Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2006UALA01037Slide · out of positionDOOR 1L WAS PARTIALLY OPENED AND SLIDE PACK FELL OUT BUT DID NOT DEPLOY. SERVICED DOOR 1 LEFT ASSIST BOTTLE AND REPLACED DIAPHRAGM. REPLACED DOOR 1L SLIDE/RAFT ASSEMBLY.SDR SWAA061829Latch · brokenFOUND L2 DOOR EMERGENCY EVAC SLIDE LOWER RELEASE LATCH BROKEN. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR GTIA200600019Slide · out of positionL1 DOOR SLIDE PACK FELL OUT FROM BOTTOM OF DOOR. REPLACED L1 DOOR SLIDE.SDR SWAA061813Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED EVAC SLIDE PER MM.SDR SWAA061812Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061811Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061810Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061805Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA061798Slide · out of adjustDURING SCHEDULED 10Y CHECK, FOUND L2 DOOR EMERGECNY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA061796Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA061794Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. RE-INSTALLED SLIDE PER MM.SDR 2006UALA01022Gauge · leakingLOW BOTTLE PRESSURE GAUGE THREADED INSTALLATION TO INFLATION VALVE WAS LEAKING DUE TO MISSING TEFLON TAPE THREAD SEALANT. THREAD SEALANT WAS APPLIED AND PRESSURE GAUGE REINSTALLED.SDR DL76G060431Power Supply · inoperativeLEFT OVERWING SQUIB LIGHT WILL NOT TEST. REPLACED LEFT WING ESCAPE SYS PWR SUPPLY M961 AND BATTERY.SDR SWAA061784Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061764Cable · out of positionDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE HARDWARE OUT OF POSITION. REINSTALLED CABLE HARDWARE PER MM.SDR SWAA061762Slide · out of adjustDURING SCHEDULED 10Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061730Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061722Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. RE-INSTALLED EVAC SLIDE PER MM.SDR 2006UALA00978Slide · faultyFOUND DOOR 2L ESCAPE SLIDE IS DEPLOYED BUT NOT INFLATED. THIS ESCAPE SLIDE SLIPPED OUT OF ITS POSITION BUT DID NOT DEPLOY. ON SITE INVESTIGATION REVEALED SAFETY PIN WAS IN PLACE, HOWEVER, SAFETY PIN FELL DOWN ON GRD AFTER HANGING FROM A/C FOR ABOUT 30 MINUTESDR SWAA061721Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01171Latch · failedRT O/W COMP DOOR LATCH CHECK FAILED. REMOVE AND REPLACED LATCHES REF UAL B767, MM 25-68-98.SDR SWAA061707Slide · out of adjustFOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR QXEA200601330Slide · damagedPDX: C3. AFT PAX DOOR STEP SLIDER ASSY HAS ONE SCREW PULLED THROUGH TOP OF PLATE. MAINTENANCE REPAIRED IAW Q400 SRM 51-42-05 AND SRM 51-42-05.SDR HALA0600387Slide · unsafetiedCLEANERS FOUND CABLE HANGING FROM MAIN ENTRANCE DOOR SLIDE CHUTE COVERS. REPLACED FORWARD ENTRY DOOR SLIDE CHUTE ASSY PER AMM 25-61-01.SDR SWAA061705Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE GIRT BAR FITTING CORRODED AT BS 312, LBL 58. REMOVED AND REPLACED EVAC SLIDE GIRT BAR FITTING PER SRM.SDR SWAA061700Slide · out of adjustDURING SCHEDULED 10Y CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061699Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061693Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01025O-Ring · leakingLOW BOTTLE PRESSURE FILLER VALVE O-RING WAS LEAKING. REPLACED O-RING.SDR 2006UALA01026Bottle · lowLOW BOTTLE PRESSURE.SDR 2006UALA00988O-Ring · damagedFOUND LOW BOTTLE PRESSURE FILLER VALVE O-RING FOUND DAMAGED AND LEAKING. REPLACED FILLER VALVE O-RING.SDR 2006UALA00960Warning System · activatedRETURNED TO FIELD DUE TO A LEFT OVERWING SLIDE EICAS MESSAGE. UPON LANDING SLIDE WAS DEPLOYED BUT DID NOT INFLATE.SDR SWAA061678Slide · out of adjustDURING SCHEDULED 10Y CHECK, FOUND L2 DOOR EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061675Slide · out of adjustR1 DOOR EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01024Bottle · lowLOW BOTTLE PRESSURE.SDR 2006UALA00996Latch · failedLT OVERWING ESCAPE SLIDE COMPARTMENT DOOR LATCHES FAILED TORQUE CHECK. REPLACED LATCHES AND ACCOMP RIG CHECK. AIRCRAFT RETURNED TO SERVICESLIDE PROBLEM ROOT CAUSE WAS SUSPECTED TO BE IMPROPER TORQUE DURING INSTALLATION.SDR SWAA061671Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EMERGENCY EXIT EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA061660Slide · out of adjustR1 DOOR EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06146876Warning Buzzer · inoperativeINSPECTION TYPE:N/A ESCAPE SLIDE EMERGENCY WARNING HORN INOP. DFRD EVAC BUZZER PER MEL 52-73-01-2 ASSIGNED CONTROL M325596 PLACARD INSTALLED.SDR BB06037Light · failedDURING OPERATIONAL CHECK OF MED ESCAPE SLIDE, THE SLIDE MOUNTED LIGHTS FAILED TO ILLUMINATE. MAINTENANCE REPLACED THE SLIDE ASSEMBLY.SDR 2006UALA00989Housing · leakingTHE GAUGE BOTTOM HOUSING WAS LEAKING.SDR 2006UALA00946Slide · unserviceableR2 DOOR SLIDE PRESSURE IN THE RED. REPLACED SLIDE, INSTALLED AT DOOR 2 RIGHT. ACCOMPLISHED INSPECTION OF DOOR 2R SLIDE INSTALLATION.SDR SWAA061640Slide · out of adjustR1 EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 EVAC SLIDE PER MM.SDR SWAA061638Slide · low pressureR1 DOOR EMERGENCY EXIT EVAC SLIDE PRESSURE INDICATES LOW. REMOVED AND REPLACED R1 EVAC SLIDE PER MM.SDR 2006UALA00943Slide · failedEXT LOADS FWD L, SHOWS ON PTP AFTER EMERGENCY SYSTEM TEST. REPLACED BOTH RIGHT HAND AND LEFT HAND FORWARD SLIDES. BOTH REMOVED SLIDES DID NOT RING-OUT CORRECTLY AT THE CONNECTOR. OPS TESTED NORMAL WITH NEW SLIDES.SDR 2006UALA01011Slide · unknown1R MED SLIDE RAFT PRESSURE GAUGE AT BOTTOM OF GREEN BAND AFTER 5 HOURS ON GROUND.SDR 2006UALA00994Squib · no testFOUND EMERGENCY ESCAPE (RT) SQUIB DOES NOT TEST.SDR SWAA061619Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA061617Bracket · corrodedDURING SCHEDULED SPV CHECK, FOUND L1 DOOR EMERGENCY EXIT EVAC SLIDE CORRODED AT AFT GIRT BAR BRACKET. REMOVED AND REPLACED AFT GIRT BAR BRACKET PER MM.SDR SWAA061616Slide · out of adjustR1 DOOR EMERGENCY EXIT EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.
Back to JASC 2565