Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS07M50643Indicator · faultyINSPECTION TYPE:N/A R1 EVACUATION SLIDE REMOTE PRESSURE PRESS TO TEST INDICATING SYSTEM INOP. RELAMPED, NO HELP. ITEM DEFERRED IAW MD11 MEL 25-01-2. DMI M358567. T/S PERFORMED FOUND EVAC SLIDE PRESSURE VESSEL INDICATOR AT FAULT. REMOVED AND REPLACED EVAC SDR AALA20071724Slide · malfunctionedDFW INFLIGHT T1034/11SEP - DURING CLIMB RECEIVED LEFT NUMBER ONE DOOR EICAS MESSAGE. DURING DESCENT RETURNING TO DFW CREW IN CABIN REPORTED THUMPING SOUND COMING FROM FLOOR LEVEL. LANDED DFW WITHOUT INCIDENT. FOUND LEFT OVERWING SLIDE IN FLIGHT DEPLOYMENT WSDR SWAA074540Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR AALA20071715Slide · failedORD - LEFT NUMBER ONE DOOR WAS OPENED WITH DOOR SLIDE ARMED. SLIDE FELL ON TO JETBRIDGE AND PINS PULLED OUT. DID NOT DEPLOY. REPLACED LEFT NUMBER ONE DOOR SLIDE.SDR SWAA074551Slide · out of adjustDURING SCHEDULED RON CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SA07058Slide · faultyCLT - RECEIVED A RIGHT EMERGENCY EXIT SLIDE ECAM MESSAGE DOOR 2R. MAINTENANCE ACCOMPLISHED A CHECK OF THE DOOR SLIDE ARMING/DISARMING SYSTEM, AND CHECKED WIRING AND LINKAGE. NO FAULTS FOUND. REPLACED THE RIGHT SIDE, POSITION 2, EMERGENCY DOOR ESCAPE SLIDE ASDR ZZDA2007269Slide · unwanted deployR-1 DOOR SLIDE ACCIDENTALLY DEPLOYED WHEN DOOR WAS OPENED. GIRT BAR WAS NOT IN FLOOR RECEPTACLE, IT HAD BEEN DISARMED. SLIDE FULLY DETACHED FROM A/C. REMOVED & REPLACED R-1 DOOR SLIDE, OPS CHECK GOOD IAW AMM 25-66-01. A/C OK FOR SERVICE.SDR SWAA074496Slide · out of adjustDURING SCHEDULED 10Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200700227Slide · faultedDURING C4/S1 CHECK, INSPECTION REPORTED EMERGENCY LIGHT TEST SHOWED LEFT EPSU EXTERNAL FAULT. REPLACED R1 DOOR SLIDE IAW AMM 25-62-44-400-007.SDR 2007UALA03641Girt Bar · contaminatedLIGHT FOR SLIDE AT DOOR 1R INOPERATIVE. 10-11-07 FOUND DEBRIS IN GIRT SLIDER AREA ON FLOOR CLEANED DEBRIS, LUBED SLIDE TRACKS AND CYCLED DOOR SEVERAL TIMES AND FOUND NORMAL OPERATIONS OF SLIDE LIGHT AND NORMAL ENGAGEMENT OF GIRT BAR.SDR SWAA074489Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA074490Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA20071707Bottle · inoperativeLAS LEFT NUMBER ONE SLIDE WAS NOT DISARMED AND DOOR WAS OPEN FROM INSIDE. SLIDE DID NOT DEPLOY. FELL ON AIR STAIRS. DOOR ASSIST BOTTLE EXPENDED. REINSTALLED SLIDE WITH NEW DOOR ASSIST BOTTLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA03655Slide · low pressureSLIDE PRESSURE 3L IN THE RED BAND. REPLACED CYLINDER. PRESSURE NOW READS IN THE GREEN BAND.SDR SWAA074484Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074486Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074474Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074461Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074470Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA074479Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA03610Lamp · inoperativeTHE 3R SLIDE ARMED LIGHT INOP. FOUND A FUSED LAMP. REPLACED LAMP.SDR HALA0700371Slide & Sleeve · unwanted deploySLIDE RAFT AT L1 DOOR DEPLOYED. INSTALLED L1 DOOR SLIDE PER AMM 25-66-01. CLEARED MIC SHEET, REMOVED PLACARD.SDR SWAA074453Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR PER MM.SDR SWAA074432Bracket · crackedDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD BRACKET CRACKED. REMOVED AND REPLACED BRACKET PER MM.SDR UPS07850631Slide · looseINSPECTION TYPE:N/A ESCAPE SLIDE IS LOOSE. REINSTALLED ESCAPE SLIDE.SDR UPS07850621Slide · out of positionESCAPE SLIDE ON CAPTAIN'S SIDE FELL OUT. 10-8-07 REINSTALLED CAPTAIN'S ESCAPE TAPE (ROPE) AND LINING IAW DC8 MM 25-61-13-04.SDR SWAA074394Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074392Window · missingDURING SCHEDULED MV1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE VIEWING WINDOW MISSING. INSTALLED WINDOW PER MM.SDR SWAA074413Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA074393Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ZZDA2007268Lanyard · pulledL1 DOOR SLIDE LANYARD IS PULLED. BOTH PINS ARE PULLED ON SLIDE PACK. REMOVED AND REPLACED L1 DOOR SLIDE PACK IAW B717 M/M 25-61.SDR AMTA200700417Slide · unserviceableL2 DOOR SLIDE/ AIR BOTTLE LOW PRESSURE LIGHT WILL NOT TEST. REMOVED AND REPLACED L2 DOOR SLIDE REF MM 25-61-07. SLIDE BOTTLE LOW PRESS LIGHT NOW CHECKS NORMAL. (K)SDR SWAA074373Slide · out of adjustDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR DL757071172Trigger · brokenDURING OPN 6T129 SLIDE/RAFT SAMPLING PROGRAM 2L DOOR SLIDE DID NOT DEPLOY. FOUND 2L DOOR TRIGGER BROKEN REPLACED SAME PER M/M. INSTALLATION ADJ GOOD (QC1503) C/W OPN 6T129, NO DEFECTS FOUND.SDR 2007UALA03512Slide · failedDOOR 1L EMERGENCY SLIDE FAILS EMERGENCY LIGHT TEST. REPLACED DOOR 1L SLIDE PACK.SDR SWAA074334Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS07M50605Light · inoperativeINSPECTION TYPE:N/A R1 MAIN ENTRY DOOR SLIDE REMOTE PRESS IND TEST INOP. RELAMPED AND CHECKED NORMAL.SDR SWAA074354Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA074364Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA074315Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA03497Fitting · out of adjustDOOR 1R DOES NOT HAVE ARM LIGHT WHEN DOOR IS ARMED AND CREW STATES THAT DOOR DOES NOT FEEL NORMAL WHEN ARM SELECTED.SDR SWAA074293Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA074298Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA03489Disk · rupturedLOW BOTTLE PRESSURE. FOUND RUPTURE DISC LEAKING. REPLACED RUPTURE DISK.SDR 2007UALA03484Mechanism · out of positionLEFT OVERWING SLIDE INFLATION CYLINDER PULL FORCE MECHANISM BALL IS IN THE WRONG POSITION, BALL IS IN FRONT OF THE RETAINER SPRING, NOT BEHIND IT AS REQUIRED.SDR 2007UALA03483Latch · out of toleranceLEFT OVERWING SLIDE DOOR LATCHES NR 1, 2, 3 & 4 FAIL EDGE MARGIN TEST.SDR 2007UALA03481Bottle · faultyDOOR 5 RIGHT SLIDE CAME OFF. DOOR ASSIST BOTTLE NEEDS REPLACEMENT.SDR 2007UALA03480Slide · faultyDOOR 5 RIGHT SLIDE CAME APART. DID NOT DEPLOYED.SDR SWAA074279Hook · looseR1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. REMOVED AND REPLACED GIRT BAR HOOK PER MM.SDR 2007UALA03488Hose · failedASPIRATOR LEAKS. ON TROUBLESHOOTING FOUND DAMAGED INFLATION HOSE, WHICH SUPPOSEDLY HAPPENED DURING PACKING THEREBY INACTIVATING . REPLACED HOSE.
Back to JASC 2565