Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR BB06031Slide · inoperativeDURING L3 DOOR SLIDE OPERATIONAL CHECK, THE SLIDE LIGHTS FAILED TO ILLUMINATE. ONCE SLIDE WAS RELEASED FROM THE AIRCRAFT, LIGHTS ILLUMINATED. MAINTENANCE REPLACED THE SLIDE.SDR UPS06146660Warning System · intermittentECAM SLIDE INDICATION SYSTEM INTERMITTENT, REF M 322807. REPLACED SWITCH 13WN. SYSTEM OPS OK, REF MM 52-73-13-4.SDR SWAA061156Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UPS06146604Warning System · intermittentECAM SLIDE INDICATION SYSTEM INTERMITTENT, ITEM DEF. M 322807. ITEM DEF. M 322807 REF ALERT H-132546. REPLACES SWITCH 13WN. SYSTEM OPS OK. REF MM 52-73-13-4 DEFERRAL CLEARED.SDR SWAA061113Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR ASAA0640357Slide · no testDURING R 1 ESCAPE SLIDE TEST PER ASA TASKCARD 48125002 SLIDE DEPLOYED AUTOMATICALLY INTEGRAL LIGHT ILLUMINATED SLIDE INFLATED AND REMAINED EXCEPT SLIDE DEPLOYED SIDEWAYS (LEFT SIDE UP) INSTALLED NEW SLIDE.SDR 0600649620Slide · unwanted deployDURING MAINTENANCE ACTIVITIES AT MCO, THE TAIL CONE WAS INADVERTENTLY JETTISONED. THE TAIL CONE EMERGENCY ESCAPE SLIDE DID NOT DEPLOY AND DID NOT INFLATE. NO OBVIOUS REASON FOR FAILURE OF THE SLIDE TO DEPLOY WAS DETAILED. EVACUATION SLIDE WAS REPLACED AT MCOSDR SWAA061098Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA061091Slide · out of positionDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA061079Hook · looseDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED HOOK PER MM.SDR SWAA061078Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA061077Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA061068Hook · out of adjustR1 DOOR EMERGENCY EVAC SLIDE GIRT BAR HOOKS OUT OF ADJUST. ADJUSTED HOOKS PER MM.SDR 2006UALA00615Bottle · lowSLIDE AT DOOR 1R OUT OF GREEN BAND. REPLACED 1R SLIDE (MR25611-1035) WITH 1R SLIDE (MR25611-1191). SLIDES BEING REMOVED DUE TO LOW BOTTLE PRESSURE IS AN UNCOMMON EVENT. THE OPERATING ENVIRONMENT OF SLIDES SUCH AS VIBRATION, DOOR OPENING/CLOSING, CARTS IMPACSDR SWAA061082Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR SWAA061074Cable Assy · misroutedDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE ASSY MISROUTED. REROUTED CABLE ASSY PER MM.SDR CNMA20060006Slide · low pressureFAA RAMP CHECK FOUND DOOR SLIDE AT DOOR 3L PRESSURE LOW. REMOVED AND REPLACED DOOR SLIDE IAW M/M 25-66.SDR 2006UALA00617Slide · low pressureDOOR 1 LEFT SLIDE PRESSURE GAUGE IS BELOW GREEN BAND. 1L SLIDE (MR25822-1005) WAS REPLACED WITH 1L SLIDE (MR25822-1002) IN DEN PER AMM 25-62-44. INSPECTION OF THE SLIDE INSTALLATION WAS ACCOMPLISHED. OPERATING ENVIRONMENT (VIBRATION, DOOR OPENING/CLOSING, CASDR 2006UALA00592Support · looseRT OVERWING SLIDE LACING ATTACH NYLON FINGERS, 8 BROKEN, SUPPORTING TUBE LOOSE, LAYING ON SLIDE COMPARTMENT LWR SURFACE. ROOT CAUSE APPEARS TO BE OVER TIGHTENING DURING SLIDE OVERHAUL.SDR UPS06M46519Switch · stickingL1 DOOR EVAC SLIDE REMOTE PRESS TEST INOP. C/O T/S AND FOUND SWITCH STICKY. ADJUSTED REMOTE PRESS TO TEST SWITCH AND REPLACED BATTERIES PER SMP WORKS NORMAL NOW M322380 CLOSED.SDR 06FDEA1224Slide · failedRIGHT EVACUATION SLIDE FAILED TO DEPLOY WHEN DOOR OPENED. F/O PULLED MANUAL INFLATION LANYARD AND SLIDE INFLATED. THIS RT DOOR SLIDE NEEDS TO BE HELD FOR FLIGHT SAFETY & THE NTSB FOR IMPOUNDING. PLEASE REMOVE, TAG & ID WHERE PARTS ARE LOCATED AFTER REMOVAL.SDR 2006UALA00565Light · inoperativeDOOR 1L SLIDE EMERGENCY LIGHTS INOPERATIVE. REPLACED SLIDE, NO HELP. CONNECTOR 2871VC. FOUND DAMAGED, REPLACED. REINSTALLED DOOR 1R SLIDE, PER AMM 25-62-44. OPS CHECKED LIGHTS GOOD.SDR SWAA061010Cable Assy · misroutedDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE ASSY MISROUTED. REROUTED CABLE ASSY PER MM.SDR SWAA060987Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR UPS06146535Bottle · leakingCANNOT SEE SLIDE PRESSURE GAUGE ON MAIN CARGO DOOR. CHECKED DRAIN LINE FOR LEAKAGE; NO LEAKAGE FOUND AFTER 15 MINS. BEFORE LEAKAGE QUIT IT WAS 4 DROPS PER MIN WITHIN LIMITS IN ACCORDANCE TO M/M 71-00-00-2 PAR 3.SDR SWAA060951Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA060946Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR DL76L060208Latch · wornLEFT OVERWING SLIDE COMPARTMENT DOOR JAMMED, WOULD NOT OPEN. FOUND LINKAGE BETWEEN LATCH NR 3 AND NR 4 DISCONNECTED, FOUND NR 1 AND NR 2 LATCHES WORN AND OUT OF RIG. REPLACED NR 1, NR 2, AND NR 4 REPLACED PER AMM 25 65 06 P 401. LATCH RIGGING CHECKED AND ADSDR SWAA060943Slide · out of limitsR2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATES OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA060941Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR RYNA200600004Bottle · low pressureR3 DOOR EVACUATION SLIDE BOTTLE PRESSURE LOW, IN RED. REMOVED AND REPLACED EVACUATION SLIDE.SDR SWAA060932Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATES LOW. REMOVED AND REPLACED SLIDE PER MM.SDR DLM90060202Slide · no testL-1 DOOR SLIDE FAILED FUNCTIONAL CHECK OUT PER OPN 6800. SLIDE FAILED TO DEPLOY COMPLETELY. SLIDE P/N 100504-205, S/N D9F065, PACK DATE 05/24/05. REPLACED SLIDE AND FAILED THE SECOND TIME PER OPN 6800. SLIDE EMERGENCY LIGHTING WAS INOP ON THE FORWARD SIDE.SDR SWAA060904Window · missingL1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATOR VIEWER WINDOW MISSING. INSTALLED WINDOW PER MM.SDR SWAA060900Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA060885Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA060871Cable Assy · misroutedDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE ASSY MISROUTED. REROUTED CABLE ASSY PER MM.SDR UPS06146455Warning System · inoperativeFWD ENTRY DOOR EMERGENCY ESCAPE SLIDE WARNING BUZZER INOP DURING REST, IN ARM POSITION, LIGHT OPERATES NORMAL. PLACED ESCAPE SLIDE BUZZER ON DEFERRAL M-321840 PER MEL 52-73-01-2. PLACARD INSTALLED.SDR SWAA060848Hook · looseDURING SCHEDULED 10Y CHECK, FOUND R2 DOOR EVACUATION SLIDE GIRT BAR FWD RETAINER HOOK LOOSE. REPAIRED RETAINER HOOK PER MM.SDR UPS06146443Indicator · out of positionFOUND ESCAPE SLIDE PRESSURE GAUGE NOT VISIBLE FOR PREFLIGHT. REPOSITIONED GAUGE AS NEEDED.SDR SWAA060834Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L1 DOOR EVACUATION SLIDE FWD GIRT BAR FLOOR ATTACH FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR SWAA060811Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR SWAA060810Bracket · looseDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR FWD RETAINER HOOK LOOSE. SECURED RETAINER HOOK PER MM.SDR SWAA060779Slide · low pressureR1 DOOR EVACUATION SLIDE PRESS IND BELOW LIMITS. REMOVED AND REPLACED SLIDE ASSY PER MM.SDR DL76P060183Pin · missingWHILE WORKING EO 01-453956-03 ME 01 DISCOVERED LT OVERWING SLIDE DOOR ACTUATOR ROD DISCONNECTED AT FWD UPPER LATCH. REINSTALLED SAME.SDR 2006UALA00493Bottle · dischargedDOOR 2 RIGHT SLIDE BOTTLE PRESSURE LOW. IT WAS DETERMINED THAT ANY ONE OF THE FACTORS IN THE OPERATING ENVIRONMENT (VIBRATION, DOOR OPENING/CLOSING, CARTS IMPACTING DOORS, TEMPERATURE & PRESSURE CHANGES) COULD HAVE RESULTED IN BOTTLE LEAK. BOTTLE WAS REQUALSDR SWAA060821Slide · out of adjustR1 DOOR EVACUATION SLIDE OUT OF ADJUST. REPOSITIONED SLIDE ASSY PER MM.SDR 0600519930Slide · deployedDURING MAINTENANCE ACTIVITIES AT LGA TAIL CONE WAS INADVERTENTLY DEPLOYED FROM AFT INSIDE HANDLE. THE TAIL CONE EMERGENCY SLIDE DID NOT DEPLOY. NO OBVIOUS REASON FOR FAILURE TO DEPLOY WAS FOUND. LGA MAINTENANCE TEMPORARILY REPAIRED DAMAGE TO TAIL CONE AFT SDR SWAA060778Slide · looseL1 DOOR EVACUATION SLIDE DISLODGED FROM COVER. REINSTALLED SLIDE PER MM.SDR SWAA060796Bracket · looseDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EVACUATION SLIDE GIRT BAR FWD ATTACH HOOK BRACKET LOOSE. SECURED HOOK BRAKET PER SRM.
Back to JASC 2565