Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20100113TUL15Indicator · inoperativeEMERGENCY SLIDE LIGHT INDICATOR BURNED OUT AT LEFT NUMBER FOUR DOOR. REPLACED LAMP.SDR IPXA09M57980Slide · inoperativeINSPECTION TYPE:N/A L1 DOOR SLIDE INOP / REMOVED. DEFERRED M414287. INSTALLED L1 DOOR SLIDE ASSY CONTAINER ASSY IAW AMM 25-61-01-4. PLACARD REMOVED. THIS CLEARS 414287.SDR SWAA097576Slide · looseDURING SCHEDULED 8Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE LOOSE. REMOVED AND REPLACED SLIDE PER MT.SDR AALA20091218AFW01Slide · failedSLIDE DID NOT INFLATE. REPLACED SLIDE.SDR SWAA097653Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097652Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097588Attach Bracket · looseDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE ATTACH BRACKETS LOOSE. SECURED BRACKET PER MM.SDR SWAA097557Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097551Mount Bracket · crackedDURING SCHEDULED 8Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE LOWER MOUNT BRACKET LOOSE. REMOVED AND REPLACED BRACKET PER MM.SDR AALA20091130LHR01Relay · inoperativeLEFT SLIDE DOES NOT TEST ON SYSTEM 1. REPLACED RELAY.SDR SWAA097567Slide · out of positionDURING SCHEDULED 2HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA097566Slide · out of positionDURING SCHEDULED 2HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA097555Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER SRM.SDR SWAA097546Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. REMOVED AND REPLACED SLIDE PER MT.SDR UALA2009113003690Latch · faultyLT OVERWING COMPARTMENT DOOR INTEGRATOR TORQUE CHECK EXCEEDS 175 INCH POUNDS. INSTALLED 2 EA NEW DOOR LATCHES FOR THE LT OVERWING SLIDE COMPT DOOR AND OPS CHECKS GOOD.SDR SWAA097510Slide · out of limitsDURING SCHEDULED MV1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MT.SDR SWAA097516Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-ADJUSTED SLIDE PER MM.SDR SWAA097515Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR R61A20090087Slide · out of positionMTX REPORTED THE L-2 DOOR SLIDE FELL OUT OF IT'S HOLDER. MTX RE-SECURED THE SLIDE BUSTLE COVER IAW EMB 190 AMM 25-23-05, NO FURTHER DEFECTS NOTED.SDR SWAA097543Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR SWAA097536Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MT.SDR USAA2009120193272Slide · defectiveNON-ROUTINE: 26C83152002 / 002 / 5001959 - BC6 / BRIDGE CHECK - PIT - EMERGENCY EQUIPMENT - L1 DOOR SLIDE RELEASE CABLE DISCONNECT TO PAWL SAFETY WIRE FOUND TO BE BROKEN AT RELEASE ASSEMBLY UPON RE-INSTALLATION. REMOVED AND REPLACED SLIDE PACK ASSEMBLY.SDR IPXA09M57955Handle · damagedINSPECTION TYPE:N/A L1 SLIDE FWD STRAP HANDLE TORN/FRAYED. REPLACED CONTAINER ASSY FOR EVAC SLIDE FOR THE L1 DOOR PER MM 25-61-01-4.SDR CALA2009113000691Slide · misinstalledR2 DOOR SLIDE NOT INSTALLED PER M/M FOUND SLIDE COVER LATCH STRAP AROUND GIRT THIS PREVENTED GIRT BAR FROM BEING INSTALLED IN FLOOR MOUNTS. RE-INSTALLED R2 DOOR SLIDE PER M/M 25-61-35-402-003.SDR CALA2009113000690Slide · misinstalledL2 DOOR SLIDE NOT INSTALLED PER M/M. FOUND SLIDE COVER LATCH STRAP AROUND GIRT, THIS PREVENTED GIRT BAR TO BE INSTALLED INTO FLOOR MOUNTS. RE-INSTALLED L2 DOOR SLIDE PER M/M 25-61-35-402-003.SDR SWAA097478Cover · looseR2 DOOR EMERGENCY EVAC SLIDE COVER LOOSE. SECURED COVER PER MM.SDR SWAA097452Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE LOW. REMOVED AND REPLACED SLIDE PER MT.SDR IPXA09157954Slide · inoperativeCREW ENTRY DOOR SLIDE INOP. SLIDE PRESSURE INDICATOR IN RED ZONE. DEFERRED 413258. REMOVED AND REPLACED CREW ESCAPE SLIDE W/REF TO MM 25-61-2-04. THIS CLEARS M413258. PLACARD REMOVED.SDR UALA2009111803595Circuit Card · faultedRT WING SLIDE EICAS, RTFL. FOUND S219 PROX SENSOR WIRING CHAFED AT AFT SIDE OF SLIDE COMPARTMENT, REPLACED SENSOR AND ASSOCIATED WIRING. FOUND HARD FAULT ON PSEU FOR PROX, LOGIC AND DRIVER CARDS FOR S219 SENSOR. REPLACED PROX, LOGIC AND DRIVER CARDS FOR S21SDR UALA2009111903606Slide · low pressureTHE 1R SLIDE NOT IN GREEN PRESSURE. REPLACED SLIDE, OPS CHECK OK.SDR SWAA097340Slide · out of adjustR1 DOOR EVAC SLIDE GIRT BAR DIFFICULT TO SECURE. ADJUSTED SLIDE ASSY PER MM.SDR R61A20090082Pin · out of positionCREW REPORTS A PIN WAS HANGING DOWN FROM THE L-1 EVAC SLIDE. MAINTENANCE REMOVED AND REPLACED THE PIN PER EMB AMM 25-65-02-01.SDR SWAA097351Slide · out of adjustDURING SCHEDULED 2HC2 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097287Slide · looseDURING SCHEDULED MV1 CHECK, FOUND R1 DOOR EVAC SLIDE LOOSE. REPOSITIONED SLIDE PER MM.SDR SWAA097267Slide · out of positionR2 DOOR EVAC SLIDE OUT OF POSITION. RE-INSTALLED SLIDE PER MM.SDR SWAA097266Slide · out of positionR2 DOOR EVAC SLIDE PULL HANDLE OUT OF POSITION. REINSTALLED SLIDE PER MM.SDR UALA2009111803594Lanyard · out of positionDOOR 1R LANYARD NOT VISIBLE ON SLIDE PACK. MAYBE MISSING OR DAMAGED BEYOND SVC LIMITS, A-C CANNOT OPERATE ON EXTENDED OVERWATER. FOUND LANYARD TWISTED AND OUT OF POSITION, REPOSITIONED AND SECURED MOORING LINE AND SURVIVAL KIT LANYARD.SDR UALA2009111803593Lanyard · out of positionLANYARD MISSING FROM SLIDE PACK DOOR 2R: MAYBE MISSING OR DAMAGED BEYOND SVC LIMITS, A-C CANNOT OPERATED ON EXTENDED OVERWATER. FOUND LANYARD TWISTED AND OUT OF POSITION, REPOSITIONED AND ROUTED MOORING LINE AND SURVIVAL KIT LANYARD.SDR SWAA097190Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UALA2009111603549Slide · unsecureWHEN OPENING DOOR 1L FOUND SLIDE HAD FALLEN OFF AND WAS RESTING ON FLOOR. RESECURED SLIDE PACK DOOR 1L.SDR UALA2009111603558Slide · faultyEMERGENCY LIGHT TEST FAIL TEST, MSG EXT LOAD FWD LEFT, BATTERY FWD LEFT, BATTERY AFT LEFT. REPLACED LEFT FWD EPSU BATTERY PACK AND LEFT AFT EPSU BATTERY PACK AND CLEARED THE BATTERY MSG'S. FOUND SLIDE AT DOOR 1R BAD FOR "EXT LOAD FWD LEFT" FAULT. NEEDS A SLSDR SWAA097227Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097174Slide · out of positionL1 DOOR FELL OUT OF CONTAINER. DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR ZZDA2009373Slide · unserviceableL-1 GIRT BAR HANGS DOWN LOOSELY. NO DEFECTS NOTED ON GIRT BAR. REMOVED AND REPLACED L-1 EVACUATION SLIDE PER 25-61 DUE TO PINS DISCONNECTED.SDR UALA2009111303539Wire Harness · frayedMAIN CABIN R1 DOOR SLIDE HARNESS LOWER CENTER ATTACH POINT FRAYED. REPLACED R1 DOOR SLIDE HARNESS.SDR SWAA097320Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR SWAA097319Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR SWAA097316Slide · out of adjustDURING SCHEDULED 2HC2 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA097177Slide · out of positionR1 DOOR EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA097298Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. REPOSITIONED SLIDE PER MM.
Back to JASC 2565