SDR 2003FA0000875Life Vest · failedLIFE VEST FAILED. MFG RECOMMENDED CELL PRESSURE TEST. DOM: JULY 1987SDR AUS20030755Valve · stuck(AUS) LIFE JACKET ORAL INFLATION TUBE JAMMED IN OPEN POSITION. A SECOND JACKET HAD THE SAME PROBLEM WHILE A THIRD JACKET FROM THE SAME BATCH DID NOT. JACKETS ARE USED ON DASH-8 AIRCRAFT.SDR 2003FA0001033Life Vest · failedLIFE VEST FAILED, MFG RECOMMEND CELL PRESSURE TEST IAW 25-60-7. DOM: 3/1985SDR HEEA087495Life Vest · leakingLIFE VEST LEAKING. REPLACED.SDR HEEA087494Life Vest · leakingLIFE VEST LEAKING. REPLACED.SDR HEEA087254Life Vest · leakingLIFE VEST LEAKING. REPLACED.SDR HEEA087252Latch · brokenONE LATCH ON STRAP IS BROKEN. REPLACED LIFE VEST.SDR HEEA087198Seat Belt · wornLAP SEAT BELT WORN. SENT TO AIRCRAFT BELTS FOR INSPECTION AND REPAIR.SDR 2003FA0000593Life Vest · failedLIFE VEST FAILED. MFG RECOMMENDED CELL PRESSURE TEST IAW MANUAL 25-60-1. DOM: MAY 1980SDR 2003FA0000592Life Vest · failedLIFE VEST FAILED. MFG RECOMMENDED CELL PRESSURE TEST IAW 25-60-1. DOM: JANUARY 1983SDR 2003FA0000591Life Vest · failedLIFE VEST FAILED, MFG RECOMMENDED CELL PRESSURE TEST IAW 25-60-1. DOM JANUARY 1983SDR 2003FA0000510Life Vest · failedINDIVIDUAL FLOAT DEVICE FAILED. MFG RECOMMENDED CELL PRESSURE TEST IAW 25-60-13. DOM: OCT 1983.SDR 2003FA0000509Life Vest · failedINDIVIDUAL FLOAT DEVICE FAILED MFG RECOMMENDED CELL PRESSURE TEST IAW 25-60-13. DOM: OCT 1983.SDR 2003FA0000508Life Vest · failedLIFE VEST FAILED MFG RECOMMEND CELL PRESSURE TEST IAW 25-60-1 DOM: JANUARY 1981.SDR 2003FA0000341Life Vest · failedLIFE PRESERVER FAILED. MANUFACTURER RECOMMENDED PSI CELL TEST. DOM:NOV 1980SDR HEEA085062Life Vest · will not testLIFE VEST FAILED 3 MONTH INSPECTION (WOULD NOT HOLD AIR). SHOP REPAIR.SDR HEEA085012Life Vest · damagedLIFE VEST HAS A BROKEN CLIP.SDR HEEA085011Life Vest · leakingLIFE VEST FAILED 3 MONTH (LEAKING).SDR HEEA085010Life Vest · damagedLIFE VEST HAS WORN VELCRO AND TORN LIGHT.SDR HEEA085009Life Vest · leakingLIFE VEST LEAKS.SDR HEEA085008Life Vest · leakingLIFE VEST LEAKS.SDR HEEA085007Life Vest · leakingLIFE VEST LEAKS.SDR HEEA085006Cover · wornLIFE VEST COVER HAS WORN VELCRO.SDR HEEA085005Cover · tornLIFE VEST COVER POCKET TORN.SDR HEEA084805Clip · brokenCLIP FOR LIFE VEST STRAP BROKEN.SDR 2003FA0000090Life Vest · failedINDIVIDUAL FLOAT DEVICE FAILED MFG RECOMMENDED CELL PRESSURE TEST. DOM JUNE 1991.SDR 2003FA0000071Life Vest · failedLIFE VEST FAILED, MFG RECOMMENDED CELL PRESSURE TEST. DOM: JULY 1990SDR 2003FA0000091Life Vest · failedFLOAT DEVICE FAILED MFG RECOMMENDED CELL PRESSURE IAW 25-60-13. DOM: NOV 1981.SDR HEEA082646Life Vest · leakingLIFE VEST LEAKING.SDR 2002FA0001358Bottle · brokenCARBON DIOXIDE BOTTLE HOUSING WAS BROKEN DUE TO BLUNT IMPACT FORCE APPLIED.SDR 2002FA0001230Life Vest · failedINDIVIDUAL FLOATATION DEVICE FAILED, MFG RECOMMENDED CELL PRESSURE TEST.SDR 2002FA0001206Life Vest · failedLIFE PRESERVER FAILED, MFG RECOMMEDNED CELL PRESSURE TEST IAW MM. DOM JANUARY 1983SDR 2002FA0001044Life Vest · failedINDIVIDUAL FLOTATION DEVICE FAILED, MANUFACTURER RECOMMENDED PRESSURE TEST IAW MM. DOM: NOV 1984.SDR 2002FA0000804Life Vest · failedLIFE VEST FAILED. THE MANUFACTURER RECOMMENDED PRESSURE TEST. DOM: JUNE 1983.SDR 2002FA0000803Life Vest · failedLIFE VEST FAILED. THE MANUFACTURER RECOMMENDED PRESSURE TEST. DOM: JUNE 1983SDR MALA020258Life Vest · unsecureON FLIGHT 3525, SEAT 3B/C LIFE VESTS NEED TO BE SECURED UNDER SEAT. MAINTENANCE RESECURED SEATS, ALL CHECKS GOOD AT THIS TIME.SDR 2002FA0000617Life Vest · failedFLOTATION DEVICE FAILED MFG RECOMMEDNED 2 PSI PRESSURE TEST.SDR 2002FA0000554Life Vest · failedLIFE VEST FAILED, MFG ECOMMENDED PRESSURE TEST. DOM: FEB 1985SDR 2002FA0000675Life Vest · failedLIFE VEST FAILED, MFG RECOMMENDED CELL PRESSURE TEST.SDR UPS02837962Life Vest · tornINSPECTION TYPE:N/A CAPTS LIFE VEST TORN. REPLACED CAPT LIFE VEST.SDR 2002FA0000228Life Vest · failedLIFE VEST FAILED THE MFG. RECOMMENDED 2 PSI CELL TEST IAW MANUAL. DOM APRIL 1982.SDR 2002FA0000206Life Vest · failedLIFE VEST FAILED, MFG RECOMMENDED 2PSI, CELL TEST IAW 25-60-1.SDR 2002FA0000227Life Vest · failedLIFE VEST CELL FAILED. MFG RECOMMENDED 2 PSI TEST IAW MANUAL. DOM OCT 1981.SDR 2002FA0000168Life Vest · failedINDIVIDUAL FLOTATION DEVICE FAILED MFG RECOMMENDED 2 PSI CELL TEST.SDR 2002FA0000164Life Vest · failedINDIVIDUAL FLOTATION DEVICE FAILED MFG RECOMMENDED 2 PSI CELL TEST IAW SB.SDR 2002FA0000137Life Vest · failedLIFE VEST FAILED,SDR 2002FA0000093Life Vest · failedLIFE VEST FAILED.SDR 2003FA0000116Life Vest · failedINDIVIDUAL FLOAT DEVICE FAILED. MFG RECOMMENDED CELL PRESSURE TEST IAW 25-60-13. DOM NOV 1984.SDR AUS20011250Life Vest · mismarked(AUS) OVERHAULED LIFE JACKETS INCORRECTLY MARKED. LIFE JACKETS ARE EITHER INFANT OR ADULT FIT ITEMS BUT ARE ALL MARKED ON THE OUTSIDE OF THE STORAGE BAGS AS KSE-35L8 WHICH ARE ADULT FIT ITEMS. THE INFANT FIT JACKETS SHOULD BE MARKED P0640.101. THE INCORRECTSDR HEEA077006Harness · wornWORN. REPLACED WITH SERVICEABLE PART.
Back to JASC 2561