Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201305301140Latch · brokenDOOR ESCAPE SLIDE COVER LOWER STRAP LATCH BROKEN. REPLACED LATCH IAW AMM 25-66-01-4. ACFT OK FOR SERVICE.SDR UALA2013053003753Hose · deterioratedRIGHT OVERWING ESCAPE SLIDE INFLATION HOSE PROTECTIVE FOAM DETERIORATED. R & R SLIDE ASSY.SDR SWAA2013053016628Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MM.SDR WX0A071600Slide · unserviceableR1 DOOR EVACUATION SLIDE NEEDLE IS IN THE RED. REMOVED AND REPLACDE R1 DOOR EVACUATION SLIDE.SDR SWAA2013052916579Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT. REINSTALLED SLIDE IAW MM.SDR SWAA2013052816539Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR UALA2013052803707Lamp · faultyR1 DOOR SLIDE ARMED LIGHT DID NOT ILLUM WHEN ARMED. REPLACED LAMP, OPS GOOD.SDR UALA2013052803706Bottle · dischargedR2 DOOR SLIDE PRESSURE IN RED. REMOVED AND REPLACED R2 DOOR ASSIST BOTTLE AS PER AMM.SDR SWAA2013052816533Slide · out of limitsR2 DOOR EMERGENCY EVAC SLIDE ASSY PRESSURE OUT OF LIMITS. R & R SLIDE ASSY IAW MT.SDR IPXA3M78560Pressure Gauge · contaminatedR1 DOOR SLIDE PRESSURE GAUGE CONTAMINATED WITH MOISTURE. ILLEGIBLE. DEFERRED IAW MEL 52-10-3-2. PLACARD INSTALLED. LOG UPDATED. R & R R1 DOOR PNEUMATIC STORAGE RESERVOIR PRESSURE GAUGE AND RELIEF VALVE REF AMM 52-11-04 AND IPC 52-11-35-01. THIS CLEARS M505SDR USAA2013052800004Slide Raft · faultyCIDS ESCAPE SLIDE LT SW/EPSU 1R (12WL) FAULT. R & R 1R ESCAPE FACILITIES. OP'S CHECKS NORMAL.SDR UALA2013052303587Cover · crackedR2 DOOR SLIDE DECORATIVE COVER HAS A 14 INCH CRACK HORIZONTALLY IN OUTER LAYER 4 INCHES FROM BOTTOM. ALSO, HAS 4 INCH CRACK IN OUTER LAYER EXTENDING 4 INCHES VERTICALLY. VISUAL INSPECTION ACCOMPLISHED, NO ADDITIONAL DAMAGE. BUSTLE IS RIGID. INSTALLED ONE 8SDR SWAA2013052416450Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE IAW MM.SDR R61A201305220483Slide · defectiveCREW REPORTED THAT THE R2 DOOR WILL NOT ARM. MX FOUND THAT THE SLIDE WILL HAVE TO BE CHANGED. DURING SLIDE CHANGE, MX FOUND CABLE TO R2 DOOR GIRT BAR DAMAGED AND WILL HAVE TO BE CHANGED. MX R & R SLIDE AND FLEXBALL KIT IAW AMM AND OPS CHECKED GOOD.SDR USAA2013052300006Slide Raft · low pressureDURING ACCOMPLISHMENT OF WEEKLY CHECK, FOUND L2 DOOR SLIDE BOTTLE PSI LOW IN RED BAND. SLIDE IS REMOVED. REPLACED L2 DOOR SLIDE/RAFT.SDR USAA2013052300002Slide · unsecureWHEN F/A OPENED ENTRY DOOR, SLIDE PACK FELL OUT OF BOTTOM AND RESTED ON JETWAY FLOOR. IT DID NOT INFLATE-GIRT BAR WAS DISARMED. MX REPLACED L1 DOOR SLIDE PACK IAW AMM 25-61-35-402-007.SDR UALA2013052303585Shroud · crackedRIGHT OVERWING SLIDE CRACKED SHROUD. REPLACED UNIT.SDR DALA13024249217Pin · out of positionDURING ROUTINE INSPECTION, L1 DOOR SLIDE PINS WERE FOUND OUT OF POSITION. THE SLIDE WAS REPLACED IAW TC 2500-4332.SDR SWAA2013052216337Slide · failedR1 DOOR EMERGENCY EVAC SLIDE FAILED OPS CHECK. R & R SLIDE IAW MM.SDR SWAA2013052216333Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW SIP.SDR DALA13024040964Slide · damagedDURING LINE INSPECTION, THE NR 1 LT DOOR SLIDE WAS NOTED TO BE DAMAGED. THE TYPE OR SPECIFIC DAMAGE WAS NOT CLEARLY IDENTIFIED IN THE LOGBOOK DISCREPANCY. THE SLIDE WAS REPLACED USING JOB INSTRUCTION CARD 2500-4484 AND THE REQUIRED INSPECTION WAS COMPLETED.SDR DALA13024039019Pin · looseDURING ROUTINE INSPECTION, THE INSPECTOR NOTED THAT THE NR 1 LEFT DOOR SLIDE PACKING PIN WAS LOOSE. THE SLIDE WAS REPLACED IAW AMM 25-62 AND THE REQUIRED INSPECTION WAS COMPLETED.SDR DALA13024020979Pin · missingDURING ROUTINE INSPECTION, THE INSPECTOR NOTED DURING PRE-FLIGHT THAT THE NR 1 LT DOOR SLIDE PINS WERE OUT. THE DOCUMENTED COMMENTS ARE NOT SUFFICIENT TO VERIFY THE SPECIFIC PINS IDENTIFIED. THE SLIDE WAS REPLACED ON AMDS WC 2500-4484 AND THE REQUIRED INSPECSDR USAA2013052200005Bottle · low pressureF/A REPORTS DOOR 3R CHECK PRESSURE AMBER LIGHT ON. DOOR WAS ARMED. R & R R3 DOOR SLIDE BOTTLE IAW MM 25-62-49-0401-A.SDR USAA2013052200004Slide Raft · low pressureMX REPORTED THE L2 SLIDE RAFT BOTTLE PRESSURE NOT IN GREEN BAND. MX R & R THE L2 SLIDE RAFT ASSY IAW JOB CARD.SDR DALA2017101007400Lamp · inoperativeL4 ENTRY DOOR SLIDE LIGHT ARMING INDICATOR INOPERATIVE. REPLACED THE LAMP. CHECKED GIRT BAR ENGAGEMENT. LAMP AND GIRT BAR FUNCTION OK. OK FOR SERVICE.SDR WX0A071581Slide · unwanted deployL2 DOOR SLIDE DEPLOYED BY CLEANER. DOOR WAS NOT DISARMED - CREW ERROR. REPLACED L2 DOOR SLIDE PER TASK CARD.SDR SWAA2013052316439Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW MM.SDR SWAA2013052016196Slide · unwanted deployR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. R & R SLIDE IAW MM.SDR SWAA2013052016233Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE IAW AMM.SDR IPXA13M78430Gauge · out of positionNR 1 DOOR SLIDE PRESSURE INDICATOR NOT READABLE. APPEARS SLIDE PACK HAS SHIFTED DOWN AND PRESSURE GAUGE IS NOT READABLE. REPOSITIONED AS MUSH AS POSSIBLE TO ALIGN PRESS GAUGE WITH INSPECTION. GAUGE IS NOW VIEWABLE THROUGH WINDOW REF AMM 25-23-07-401, 25-61-SDR SWAA2013052016223Slide · failedR1 DOOR EMERGENCY EVAC SLIDE OPS TEST WAS UNSUCCESSFUL. R & R SLIDE IAW MT AND MM.SDR UALA2013051703425Slide · deployedESCAPE SLIDE AT R2 DOOR HAS BEEN DEPLOYED ON TO RAMP. CSDR GTIA20130516608Slide · faultedERSU TEST SHOWS ESCAPE SLIDE LT/ EPSU (10WL) FWD FAULT IAW TSM. R & R L1 ESCAPE SLIDE ASSY IAW ACFT MM.SDR DALA13023913119Lanyard · damagedDOOR 1 LT SLIDE DISARM PIN LANYARD DAMAGED.SDR DALA13023369248Lanyard · frayedTAILCONE SLIDE LANYARD FRAYED. R & R TAILCONE SLIDE LANYARD IAW AMM.SDR DALA13023359248Lanyard · frayedTAILCONE SLIDE LANYARD FRAYED. R & R TAILCONE SLIDE LANYARD IAW AMM.SDR FDEA201305151006Slide · dislodgedCREW REPORTED R1 DOOR SLIDE PARTIALLY DROPPED. REPOSITIONED SLIDE IAW MM:25-66-01-4. ALSO FOUND EMERGENCY RESERVOIR EMPTY. R & R SAME IAW MM:52-11-30-4. ALL CHECKED OK. ACFT OK TO CONTINUE.SDR GTIA20130515606Bottle · low pressureINSPECT R1 DOOR SLIDE PACK FOR PROPPER BOTTLE PRESSURE. INSPECTED R1 DOOR SLIDE BOTTLE PSI INDICATOR. BOTTLE PSI INDICATES LOW SIDE OF GREEN BAND AC OK FOR SVC IAW ACFT MM.SDR DALA13022669004Pin · out of positionDURING A ROUTINE LINE CHECK, MECHANIC NOTICED THAT THE SLIDE INFLATION PIN WAS NOT VISIBLE THROUGH THE PRESSURE GAUGE WINDOW. L1 DOOR SLIDE REPLACED IAW WC 2500-4484.SDR SWAA2013051616120Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE PRESSURE PRESSURE LOW. REMOVED AND REPLACED SLIDE IAW MT.SDR SWAA2013051416025Cable · looseL2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED CABLE PER MM.SDR SWAA2013051415992Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR UALA2013051303307Static Line · unsecureR1 DOOR SLIDE HANDLE DIFFICULT TO MOVE. SECURED LOOSE STATIC LINE IN PROPER POUCH IAW AMM SERVICE TIP 25-66-01.SDR UALA2013051303325Slide · low pressureL1 DOOR SLIDE PRESSURE IS NOT IN GREEN BAND. R & R L1 SLIDE IAW AMM 25-66-01. OPS CHECKED NORMAL.SDR UALA2013051303313Proximity Switch · inoperativeLEFT AFT SLIDE INDICATION INOPERATIVE ON DOOR OXYGEN SYS ECAM PAGE. SLIDE INDICATION SHOWED ARM AT THE GATE. IAW CREW DOOR 2L SLIDE ARMED INDICATION OUT IN CRUISE AND REARMED ITSELF ON DESCENT THRU 15,000 MSL. CABIN PRESS DELTA 4.8 PSI CABIN ALT 3100' -ADJUSDR DALA13022330990Slide · dislodgedUPON ARRIVAL, THE 1L DOOR SLIDE CAME OUT OF THE SLIDE PACK AND DID NOT INFLATE. IT WAS NOTED THAT THE GIRT BAR WAS NOT ENGAGED WHEN THE SLIDE CAME OUT OF THE PACK. THE 1L SLIDE WAS REPLACED IAW WC 2500-4484 AND THE REQUIRED INSPECTION WAS COMPLETED.SDR SWAA2013051616096Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT DID NOT DEPLOY. SECURED SLIDE PER MT.SDR SWAA2013051315915Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER M/M.SDR FDEA201305110972Slide · looseL1 MAIN ENTRY DOOR SLIDE WAS FOUND LOOSE IN THE SLIDE COVER. REMOVED & REINSTALLED L1 DOOR SLIDE ASSY IAW AMM 25-60-015-2. OK FOR SERVICE.
Back to JASC 2565