Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025020302179Slide · faultedDOOR-MOUNTED ESCAPE SLIDE PACK ASSEMBLY INSTALLATION - PAPERWORK VERIFACATION R/R L4 DOOR SLIDE PER JOB CARD 78-2561-9-0007 OPS CK NORMAL.SDR CALA2025020302178Slide · not reported1L DOOR SLIDE REMOVED AND REPLACED. WORKLOAD ITEM.SDR CALA2025020302177Indicator · damagedSEAT ROW 2, 25 OVERHEAD SLIDE TAMPER INDICATOR DAMAGED. REPLACED SEAT ROW 2, 25 OVERHEAD SLIDE TAMPER INDICATOR WITH REF TO AMM: 25-64-00/201.SDR CALA2025020302176Slide · unpackedDOOR 1R EMERGENCY EXIT SLIDE MATERIAL NEEDS REPACKED FOUND SLIDE MATERIAL EXCESSIVLY HANGING OUT REQUIRING REMOVAL OF SLIDE PACK, REMOVED SLIDE PACK IN REF WITH AMM-25-66-01-000-802, COMPLETED ZFOLD AND TUCKED THE EXCESSIVE GIRT MATERIAL AS NEEDED AND REINSTALSDR SWAA2025013091395Bracket · tightFORWARD SERVICE DOOR GIRT BAR BRACKETS VERY TIGHT<[01] LUBRICATED GIRT BAR CLIPS AND GIRT BAR AT R1 DOOR. PERFORMED GIRT BAR INSPECTION CHECK IAW AMM 25-66-01; NO DEFECTS NOTED.SDR SWAA2025013091201Girt Bar · draggingL2 DOOR SLIDE GIRT DRAGGING<[01]. REPACKED L2 DOOR SLIDE GIRT PER AMM 25-66-01.SDR SWAA2025013091202Girt Bar · draggingR2 DOOR SLIDE GIRT DRAGGING<[01] REPACKED R2 DOOR SLIDE GIRT PER AMM 25-66-01.SDR DALA2025013000742Lanyard · unsecureSHIP 5807 4L DOOR SLIDE/BUSTLE HAS ROPE HANGING FROM DOOR. CORRECTIVE ACTION: RESTOWED ROPE, SECURITY CHECK GOOD. (6580656)SDR SWAA2025013090686Slide · jammedWHILE PERFORMING SAMPLE OF AFT SERVICE DOOR ESCAPE SLIDE; DOOR BECAME JAMMED BECAUSE SLIDE COMPARTMENT DID NOT OPEN WITH LOWER LATCH RELEASED. WHEN DOOR WAS FORCED OPEN; SLIDE DROPPED AND DEPLOYED<[01]. INSPECTED DOOR AND ESCAPE SLIDE ENCLOSURE; NO DEFECTS NSDR SWAA2025013090985Slide · out of positionEXCESSIVE ESCAPE SLIDE MATERIAL HANGING OUT OF CASE @ L2 ( AFT ENTRY ) DOOR<[01]. RE-POSITIONED ESCAPE SLIDE REF AMM 25-66-01.SDR SWAA2025013090647Slide · wornAFT GALLEY SERVICE DOOR ESCAPE SLIDE SKIRT WORN<[01]. R&R AFT GALLEY SERVICE DOOR ESCAPE SLIDE IAW AMM 25-66-01. REF. BARCODE TTG8Q00LJE73; [02] INSPECTION C/W R&R AFT GALLEY SERVICE DOOR ESCAPE SLIDE IAW AMM 25-66-01. REF. BARCODE TTG8Q00LJE73.SDR SWAA2025013091376Girt Bar · looseFLIGHT ATTENDANT REPORTS THAT THE AFT ENTRY DOOR GIRT BAR IS LOOSE<[01] SECURED AFT ENTRY DOOR GIRT BAR PER S.I.P.SDR DALA2025013000724Safety Pin · missingMISSING SAFETY PIN OF SLIDE R1 DOOR. THIS COULD PREVENT THE PROPER OPERATION OF THE ESCAPE PATH AND IT IS NOT IN COMPLIANCE WITH 14 CFR PART 121.703. SUMMARY OF THE NRC 00084: SAFETY PIN WAS INSTALLED ON SLIDE R1 DOOR PER B717-200 AMM 25-61-03-000-801 STEP B.(SDR YENA2025012900122Slide · abnormalFLT#2694, NAS-FLL. 'WHILE WORKING MDDR # 571952 R1 ARM/DISARM INDICATION. NOTICED MINUMUM SLIDE ESCAPE UNRAVEL. SAFETY PIN WAS INSTALLED ON REGULATOR AND SLIDE WAS NOT DEPLOY. REMOVED R1 DOOR SLIDE ESCAPE SLIDE IN REF TO AMM 25-62-44; INSTALLED R1 ESCAPE SLIDESDR AALA202501297157Slide Raft · no testAIRCRAFT WAS NOT GROUNDED: DURING EMERGENCY POWER SUPPLY UNIT SYSTEM CIDS TEST, EMERGENCY POWER SUPPLY UNIT 10WL FAULT MESSAGE DISPLAYED. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 10WL (AALA202501295562) PER AMM 33-51-38 AND THE L1 DOOR SLIDE RAFT ASSEMSDR SWAA2025012890226Slide · out of adjustPASSENGER CABIN L2 DOOR SLIDE CURTAIN CATCHES ON LOWER DOOR SILL<[01] DUPLICATE WRITEUP. REFERENCE BARCODE TTG8Q00YDEM8SDR SWAA2025012890224Slide · out of adjustPASSENGER CABIN R2 DOOR SLIDE CURTAIN CATCHES ON LOWER DOOR SILL<[01] REPACKED R2 DOOR SLIDE GIRT PER AMM 25-66-01.SDR CALA2025013002139Slide · exposedAFT SLIDE DOOR 2R EXPOSED YELLOW SHOWING REPOSITIONED EXCESS GIRT MATERIAL BACK INTO SLIDE PACK COVER REF AMM 25-66-01. NO FURTHER EXPOSED YELLOW SLIDE SHOWING.SDR CALA2025013002136Bustle · looseDOOR 4R SLIDE BUSTLE IS REPORTED LOOSE WHEN ARMED D4R SLIDE BUSTLE REPOSITIONED BACK INTO POSITION AND SECURED. NIL ABNORMALITIES OBSERVED DURING INSPECTION.SDR CALA2025013002130Bottle · low pressureDOOR 2R SLIDE PACK GAGE IN RED NEEDLE ON HIGHSIDE. WITH IN LIMITS. OK FOR SERVICESDR WX0A2025012732281Slide · unwanted deploy(AIRCRAFT NOT GROUNDED) R-2 DOOR SLIDE DEPLOYED / REFERENCE NR 3, NR 6 W/O 512619 R2 DOOR SLIDE R/R WORK COMPLETION. (RESOLVED ON W/O: 512619 TASKCARD: NR-00002 ) REMOVED R2 DOOR SLIDE IAW AMM 25-62-44-000-805-AITEM: 1REMOVED R2 DOOR SLIDE IAW AMM 25-62-44-000SDR AALA202501286273Slide Raft · not reportedAIRCRAFT WAS GROUNDED: R2 DOOR SLIDE ASSY NEEDS REPLACEMENT. MAINTENANCE REPLACED R2 DOOR SLIDE I.A.W. WORK CARD 72L80025001.SDR SCNA20250128033Cover · brokenDEFECT 796983: 2L SLIDE HOUSING COVER BROKEN. RESOLUTION: REAPPLIED 2L SLIDE HOUSING COVER REF AMM 25-66-00 OK FOR SERVICESDR SWAA2025012789707Slide · looseESCAPE SLIDE FORWARD ENTRY DOOR( L1) LOOSE<[01] RE-SECURED.L1 DOOR SLIDE IN REF. WITH AMM25-66-01; NO DEFECTS NOTED AT THIS TIME.SDR AALA202501271687Slide Raft · out of positionAIRCRAFT WAS GROUNDED: FLIGHT CREW FOUND THE AFT RIGHT CABIN DOOR ESCAPE SLIDE GIRT BAR HANGING OUTSIDE OF AIRCRAFT. MAINTENANCE REPLACED THE SLIDE RAFT ASSEMBLY PER TASK CARD 26L00025011.SDR SWAA2025012789563Slide Raft · dislodgedL1 DOOR RAFT FELL OUT OF DOOR (ESCAPE SLIDE)<[01] SECURED L1 DOOR SLIDE IN CONTAINER PER M/M 25-66-01 AND MT #725-SWA-105. SLIDE SECURED / INSTALLED BY EMP #141028.SDR SWAA2025012789467Bottle · low pressureAFT SERVICE DOOR SLIDE PRESSURE BELOW LIMITS<[01] REMOVED AND REPLACED AFT SERVICE DOOR SLIDE PER SWA MT 725-61-06-AS AND AMM 25-66-01.SDR IPXA2025012581071Bottle · lowR1 DOOR SLIDE LOW PRESSURE. VERIFIED SAFETY PIN REMOVED AND GIRTH BAR ENGAGED REF AMM 26-61-15.SDR IPXA202501277835Slide · inoperativeDURING PREFLIGHT EMG DOOR SLIDE PRESSURE IN RED LEVEL ZONE. VERIFIED SAFETY PIN REMOVED , SAFETY BAR ENGAGED , ALL LIGHTS NORMAL , NO FAULT AT THIS TIME .. REF AMM , 52-10-00.SDR DALA2025013100762Bottle · inoperativeSHIP 5810 OVERWING SQUIB TEST LEFT BOTTLE PRESSURE TEST 2 WILL NOT ILLUMINATE. CORRECTIVE ACTION: REPLACED LEFT OVERWING EMERGENCY ESCAPE SLIDE INFLATOR PER AMDS 2565-4646-LH. OPS CHECK NORMAL. (6580321)SDR AALA202501276654Slide Raft · bindingAIRCRAFT WAS GROUNDED: L1 DOOR HARD TO ARM. MAINTENANCE REPLACED THE L1 DOOR ESCAPE SLIDE IAW JC 26L00025011.SDR SWAA2025012789283Shroud · misinstalledFWD ENTRY DOOR SLIDE SHROUD NOT INSTALLED PROPERLY AT BOTTOM CENTER OF SHROUD<[01] INSTALLED CORRECTLY FWD ENTRY DOOR-SLIDE IAW AMM 25-66-01-400-801.;[02] INSTALLED CORRECTLY FWD ENTRY DOOR-SLIDE IAW AMM 25-66-01/401-MT 725-61-06.;[03] VERIFIED CORRECTIVE ACTISDR SWAA2025012889174Battery Pack · inoperativeAFT LEFT(L732) AND RIGHT(L733) ESCAPE SLIDE LIGHTS ARE INOP. FUTHER INVESTIGATION ALL AFT AREA EMERGENCY LIGHT INOP SUSPECTED BATTERY PACK M1673 M1672 M1671 NEED TO BE REPLACE. REPLACED POWER SUPPLY - BATTERY PACKS TO M1673; M1672 AND M1671 PER AMM 33-51-0SDR AALA202501270522Girt Bar · misinstalledAIRCRAFT IN BASE MAINTENANCE: R1 SLIDE ARMED INDICATION INTERMITTENT ON POST CHECK FCF. MAINTENANCE INSTALLED CORRECTLY GIRT BAR ASSEMBLY ESCAPE SLIDE R1 IAW AMM 25-62-44-400-802-A STEP 4.A (5).(D) 2. AND PERFORMED OPERATIONAL TEST EMERGENCY ESCAPE SLIDE RELEASDR DALA2025012700644Pin · installedSHIP 3356 3R SLIDE DOES NOT SHOW DISARMED. FA REPORTED PIN IS IN. CORRECTIVE ACTION: R/R DOOR SLIDE PER A330 AMM 25-61. OK FOR SERVICE. (6479130)SDR CALA2025012702076Slide · damagedSLIDE PACK DAMAGED DOOR 1R INSPECTED SLIDE PACK OF 1R DOOR AND FOUNDED WITHIN LIMITS IN REF TO AMM TASK 25-66-01-400-804, NO FURTHER DEFECTS NOTED AT THIS TIME.SDR CALA2025012702075Bustle · looseESCAPE SLIDE PACK BUSTLE LOOSE 1R. REMOVED R1 DOOR SLIDE ASSY AND INSTALLED SAFETY PIN IAW AMM 25-66-01-000-801. REPACKED THE GIRT IAW AMM 25-66-01-601-804. REMOVED SAFETY PIN AND REINSTALLED R1 DOOR SLIDE ASSY IAW AMM 25-66-01-400-801. OBSERVED SAFTY AND SESDR DALA2025012400620Slide · dislodgedSHIP 6815 DOOR 2L WILL NOT OPEN FOR DEPLANING. CORRECTIVE ACTION: FOUND SLIDE ASSY HARNESS HAD LOOSENED & SLIDE BUSTLE DROPPED DOWN IMPEADING DOOR OPERATION. SECURED SLIDE BUSTLE PER B757 AMM 25-66. DOOR OPERATES NORMAL. (6942150)SDR DALA2025012400619Slide · fodSHIP 6816 4R DOOR SLIDE LIGHT WILL NOT ILLUMINATE WITH DOOR CLOSED AND ARMED. CORRECTIVE ACTION: REMOVED DEBRIS FROM BOTTOM OF DOOR SLIDE. LIGHT WORKS NORMAL. REFERENCE B757 AMM25-66. (6607906)SDR SWAA2025012489230Slide · out of positionCREW REQUEST AFT ENTRY DOOR SLIDE TO BE REPOSITIONED IN THE SLIDE COMPARTMENT.<[01] REPOSITIONED AE DOOR SLIDE INSIDE THE COMPARTMENT PER MT 725-61-06.SDR WX0A2025012432280Latch Pin · not seated(AIRCRAFT NOT GROUNDED) RIGHT OVERWING SLIDE DOES NOT SHOW ARMED / PERFORMED TSM 52-21-00-810-809-A. RESEATED ARMING LATCH PIN & OPS CHECK GOOD"SDR WX0A2025012432279Indication Sys · false indication(AIRCRAFT NOT GROUNDED) R1 SLIDE INTERMITTENT INDICATION ON THE GROUND / PERFORMED OPERATIONAL TEST OF R1 SLIDE INDICATION IAW AMM 25-62-44-400-802-A. OPS CHECK GOOD, A/C OK FOR CNT SVC "SDR CALA2025012302000Slide · out of position1R SLIDE MISALIGNED INSPECTED SLIDE COVER INSTALLATION FOR SECURITY. NO FAULTS NOTED. RETUCKED Z FOLD IN GIRT TO PROPER DIMENSION PER AMM SUBTASK 25-66-01-420-003.SDR IPXA2025012423113Bustle · unsecure*EMERGENCY SLIDE BUSTLE ON CREW DOOR NOT SECURED TO DOOR AND DAMAGED. REMOVED AND REPLACED EMERGENCY SLIDE DECORATIVE COVER AND SECURED SAME DOOR CKS GOOD REF A300 AMM 25-61-21SDR CALA2025012402024Latch · out of adjustSLIDE AT DOOR4R HAS LARGE GAP ADJUSTED SLIDE COVER LATCH. RESECURED SLIDE COVER. AMM REF 52-11-24 ADD EMP:379788SDR AALA202501228244Slide Raft · deployedAIRCRAFT WAS GROUNDED: R4 DOOR SLOOR SLIDE PARTIALLY DEPLOYED. REPLACED R4 DOOR ESCAPE SLIDE/RAFT PER JOB CARD 26L00025011.SDR CALA2025012302001Cover · unsecureSLIDE PACK COVER DOOR 2R COMING LOOSE VERIFIED FOR TIGHTNESS AND SECURITY OF COVER AND MOUNTING HARDWARE. SLIDE PACK BUSTLE IS SECURED IN PLACE. REF AMM. 25-66-01.SDR CALA2025012301997Slide · dislodged2R SLIDE COVER HAS BIG GAP SLIDE COVER ON DOOR 2R IS IN NORMAL CONDITION IN REF TO AMM 25-66-01SDR CALA2025012301992Slide · dislodgedFWD ENTRY DOOR SLIDE IS PARTIALLY STICKING OUT OF CASE UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC METER INITIATED FOR WITH VENDOR ID MAC RELATED WORK ORDER 000000003127480 AND PRTR RE-TUCKED LOOSE SLIDESDR CALA2025012201965Slide · dislodgedR1 DOOR ESCAPE SLIDE IS HANGING DOWN. RETUCKED "Z" FOLD IN GIRT TO PROPER GIRT DIMENSION. REF AMM SUB TASK 25-66-01-420-002 2(D).
Back to JASC 2565