SDR IPXA12M76046Lamp · inoperativeR1 DOOR SLIDE LIGHT DOES NOT ILLUMINATE WHEN PUSHED. LAMPED R1 DOOR EVAC SLIDE REMOTE PUSH TO TEST PRESS IND SWITCH. OPS CHECKS NORMAL IAW MM 25-6-104. THIS CLEARS M490654.SDR FDEA201210213709Slide · failedMAIN CABIN DOOR SLIDE ACTIVATED. CAPT/FO, BOTH VERIFIED DOOR(S) WERE DISARMED BUT SLIDE ACTIVATED, DOOR SYNOPSIS INDICATED "M" ON BOTH DOORS. REMOVED LT DOOR MOUNTED ESCAPE SLIDE IAW AMM 25-66-00 201, AND LT CREW DOOR CLOSED EASILY. INSTALLED LT ENTRY DOSDR USAA2012102200026Bottle · low pressureDOOR 2R SLIDE BOTTLE IN RED. REMOVED AND REPLACED DOOR 2R SLIDE BOTTLE IAW AIRBUS MAINTENANCE MANUAL 25-62-49.SDR UALA2012102306054Slide · unserviceableLEFT OFF-WING SLIDE ENCLOSURE PANEL BALL LOCKS ARE PAINTED. SLIDE NEEDS TO BE REPLACED. (REF AMM 25-62-42 -401, MT 25-029, AND M&E BULLETIN 12-011. REPLACED SLIDE AND OPS CHECKED.SDR UALA2012101905995Slide · low pressureSLIDE 1R PRESSURE LOW. REPLACED NR 1 RIGHT MED SLIDE PER MM.SDR SWAA2012102308704Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR USAA2012102200009Slide · defectiveC11/SY6 CHECK - SUSPECTED PARTIAL OPENING OF L1 DOOR ESCAPE SLIDE. REPLACED L1 DOOR ESCAPE SLIDE IAW JOB CARD 26L00025010.SDR USAA2012101900001Slide · brokenC11 CHECK - UPON REMOVAL OF EMERGENCY SLIDE ON R-2 DOOR FOUND MOORING LINE BROKEN. REPLACED R2 DOOR SLIDE IAW EA 104291 & JOB CARD 26L00025010.SDR SWAA2012101908666Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT AND MM.SDR SWAA2012101908663Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE COVER FELL OUT, DID NOT DEPLOY, STILL OPERATIONAL. RE-INSTALLED SLIDE PER MT.SDR SWAA2012101808644Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER M/M.SDR SWAA2012101808640Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR USAA2012101700001Hose · worn2S CHECK - LEFT OVERWING ESCAPE SLIDE ENCLOSURE INFLATION HOSE WORN. REPLACED LEFT OVERWING ESCAPE SLIDE IAW JOB CARD 26C19053012.SDR R61A201210160586Slide · partial deployCREW REPORTED THAT THE F/A OPENED THE L1 DOOR WHILE IT WAS STILL ARMED AND PARTIALLY BLEW THE EMERGENCY SLIDE. MAINTENANCE REPLACED THE SLIDE ASSY PER EMB AMM.SDR FDEA201210163630Cover · unsecureBOTH ENTRY DOORS SLIDE COVERS NOT ATTACHED AT BOTTOM. SECURED BOTH ENTRY DOOR SLIDE COVER REF AMM 25-66-01-4.SDR FDEA201210163629Slide · dislodgedESCAPE SLIDE CAME OUT OF ITS COMPARTMENT WHEN OPENING FORWARD ENTRY DOOR. INSTALLED ENTRY DOOR ESCAPE SLIDE IAW AMM 25-60-015-2.SDR SWAA2012101708606Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF CARRIER, DID NOT DEPLOY, STILL OPERATIONAL. RE-INSTALLED SLIDE PER MT.SDR USAA2012101600004Slide · low pressure2S CHECK - LOW PRESSURE IN RESERVOIR OF ESCAPE SLIDE AT DOOR 832 (L2). REPLACED ESCAPE SLIDE AT DOOR 832 (L2) IAW JOB CARD 26C83252008.SDR USAA2012101600003Slide · unserviceable2S CHECK - OVER PRESSURE IN RESERVOIR OF ESCAPE SLIDE ON DOOR 842 (R2). REPLACED ESCAPE SLIDE PACK ASSEMBLY ON DOOR 842 (R2) IAW JOB CARD 26C84252006.SDR FDEA201210123603Slide · unwanted deployL1 DOOR SLIDE PARTIALLY DEPLOYED ON OPENING. R & R L1 SLIDE PER MM 25-66-01-4. CHECKED OK, ACFT OK FOR SERVICE.SDR SWAA2012101608556Pin · missingL2 DOOR EMERGENCY EVAC SLIDE DEACTIVATION PIN MISSING. INSTALLED PIN IAW AMM.SDR SWAA2012101508498Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR SWAA2012101508492Slide · looseR1 DOOR EMERGENCY EVAC SLIDE PACK LOOSE. SECURED SLIDE PER AMM.SDR FDEA201210123607Cover · unsecureL1 DOOR EXTREMELY HARD TO CLOSE AND ARM. COVER OVER SLIDE IS LOOSE. FOUND L1 SLIDE COVER NOT PROPERLY LATCHED AT TOP LEFT ATTACHMENT. PROPERLY INSTALLED COVER ASSY IAW AMM CH 52-11-02-4. DOOR OPERATES AND ARMS/DISARMS PROPERLY. OK TO CONTINUE.SDR UALA2012101205806Slide · crackedRIGHT OVERWING SLIDE PANEL IS CRACKED ON AFT EDGE. SLIDE REMOVED AND PUT IN REAR PIT ALSO SEAL ATTACH PLATE AND HARDWARE ARE IN PIT. INSTALLED SERVICEABLE OFF-WING SLIDE.SDR SWAA2012101508500Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER M/M.SDR DALA12009895636Strap · shortL2 DOOR SLIDE HARNESS LWR LATCH STRAP FOUND TOO SHORT. L2 PAX DOOR SLIDE HARNESS R & R IAW AMM: 25-66-01, REV 104. RII INSPECTION COMPLETE.SDR DALA12009865636Spring · failedR2 DOOR GIRT BAR LEAF SPRING FAILED THE FUNCTION TEST IAW W/C 2561-01257-01D STEP 8. R2 PAX DOOR GIRT BAR R & R IAW AMM 25-66- 10, REV 104. R2 PAX DPPR GIRT BAR LEAF SPRING FUCNTIONAL TEST CARRIED OUT IAW W/C 2561-01257-01D FOUND SATISFACTORY. JOB COMPLETEDSDR DALA12010019002Lanyard · frayedR1 DOOR SLIDE LANYARD FRAYED. L1 DOOR SLIDE LANYARD ROUTED IMPROPERLY. REPLACE R1 DOOR SLIDE LANYARD. REROUTED L1 DOOR SLIDE LANYARD. ALL MX IAW 25-62.SDR SWAA2012101208464Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR CALA2012101000664Slide · unwanted deployL3 DOOR SLIDE DEPLOYED. REMOVED & REPLACED DOOR SLIDE IAW MM 25-66-01 & DOOR ASSIST BOTTLE IAW MM 52-11-22. ALL CHECKED GOOD.SDR SWAA2012112809967Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE IAW MT #G325-61-06.SDR UALA2012101005762Bottle · brokenLEFT OVERWING SLIDE BOTTLE BROKEN AT CABLE OUTLET. REMOVED AND REPLACED LT OVERWING SLIDE RESERVOIR. OP CHECKED GOOD.SDR UALA2012101005761Clamp · deterioratedRT WING EMERGENCY SLIDE HAS 3 DETERIORATED CLAMPS. REMOVED AND REPLACED OFF WING SLIDE ASSY RT WING. INSTALLATION COMPLETE.SDR SWAA2012101608555Pin · missingL1 DOOR EMERGENCY EVAC SLIDE MISSING SAFETY PIN. INSTALLED SAFETY PIN IAW AMM.SDR FDEA201210093588Bolt · looseL1 DOOR WILL NOT ARM. FOUND RT SIDE LOWER SLIDE PAN MOUNT BOLT LOOSE. TIGHTENED BOLT. RE-ROUTED SLIDE RETENTION CORD IAW AMM 25-66-01-4. OPS CHECKED GOOD.SDR SWAA2012101108428Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA2012101008373Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA2012101008395Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MT.SDR DALA12009555534Harness · deterioratedR4 DOOR EMERGENCY ESCAPE SLIDE HARNESS DETERIORATED AND WILL NOT LATCH. R & R R-4 DOOR EMERGENCY ESCAPE SLIDE HARNESS IAW -A-25-66-01-401-926-A-A.SDR UALA2012100805701Slide · faultyCHECK RIGHT OFF WING SLIDE OP. ACCOMPLISH OPERATIONAL CHECK OF THE RIGHT OFF WING ESCAPE SLIDE, PCN 649-9124 MR25722, PER MM. SLIDE DID NOT DEPLOY PROPERLY.SDR FDEA201210043549Slide · failedRIGHT ENTRY DOOR DID NOT PROPERLY DISARM. SLIDE DID NOT INFLATE. R & R RT EMERGENCY POWER RESERVOIR IAW MM 52-11-30-4 AND CK IAW MM 52-11-30-6, ALL CK OK. PLACARD REMOVED, ACFT OK TO CONTINUE.SDR I5EA2012F00190Slide · no testDURING C CHECK AN ATTEMPT TO ACCOMPLISH SWIFT AIR ROUTINE OPS CHECK OF ESCAPE SLIDE SYS, THE L2 DOOR WAS SELECTED FOR DEPLOYMENT. WITH THE SLIDE IN PLACE AND THE GIRT BAR INSTALLED, THE DOOR WAS OPENED BUT THE SLIDE FAILED TO INFLATE. UPON INVESTIGATION OF THESDR SWAA2012100908354Slide · out of positionR2 DOOR SLIDE GAUGE IS OUT OF POSITION IN VIEWING WINDOW. REPOSITIONED SLIDE ASSY PER MT.SDR USAA2012100500028Slide · faultyEMERGENCY LIGHTS FAILED TEST, FAULTING AFT LEFT EXTERNAL LIGHTS. REPLACED AFT LEFT ESCAPE SLIDE.SDR SWAA2012100408270Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA2012100308228Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR DALA1249681609Latch · brokenDURING PSV 10, RIGHT OVERWING SLIDE DOOR FAILED TORQUE CHECK. UNABLE TO OPEN OVERWING DOOR INITIALLY. APPLIED PRESSURE TO DOOR AND WORKED INTEGRATOR BACK AND FORTH, UNTIL THE DOOR UNLATCHED. ON INVESTIGATION, FOUND THE THIRD LATCH WAS BROKEN, SPRING WAS MISSSDR SWAA2012100408258Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER M/M.SDR SWAA2012100408257Lens · looseR2 DOOR EMERGENCY EVAC SLIDE LENS LOOSE. REMOVED AND REPLACED LENS PER AMM & MT.
Back to JASC 2565