Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA0800009Slide · unwanted deployPASSENGER DOOR R2 SLIDE PACK CAME APART DURING REMOVAL. REPLACED R2 DOOR SLIDE PACK.SDR USAA920080425Slide · defectiveMIA - EES - C4 CHCEK - FORWARD SERVICE DOOR SLIDE DEPLOYMENT STRAP IS RELEASED. REPLACED FORWARD SERVICE DOOR SLIDE ASSEMBLY IAW USAIRWAYS JOB CARD J8-90-90202.SDR 2008UALA00774Cylinder · defectiveLEFT OVERWING SLIDE CABLE BALL IS BELOW RETAINER SPRING ON INFLATION CYLINDER.SDR 2008UALA00715O-Ring · leakingSLIDE ASPIRATOR LEAKING. ASPIRATOR HAD BAD O-RING. REPLACED ASPIRATOR. SUSPECT O-RING PINCHED OR OVERLY COMPRESSED DURING INSTALLATION. SLIDE REPLACED AND A/C OK FOR SERVICE.SDR 2008UALA00714Aspirator · leakingSLIDE ASPIRATOR BARREL LEAKING. NO APPARENT DAMAGE TO ASPIRATOR. SUSPECT SEAL LEAKAGE. REPLACED ASPIRATOR & SLIDE ASSY. A/C OK FOR SERVICE.SDR SWAA080739Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR BB08011Slide · disconnectedMIA - A LOWER DEPLOYMENT STRAP WAS FOUND RELEASED ON THE FORWARD SERVICE DOOR SLIDE ASSEMBLY. MAINTENANCE REPLACED THE FORWARD SERVICE DOOR ESCAPE SLIDE. OK FOR SERVICE.SDR BB08012Slide · failedCLT - EMERGENCY DOOR SLIDE ON EXIT DOOR 4L HAS LOW BOTTLE PRESSURE. MAINTENANCE REMOVED AND REPLACED SLIDE ASSY.SDR SWAA080731Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080720Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080719Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AMTA200800061Battery · dischargedR2 DOOR ESCAPE SLIDE LIGHT DOES NOT TEST. REPLACED BATTERYS IN LOW PRESSURE INDICATOR SYSTEM, OPS CKS NORMAL. (K)SDR SWAA080709Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080705Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR DL757080351Slide · no testRIGHT OFF WING SLIDE FAILED OPS TEST FOR MANUAL DEPLOYMENT OF CARRIER. READJUSTED CARRIER HOOK LOCK AND PERFORMED OPS TEST FOR MANUAL DEPLOYMENT OF CARRIER IAW MM 25-65-08.SDR DL757080345Slide · no testLEFT OFF WING SLIDE FAILED AMNUAL BACK-UP SYSTEM TEST. REPLACED BOTTLE BACK-UP CABLE IAW MM 25-65-06.SDR AMTA200800060Battery Pack · dischargedL2 DOOR ESCAPE SLIDE LIGHT NOT TESTING. REPLACED LOW PRESSURE INDICATOR, BATTERY PACK, JACK ASSY, INDICATOR OPS CKS, NORMAL IAW AMM 25-61-03. (K)SDR DL76G080157Slide · disconnectedWHILE WORKING OPN 58118 FINAL ESCAPE SYSTEM CHECK FOUND FOUND SLIDE WAS PARTIALLY DE-LACED AND BOTH FWD AND AFT DEPLOYMENT CABLES AND AND DEPLOYMENT CABLE RETRACTORS WERE NOT INSTALLED ON THE A/C. PARTS WERE ORDERED AND DISCREPANCY CORRECTED.SDR 2008UALA00673Cover · out of positionTHE 4R SLIDE PACK COVER FELL OFF. MAINT TEXT: SLIDE PACK CAME LOOSE FROM TOP ATTACH POINT. SUSPECT SLIDE IMPROPERLY INSTALLED. REINSTALLED SLIDE. AC OK FOR SERVICE.SDR 2008UALA00659Aspirator · unserviceableASPIRATOR LEAKING.SDR SWAA080684Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR YENA2008016Control Cable · stiffON C1 CHECK, LT EMERGENCY EXIT FAILS OPS TEST FLEX CABLE STIFF AND WILL NOT RETRACT. REMOVED AND REPLACED LT FLEXIBLE CABLE ASSY PER AMM 25-62-43-04.SDR 2008UALA00644Mechanism · out of adjustDOOR 1L DOES NOT SHOW "SLIDE" ON ECAM OR "SLIDE ARMED" ON DOOR WHEN DOOR ARMING HANDLE IS PLACED IN THE ARM POSITION. FOUND DOOR ARMING MECHANISM OUT OF ADJUSTMENT. ADJUSTED DOOR, ARM LIGHTS OPERATE NORMALLY.SDR ASAA0842540Slide · contaminatedRIGHT FORWARD (R 2) SERVICE DOOR EMERGENCY SLIDE FAILED TO DEPLOY DURING DURING TEST. DETERMINE THAT SLIDE WAS TIED WITH A CHORD WHICH PREVENTED IT FROM DEPLOYING. REMOVED SLIDE AND SHIPPED WITH A VIDEO OF THE FAILED DEPLOYMENT TEST. DETERMINED NO SYSTEM FASDR SWAA080656Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR UPS08851613Gauge · unserviceableESCAPE SLIDE PRESSURE GAUGE NOT VISIBLE. REPOSITIONED SLIDE IN CASE FOR PRESSURE GAUGE TO READABLE FROM WINDOW.SDR SWAA080602Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080589Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00609Lanyard · misriggedDOOR 4R, DOOR SLIDE WILL NOT FULLY DISARM. FOUND DOOR SLIDE LANYARD WRAPPED IN MECHANISM FOR SLIDE GIRT BAR. STOWED LANYARD PROPERLY, DOOR SLIDE ARM/DISARM NOW WORKS FREELY. NO REPEATS.SDR 2008UALA00592Aspirator · damagedFLAPPER VALVES ON ASPIRATOR LEAKING. FOUND SLIDE WAS DEPLOYED AND COULD BE THE CAUSE OF DAMAGED ASPIRATOR. REPLACED ASPIRATOR, OPS CHECKED NORMAL.SDR YENA2008015Control Cable · stiffON C2-01 CHECK, LEFT OVERWING SLIDE FLEXIBLE CONTROL CABLE STIFF AND FAILS TO RETRACT FOR OPS TEST. REMOVED AND REPLACED LT FLEXIBLE CONTROL CABLE ASSY PER AMM 25-62-43-04, OPS CHECK OK.SDR YENA2008014Control Cable · stiffON C2-01 CHECK, RIGHT HAND OVERWING SLIDE FLEXIBLE CONTROL CABLE STIFF AND FAILS TO RETRACT FOR OPS TEST. REMOVED AND REPLACED RT FLEXIBLE CONTROL CABLE ASSY PER AMM 25-62-43-04, OPS CHECK OK.SDR SWAA080601Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080611Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00590Valve · leakingASPIRATOR LEAKING. FAULTY VALVE. REPLACED SLIDE AND ASPIRATOR. ACFT OK FOR SERVICE.SDR SWAA080567Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080563Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080562Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00514Bottle · low pressureLEFT UPPER DECK DOOR SLIDE, AFT BOTTLE NEEDLE IS OUT OF THE GREEN BAND. SUSPECT FAULTY O-RING. REPLACED AFT BOTTLE PER AMM 25-68-02. AC OK FOR SERVICE.SDR SWAA080566Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080540Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA080530Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00555Disk · leakingLOW BOTTLE. BURST DISK LEAKING. REPLACED BURST DISK.SDR 08FDEA00324Chain · failedDURING ESCAPE SLIDE/RAFT OPS CHECK, MED L1 FAILED TO DEPLOY IN EMERGENCY MODE. L1 DOOR AFT DRUM POWER DRIVE ROLLER CHAIN REMOVED AND REPLACED AS PER CMM 52-11-09. EMERGENCY OPERATIONAL TEST CARRIED OUT AS PER AMM 52-11-04-5.SDR UPS08M51584Cover · unsecureL1 ENTRY DOOR ESCAPE SLIDE COVER WILL NOT STAY SECURED TO MAG HOLDERS HANGS OPEN WHEN DOOR IS NOT CLOSED. SECURED L1 SLIDE COVER REF 25-61-15.SDR 2008UALA00510Slide · shortedEMERGENCY LIGHT SYSTEM TEST FAILS WITH CFDS MESSAGE EXT LOAD FWD LEFT. ELECTRICAL SHORT WITHIN FWD LEFT SLIDE ASSY. REPLACED SLIDE AT FWD LT DOOR. ALL CHECKS ARE NOW NORMAL.SDR 2008UALA00490Gauge · out of positionFORWARD GALLEY DOOR ESCAPE SLIDE BOTTLE GAUGE NOT CENTERED IN VIEW WINDOW. CENTERED PRESSURE GAUGE IN INSPECTION WINDOW. AC OK FOR SERVICE.SDR UPS08151586Slide · dislodgedDOOR WAS OPEN BEFORE SLIDE DISARMED, SLIDE DID NOT DEPLOY BUT FELL OUT ON STAIRS. DEFERRAL M367928. INSTALLED MAIN ENTRY DOOR ESCAPE SLIDE REF 25-61-21-04. PLACARD REMOVED.SDR SWAA080494Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2008UALA00479Slide · dislodgedWHILE OPENING 1L DOOR SLIDE RAFT FELL OUT. REPLACED SLIDE.
Back to JASC 2565