP PER MM.SDR SWAA080213Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT LT BS 344 TO LT BS 440. REMOVED AND REPLACED STRIP PER MM.SDR SWAA080214Glowstrip · delaminatedDURING SCHEDULED 14Y CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT LT BS 520 TO LT BS 540. REMOVED AND REPLACED STRIP PER MM.SDR 2008UALA00170Battery · inoperativeEMERGENCY FLASHLIGHT AT DOOR 2 LEFT DOESN'T FLASH. FOUND BATTERY FAILED.
REPLACED BATTERY, OPS CHECKED OK.SDR TRAX200800060Flashlight · inoperativeF/A FLASHLIGHT INOP.SDR F3LA200800019Battery · inoperativeDURING C CHECK INSPECTION, THE FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY WAS FOUND DEAD. MAINTENANCE REMOVED AND REPLACED THE FLASHLIGHT BATTERY IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 25-65-00. UPON COMPLETION OF THE BATTERY REPLACEMENT, THE SDR SWAA080171Fitting · crackedDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CRACKED. REMOVED AND REPLACED FITTING PER MM.SDR SWAA080145Fitting · corrodedDURING SCHEDULED 16Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR SWAA080144Fitting · corrodedDURING SCHEDULED 16Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR AALA200800032Flashlight · inoperativeDFW - EMERGENCY FLASHLIGHT AT FIRST CLASS FLIGHT ATTENDANT STATION INOPERATIVE. REPLACED FLASHLIGHT AT FIRST CLASS FLIGHT ATTENDANT STATION. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AMTA200800009Glowstrip · unserviceableF/A`S REPORT EGRESS LIGHTING BY RT AFT LAV IS INOPERATIVE. REMOVED AND REPLACED WITH SERVICEABLE PHOTOLUMINESCENT STRIP AT RT AFT LAV IAW AMM 33-51-15. (K)SDR SWAA080148Battery · dischargedFWD CABIN EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PER MM.SDR UPS08M51379Sign · brokenINSPECTION TYPE:N/A EMERGENCY EXIT SIGN BROKEN. REINSTALLED EMERGENCY EXIT SIGN.SDR AALA200800029Strap · brokenLGA - EMERGENCY FLASHLIGHT AT AFT RIGHT AFT POSITION HAS BROKEN STRAP. REPLACED STRAP FOR EMERGENCY FLASHLIGHT AT AFT RIGHT AFT POSITION.SDR AALA200800028Strap · missingLGA - EMERGENCY FLASHLIGHT AT AFT RIGHT FORWARD POSITION MISSING STRAP. REPLACED STRAP FOR EMERGENCY FLASHLIGHT AT AFT RIGHT FORWARD POSITION. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2008UALA00043Girt Bar · obstructedFOUND STATIC LINE OUT OF POCKET INTERFERING WITH GIRT BAR AND DOOR SEAL. FLT ATT STUFFED PAPER TOWELS UNDER SLIDE COVER AND JAMMED SLIDE BUSTLE LOOSE. AFTER REMOVAL OF COVER FOUND DOOR WOULD NOT ARM. FOUND STATIC LINE OUT OF POCKET INTERFERING WITH GIRT BARSDR 2008UALA00063Battery · inoperativeFLASHLIGHT AT 2L POWER LIGHT INOPERATIVE. BATTERY FAILED. REPLACED FLASHLIGHT BATTERY.SDR SWAA080107Battery · dischargedFWD CABIN EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PER MM.SDR 2008UALA00042Girt Bar · obstructedSLIDE LT DOOR 2R INOPERATIVE. *S/D* GIRT BAR NOT ENGAGING FULLY DUE TO DEBRIS. CLEANED GIRT BAR FITTINGS AND DOOR ARMING SYSTEM OPERATES NORMALLY.SDR MASA200800006Glowstrip · inoperativeASH FLT 2834 (INBOUND) TUS - EXIT PATH STRIP PHOTO ILLUM IN EXIT ROW INOP. REMOVED AND REPLACED LIGHT STRIP.SDR UPS08851362Attach Fitting · missingINSPECTION TYPE:N/A AFT GIRT BAR FITTING FOR ESCAPE SLIDE MISSING. DEFERRED ESCAPE SLIDE IAW DC8 MEL 52-7-4. D366115 ASSIGNED. LOCATED AND INSTALLED MISSING ATTACH FITTING AND HARDWARE. OPS CHECK OK. THIS CLEARS DMI.SDR 2008UALA00017Battery · weakF/A REPORTED DR 3L EMERGENCY FLASHLIGHT BATTERY WEAK. SUPPLEMENTAL DATA UPDATE SUSPECT BATTERY IN DISCHARGED CONDITION. REPLACED FLASHLIGHT BATTERY. AC OK FOR SERVICE.SDR 2008UALA0017Battery · weakF/A REPORTED DOOR 3L EMERGENCY FLASHLIGHT BATTERY WEAK.SDR TRAX200800012Pbe · unserviceablePBE BEHIND CAPTAIN LOST VACUUM.SDR UPS07151350Pbe · damagedPS1 PBE NO LONGER VACUUM SEALED. REPLACED PBE WITH SERVICEABLE UNIT.
Back to JASC 2560