SDR SWAA073287Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073286Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02379Slide · misinstalledF/A REPORTS DOOR 2 RIGHT SLIDE DIFFICULT TO ARM & APPEARS TO BE VELCROED INCORRECTLY. [07-27-07] RE-POSITIONED VELCRO.SDR 2007UALA02374Cover · looseTHE 2R SLIDE COVER COMING OFF.SDR F3LA200700169Slide · looseDURING C-2 CHECK, INSPECTION REPORTED L1 DOOR SLIDE CAME UNPACKED. REPLACED L1 DOOR SLIDE IAW AMM 25-62-44-000-002. OPERATIONAL CHECK GOOD.SDR AWXA200700787Slide · failedLAS - EES - LOG# 4149154 - MX REPORTED THE L2 DOOR EMERGENCY SLIDE BOTTLE PRESSURE LOW. MX REPLACED THE L2 DOOR SLIDE IAW TASK CARD R1C25305.SDR 2007UALA02350Light · looseR EMERGENCY ESCAPE SLIDE SQUIB LIGHT FAILED TO ILLUMINATE. [08-08-07] SECURED LOOSE LAMP.SDR 2007UALA02332Slide · faultyEMERGENCY LIGHTS FAULTING EXTERNAL LOADS FWD LEFT.SDR AWXA200700789Slide · failedMCN - EES - BC-6 CHECK - LOG PAGE # 7739211 AND NR # 5980808, THE R1 DOOR SLIDE WAS DEPLOYED AND THE SLIDE FAILED TO INFLATE. REPLACED THE R1 DOOR SLIDE IAW AWA TASK CARD R1C25305.SDR SWAA073276Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073274Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02340Cover · missingDOOR 2L MANUAL INFLATION HANDLE EXPOSED (MISSING VELCRO COVER). [07-24-07] REPOSITIONED SLIDE PACK.SDR 2007UALA02328Flange · crackedLEFT OFFWING ESCAPE SLIDE HAS A CRACK IN VERTICAL AFT FLANGE LOWER END.SDR SWAA073269Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA073260Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02293O-Ring · damagedLOW BOTTLE PRESSURE. PIN HOLE LEAK AROUND O-RING ON PRESSURE GAUGE. REPLACED O-RING, RECHECKED, NO LEAKS FOUND, REPLACED WITH STOCK BOTTLE. SLIDE PROBLEM ROOT CAUSE: O-RING HARDENED DUE TO HEAT & OXIDATION & LOST ELASTICITY.SDR 2007UALA02295Flange · crackedRIGHT OFFWING ESCAPE SLIDE HAS A CRACK IN VERTICAL AFT FLANGE LOWER END, (AREA 2) 5 INCHES. REPLACED RT OVERWING SLIDE.SDR SWAA073245Cable · brokenDURING SCHEDULED 18Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE BROKEN. R&R EVAC SLIDE CABLE PER MM.SDR SWAA073257Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073256Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073227Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR BJNA070601Slide · failedDURING TRAINING DEPLOYMENT OF L-1 DOOR EMERGENCY EXIT SLIDE, THE SLIDE FAILED TO COMPLETELY UNFOLD, THE BOTTOM 2 LANYARDS FAILED TO PULL THROUGH STRAP EYELETS WHICH PREVENTED APPROXIMATELY THE LAST 1.5 - 2.0 FT TO UNFOLD AND INFLATE. AN ENGINEERING EVALUATIONSDR F3LA200700165Release Cable · out of adjustDURING C-2 CHECK, INSPECTION REPORTED OPERATIONAL TESTS OF BOTH OVERWING RELEASE SLIDE CABLES FAILED. ADJUSTED LT AND RT EMERGENCY SLIDE EXIT RELEASE CABLES IAW AMM 25-62-43-820-050 AND CHECKED GOOD.SDR UPS07250083Slide · inoperativeCREW SLIDE FELL OUT OF CONTAINER WHEN THE ENTRY DOOR WAS OPENED. REINSTALLED EVACUATION SLIDE IN THE CONTAINER IAW MM 52-25-60-14-2.SDR SWAA073217Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073202Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02259O-Ring · leakingSLIDE PRESSURE AT DOOR 5 LEFT LOW. THERE WAS A SMALL LEAK AROUND O-RING ON THE GAUGE ELBOW ASSEMBLY GOING INTO VALVE. REPLACED O-RING, WATER TESTED FOR 15 MINUTES, NO LEAK FOUND. REPLACED BOTTLE WITH STOCK BOTTLE. REPLACED SLIDE RAFT ASSEMBLY. SLIDE PROBLSDR SWAA073225Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA073224Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA073187Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMRGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073184Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR UPS07250056Slide · inoperativeESCAPE SLIDE IS OUT OF PACK. REINSTALLED EVACUATION SLIDE IAW AMM 25-60-14-2.SDR SWAA073163Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA073164Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02188Hook And Loop · wornDOOR 2L SLIDE-RAFT LANYARD HOOK AND LOOP STRIP DOES NOT STICK TOGETHER. FOUND WORN HOOK AND LOOP STRIP. REPLACED DOOR SLIDE 2L.SDR SWAA073148Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073116Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ASAA0741815Girt Bar · corrodedL2 DOOR SLIDE GIRT BAR CORRODED AND PITTED. REMOVED FROM SLEEVE PER TC 45125011. REMOVED AND REPLACED L2 DOOR SLIDE GIRT BAR PER CMM 25-66-07 PG 664 STEPS 14 (A, B, C AND D).SDR 2007UALA02176Proximity Switch · faultyDOOR 1R "SLIDE" LIGHT REMAINS DIMLY ILLUMINATED AT ALL TIMES. [08-08-07] REPLACED BOTH GIRT BAR PROXIMITY SWITCHES.SDR SWAA073083Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA073084Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02154Slide · unknownTHE 3L DOOR HARD TO ARM AND DISARM. [08-07-07] NO ABNORMAL FORCES NOTED. OPENED BOTH DOORS AND CHECKED FOR DEBRIS, NONE NOTED.SDR SWAA073068Slide · failedDURING SCHEDULED 8Y CHECK, R1 DOOR EMERGENCY EVAC SLIDE FAILED OPS CHECK. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA073056Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA02075Slide · faultyDURING 3SVC CHECK FOUND 4L SLIDE PRESSURE AT LOWEST SIDE OF GREEN BAND. [08-07-07] SLIDE REPLACED.SDR SWAA073044Girt Bar · crackedDURING SCHEDULED BRDG CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING LOOSE. SECURED FITTING PER MM.SDR SWAA073045Girt Bar · crackedDURING SCHEDULED BRDG CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED FITTING PER MM.SDR SWAA073046Girt Bar · crackedDURING SCHEDULED BRDG CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED FITTING PER MM.SDR SWAA073031Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR UPS07849983Slide · misinstalledMAIN EXIT ESCAPE SLIDE IS IMPROPERLY LOCATED INSIDE HOUSING. PRESSURE CANNOT BE READ. REMOVED AND REPLACED MAIN EXIT ESCAPE SLIDE CONTAINER IAW MM 25-60-01-2. PRESSURE INDICATOR VISIBLE THROUGH WINDOW.
Back to JASC 2565