JASC 2560
Service difficulty reports · 40,741
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR BJNA050203Battery Pack · dischargedCABIN EMERGENCY FLASHLIGHT CHARGE INDICATOR DOES NOT BLINK. REMOVED AND REPLACED THE FLASHLIGHT BATTERY PACK IAW AMM 25-69-00. (M)SDR SWAA050586Flashlight · crackedDURING SCHEDULED SERVICE CHECK, FOUND 1 EA EMERGENCY FLASHLIGHT CRACKED AT AFT CABIN. REMOVED AND REPLACED EMERGENCY FLASHLIGHT PER MM.SDR SWAA050585Battery · inoperativeDURING SCHEDULED SERVICE CHECK, FOUND 2 EA CABIN EMERGENCY FLASHLIGHTS INOP AT FWD AND AFT CABIN. REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERIES PER MM.SDR AWXA200500258Battery · dischargedPHX - EMERGENCY EQUIPMENT, FLIGHT CREW REPORTED THE EMERGENCY FLASHLIGHT OVER THE FORWARD FLIGHT ATTENDANT JUMPSEAT IS NOT INDICATING A CHARGE LIGHT. MAINTENANCE REMOVED AND REPLACED FORWARD EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR UPS05643918Smoke Goggles · crackedINSPECTION TYPE:N/A, F/O SMOKE GOGGLES CRACKED. INSTALLED NEW SET OF SMOKE GOGGLES.SDR DHL2005780001Cover · crackedF/O ESCAPE ROPE HATCH WILL NOT STAY CLOSED DUE TO A CRACK IN PLASTIC CASING. REPAIRED CRACK IN CASING IAW B-M/M 25-00-11, OPS CHECK GOOD.SDR UPS05143927Girt Bar · twistedINSPECTION TYPE:N/A UNABLE TO DISARM ENTRY DOOR SLIDE. HANDLE WILL TRAVEL APPROX 3/4 AFT. ECAM INDICATION REMAINS AS SLIDE ARMED. FOUND GIRT BAR SKIRT TWISTED AND BINDING RELEASE MECH. ADJUSTED SKIRT, OPS CK NORMAL PER MM 25-61-21-4.SDR SWAA050494Battery · inoperativeDURING SCHEDULED RON, FOUND FWD EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT BATTERY PER MM.SDR UPS05M43912Smoke Goggles · crackedJUMP SEAT AREA RIGHT SIDE SMOKE GOGGLES NEED REPLACED LENS CRACKED. REPLACED SMOKE GOGGLES.SDR UPS05143910Limit Switch · inoperativeESCAPE SLIDE DOES NOT ARM ONLY AFTER NUMEROUS TRIES. REMOVED AND REPLACED LIMIT SWITCH 13WN IAW MM 52-73-13-4, OPS CK.SDR UPS05543911Smoke Goggles · inoperativeSMOKE GOGGLES MISSING UNDER JUMPSEAT. INSTALLED SERV SMOKE GOGGLES.SDR AALA20050152Cable · defectiveTUL - RIGHT NUMBER ONE PASSENGER DOOR GIRT BAR FAILED TO DISENGAGE WHEN DOOR WAS ARMED THEN OPENED FROM THE OUTSIDE. DISARM CABLE WAS ADJUSTED TO THE MAXIMUM POSITION AND STILL WOULD NOT DISARM GIRT BAR. REPLACED DISARM CABLE AND RIGGED DOOR MECHANISM IN ACCSDR AMTA200500187Connector · looseOVERWING ESCAPE BOTTLE PRESSURE WOULD NOT TEST. RESECURED CANNON PLUGS TO BOTTLES. TEST NORMAL. (M)SDR UPS05543904Smoke Goggles · crackedFWD OBS GOGGLES GLASS CRACKED. REPLACED SMOKE GOGGLES WITH SERVICEABLE PAIR.SDR SWAA050433Glowstrip · delaminatedDURING SCHEDULED A1 CHECK, FOUND 2 EACH SECTIONS OF EMERGENCY EXIT PHOTOLUMINESCENT STRIPS IN FWD CABIN, DELAMINATED. REMOVED AND REPLACED PHOTOLUMINESCENT STRIPS PER MM.SDR UPS05M43885Smoke Goggles · crackedJRT- COURIER SEAT SMOKE GOGGLES HAS CRACKED LENS. REMOVED AND REPLACED RT COURIER SEAT SMOKE GOGGLES IAW MM 25-00-00.SDR UPS05543884Smoke Goggles · crackedCAPTS SMOKE GOGGLES CRACKED. REPLACED CAPTS GOGGLES.SDR SWAA050401Latch · out of adjustF/O'S ESCAPE SLIDE ROPE COVER RELEASE KNOB, STUCK. ADJUSTED AND LUBED LATCH PER MM.SDR DHL2005752001Smoke Hood · damagedCREW PBE ON COCKPIT DOOR HAS RED BUTTON EXTENDED BEYOND BOX. REMOVED AND REPLACED CREW PBE IAW B-M/M 25-60-02.SDR AWXA200500170Battery · dischargedMAINTENANCE FOUND THE AFT GALLEY OUTBOARD EMERGENCY FLASHLIGHT INOPERATIVE. MX REMOVED AND REPLACED THE EMERGENCY FLASHLIGHT. OPERATIONAL CHECK WAS GOOD.SDR DL76S050090Strap · brokenAFT LEFT FA JUMPSEAT EMERGENCY FLASHLIGHT STRAP BROKEN. REPLACED FLASHLIGHT AND STRAP.SDR SWAA050325Latch · brokenDURING SCHEDULED A1 CHECK, FOUND F/O ESCAPE ROPE DOOR LATCH BROKEN. REMOVED AND REPLACED LATCH PER MM.SDR AWXA200500169Battery · dischargedEMERGENCY EQUIPMENT - MAINTENANCE FOUND THE AFT EMERGENCY FLASHLIGHT INOPERATIVE. MX REMOVED AND REPLACED THE AFT EMERGENCY FLASHLIGHT. OPERATIONAL CHECK GOOD.SDR MWEA050020Megaphone · inoperativeMEGAPHONE FOUND INOPERATIVE DURING CABIN CHECK. INSTALLED SERVICEABLE MEGAPHONE.SDR 2005UALA00118Bracket · brokenTORQUE BAR SUPPORT BRACKETS BROKEN. INSTALLED NEW SUPPORT BRACKETS.SDR UPS05443841Battery · inoperativeEMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERY, OPS CK GOOD AT THIS TIME.SDR UPS05443839Crash Ax · damagedCRASH AX NEEDS TO HAVE DEFECTS BLENDED. REMOVED AND REPLACED CRASH AX WITH SERVICEABLE PART OK FOR SERVICE.SDR AWXA200500091Battery · dischargedORD - EMERGENCY EQUIPMENT, MAINTENANCE FOUND THE FORWARD GALLEY EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD GALLEY EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR AWXA200500300Flashlight · inoperativeMCN - EMERGENCY EQUIPMENT - DURING C-18 CHECK FOUND THE LT AFT LAVATORY WALL EMERGENCY FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED LT AFT LAVATORY WALL EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR AWXA200500299Flashlight · inoperativeMCN - EMERGENCY EQUIPMENT - DURING C-18 CHECK FOUND THE LT FORWARD EMERGENCY FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED LT FORWARD EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR SWAA050205Glowstrip · delaminatedDURING SCHEDULED PM CHECK, FOUND FWD RT PHOTOLUMINESCENT STRIP DELAMINATED. REMOVED AND REPLACED PHOTOLUMINESCENT STRIP PER MM.SDR 2006UALA01156Latch · failedLT O/W HATCH FAILS INTEGRATOR TORQUE CHECK. REPLACED LATCHES.SDR SWAA050148Glowstrip · wornDURING SCHEDULED C4 CHECK, FOUND EMERGENCY EXIT PHOTOLUMINESCENT STRIP AT ROW 8 ABC, WORN. REMOVED AND REPLACED PHOTOLUMINESCENT STRIP PER MM.SDR MALA050138Flashlight · inoperativeAFT CABIN EMERGENCY FLASHLIGHT NOT FLASHING (INDICATING). MAINTENANCE REPLACED AFT CABIN EMERGENCY FLASHLIGHT P/N P4-01-0021, OPS CHECK GOOD.SDR SWAA050097Flashlight · inoperativeAFT OUTBOARD EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT AND BATTERY PER MM.SDR UPS05M43648Lens · crackedMIDDLE COURIER SEAT SMOKE GOGGLES LENS CRACKED. INSTALLED SMOKE GOGGLES AT MIDDLE COURIER SEAT.SDR UPS05543647Smoke Goggles · crackedINSPECTION TYPE:N/A SMOKE GOGGLES AT AFT COURIER SEAT ARE CRACKED. REPLACED SMOKE GOGGLES.SDR 2006UALA01155Latch · failedLT O/W SLIDE DOOR INTEGRATOR FAILS TORQUE CHECK. REPLACED LATCHES IAW 767 MM 25-65-98.SDR SWAA050058Button · stuckCAPTAIN'S EMERGENCY ESCAPE ROPE DOOR BUTTON STUCK. ADJUSTED AND LUBED BUTTON PER MM.SDR YENA200505Pin · unsecureON BOARDING, EMERGENCY EXIT ROW SLIDE ARM INDICATOR INTERMITTENT A/C RIGHT. SECURED AFT RT EMERGENCY LATCH PIN IAW MM, OPS CK NORM 52-21-00.SDR MASA200500092Bulb · burned outCLT HAD AN F/O EMERGENCY FLIGHT OUT. MAINTENANCE REPLACED A FLIGHTLIGHT LAMP.SDR AWXA200500019Battery · dischargedPHX - EMERGENCY EQUIPMENT - DURING INSPECTION THE FORWARD EMERGENCY FLASHLIGHT WAS FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR MASA200500021Flashlight · inoperativeASH - CLT CREW REPORTED THE EMERGENCY FLIGHT DECK FLASHLIGHT INOP. MAINTENANCE CLEANED THE SWITCH AND OPS CHECKED THE FLASHLIGHT.SDR ASOA05020Glowstrip · damagedDURING HANGAR MAINTENANCE, THE EMERGENCY FLOOR LIGHT STRIP AFT OF ROW 12-C WAS FOUND NEEDING REPLACEMENT. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY PHOTO LUMINESCENT STRIP AFT OF ROW 12-C. OPERATIONAL CHECKS GOOD. AIRCRAFT OK FOR SERVICE. (K)SDR DL757050008Girt Bar · jammedA/C WOULD NOT PRESSURIZE AFTER T/O. OUTFLOW VALVE FULLY CLOSED, FOUND L2 DOOR GIRT BAR JAMMED IN FWD END OF DOOR. REPLACED BAR AND FITTINGS.SDR SWAA050019Attach Fitting · corrodedDURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EVAC SLIDE AFT GIRT BAR ATTACH FITTING, CORRODED. REMOVED AND REPLACED FITTING PER MM.SDR SWAA050002Glowstrip · looseEMERGENCY EXIT PHOTOLUMINESCENT STRIP AT ROW 8 ABC, LOOSE. REMOVED AND REPLACED PHOTOLUMINESCENT STRIP PER MM.SDR DL76S041148Power Supply · dischargedFOUND ON TRANSIT CHECK, EMERGENCY ESCAPE SQUIB TEST INOP IN BOTH TEST 1 AND 2. REPLACED POWER SUPPLY.SDR DL75K041145Battery · dischargedTHE 4R FLASHLIGHT BATTERY NOT BLINKING. REPLACED BATTERY.SDR AWXA200500006Battery · dischargedMCN - EMERGENCY EQUIPMENT - DURING C-17 CHECK THE FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY WAS FOUND LOW. MAINTENANCE REMOVED AND REPLACED THE FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.
Back to JASC 2560