Service difficulty reports · 40,741
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA041764Battery · inoperativeDURING SPV, FOUND FWD EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PER MM.SDR AWXA200400663Flashlight · inoperativePHX - EMERGENCY EQUIPMENT - FLIGHT CREW REPORTED THE EMERGENCY FLASHLIGHT UNDER AFT FLIGHT ATTENDANT JUMPSEAT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY FLASHLIGHT UNDER AFT FLIGHT ATTENDANT JUMPSEAT, OPERATIONAL CHECK WAS GOOD.SDR CX2A04RI003Lamp · burned outRIC - DURING ROUTINE INSPECTION, MAINTENANCE FOUND CAPTAINS EMERGENCY FLASHLIGHT NOT ILLUMINATING. MAINTENANCE REMOVED AND REPLACED FLASHLIGHT BULB. OPERATIONALLY CHECKED SUCCESSFULLY.SDR AWXA200400644Flashlight · inoperativePHX - EEL - FLIGHT CREW REPORTED THE FORWARD CABIN EMERGENCY FLASHLIGHT RED INDICATOR WAS NOT FLASHING. MAINTENANCE REMOVED AND REPLACED THE FORWARD CABIN EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR AWXA200400635Battery · dischargedPHX - EMERGENCY EQUIPMENT - FLIGHT CREW REPORTED THE FORWARD EMERGENCY FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BATTERIES IN THE FORWARD EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR ABXA040207Escape Rope · mismanufacturedCHECK EMERGENCY ROPE AT MAIN CABIN DOOR FOR PROPER LENGTH. ROBBED EMERGENCY ROPE FROM 826AX, CHECKED FOR PROPER LENGTH AND INSTALLED ON 811AX IAW DC-8 MM 25-60-02-0002. CANNIBALIZATION FORM WAS FILLED OUT.SDR KBM2004F00148Inertia Reel · mismanufacturedINERTIA REEL, HARD TO BUCKLE BELT. MANUFACTURED WITH WEBBING TOO SHORT. REMOVED AND REPLACED.SDR SWAA041655Flashlight · inoperativeDURING SPV, FOUND FWD UPPER EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT PER MM.SDR SWAA041653Flashlight · inoperativeDURING SCHEDULED C2 CHECK, FOUND AFT LOWER EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT PER MM.SDR ERAA096616Elt · crackedFOUND CRACKED ELT ASSY. SENT UNIT TO MANUFACTURER FOR REPAIR.SDR GTIA040569Glowstrip · crackedDTW - FOUND SAFETY GLOW COVER CRACKED, FORWARD LAV AREA ALSO NEEDS CLEANED. REPLACED SAFETY GLOW. (M)SDR SWAA041622Glowstrip · delaminatedDURING SCHEDULED SERVICE CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP DELAMINATED AT ROW 18 ABC TO ROW 20 ABC. REMOVED AND REPLACED PHOTOLUMINESCENT STRIP PER MM.SDR SWAA041616Hook · looseL1 DOOR EVAC SLIDE GIRT BAR HOOKS LOOSE. SECURED L1 DOOR EVAC SLIDE GIRT BAR HOOKS PER MM.SDR SWAA041598Strip · looseEEPLS PHOTOLUMINESCENT STRIP AT ROW 7 ABC, LOOSE. SECURED PHOTOLUMINESCENT STRIP PER MM.SDR MASA200400309Pbe · brokenCOCKPIT PBE SEAL BROKEN. REPLACED PBE.SDR SWAA041582Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EVAC SLIDE CABLE MISROUTED. REROUTED R2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA041573Cable · misroutedDURING SCHEDULED 1/4D CHECK, FOUND L2 DOOR EVAC SLIDE CABLE MISROUTED. REROUTED L2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA041572Hook · looseDURING SCHEDULED 1/4D CHECK, FOUND R1 DOOR EVAC SLIDE GIRT BAR HOOKS LOOSE. SECURED R1 DOOR EVAC SLIDE GIRT BAR HOOKS PER MM.SDR SWAA041569Hook · looseDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EVAC SLIDE FWD HOOK LOOSE. SECURED L1 DOOR EVAC SLIDE FWD HOOK PER MM.SDR ASOA04402Battery · inoperativeFLT 4696 - DURING A GROUND INSPECTION IN DFW, THE REAR PORTABLE MEGAPHONE WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN THE REAR PORTABLE MEGAPHONE. OPERATIONAL CHECKS GOOD. AIRCRAFT OK FOR SERVICE. (M)SDR GTIA040558Glowstrip · brokenFLL - FLT 367 - SAFE T GLO AT L1 GALLEY BROKEN. INSTALLED NEW SAFE T GLO AT L1 GALLEY. (M)SDR SWAA041532Glowstrip · loosePHOTO LUMINESCENT STRIP LOOSE AT RT ROW 7 AND RT ROW 8. SECURED STRIP PER MM.SDR AWXA200400581Flashlight · inoperativeEMERGENCY EQUIPMENT - FLIGHT CREW REPORTED THE CABIN FLASHLIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED CABIN EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR GTIA040552Glowstrip · dislodgedDTW - FOUND FLT 1678 - AFT GALLEY EMERGENCY TRACK GLOW STRIP CAME OFF. REINSTALLED STRIP. (M)SDR GTIA040517Glowstrip · looseFOUND SAFE T GLO STRIP MISSING L-2 DOOR AREA IN FRONT OF GALLEY. RESECURED SAFE T GLO STRIP L-2 DOOR AREA. OK FOR SERVICE. (M)SDR MALA040420Cap · dirtyCABIN DOOR FORWARD RT SIDE DOES NOT SHOW YELLOW MARKINGS ON GIRT BAR WHEN DOOR IS ARMED. MAINTENANCE INSPECTED RT FWD CABIN SERVICE DOOR GIRT BAR AND SLIDE ASSEMBLY. OPERATES NORMALLY. CLEANED GIRT BAR END CAPS AND CYCLED SEVERAL TIMES, OPERATION NORMAL AND SDR 04FDEA01468Mount Bracket · bentCAPTAINS ESCAPE ROPE MOUNT BRACKET IS BENT. CLOSING ACTION ON 05/25/04 ON N/R N00025. REMOVED AND REPLACED CAPTAINS ESCAPE ROPE MOUNT BRACKET IAW SRM 51-31-01.SDR CA040525005Shoulder Belt · inadequateIT WAS NOTED DURING INSPECTION, THAT THE REAR SEAT SHOULDER HARNESSES WERE NOT INCOMPLIANCE WITH AIRWORTHINESS DIRECTIVE 86-26-04. THIS DIRECTIVE IS SERIAL NUMBER SPECIFIC AND SHOULD NOT APPLY TO THIS AIRCRAFT. IT APPEARS THAT THESE HARNESSES WERE RECYCLED BSDR SWAA041493Hook · looseDURING SCHEDULED RON, FOUND R1 DOOR EVAC SLIDE GIRT BAR HOOKS LOOSE. REMOVED AND REPLACED R1 DOOR EVAC SLIDE GIRT BAR HOOKS PER SRM.SDR SWAA041482Plate · corrodedDURING SCHEDULED D-CHECK, FOUND L1 DOOR EVAC SLIDE GIRT BAR FLOOR MOUNT PLATES CORRODED. REMOVED AND REPLACED GIRT BAR MOUNT PLATES PER SRM AND MM.SDR MALA040416Cover · out of positionFA PBE COVER FELL OFF. UPON INSPECTION FOUND PBE COMPROMISED. REPLACED PBE.SDR AWXA200400562Battery · dischargedLCQ - EMERGENCY EQUIPMENT - DURING C-19 CHECK FOUND THE AFT GALLEY EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED AFT GALLEY EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR SWAA041443Cable · misroutedDURING SCHEDULED C4 CHECK, FOUND L2 DOOR EVAC SLIDE CABLE MISROUTED. REROUTED L2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA041415Cable · misroutedDURING SCHEDULED C1 CHECK, FOUND L1 AND R1 DOOR EVAC SLIDE CABLES MISROUTED. REROUTED L1 AND R1 DOOR EVAC SLIDE CABLES PER MM.SDR SWAA041368Glowstrip · wornDURING SCHEDULED 1/2D CHECK, FOUND PHOTOLUMINESCENT STRIP BETWEEN BS 336 AND BS 948, WORN. REMOVED AND REPLACED PHOTOLUMINESCENT STRIP PER ACO.SDR UPS04242428Ring · disconnectedINSPECTION TYPE: C SLIDE LATCH RING ON FWD E DOOR ESCAPE SLIDE AND GIRT BAR TO SLIDE COMPARTMENT LATCH CHAIN FOUND DISCONNECTED. REPLACED RING AND CONNECTED CHAIN TO SLIDE LATCH IAW 25 -60-04.SDR GTIA040446Pin · out of positionCHECK L1 DOOR SLIDE PACK. FOUND LANYARD AND UNFURLING PINS OUT. REMOVED SLIDE FROM DOOR AND REINSTALLED UNFURLING PINS. REINSTALLED PACK BACK ON L1 DOOR AND LANYARD. NO FURTHER DEFECTS NOTED.SDR GTIA040445Cable · misinstalledL-1 DOOR ESCAPE SLIDE GIRT BAR CABLE IMPROPERLY INST. REPOSITIONED CABLE ON GIRT BAR.SDR GTIA040444Lanyard · disengagedL1 DOOR PACK SLIDE LANYARD DISENGAGED FROM DOOR (SLIDE DID NOT FALL OFF OF DOOR). REINSTALLED LANYARD.SDR GTIA040443Lanyard · misinstalledR1 GALLEY SERVICE DOOR, LANYARD NEED TO BE REINSTALLED. REINSTALLED LANYARD AT R1 GALLEY SERVICE DOOR. OPS CK GOOD.SDR SWAA041266Glowstrip · delaminatedPHOTOLUMINESCENT STRIP AT ROW 7 ABC, DELAMINATED. REMOVED AND REPLACED FLOOR STRIP PER MM.SDR AWXA200400457Battery · dischargedDEN - EMERGENCY EQUIPMENT - DURING A-01 CHECK FOUND THE FORWARD EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR SWAA041224Cable · misroutedDURING SCHEDULED C1 CHECK, FOUND L2 AND R2 DOOR EVAC SLIDE CABLES MISROUTED. REROUTED L2 AND R2 DOOR EVAC SLIDE CABLES PER MM.SDR GTIA040395Cable · misroutedDTW - FLT 955 - FOUND L-2 DOOR ESCAPE SLIDE CABLE TO GIRT BAR INCORRECTLY ATTACHED. REPOSITIONED CABLE. (M)SDR GTIA040423Flashlight · missingRT AFT LAV AFT SIDE MISSING 2 EA EMERGENCY LIGHTS. RT AFT LAV EMERGENCY FLASHLIGHTS ARE INSTALLED.SDR SWAA041179Fitting · corrodedDURING SCHEDULED D CHECK, FOUND L1 DOOR EVAC SLIDE GIRT BAR FITTINGS CORRODED. REPAIRED GIRT BAR FITTINGS PER SRM.SDR SWAA041167Battery Pack · dischargedDURING SCHEDULED 1/2D CHECK, FOUND AFT EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PACK PER MM.SDR GTIA040439Strap · misinstalledTAIL SLIDE COVER HOLD DOWN STRAPS NOT INSTALLED CORRECTLY. INSTALLED TAIL CONE EMERGENCY SLIDE COVER STRAPS CORRECTLY.SDR SWAA041156Glowstrip · wornDURING SCHEDULED C4 CHECK, FOUND PHOTOLUMINESCENT STRIPS AT 10 D AND 15 C, WORN. REMOVED AND REPLACED STRIPS PER MM.SDR AWXA200400406Flashlight · inoperativeDURING 4-DAY CHECK FOUND THE MID CABIN EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED MID CABIN EMERGENCY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.
Back to JASC 2560