SDR SWAA2013070317903Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR UALA2013070204643Cable · detachedLEFT OVERWING EMERGENCY ESCAPE SLIDE RELEASE CABLE FOUND NOT ATTACHED TO SLIDE. REPLACED SLIDE.SDR UALA2013070204642Slide · damagedRIGHT OVERWING SLIDE LACING HAS COME LOOSE. R & R RT OVERWING SLIDE IAW AMM 25-65-01.SDR R61A201307010580Bolt · corrodedDURING HEAVY CHECK, FOUND AFT PAX DOOR EVACUATION SLIDE LOWER ATTACH MOUNT HARDWARE CORRODED. MX R & R HARDWARE IAW AMM 20-10-01.SDR USAA2013070300007Reservoir · low pressure2S CHECK - LT SIDE OFF-WING ESCAPE SLIDE INFLATION RESERVOIR (7506MM) GAGE BELOW GREEN "GO" BAND. REPLACED LT SIDE OFF-WING ESCAPE SLIDE INFLATION RESERVOIR IAW AMM 25-62-46.SDR SWAA2013070317884Slide · out of positionR 2 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF CONTAINER, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR UALA2013070204638Slide · failedL1 DOOR EMERGENCY SLIDE FAILS DURING EMERGENCY LIGHT TEST. MESSAGE L1 DOOR EXTERNAL LOADS. TROUBLESHOT USING SIMULATOR AND WITH SIMULATOR LOAD INSTALLED, TEST PASSES WITH SLIDE CONNECTED TEST FAILS. REPLACED SLIDE IAW MM. TESTS NORMAL AND OPS CHECKED NORMALSDR UALA2013070104594Cover · unsecureL2 DOOR SLIDE PACK COVER BOTTOM HALF, IS UNATTACHED AND LOOSE. SECURED BUSTLE.SDR FDEA201306291418Slide · unwanted deployDOOR SLIDE ACCIDENTLY DEPLOYED ON DOOR OPENING. REMOVED AND REPLACED R-1 DOOR SLIDE IAW MM 25-66-01-4. OK FOR SERVICE.SDR UALA2013070104592Bottle · low pressureL2 DOOR SLIDE BOTTLE CHARGE LOOKS AS IF IT IS IN THE RED. REPLACED 2L SLIDE IAW AMM, OPS CHECKED GOOD.SDR UALA2013070104587Lanyard · unsecureLANYARD HANGING FROM SLIDE PACK AT DOOR 2L. STOWED LANYARD AT SLIDE PACK AT DOOR 2L.SDR SWAA2013070117768Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R&R SLIDE PER M/M.SDR AALA20130629001Slide · unwanted deployRT NR 1 DOOR WAS OPENED BY CLEANERS & THE SLIDE FELL FROM DOOR & DEPLOYED WHEN IT STRUCK THE GROUND. REPLACED RIGHT NUMBER 1 DOOR SLIDE. OPERATIONS CHECKED NORMAL.SDR FDEA201306291415Battery · failedFOUND R1 ENTRY DOOR SLIDE REMOTE PRESSURE INDICATOR PRESS TO TEST LIGHT OUT. REPLACED REMOTE PRESSURE INDICATOR BATTERIES REF AMM 25-61-04-4. OPS CHECKS GOOD REF AMM 25-61-04-5.SDR DALA13032721612Battery · inoperativeDURING CHECK, FOUND OFF WING ESCAPE EMERGENCY TEST OF SQUIB NOT SUCCEED. R & R BOTH LT AND RT BATTERYS OF ESC SYS OFF WING IAW AMM 25-65 AND OPS CHECKED OK.SDR UIEA2013071700389Slide · no testL3 DOOR OVERWING SLIDE FAILED TO DEPLOY SUCCESSFULLY DURING AN INADVERTENT DEPLOYMENT. (OUTSIDE SERVICE) REPACKED L3 DOOR SLIDE IAW CMM 25-65-05, REV 11. L3 DOOR SLIDE REINSTALLED IAW AMM 25-65-16-404-022.SDR USAA2013070100016Slide · defectiveSLIDE PRESSURE 4L DOOR DISPLAYED ON CIDS PANEL. R & R 4L DOOR SLIDE.SDR SWAA2013070117746Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA2013062817718Slide · unwanted deployL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. R&R SLIDE IAW MT.SDR DALA13032231612Battery · inoperativeEMERGENCY ESCAPE SQUIB WILL NOT TEST. REPLACED RT EMERGENCY ESCAPE SLIDE BATTERY, PN AD 2013-1A IAW AMM, OPS NORMAL.SDR SWAA2013062817717Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE IAW M/M.SDR SWAA2013062717664Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW TASK CARD.SDR GTIA20130625364Slide · underservicedREMOVED L1, DOOR ESCAPE PACK-ASSY FOR MX. RE-INSTALLED L1 ESCAPE SLIDE RAFT PACK ASSY PER ACFT MM, OPS TEST OK.SDR USAA2013062700009Slide Raft · unsecureLEFT REAR PAX DOOR SLIDE MECHANISM CAME OFF OF DOOR. REPLACED L2 DOOR SLIDE RAFT.SDR UALA2013062604466Lens · damagedL1 DOOR SLIDE PACK VIEW PORT OBSTRUCTED. FOUND LENS HAZED. REMOVED AND REPLACED LENS, SLIDE BOTTLE PSI CAN BE VERIFIED AS NORMAL.SDR USAA2013062700002Slide · out of positionL4 DOOR SLIDE DROPPED OUT OF BRACKETS. THE SLIDE WAS REMOVED AND THE ACFT WAS FERRIED, WHERE MX INSTALLED A NEW SLIDE. UNIT WAS DISASSEMBLED, CLEANED, INSPECTED, TESTED & OVERHAULED.SDR DALA13031329262Pin · missingDURING L1 DOOR MOUNTED ESCAPE SLIDE INSPECTION, WC 2561-01358-02A, SLIDE WAS FOUND TO BE MISSING SAFETY THREAD FROM THE LOWER PARACHUTE PIN IAW CMM PUB44608. R & R L1 DOOR SLIDE IAW AMM. RII COMPLIED WITH QC2084.SDR SWAA2013062417457Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R&R SLIDE IAW MT.SDR DALA13031369262Slide · inoperativeDURING L2 DOOR MOUNTED ESCAPE SLIDE INSPECTION, FOUND TO BE MISSING SAFETY THREAD FROM LOWER PARACHUTE PIN IAW CMM 460100. REMOVED AND REPLACED SLIDE. SAFETIED CORRECTLY OK FOR SERVICE.SDR USAA2013062400006Reservoir · inoperativeF/A CONTROL PANEL MESSAGE "CHECK SLIDE PRESSURE 3L" NOT READING ON GROUND. REMOVED AND REPLACED DOOR 3L SLIDE BOTTLE IAW MM 25-62-49. VENDOR TEARDOWN CONFIRMED FAILURE OF THE RESERVOIR.SDR SWAA2013062717680Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MM.SDR SWAA2013062517523Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE IAW AMM.SDR SWAA2013062417458Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. R&R SLIDE PER MM.SDR SWAA2013062417454Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE PACK FELL OUT OF COMPARTMENT, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR UALA2013062104323Light · faultySLIDE ARMED LIGHT IS NOT COMING ON DOOR 4L. REPLACED LAMP, NO HELP.SDR USAA2013062000004Cover · faultyL1 DOOR SLIDE COVER LOOSE. DOOR ALSO DOES NOT OPEN FULLY. REMOVED AND INSTALLED L1 DOOR SLIDE.SDR UALA2013061904239Container · crackedLEFT OVERWING ESCAPE SLIDE CONTAINER IS CRACKED 6.5 INCHES IN AREA TWO IAW MT 25-018. REPLACED LT OVERWING ESCAPE SLIDE IAW AMM, CHECKED GOOD.SDR USAA2013062000008Clamp · brokenLEFT OVERWING SLIDE BOTTLE FWD CLAMP BROKEN. REPLACED CLAMP.SDR USAA2013062000006Slide · faultyL2 DOOR WOULD NOT ARM. REPLACED L2 DOOR SLIDE AS REQUIRED.SDR DALA13031870959Slide · misinstalledINSPECTION DISCOVERED THAT THE EMERGENCY ESCAPE SLIDE IN THE TAILCONE HAD AN IMPROPERLY INSTALLED COVER. THIS WOULD PREVENT PROPER DEPLOYMENT OF THE ESCAPE SLIDE AND IS NOT IN COMPLIANCE WITH 14 CFR PART 121.703. THE TAILCONE SLIDE, COVER, AND LANYARDS WERE RSDR R61A201306180546Slide · defectiveFA WAS HAVING TROUBLE CLOSING THE R2 DOOR. MX FOUND THE LACES ON THE SLIDE BAG ARE PULLED AND THE SLIDE IS FALLING OUT OF THE BAG. MX DEPLOYED THE SLIDE SO THE ACFT COULD BE FLOWN VIA MX FERRY. MX FOUND THE FLEXBALL KIT CABLE WAS BROKEN WHICH CAUSED THE GIRTSDR USAA2013061900011Slide · unserviceableMX REPORTED THE L2 DOOR WOULD NOT ARM. MX REPLACED THE L2 DOOR SLIDE AS REQUIRED IAW JOB CARD 26L00025010.SDR USAA2013061900010Slide · crackedRIGHT OVERWING SLIDE HAS VERTICAL CRACK APPROX. 8" LONG. REPLACED SLIDE.SDR USAA2013061900008Slide · contaminatedRIGHT SIDE OFF WING ESCAPE SLIDE HAS WATER DRAINING OUT OF BOTTOM FWD AFT END. REPLACED RT SIDE OFF WING ESCAPE SLIDE.SDR UALA2013062004290Cover · damagedR1 DOOR SLIDE RAFT COVER DAMAGED. COMPLIED WITH EC RA 5211-01348 REQUIREMENTS. TAPE APPLIED AS INTERIM.SDR UALA2013061704176Cover · misinstalledL2 DOOR SLIDE COVER DOES NOT APPEAR TO BE INSTALLED CORRECTLY. INSTALLED DOOR SLIDE COVER REF AMM 25-62-44.SDR SWAA2013061917342Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF CASE, DID NOT DEPLOY, STILL OPERATIONAL. REINSTALLED SLIDE IAW MT.SDR UIEA2013061800336Bottle · low pressureL3 DOOR SLIDE HAS LOW PRESSURE. REMOVED & REPLACED ESCAPE SLIDE ON L3 DOOR IAW AMM 25-69-01. ALL OPS NORMAL.SDR CALA2013082790801Bottle · unknownCABIN INTERPHONE DISTRIBUTION SYSTEM PANEL LIGHT ON. INTERROGATED PTP PANEL SHOWS LT OVERWING EXIT BOTTLE PRESSURE. FOUND BOTTLE PRESSURE TWO NEEDLES IN THE GREEN. REPLACED LEFT OVERWING SLIDE INFLATION RESERVIOR PER AMM.SDR UALA2013061704171Bottle · unknownF/A SAYS CIDS PANEL LIGHT ON. INTERROGATION OF PTP PANEL SHOWS LT OVERWING EXIT BOTTLE PRESSURE. FOUND BOTTLE PRESSURE NEEDLES IN THE GREEN. REPLACED LT OVERWING SLIDE INFLATION RESERVOIR IAW AMM. ACCOMPLISHED FINAL INSTALLATION CHECK. BITE TEST OK.
Back to JASC 2565