Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011071500030Relay · faultyL1 DOOR SLIDE WILL NOT ARM. SLIDE INDICATION ON DOOR PAGE WAS BLANK. REMOVED AND REPLACED THE POWER SUPPLY SWITCH OVER RELAY. OPERATIONAL CHECKED NORMAL.SDR SWAA115066Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE PER MT.SDR USAA2011071500001Slide · low pressurePHL - L-1 SLIDE PRESSURE LOW. MAINTENANCE REMOVED AND REPLACED L1 SLIDE AS PER JOB CARD 19L80025002.SDR USAA2011071400003Slide · faultyS2 CHECK - R1 DOOR FAILED EXTERNAL LOAD FAULT ON 10WL ESPU. REPLACED R1 DOOR SLIDE AFTER TROUBLESHOOTING IAW JOB CARD 26L00025010.SDR ZZDA2011588Lanyard · detachedGALLEY DOOR SLIDE PIN CAME OFF. R-1 RE-ATTACH GALLEY DOOR SLIDE LANYARD IAW AMM 25-61-03. OK FOR SERVICE.SDR USAA2011071300006Bottle · low pressureMAINTENANCE REPORTED THE L1 DOOR ESCAPE SLIDE PRESSURE GAUGE NEEDLE WAS OUTSIDE OF THE GREEN BAND. MAINTENANCE REMOVED AND REPLACED THE L1 DOOR ESCAPE SLIDE IAW J/C 03T10025002.SDR SWAA115079Slide · unserviceableDURING SCHEDULED MV1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GAUGE OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA115047Slide · unserviceableR1 DOOR EMERGENCY EVAC SLIDE PARTIALLY PULLED OUT OF CONTAINER. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA115015Slide · out of adjustDURING SCHEDULED 12Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE IAW MM AND MT.SDR SWAA115000Slide · out of positionDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSTIONED SLIDE PER MM.SDR FDEA201107122645Lamp · inoperativeL1 DOOR DISARMED LIGHT INOP. RELAMPED AS REQUIRED IAW MM 33-00-00-2-0. OPS CHECK GOOD.SDR DALA1143320927Lanyard · disconnectedDURING LINE CHECK MAINTENANCE FOUND R1 DOOR LANYARD NOT ATTACHED TO GIRT BAR. MAINTENANCE INSTALLED R1 DOOR SLIDE LANYARD PER MM 25-62-00. OK FOR SERVICE.SDR ZZDA2011585Lanyard · brokenR1 DOOR ESCAPE SLIDE LANYARD IS BROKEN. REMOVED AND REPLACED BROKEN R-1 DOOR SLIDE GIRT LANYARD AS OUTLINED IN 717 M/M 25-61 AWI.SDR SWAA114954Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MM.SDR SWAA2012080806583Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA114986Slide · out of positionDURING SCHEDULED MV1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR DALA1143310920Lanyard · disconnectedCREW FOUND L2 GIRT BAR LANYARD DISCONNECTED. CONTRACT MAINTENANCE RE-INSTALLED LANYARD PER AMM 25-62-00-201 ON L2 DOOR. DOOR OK FOR SERVICE.SDR USAA2011071100034Cylinder · low pressureTHE 4L SLIDE "CHECK PRESSURE" LIGHT ON AS IT WAS ARMED. MAINTENANCE SERVICED DOOR ASSIST WITH NITROGEN.SDR UALA2011070803400Slide · unserviceableFOUND LT OFF WING SLIDE WITH PAINT IN ALL 3 BALL LOCK PINS. FOUND PER EG5371 AND MM PAGE 420. LT OVERWING SLIDE IS PCN 649-9000. REPLACED LT OVERWING SLIDE ASSY PER MM.SDR SWAA114919Slide · low pressureDURING SCHEDULED MV2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LOW PRESSURE. REMOVED AND REPLACED SLIDE PER MT.SDR USAA2011071100020Bottle · low pressureMAINTENANCE REPORTED THE L1 DOOR ESCAPE SLIDE BOTTLE PRESSURE WAS LOW. MAINTENANCE REMOVED AND REPLACED THE L1 DOOR ESCAPE SLIDE PER AMM 25-61-35-002-001 AND 25-61-35-402-003.SDR ZZDA2011580Slide · out of positionL1 SLIDE FELL ONTO JET BRIDGE. INSTALLED NEW SLIDE IAW 25-61 AMM AWI REQ & C/W.SDR UALA2011070803394Cap · shortedOFF WING ESCAPE SLIDE RT SYS PRESS BOTTLE SQUIB DISCONNECTED AND SHORTING CAP INSTALLED AND SAFETY PIN INSTALLED IN MASTER CONTROL VALVE. REINSTALLED CONN AND REMOVED PIN AND SHORTING CAP PER MM. ACCOMPLISHED INSPECTION PIN REMOVED AND STOW PRESSURE GOOD.SDR UALA2011070803402Aspirator · faultySLIDE RECEIVED WITH VACUUM CAP STILL ATTACHED TO ASPIRATOR. CAUSE AND CORRECTIVE ACTION: UPON DISASSEMBLY, FOUND THE VACUUM CAP ATTACHED THAT WAS USED TO DEFLATE THE SLIDE AND MAINTAIN A VACUUM DURING PACK. VACUUM CAP IS TO BE REMOVED WHEN PACKING IS COMPLETE.SDR SWAA114900Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-INSTALLED SLIDE IAW MT.SDR SWAA114896Attach Bracket · looseDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE UPPER AFT ATTACH BRACKET LOOSE. SECURED BRACKET PER MM.SDR FDEA201107072607Switch · failedOPEN RT FOUND EMERGENCY SLIDE LIGHT SWITCH CABLE BALL OUT OF SOCKET. LIGHT EXTINGUISHED. TRIED NEW BATTERY PACK, NO HELP. REINSTALLED ORIGINAL BATTERY PACK IAW MM 33-50-121-2. RELAMPED, NO HELP. REMOVED BATTERY & CHECKED WIRING AT BATTTERY CONNECTORS, SHOWSDR IPXA1167752Slide · unserviceableCREW ENTRANCE DOOR WILL NOT ARM. REMOVED MAIN CABIN DOOR SLIDE IAW DMP 52-11-01-3 AND MEL 52-11-01-3.SDR UALA2011070803392Hose · shearedSLIDE MR25823-2088 RECEIVED IN PACKED CONDITION. UPON DISASSEMBLY, FOUND INFLATION HOSE (P/N D37085-101) FITTING SHEARED AT ASPIRATOR. NO OTHER DISCREPANCIES NOTED. SUSPECT IMPROPER PACKING CAUSED FAILURE OF HOSE (P/N D37085-101) FITTING TO EXCESS PRESSURE SDR SWAA114841Slide · out of positionDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE IAW MT.SDR FDEA201107042563Sensor · failedR1 ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT INOPERATIVE. FOUND FWD GIRT BAR SENSOR AT FAULT (S10216). R & R R1 ESCAPE SLIDE GIRT BAR FORWARD SENSOR AND ACTUATOR IAW MM 25-66-11-2, OPS TESTED SERVICABLE.SDR SWAA2012080806586Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA114851Slide · looseDURING SCHEDULED OTS CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MT.SDR USAA2011070700001Bottle · low pressureDOOR 3L SLIDE TURNED AMBER (FLIGHT ATTENDANT CIDS PANEL). FOUND INFLATION RESERVOIR BOTTLE JUST BELOW GREEN BAND. REMOVED AND REPLACED INFLATION RESERVOIR BOTTLE AT DOOR 3L. CIDS TEST GOOD.SDR SWAA114825Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA2012080806585Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT OF CONTAINER, DID NOT DEPLOY, STILL OPERATIONAL. RE-INSTALLED SLIDE PER MT.SDR DALA1146710672Harness · wornR-1 SLIDE HARNESS WORN. REPLACE R-1 SLIDE HARNESS AT ST AEROSPACE SAN ANTONIO DURING HMV.SDR DALA1146700672Harness · wornR-4 SLIDE HARNESS WORN. REPLACE R-4 SLIDE HARNESS AT ST AEROSPACE SAN ANTONIO DURING HMV.SDR UALA2011070503279D-Ring · unsecureDOOR 1L SLIDE PACK D-RING NOT VISIBLE. SECURED D-RING AND SLIDE COVER.SDR USAA2011070600024Dampener · leakingTGC - L-2 DOOR EMERGENCY ASSIST BOTTLE HAS LOW PRESSURE. REMOVED AND REPLACED DIAPHRAGM ON L-2 EMERGENCY ASSIST BOTTLE AND SERVICED, LEAK CHECKS GOOD IAW A319 AMM 52-10-00-610-001.SDR SWAA114772Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR UALA2011070503277Line · out of positionWITH DOOR OPEN 3R SHOWS LINES-STRINGS HANGING OUT OF SLIDE PACK. REMOVED SHROUD. SECURE STRING. INSTALLED SHROUD. ARMED AND DISARMED DOOR. SATISFACTORY OPERATIONS.SDR SWAA114836Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA114798Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CASE, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA114827Slide · unserviceableR2 DOOR EMERGENCY EVAC SLIDE PULLED OUT OF CASE, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR DALA1142150955Lanyard · brokenCREW FOUND L1 DOOR SLIDE LANYARD BROKEN. MAINTENANCE REPLACED L1 DOOR SLIDE LANYARD PER AMM 25-62-00-201.SDR FDEA201106282479Indicator · inoperativeL1 EVAC SLIDE REMOTE PRESSURE INDICATOR INOPERATIVE. REMOVED & REPLACED L1 DOOR REMOTE SLIDE PACK PRESSURE INDICATOR IAW MM 25-61-03-2.OPS CHECK NORMAL.SDR USAA2011070100005Slide · failedLAS - EES - FAILED EMERGENCY LIGHT TEST - LEFT FORWARD EXTERNAL LIGHT. REMOVED AND REPLACED L1 DOOR SLIDE PER JOB CARD 26L00025010.SDR SWAA114683Slide · out of adjustL1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM AND MT.SDR SWAA114675Slide · inoperativeL2 DOOR EMERGENCY EVAC SLIDE INOP. REMOVED AND REPLACED SLIDE PER MT.
Back to JASC 2565