SDR UALA2010081803024Slide · faultyEMERGENCY EXIT LIGHT CHECK FAILED. EXTERNAL LOADS AFT L DISPLAYED. CYCLED CB'S, NO HELP. HAD 'EXTERIOR LOADS FAULT' ON 13WL AFT LEFT EPCU. REPLACED DOOR 2L SLIDE ASSY. INSPECTED DOOR SLIDE 2L INSTALLATION FOR SECURITY, ELEC CONNECTION AND CABLE ROUTING GOOD,SDR IPXA0161966Warning Light · false activationWHILE PASSING THROUGH FL210 ON CLIMB OUT GOT SLIDE WARNING ON CREW DOOR (AURAL AND LIGHT) WARNING WENT OUT ON DESCENT PASSING THROUGH 13,500 AT 305 KTS AND 410 PSI. PERFORMED OPS TEST OF EMER ESCAPE SLIDE RELEASE IAW MM 52-73-00-05. AURAL AND LIGHT CHECKS GOOSDR SWAA104891Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA104883Slide · out of positionDURING SCHEDULED MV1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA104875Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR UALA2010081703016Bottle · faultyLT OFF WING SLIDE INFLATION RESERVIOR, SLEEVE NUT LOCK WIRE HOLE BROKEN (OPEN). R & R LT OVERWING SLIDE BOTTLE. OPS & LEAK CKS GOOD IAW AMM.SDR UALA2010081703003Slide · deployedDOOR 4R - DOOR SLIDE DEPLOYED. REPLACED DEPLOYED SLIDE WITH SERVICEABLE SLIDE ASSY.SDR IPXA0161967Battery Pack · dischargedMAIN DOOR SLIDE VOLTAGE INOP, DEFERRED M432151. TESTED BATTERY VOLTAGE IAW MC256120-02-1-L. MINIMUM VOLTAGE REQUIRED IS 8.7 VDC, WITHIN LIMITS. THIS CLEARS M432151.SDR SWAA104873Cover · missingDURING SCHEDULED CV CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE COVER MISSING. INSTALLED COVER PER MM.SDR SWAA104815Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MM AND MT.SDR SWAA104789Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2010081302955Cable · frayedL-2 DOOR SLIDE-RAFT COVER RELEASE CABLE IS FRAYED. REPLACED PER JIC 4R2592037 ON N-R C7015K.SDR SWAA104740Cable · frayedDURING SCHEDULED 22Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA104755Bracket · crackedDURING SCHEDULED 2HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD MOUNT BRACKET CRACKED. REMOVED AND REPLACED BRACKET PER MM.SDR ZZDA2010355Slide · unserviceableR1 DOOR SLIDE PRESSURE GAUGE IS IN RED. REMOVED AND REPLACED R1 DOOR SLIDE IAW AMM 25-61. OK FOR SERVICE.SDR WRLA20100810431Slide Raft · deployedL 1 DOOR SLIDE WAS FOUND TO BE PARTIALLY DEPLOYED WHILE STILL ATTACHED TO THE DOOR. THE GIRT BAR WAS NOT ENGAGED. THE DOOR ASSIST BOTTLE WAS FULL. THE SLIDE/RAFT BOTTLE WAS FULLY DISCHARGED. THE SLIDE SHROUD WAS DAMAGED. NO EVIDENCE OF DAMAGE TO THE DOOR SDR SWAA104753Slide · out of adjustDURING SCHEDULED 2HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA104749Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER, DID NOT DEPLOY. RE-PACKED SLIDE PER MM.SDR SWAA104718Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA104756Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA104719Slide · looseR2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MT.SDR R61A20100396Slide · inoperativeMX REPORTED L-2 EMERGENCY EVACUATION SLIDE INOP, AND FOUND THE BUSTLE RETAINING PIN BEING AT FAULT. MX R & R L-2 EMERGENCY EVACUATION SLIDE IAW AMM.SDR SWAA104715Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA104676Bracket · crackedDURING SCHEDULED 16Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD MOUNTING BRACKET CRACKED. REPAIRED BRACKET PER ER.SDR SWAA104662Slide · out of adjustDURING SCHEDULED 12Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR ZZDA2010351Slide · unserviceableL1 SLIDE PACK PRESSURE INDICATES OUT OF GREEN BAND. L1 DOOR SLIDE REMOVED AND REPLACED IAW 25-61. OPS CHECK GOOD.SDR ZZDA2010349Cover · detachedR1 DOOR SLIDE HOLDER DETACHED FROM DOOR. REPLACED R1 DOOR SLIDE COVER REF MM 25-61.SDR UALA2010080902897Slide · unserviceableDOOR 2L STRAP HANGING FROM SLIDE PACK. WHITE STRAP THAT GOES TO FRONT OF GRIT BAR HAS WORN HOOK AND LOOP. UNABLE TO ATTACH STRAP TO GRIT BAR. DOOR 2 LT MED SLIDE WAS REMOVED FOR SLIDE CHANGE, BUT WAS PUT BACK ON DUE TO NEW SLIDE WAS BAD FROM STOCK. REINSTALSDR GTIA1000035Slide · no testDURING MX, LT WING SLIDE PARTIALLY DEPLOYED. REPLACED LT OVERWING SLIDE ASSY.SDR USAA2010080991623Cable · brokenFLT 10 - ORD-PHX - EMERGENCY EQUIPMENT - LEFT OVERWING SLIDE RESERVOIR CABLE BROKEN. REMOVED AND REPLACED LEFT OVERWING SLIDE RESERVOIR ASSEMBLY IAW 25-62-46.SDR UALA2010080902874Slide · unserviceableTHE 1L ENTRY SLIDE RAFT LACING CABLES FOUND PULLED FROM SLIDE PACK, LEFT SIDE. REPLACED SLIDE ON DOCK WU L0302H.SDR SWAA104636Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA104634Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. REMOVED AND REPLACED SLIDE PER MT.SDR R61A20100390Slide · unserviceableGENERATED WHILE A/C WAS IN HEAVY CHECK, MAINTENANCE REMOVED AND REPLACED R-2 EMERGENCY EVACUATION SLIDE PER EMB AMM, DUE TO LOOSE LACING.SDR SWAA104583Slide · looseDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR SWAA104577Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA104584Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA104580Lens · crackedDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE COVER LENS CRACKED. REMOVED AND REPLACED LENS PER MT.SDR UALA2010080402823Slide · faultyDURING TEST OF EMERGENCY LIGHT SYS GOT MESSAGES 'INT. LOADS FWD L', 'EXT LOADS FWD L', 'EXT LOADS AFT L'. FOR THE INT. LOADS FWD L FOUND EMERGENCY LIGHT AT SEAT 6ABC SHORTED. REPLACED LIGHT, LIGHT OP CHECKS OK. THE EXT LOADS AFT L, SUSPECT AFT LEFT SLIDE. RESDR SWAA104536Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA104535Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR AALA20100802MEX01Slide · out of positionAFTER LANDING WHEN FORWARD CABIN DOOR WAS OPEN EVACUATION SLIDE FELL OUT OF PACK BUT WAS NOT DEPLOYED. VERIFIED SLIDE WAS OK AND RE-INSTALLED.SDR SWAA104520Slide · looseL1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR SWAA104478Slide · unwanted deployR2 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA104473Slide · looseR1 DOOR EMERGENCY EVAC SLIDE LOOSE. SECURED SLIDE PER MM.SDR SWAA104501Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA104477Slide · low pressureDURING SCHEDULED MV2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR LOW. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA104345Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA104344Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA104334Slide · out of positionDURING SCHEDULED SPV CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.
Back to JASC 2565