JASC 2560
Service difficulty reports · 40,741
Reports filed under 2560 · Emergency Equipment, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2560' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 03044660Battery · dischargedCAPTAINS EMERGENCY FLASHLIGHT DIM. REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERY. OPERATIONAL CHECK PERFORMED AND AIRCRAFT WAS RELEASED BY MAINTENANCE PERSONNEL FOR CONTINUED SERVICE.SDR SWAA030354Strip · looseEEPLS PHOTOLUMINESCENT STRIP LOOSE BETWEEN ROWS NR 6 AND NR 8 ABC. REMOVED AND REPLACED STRIP PER MM.SDR AWXA200300133Battery · dischargedEMERGENCY EVACUATION - DURING INSPECTION THE AFT GALLEY FLASHLIGHT BATTERY LIFE INDICATOR WAS NOT FLASHING. MAINTENANCE REMOVED AND REPLACED THE BATTERY IN THE AFT GALLEY FLASHLIGHT, OPERATIONAL CHECK WAS GOOD.SDR SWAA030328Sign · looseLT OVERWING EMERGENCY EXIT SIGN LOOSE. SECURED SIGN PER MM.SDR AWXA200300106Battery · dischargedLAX - EMERGENCY EQUIPMENT - DURING ROUTINE MX INSPECTION MAINTENANCE DISCOVERED THE FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT DISCHARGED/INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY IN THE FORWARD FLIGHT ATTENDANT POSITION, OPERATIONAL CHECK WSDR AALA20030162Flashlight · inoperativeSFO - DURING OVERNIGHT MAINTENANCE, FORWARD CENTER RIGHT FLIGHT ATTENDANT EMERGENCY EXIT FLASHLIGHT INOPERATIVE. REPLACED FORWARD CENTER RIGHT FLIGHT ATTENDANT EMERGENCY EXIT FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR F3LA200300046Pad · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON SLIDE GIRT BAR LOCK PAD AT STA 344, LBL 59. FABRICATED AND INSTALLED REPLACEMENT PAD PER SRM 51-40-02.SDR DL757030101Placard · wornTHE 3 RT RAFT SURVIVAL KIT HAS DIRECTIONS PLACARDS THAT IS HARD TO READ. REMOVED AND REPLACED 3 RIGHT SURVIVAL KIT.SDR SWAA030198Battery · dischargedDURING SCHEDULED SERVICE CHECK, FOUND UPPER AFT EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED BATTERY PER MM.SDR AALA20030093Flashlight · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLASHLIGHT BY L2 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT FLASHLIGHT BY L2 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR SWAA030152Strip · looseDURING SCHEDULED C1 CHECK, FOUND EEPLS PHOTOLUMINESCENT STRIP LOOSE AT ROW 11 DEF. SECURED STRIP PER MM.SDR SWAA030144Battery · dischargedFWD OUTBD EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT BATTERY PER MM.SDR SWAA030136Retainer · brokenDURING SCHEDULED A2 CHECK, FOUND FWD LOWER EMERGENCY FLASHLIGHT HOLDER BROKEN. REMOVED AND REPLACED EMERGENCY FLASHLIGHT HOLDER PER MM.SDR SWAA030119Strip · loosePORTION OF THE EEPLS SELF ILLUMINATION STRIP NOT SECURED. SECURED THE EEPLS STRIP PER MM.SDR SWAA030113Attach Fitting · corrodedDURING SCHEDULED D CHECK, FOUND CORROSION ON THE L1 GIRT BAR ATTACH FITTINGS BS 312 AND BS 344. REMOVED AND REPLACED THE L1 GIRT BAR ATTACHED FITTINGS PER MM.SDR SWAA030069Strip · looseEEPLS PHOTOLUMINESCENT STRIP LOOSE AT ROW 6 ABC. SECURED STRIP PER MM.SDR ZW0A0300809Fitting · corrodedDURING CHECK-C MAINT IN THE FWD CABIN AT THE FWD SERVICE DOOR WAY, FOUND SILL BRACKET (GIRT BAR FITTING) CORRODED AT STA 172, RBL 53. REMOVED AND REPLACED FITTING PER SPM 6-70-01.SDR 374PA0002Battery · dischargedFWD FLIGHT ATTENDANT JUMPSEAT OUTBOARD EMERGENCY FLASHLIGHT LED WILL NOT FLASH. ITEM DEFERRED PER MEL 25-12, CONTROL NR 0112001. 1/15/2003. R & R BATTERY POWER UNIT AS REQUIRED. OPS CHECK NORMAL. CLEARED MEL 25-12, CONTROL NR 0112001SDR SWAA030066Strip · looseEEPLS PHOTOLUMINESCENT STRIP LOOSE BETWEEN ROWS NR 8 AND NR 10 AT BOTH ABC AND DEF. SECURED PHOTOLUMINESCENT STRIP PER MM.SDR DL738030050Battery · dischargedFC FLT ATTENDANT EMERG FLASHLIGHT INOP. REPLACED BATTERY.SDR AWXA200300027Battery · dischargedSAN - EMERGENCY EQUIPMENT - DURING INSPECTION THE AFT CABIN EMERGENCY FLASHLIGHT WAS FOUND INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFT CABIN EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR HEEA083300Seat Belt · frayedSEAT BELT FRAYED AT TOP OF SHOULDER HARNESS.SDR HEEA083299Seat Belt · mismanufacturedSEAT BELT RESTRAINT TOO SHORT.SDR HEEA083298Seat Belt · mismanufacturedSTRAPS ON SHOULDER HARNESS TOO SHORT.SDR HEEA083297Seat Belt · wornSEAT BELT WORN AND FRAYED.SDR HEEA083296Seat Belt · misinstalledMOUNTING BRACKET ORIENTATION IS BACKWARD. REEL IS NOT FUNCTIONING PROPERLY (RATCHETY).SDR HEEA083295Seat Belt · misinstalledSHOULDER STRAP IS INSTALLED ON REEL BACKWARDS. FLAT SIDE OF ADJUSTMENT BUCKLES ARE NOT TOWARD CHEST WHEN WORN BY PILOT. REEL CAN ONLY BE INSTALLED ONE WAY.SDR HEEA083294Seat Belt · mismanufacturedBELTS (SHOULDER HARNESS) WAS SEWN WRONG SIDE OUT. SHOULDER STRAP ADJUSTMENT ARE ON THE INSIDE (WRONG SIDE).SDR HEEA083293Seat Belt · malfunctionedSEAT BELT WILL NOT RETRACT.SDR 2003F00097Panel · inoperativeEVAC WARNING PANEL AT L1 DOOR HAS NO TONE DURING TEST. REMOVED AND REPLACED EVAC WARNING PANEL AT L1 DOOR.SDR GTIA030001Light · inoperativeFLL - FOUND HAND HELD EMERGENCY LIGHT BY L1 DOOR IS INOPERATIVE. REMOVED AND REPLACED L1 DOOR HAND HELD EMERGENCY LIGHT PER MM 33-50-00, OPS CHECK GOOD. (M)SDR HEEA083251Seat Belt · damagedSEAT BELT HARD TO ADJUST LAP BELT PORTION. REPAIRED.SDR HEEA083250Seat Belt · damagedRUBBER SHOULDER HARNESS SPACER MISSING. REPAIRED.SDR HEEA083249Seat Belt · frayedSEAT BELT FRAYED. SCRAPPED.SDR HEEA083248Seat Belt · brokenLT FWD FACING SEAT BELT IS BROKEN AT SPRING. REPAIRED.SDR SWAA030040Battery · dischargedFWD INBOARD EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT BATTERY PER MM.SDR 2003F00085Retainer · defectiveGIRT BAR RETAINER DEFECTIVE AT L1 DOOR. ADJUSTED GIRT BAR RETAINER HOOKS, OK FOR SERVICE.SDR 2003F00079Battery · dischargedEMERGENCY FLASHLIGHT, BEHIND SEAT 15D, BATTERY IS DEAD. REMOVED AND REPLACED FLASHLIGHT BATTERY.SDR 2003F00072Connector · inoperativeEVAC HORN AT L1 DOOR DOES NOT SOUND DURING TEST. RESEATED CONNECTOR PLUG ON EVAC BOX AT L1 AS REQUIRED.SDR ASAA0280034AFitting · corrodedOKC - FOUND DURING 30K CHECK, FORWARD SERVICE (R-1) DOOR EMERGENCY SLIDE GIRT BAR ATTACH FITTING IS CORRODED. REPLACED FITTING PER SRM 51-30-1. (M)SDR SWAA030008Battery · dischargedAFT CABIN EMERGENCY FLASHLIGHT INOP. REMOVED AND REPLACED FLASHLIGHT BATTERY PER MM.SDR AWXA200300012Battery · inoperativeFLIGHT CREW REPORTED THAT THE AFT RT EMERGENCY FLASHLIGHT DOES NOT HAVE FLASHING RED LIGHT. MAINTENANCE REMOVED AND REPLACED THE AFT RT EMERGENCY FLASHLIGHT BATTERY, OPERATIONAL CHECK WAS GOOD.SDR AWXA200300001Battery · dischargedFLIGHT CREW REPORTED THAT THE AFT CABIN EMERGENCY FLASHLIGHT WAS INOPERATIVE. AFT CABIN EMERGENCY FLASHLIGHT PLACED ON MEL 25-12 COND. 1, EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY IN THE AFT CABIN EMERGENCY FLASHLIGHT; OPSDR ASAA0280695Fitting · corrodedOKC - FOUND DURING 30K CHECK, FORWARD SERVICE (R-1) DOOR EMERGENCY SLIDE GIRT BAR FLOOR FITTING IS CORRODED AT FS 160. REPLACED FITTING PER SRM 51-30-1. (M)SDR SWAA023027Flashlight · inoperativeEMERGENCY FLASHLIGHT AT AFT CABIN STATION INOP. REMOVED AND REPLACED EMERGENCY FLASHLIGHT PER MM.SDR SWAA023000Sign · looseRT OVERWING EXIT SIGN LOOSE. SECURED EXIT SIGN PER MM.SDR MALA020689BatteryDEAD EMERGENCY FLASHLIGHT BATTERIES. MAINTENANCE REPLACED BATTERY PN P4-01-0021. OPS CHECKS GOOD.SDR SIMA200235702Flashlight · inoperativeORD - FLT 4061 - CREW REPORTED A STRONG ODOR IN CABIN SIMILAR TO ELECTRICAL BURNING SMELL IN FORWARD CABIN NEAR THE FLIGHT ATTENDANT JUMPSEAT. MAINTENANCE FOUND THE FLIGHT ATTENDANT FLASHLIGHT ASSEMBLY OVERHEATED AND MELTED. ALSO, NOTED WIRING HARNESS DAMAGESDR AALA20021823Flashlight · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PORTABLE FLASHLIGHT INOPERATIVE. REPLACED EMERGENCY EXIT FLASHLIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 2003F00006Panel · inoperative(ORIG-CLOSED) DURING SCHEDULED MAINTENANCE EVAC SIGNAL PANEL AT L1 DOOR HAS NO AURAL SIGNAL. MAINTENANCE REMOVED AND REPLACED EVAC SIGNAL PANEL IAW MM, OPERATIONAL CHECK GOOD.
Back to JASC 2560