Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA063774Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA063773Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA063769Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063767Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2006UALA01946Valve · unserviceableLOW PRESSURE ON CYLINDER. REPLACED SLIDE 2R. PERFORMED INSPECTION OF NR 2R DOOR SLIDE. CHECKS GOOD. THE BALL SEAT WAS LEAKING THERE WAS A CUT MARK ON THE BALL SEAT. REPLACED BALL SEAT.SDR MALA060571Slide · malfunctionedEVAC SLIDE BLOWING RIGHT SERVICE DOOR. REMOVED RIGHT SERVICE DOOR SLIDE AND PLACED IN CARGO AREA DEACTIVATED AND BLOWN INSPECTION A/C AND FOUND SAFE FOR ONE TIME FERRY FROM BTV TO DTW FOR REPLACEMENT OF SLIDE. L/P 1609251:A/C TO BE FERRIED FROM BTV TO DTW SLSDR 0602213244Slide · malfunctionedDURING EMERGENCY LIGHT TEST, EPSU EXT LOAD FWL ANNUNCIATED. REPLACED LEFT FORWARD EVACUATION SLIDE ASSEMBLY. CHECKS OK. SDR NOCA14206Slide · unknownFOUND L4 DOOR ESCAPE SLIDE BELOW LIMITS. REPLACED L4 SLIDE ASSY, OPS NORMAL.SDR SWAA063754Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063751Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063744Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063739Slide · dischargedDURING SCHEDULED MV1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA063738Cable · misroutedDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA063735Fitting · looseR2 DOOR EMEREGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED EVAC SLIDE FITTING PER MM.SDR SWAA063734Fitting · looseL1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING LOOSE. SECURED EVAC SLIDE FITTING PER MM.SDR SWAA063724Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063723Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA063722Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA063721Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR F3LA200600127Slide · faultyDURING C-3 CHECK, INSPECTION REPORTED L1 DOOR ARMED LIGHT DID NOT REMAIN ON IN -ARMED- POSITION. REPLACED ESCAPE SLIDE/RAFT.SDR KCSA061374Light · inoperativeFOUND UPPER DECK, RT EMERGENCY SLIDE LIGHT IS INOP.SDR SWAA063712Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FWD GIRT BAR FITTING PER SRM.SDR SWAA063711Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED AFT GIRT BAR FITTING PER SRM.SDR SWAA063710Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED AFT GIRT BAR FITTING PER SRM.SDR SWAA063709Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED FWD GIRT BAR FITTING PER SRM.SDR SWAA063703Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063702Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA063692Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063687Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA20060841Slide · inoperativeTUL - THE FORWARD GALLEY DOOR SLIDE DID NOT DEPLOY AUTOMATICALLY, IT DID DEPLOY MANUALLY. REPLACED SLIDE FOR FORWARD GALLEY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR BB06074Slide · failedDURING ACCOMPLISHMENT OF L1 DOOR ESCAPE SLIDE OPERATIONAL CHECK, SLIDE INFLATED NORMALLY BUT THE LIGHTS FAILED TO ILLUMINATE. MAINTENANCE REPLACED THE SLIDE ASSEMBLY.SDR SA06075Slide · tornIAD - A STRAP FROM THE L-1 DOOR ESCAPE SLIDE/RAFT TO THE SLIDE COVER WAS FOUND TORN OFF. MAINTENANCE REPLACED THE L-1 DOOR ESCAPE SLIDE/RAFT. OK FOR SERVICE.SDR UPS06M48048Slide · will not armRT ENTRY DOOR SLIDE WILL NOT ARM, RT SIDE GIRT BAR INSTALLED AND SECURE PER AMM 25-61-15.SDR UPS06148056Warning Buzzer · inoperativeWITH EMERGENCY ESCAPE SLIDE ARMED, BUZZER INOP WHEN TESTED. PLACED ON DEFERRAL M334426 PER MEL 52-73-01-2. PLACARD INSTALLED. R&R LIMIT SWITCH 9WN IAW 52-73-13-04 ADJ IAW 52-73-13. TEST OK. THIS CLEARS M334426SDR 2006UALA01868Squib · no testRIGHT SIDE NR 2 SQUIB WOULD NOT TEST. OFFWING EVACUATION SLIDE BOTTLE PRESSURE MEASURED AT 2500 PSI. BOTTLE WAS HYDROSTATICALLY TESTED - NO FAULTS FOUND. REPLACED CYLINDER.SDR UPS06M48049Girt Bar · looseL1 DOOR GIRT BAR LOOSE. INSTALLED AND SECURED L1 DR GIRT BAR PUSHROD IAW AMM 25-61-01-4.SDR 2006UALA01871Slide · no testLEFT OVERWING SLIDE WILL NOT TEST. BATTERY INOPERATIVE. REPLACED LEFT OVERWING SLIDE BATTERY.SDR SWAA063625Slide · out of adjustFOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01872Girt Bar · contaminatedFWD GIRT AT DOOR 4R HAS COME LOOSE, RAFT IS FALLING SLIGHTLY AND CAN`T GET GIRT TO ALIGN PROPERLY TO ENGAGE. FWD GIRT AT DOOR 4R HAS COME LOOSE, SLIDE RAFT FELL OUT OF POSITION SLIGHTLY. COULD NOT GET GIRT TO ALIGN PROPERLY TO ENGAGE. FOUND GIRT BAR NOT ENGSDR 0602093239Light · no testFORWARD LEFT SLIDE FAILS EPSU EMERGENCY LIGHT TEST. REPLACED FORWARD LEFT SLIDE PACK ASSEMBLY. CHECKS OK. SDR 2006UALA01874Valve · leakingLOW BOTTLE PRESSURE. BALL SEAT WAS LEAKING. REPLACED BALL SEAT.SDR 2006UALA01865Lanyard · dislodgedDOOR 3R SLIDE LANYARD FALLING OUT. MORE THAN ALLOWABLE SLACK TO LANYARD WITHIN ITS POUCH COULD HAVE INADVERTENTLY ALLOWED IT GET SNAGGED BY A GALLEY SERVICING EQUIPMENT. STOWED LANYARD TO SLIDE & GIRT BAR.SDR 2006UALA01835Bottle · underservicedCIDS CAUTION LIGHT ON DUE TO LEFT OVERWING SLIDE PRESSURE LOW (IN RED BAND). REPLACED LEFT OVERWING SLIDE BOTTLE.SDR SWAA063616Slide · out of adjustFOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063614Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063601Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063600Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA063599Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06848022Slide · inoperativeMAIN CABIN EXIT SLIDE/SLIDE INOP, LOW PRESSURE. REMOVED AND REPLACED SLIDE ASSY PER 25-60-01-2. CLEARED, PLACARD REMOVED AND BOTH COURIER SEATS REACTIVATED.SDR UPS06148012Warning Light · inoperativeEVACUATION SLIDE WARNING SYSTEM LIGHT FAILS TO ILLUMINATE WITH EITHER PUSH TO TEST OR ADJ/TEST PROCEDURE AMM 52-73-00-05. RELAMPED PER 52-73-11-04.
Back to JASC 2565