SDR USAA2014020300018Slide · shortedEMERGENCY POWER SUPPLY UNIT FAULT. THE L2 DOOR SLIDE BAD & SHORTED. R & R L2 DOOR SLIDE ASSEMBLY IAW 26L00025012.SDR DALA14006316717Handle · damagedDURING LEFT OVERWING SLIDE PNUEMATIC DEPLOYMENT TEST, LEFT ROUND CRANK HANDLE WILL NOT STAY UP AND LOCKED IN THE UNLOCK POSITION AND CRANK ROLLER DOES TOUCH PISTON ROD. R & R LT OVERWING ESCAPE SYS CRANK HANDLE IAW AMM 25-65-12-404-028. ACCOMPLISHED OPS CHECSDR IPXA2014013181713Circuit Breaker · inoperativeSLIDE TC WARNING LIGHT INOPERATIVE WHEN TESTED IAW TSM 52-73-00, FIG 102, BLK 5. R & R CIRCUIT BREAKER (1WN) ON OVERHEAD PANEL, IAW ESPM 20-46-10. OPS CHECKED GOOD IAW AMM 52-73-00-0501.SDR HALA2014012800017Slide · warning messageTWO MAINT MESSAGES FAULTED. MESSAGE 256241 ESCAPE SLIDE LT/EPSU (16WL) DOOR 3, & MESSAGE 256241 ESCAPE SLIDE LT/EPSU (17WL) DOOR 4. PERFORMED TROUBLESHOOTING TASKS IAW TSM 25-62-00-810-802A; INSPECTED L3 AND L4 DOOR SLIDES FOR LOOSE CONNECTIONS. FOUND LOOSE CSDR SWAA2014012924652Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR IPXA2014013181712Indicator · inoperativePDC FOUND THE EVACUATION SLIDE REMOTE PRESS-TO-TEST INDICATION LIGHT INOPERATIVE. R & R REMOTE PRESSURE INDICATOR IAW AMM 25-61-04. OPS CK GOOD.SDR R61A201401270153Slide · malfunctionedCREW REPORTED THAT DURING EMERGENCY EVACATION OF ACFT AT GATE, THE R1 DOOR DID NOT FULLY OPEN AND THE SLIDE DID NOT DEPLOY. F/O KICKED DOOR AND THE SLIDE FULLY DEPLOYED. ACFT IS CURRENTLY OUT OF SERVICE.SDR SWAA2014012724571Slide · unsecureR1 DOOR EMERGENCY EVAC SLIDE FELL OUT. R & R SLIDE ASSEMBLY IAW MT.SDR FDEA201401250195Slide · unsecureLEFT ENTRY DOOR SLIDE PARTIALLY UNSTOWED. COMPLIED WITH ESCAPE SYS INSPECTION & CHECKED IAW MM 25-66-01-6. L1 DOOR OPERATIONS CHECKED GOOD. ACFT OK FOR SERVICE.SDR USAA2014012700043Bottle · defectiveMAINTENANCE REPORTED A CIDS CAUTION, SLIDE BOTTLE EXIT RT. TROUBLE SHOT 7777 MM SLIDE BOTTLE LOW PRESS IAW TSM 25-62-00-810-810-A. REPLACED 7777MM SLIDE BOTTLE IAW AMM 25-62-49.SDR R61A201401240141Indicator · out of positionCREW REPORTED THAT THE L1 DOOR SLIDE DISARM INDICATOR IS NOT FULLY GREEN WHEN DISARMED. MAINTENANCE ADJUSTED SLIDE INDICATION IAW AMM AND OPS CHECKED GOOD. AIRCRAFT IS GOOD FOR SERVICE.SDR DALA14005130668Slide · inoperativeDURING AN INADVERTENT DEPLOYMENT OF THE LT OVERWING SLIDE. SLIDE DID NOT FULLY DEPLOY. LEFT OVERWING SLIDE REPLACED IAW AMM 25-65.SDR USAA2014012100020Reservoir · low pressureCREW REPORTED A CIDS CAUTION ILLUMINATED. THE RT OVERWING SLIDE RESERVOIR LOW. REPLACED RT OFF WING SLIDE INFLATION RESERVOIR IAW AMM 25-62-46-400-001A. CIDS PANEL CHECKED OK.SDR USAA2014012100019Slide · low pressureL2 DOOR ESCAPE SLIDE LOW ON PRESS. REPLACED L2 DOOR ESCAPE SLIDE IAW TC 26L00025010.SDR SWAA2014012024340Slide · looseL2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW TC.SDR FDEA201401170124Plate · missingRIGHT CREW ENTRY DOOR SLIDE ARMED OR DISARMED INDICATOR. REG GREEN METAL PLATE MISSING, FELL DOWN INTO DOOR.SDR FDEA201401170123Slide · inoperativeL1 DOOR SLIDE DOES NOT ARM. RELEASED FOR SERVICE IAW MEL 52-11-01-A. L1 DOOR SLIDE INOPERABLE, IDENTIFY INOPERABLE OR MISSING.SDR DALA14004465649Slide · inoperativeLEFT OVERWING SLIDE DID NOT DEPLOY OPEN OR INFLATE. R & R SLIDE.SDR USAA2014011600005Slide · low pressureTHE R1 DOOR SLIDE PRESS IN THE RED. REPLACED DOOR SLIDE AT R1 DOOR IAW TC 26L00025010.SDR SWAA2014011524120Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESS GAUGE LOW. R & R SLIDE IAW AMM.SDR SWAA2014011424095Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR SWAA2014012024320Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW SWA MT.SDR SWAA2014011324036Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. R & R SLIDE IAW MT.SDR CALA2014011390126Slide · unknownEMERGENCY LIGHT TEST INDICATED EXTERIOR LOADS AFT LT. SLUG DOORS AT 2L & 2R CONFIRMED FAULT AT DOOR 2R SLIDE PACK. REINSTALLED BOTH SLIDE PACKS IAW MM25-62-44-401.SDR DALA14002459540Lanyard · misinstalledTAILCONE SLIDE LANYARD HAS THE INCORRECT SHRINK TUBING INSTALLED. COMPLIED WITH ER/A 522284-14 AND INSTALLED CORRECT TUBING.SDR SWAA2014010923927Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. R & R SLIDE IAW MT.SDR ASAA2014010806752Slide · no testL2 DOOR SLIDE FAILED DEPLOYMENT TEST. TWO INTEGRAL LIGHTS FAILED TO ILLUMINATE. ACFT GROUNDED. SLIDE REPLACED ON T/C 61621-469 PNC.SDR IPXA2014011001261Lamp · inoperativeL1 DOOR SLIDE TEST FAILED. REPLACED LAMP IAW AMM 52-00-00. OPS CHECKED GOOD.SDR SWAA2014011324009Slide · unsecureL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR SWAA2014010823864Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MT.SDR DALA14001219551Cover · out of positionDURING CONFORMITY INSPECTION, THE TAIL CONE SLIDE PRESSURE INDICATOR WAS NOTED TO BE UNREADABLE. MAINTENANCE ADJUSTED THE COVER TO ENABLE PROPER READING.SDR FDEA201401050022Slide · faultyL1 DOOR LOW BOTTLE PRESS INDICATOR LIGHT ILLUMINATED. REMOVED L1 DOOR SLIDE LOWER COVER & TROUBLESHOOT IAW ASM 25-61-0. FOUND CONTINUITY AT LIGHT ASSEMBLY JACK CONNECTOR. REPLACED L1 DOOR SLIDE IAW AMM 25-61-02-4.SDR USAA2014010600024Bottle · brokenLEFT OVERWING SLIDE BOTTLE CABLE END BROKEN. REPLACED LT OVERWING SLIDE BOTTLE IAW A320 AMM 25-62-46.SDR GTIA201401031098Slide · unwanted deployR1 SLIDE DEPLOYED. R & R DOOR ASSIST BOTTLE DIAPHRAM IAW AMM, R & R R1 DOOR SLIDE IAW AMM, REMOVED AND STOWED SAFETY PIN FROM R1 DOOR AND RE ACATIVATED DOOR ASSIST BOTTLE IAW AMM.SDR SAJF201401103001Slide · defectiveB-18709 THE UD SLIDE FAILED TO DEPLOY DURING ROUTINE TEST IAW AMP 52-023-01 ON 01/01/2014. THE SLIDE STUCK IN MIDDLE TRAVEL ROUTE AROUND 180 DEGREES & NO MORE MOVING. FINALLY, CHI STAFF PULL T HANDLE TO MANUAL RELEASE THE SLIDE & INFLATION SUCCESSFULLY WITHISDR FDEA201312310071Slide · out of positionL1 DOOR IS VERY DIFFICULT TO ARM, DISARM & OPEN OR CLOSE. HAD TO USE R1 DOOR FOR ENTRY & EXIT. L1 NEEDS LUBE & RE-RIG. REMOVED & REINSTALLED L1 DOOR SLIDE COVER TO FOM IAW AMM-25-66-01. REMOVED & REINSTALLED L1 DOOR UPPER & MID-SECTION LINERS IAW AMM-52-11SDR DALA13072590918Slide · misinstalledINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE IN THE TAILCONE WAS IMPROPERLY INSTALLED. THIS CONFIGURATION OF THE SLIDE WOULD HAVE PREVENTED PROPER DEPLOYMENT OF THE ESCAPE SYSTEM AND IS NOT IN COMPLIANCE WITH 14 CFR, PART 121.703. THE TAILCONE SLIDESDR IPXA201401021193Warning System · malfunctionedEVACUATION SLIDE RELEASE WARNING SYS BUZZER INOPERATIVE. SLIDE WARNING SYSTEM TESTED NORMAL. TESTED PER TSM 52-73. COULD NOT DUPLICATE DISCREPANCY. REPLACED TEST SWITCH 392N AS PRECAUTION IAW ASM 52-73-00. TESTED PER AMM 52-73-14, PARA 2.3.SDR CALA2013123094053Strap · unsecureDOOR 1R WILL NOT ARM FOUND STRAP LOOSE FROM SLIDE PACK JAMMING IT. STOWED LOOSE STRAP PROPERLY, PUT SLIDE COVER ON SECURELY, DOOR 1R ARMED NORMAL.SDR WX0A20131231001Slide · unsecureL1 DOOR SLIDE FELL OUT OF COMPARTMENT. INSTALLED L1 DOOR EVAC SLIDE IAW 25-62-00, NO DEFECTS NOTED.SDR SWAA2014010723784Slide · unsecureL1 DOOR EMERGENCY EVAC SLIDE FELL OUT. REINSTALLED SLIDE IAW MM.SDR SWAA2014010223761Slide · out of positionTAIL CONE SLIDE SIGHT OUT OF POSITION. REPOSITIONED SLIDE ASSEMBLY IAW AMM.SDR CALA2014010200005Slide · unsecureDOOR 1L ESCAPE SLIDE FELL OUT OF CASE WHEN DOOR WAS OPENED. RII01983 SAFETY PINED SLIDE COMPLIED WITH VISUAL INSP OF SLIDE NO DISCREPANCIES. REINSTALLED, OPERATIONS CHECKED IAW AMM 25-66-01. SLIDE SAFETY PIN STOWED IN SLIDE PACK STOWAGE COMPARTMENT, AIRCRAFSDR USAA2013123000007Slide Raft · bindingFORWARD ENTRY DOOR GUST LOCK BUTTON VERY STIFF & HARD TO RELEASE. REPLACED L1 DOOR SLIDE RAFT IAW JOB CARD 26L00002501.SDR CALA2013123094028Slide · defectiveDOOR SLIDE PRESS GAUGE DOOR 1R NOT VISIBLE. R & R DOOR R1 ESCAPE SLIDE IAW AMM TASKS 25-62-44-00-002-A & 25-62-44-400-006-A.SDR USAA2013122700011Decoder · inoperativeSLIDE PRESS CAUTION LIGHT ON CIDS PANEL. REPLACED DECODER ENCODER UNIT.SDR CALA2013122693936Battery · failedEMERGENCY ESCAPE TEST 1 FAILED TO TEST. REPLACED RT OVERWING ESCAPE BAT IAW 25-65-17, OPERATIONS CHECKED GOOD.SDR SWAA2013122623638Slide · looseL2 DOOR SLIDE LOOSE. REINSTALLED SLIDE ASSEMBLY IAW MT.SDR FDEA201312233029Indicator · failedON WALK AROUND, FOUND L1 DOOR PRESSURE PUSH TO TEST LIGHT INOPERATIVE. REMOVED AND REPLACED REMOTE SLIDE PRESSURE INDICATOR ASSY. IAW AMM 25-61-03-2, OPS CHECKED NORMAL.SDR DALA13071943716Slide · no testDURING DEPLOYMENT TEST, THE R1 ESCAPE SLIDE FAILED TO DEPLOY. MAINTENANCE REPLACED DOOR R1 ESCAPE SLIDE ASSY IAW AMDS 2560-44-25.
Back to JASC 2565