Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA112337Bracket · crackedDURING SCHEDULED 2HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT BRACKET CRACKED. REMOVED AND REPLACED BRACKET PER MM.SDR SWAA112336Bracket · crackedDURING SCHEDULED 2HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD BRACKET CRACKED. REMOVED AND REPLACED BRACKET PER MM.SDR SWAA112324Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA112321Window · looseDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GAUGE WINDOW LOOSE. REMOVED AND REPLACED WINDOW PER MM.SDR SWAA112277Cable · frayedDURING SCHEDULED 22Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA112276Cable · frayedDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA112246Slide · out of positionDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITONED SLIDE PER MT.SDR UALA2011032901493Slide · unwanted deployL-1 DOOR SLIDE INADVERTENTLY DEPLOYED. REPLACED L-1 DOOR SLIDE PER MM.SDR UALA2011032801477Slide · dischargedMAIN CABIN R-2 DOOR ESCAPE SLIDE HAS LOW PRESSURE. R-2 PASSENGER DOOR-MOUNTED ESCAPE SLIDE INFLATION BOTTLE PRESSURE HAS IMPROPER INFLATION. GAUGE NEEDLE IS BELOW (LEFT) OF GREEN BAND. REMOVED AND REPLACED R-2 DOOR SLIDE ASSY PER MM.SDR SWAA112300Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2011032801466Slide · damagedAFT ALIGNMENT PIN FOR OVERWING SLIDE ON RT DOOR BROKEN OFF. REMOVED RT OVERWING SLIDE.SDR UALA2011032501447Lamp · faultyDOOR 2L ARM LIGHT WILL NOT ILLUMINATE. REPLACED INOP LAMPS, CHECKS SATISFACTORY.SDR USAA2011032991271Slide · low pressureCLT - C4 - L-1 DOOR SLIDE BOTTLE PRESSURE LOW. REPLACED L-1 DOOR SLIDE IAW JOB CARD 03C10552002.SDR SWAA112171Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA112149Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA112131Slide · out of positionDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE LOWER FLAP OUT OF POSITION. REPOSITONED SLIDE PER MT.SDR SWAA112119Slide · out of adjustDURING SCHEDULED 24Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA112126Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. REMOVED AND REPLACED SLIDE ASSY PER MM AND MT.SDR ZZDA2011317Window · damagedTAIL CONE SLIDE ENCLOSURE VIEWING WINDOW HAS A HOLE IN IT AS WELL AS / SEVERAL CRACKS. REMOVED AND REPLACED AFT TAIL CONE SLIDE AS PER AMM 25-61-02.SDR UALA2011032201371Line · looseDOOR 1R WILL NOT ARM. FOUND STATIC LINE LOOSE AND INTERFERING WITH GIRT BAR FLOOR FITTING. ACCOMPLISHED SERVICE TIP AMM, CHECKS OKAY.SDR UALA2011032101349Slide · low pressureNR 5 RT MED SLIDE RESERVOIR BOTTLE PRESS LOW. REPLACED SLIDE IAW AMM.SDR SWAA112008Slide · looseDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MT.SDR SWAA112007Lens · looseDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE LIGHT LENS LOOSE. SECURED LENS PER MT.SDR DALA1120993310Slide · faultedDURING EMERGENCY LIGHT TEST, SLIDE DOOR 1 LEFT SHOWED LOAD FAULT. REPLACED SLIDE 1L AND CHECKED OK.SDR UALA2011032101366Switch · brokenSPRING BROKEN ON GUARD FOR SLIDE PRESSURE TEST BUTTON AT 2L. REPLACED SWITCH ASSY AT DOOR 2 LEFT. SYSTEM CHECKS NORMAL WHILE AT THE GATE.SDR UALA2011032101318Slide · delaminatedRT OFFWING SLIDE FOUND DELAMINATED BEYOND LIMITS AFT EDGE APPROX 14"X .75" AFTER SANDING INSPECTION. REPLACED RT OVERWING SLIDE ASSY PER MM.SDR UALA2011032101319Pin · obstructedLT OVERWING SLIDE DOOR 2 FORWARD BALL LOCK PINS HAVE BEEN PREVIOUSLY PAINTED. REPLACED LT OVERWING SLIDE ASSY PER MM.SDR SWAA111975Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY FELL OUT. RE-INSTALLED SLIDE PER MT.SDR ZZDA2011313Slide · unserviceableINFLATION CABLE PINS FOUND LAYING ON THE FLOOR FOR R1 DOOR. REMOVED AND REPLACED FORWARD SERVICE DOOR ESCAPE SLIDE IAW B717 25-61-03, OK FOR SERVICE.SDR UALA2011031801302Power Supply · inoperativeEMERGENCY ESCAPE SLIDE SQUIB TEST NR 1 RT FAILS ON TEST. RT OFF WING ESCAPE POWER SUPPLY BATTERY VOLTAGE LOW. REPLACED POWER SUPPLY AND BATTERY ASSY SQUIB TEST OK. ACP INSPECTION OF BATTERY PACK AND POWER SUPPLY INSTALLATION.SDR UALA2011031701298Lanyard · unsecureCREW REPORT: DOOR 2L SLIDE STRINGS HANGING OUT OF COVER. RE-SECURED LANYARD STRING.SDR SWAA111970Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR LOW. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2011031701295Slide · unwanted deployRT OVERWING SLIDE DEPLOYED BUT NOT INFLATED AND RT OVRD SPOILER ACTUATOR FIRED 2ND TIME. SECURED SLIDE AND REPLACED SQUIBS PER MM. ACP RII OF RT OVERWING SLIDE SQUIBS INSTALLED PER MM. REPLACED ACTUATOR. RETURNED ESCAPE SLIDE SYSTEM TO NORMAL PER MM. ALL PSDR UALA2011031701290Slide · unsecureLT OVERWING SLIDE HAS LOOSE LACES. REPLACED LT OVERWING SLIDE IAM AMM. ACCOMPLISHED INSPECTION OF SLIDE INSTALLATION MM.SDR UALA2011031601254Proximity Switch · weak2L SLIDE LIGHT NOT ON. APPLIED MEL2566S. REF TO WD 25-66-11, FOUND GIRT BAR PROX S108218 WEAK. REPLACED PROX SWITCH. OPS CHECKED OKAY.SDR SWAA111949Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA111947Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REPOSITIONED SLIDE PER MM.SDR SWAA111935Slide · unwanted deployL1 DOOR EMERGENCY EVAC SLIDE INADVERTANTLY DEPLOYED. REMOVED AND REPLACED SLIDE PER MM.SDR NOCA01811Switch · obstructedL1 DOOR SLIDE ARM LIGHT STAYS ON WITH DOOR DISARMED. REMOVED DEBRIS FROM L1 DOOR SLIDE ARM SWITCHES, OPS CHECK GOOD PER MM 25-66-00.SDR SWAA111938Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR NOCA02611Slide · low pressureR4 DOOR SLIDE PRESSURE AT EXTREME LOW END OF NORMAL OPERATIONAL RANGE. REMOVED AND REPLACED R4 DOOR SLIDE AS PER NAA JOB CARD 767-25-029-01.SDR ZZDA2011308Lanyard · frayedL1 DOOR EMERGENCY SLIDE LANYARD FRAYED. REMOVED AND REPLACED L1 DOOR EMERGENCY SLIDE LANYARD REF AMM 25-61.SDR UALA2011031401227Sensor · faultedTHE SLIDE ARMED LIGHT AT DOOR 1R IS NOT ON WHEN DOOR IS ARMED. CLEANED LED CONTACTS IN LENS CAP. SLIDE ARM LT CK'S NORMAL. LIGHT NOW WORKING NORMAL AFTER SLIDE ARMED, INTERMITTANT OPERATION. REPLACED LIGHT ASSY WITH BASE. CONFIRMED LIGHT WIRED CORRECTLY, NO HSDR UALA2011031401226Seal · damagedDOOR 4L DOOR SLIDE REMOVED FOR SEAL REPAIR. SAME DOOR SLIDE RE-INSTALLED REF AMM.SDR SWAA111845Slide · out of positionDURING SCHEDULED OTS CHECK, FOUND L2 DOOR EMERGENCY SLIDE GAUGE NOT VISIBLE. ADJUSTED SLIDE PER MT.SDR SWAA111808Slide · out of positionL1 DOOR EMERGENCY SLIDE PARTIALLY OUT OF CONTAINER. RE-INSTALLED L1 SLIDE INTO CONTAINER PER MT.SDR FDEA201103130949Slide · unwanted deployL1 SLIDE DEPLOYED ON ARRIVAL. R&R L1 DOOR MOUNTED ESCAPE SLIDE PACK IAW AMM 25-66-01-4 AND R&R L1 EPAS RESERVOIR IAW AMM 52-11-22-4, ACFT OK FOR SERVICE.SDR SWAA111893Slide · low pressureAFT ENTRY SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2011031401205Battery Pack · no testRT EMERGENCY SLIDE LIGHT DOES NOT TEST. REPLACED BATTERY PACK FOR OVERWING. OPS OKAY.SDR SWAA111671Slide · out of positionDURING SCHEDULED OTS CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.
Back to JASC 2565