Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CHQA000580Slide · dislodgedAFTER ARRIVING AT THE GATE ON FLIGHT 7702 FROM IAH TO IAD, THE FLIGHT ATTENDANT COULD NOT OPEN THE EXIT DOOR. THE GIRT BAR WOULD NOT FULLY DISENGAGE FROM THE ACTIVATED POSITION. WHEN THE DOOR WAS OPENED FROM THE OUTSIDE, THE SLIDE DID NOT DISCONNECT FROM THESDR AWXA200401284Slide · frayedMCN - EES - DURING C-15 CHECK THE R-2 DOOR EMERGENCY ESCAPE SLIDE WEBBING WAS FOUND FRAYED. MAINTENANCE REPLACED THE R-2 DOOR EMERGENCY ESCAPE SLIDE WEBBING IAW B737-300 SRM 51-40-02 FIG 3-4, & 6-8.SDR SWAA043211Cable · misroutedDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EVAC SLIDE DOOR GIRT BAR CABLE MISROUTED. REROUTED L2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA043208Cable · frayedDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EVAC SLIDE GIRT BAR CABLE FRAYED. REMOVED AND REPLACED R2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA043204Cable · misroutedDURING SCHEDULED C4 CHECK, FOUND L2 DOOR EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED L2 DOOE EVAC DOOR SLIDE CABLE PER MM.SDR SWAA043203Cable · frayedDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EVAC SLIDE DOOR GIRT BAR CABLE FRAYED. REMOVED AND REPLACED R2 DOOR EVAC SLIDE GIRT BAR CABLE PER MM.SDR SWAA043199Cable · misroutedDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED R2 DOOR EVAC SLIDE DOOR CABLE PER MM.SDR SWAA043197Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043195Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043193Cable · misroutedDURING SCHEDULED C4 CHECK, FOUND L2 DOOR EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED L2 DOOR EVAC SLIDE CABLE PER MM.SDR 2004UALA01000Cable · brokenDOOR 2R WILL NOT ARM. THE CABLE AT BOTTOM OF SLIDE/RAFT ASSY WAS FOUND BROKEN WHICH DISRUPTED THE NORMAL FUNCTION OF EMERGENCY SELECTOR MECHANISM. THE SLIDE RAFT CABLE SYSTEM IN THE SLIDE LOWER LACING COVER IS A SENSITIVE DESIGN. RELEASING THE CABLE SYSTEM SDR SWAA043189Cable · misroutedDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EVAC SLIDE CABLE MISROUTED. REROUTED R2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA043177Slide · out of adjustL1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA043175Cable · misroutedDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED R2 DOOR EVAC SLIDE CABLE PER MM.SDR SWAA043173Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR SWAA043169Slide · dislodgedL1 DOOR EVACS SLIDE FELL OUT. REINSTALLED L1 DOOR EVAC SLIDE PER MM.SDR 2004UALA01032Hose · out of positionSLIDE HOSE WAS PACKED INTO ONE FOLD ON THE RIGHT FRONT CORNER. SLIDE ASSEMBLY PREVIOUSLY PACKED INCORRECTLY. REPACKED SLIDE TO SPECIFICATIONS.SDR 2004UALA01031Slide · puncturedESCAPE SLIDE HAS A PUNCTURE ON LOWER INFLATION CHAMBER. PATCHED PER AIR CRUISERS CMM 25-61-32 WITH THREE INCH CIRCLE--PRESSURE TESTED, NO LEAKS. CAUSE OF PUNCTURE IS UNKNOWN.SDR 2004UALA01026Tape · separatedSLIDE RAMP HINGE TAPE SEPARATED DURING OVER PRESSURE TEST. THE TAPE SEPARATION COULD BE ATTRIBUTED TO ADHESIVE FAILURE. THE UNIT WAS SENT TO OEM (AIRCRUISERS) FOR REPAIR.SDR 2004UALA01025Tape · separatedHINGE TAPE IN SLIDE RAMP SEPARATED DURING OVER PRESSURE. THE TAPE SEPARATION COULD BE ATTRIBUTED TO ADHESIVE FAILURE. THE UNIT WAS SENT TO OEM (AIRCRUISERS) FOR REPAIR.SDR 2004UALA01005Battery Pack · dischargedPOSITION 1 EMERGENGY ESCAPE SLIDE SQUIB LIGHT FAILED TO ILLUMINATE DURING TEST. DEFECT CAUSED BY LOW BATTERY. REPLACED LEFT HAND BATTERY PACK.SDR SWAA043178Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 & R2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED R1 & R2 DOOR EVAC SLIDES PER MM.SDR SWAA043167Girt Bar · inoperativeR2 DOOR EVACUATION SLIDE GIRT BAR WOULD NOT ARM AT FLOOR BRACKETS. REMOVED AND REPLACED SLIDE ASSY PER MM.SDR UPS04M43431Warning Light · illuminatedINSPECTION TYPE:N/A, R1 SLIDE LOW PRESS LIGHT INOP. VERIFIED SYS PRESS, OK FOR SERVICE PER DMP 25-61-2.SDR 2004UALA00997Battery · dischargedRIGHT OVERWING SLIDE SQUIB DOES NOT TEST IN POSITION 1. DEFECT CAUSED BY LOW BATTERY. REPLACED RIGHT HAND BATTERY.SDR UPS04M43432Light · incorrectINSPECTION TYPE:N/A, L1 DOOR SLIDE PRESS TO TEST INDICATION SYSTEM INOP. CHECKED CONTINUITY OF PRESS SWITCH. NO CONTINUITY ON SWITCH. PRESS SWITCH & BOTTLE PRESS OK PER WDM 25-61-01. FOUND WRONG BULBS INSTALLED IN REMOTE PRESS INDICATOR & HIGH RESISTANT SHSDR 2004UALA00995Bracket · brokenSLIDE ASSEMBLY STEP BRACKET BROKEN. STEP BRACKETS OF SLIDE/RAFTS (LT & RT) ARE THE TWO BOTTOM ATTACHMENT POINTS THAT HOLD THE SLIDE/RAFT ONTO THE AIRCRAFT DOOR. THESE PARTS ARE STICKING OUT OF THE WHOLE ASSEMBLY AND ARE LIABLE TO DAMAGE ESPECIALLY DURING TRASDR SWAA043145Girt Bar · out of positionDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EVACUATION SLIDE GIRT BAR OUT OF POSITION. REPOSITIONED GIRT BAR PER MM.SDR SWAA043143Slide · out of adjustDURING SCHEDULED SERVICE CHECK, FOUND BOTH R1 & R2 DOOR EVACUATION SLIDES OUT OF ADJUST. REPOSITIONED BOTH SLIDES PER MM.SDR SWAA043140Cable · frayedDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EVACUATION SLIDE RELEASE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR SWAA043139Slide · dislodgedR2 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. INSTALLED SLIDE ASSY PER MM.SDR 2004UALA00994Valve · separatedVALVE ASSEMBLY PASSED LOW VOLUME LEAK CHECK AT 3000 PSI FOR 24 HOURS. DURING FILL PROCESS AT 1500 PSI THE VALVE SEPARATED FROM CYLINDER AT BOTTLE ADAPTER. THE CRACKED FITTING WAS MADE OF ALUM 7075-T6 OR 2024-T4. NEW FITTINGS MADE OF SUPERIOR MATERIAL 7075-TSDR UPS04143418Button · stickingENTRY DOOR ESCAPE SLIDE TEST BUTTON STICKS DURING TEST. CLEANED TEST BUTTON, OPS NORMAL.SDR AALA20041077Slide · failedGIG - DURING SERVICING L1 MAIN ENTRY DOOR WAS INADVERTENTLY DEPLOYED BY AGENT AND SLIDE FAILED TO INFLATE. SLIDE ASSEMBLY NOT AVAILABLE AT GIG FOR REPLACEMENT. DEACTIVATED LEFT ONE MAIN ENTRY DOOR AND PLACARD PER MEL 52 02. ISOLATED FIRST CLASS SEATS FROM RSDR SWAA043122Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R2 AND L1 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED BOTH R2 AND L1 DOOR EVAC SLIDES PER MM.SDR SWAA043131Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR GTIA040823Lanyard · disconnectedR1 DOOR EMERGENCY SLIDE LANYARD DISCONNECTED. SECURED R1 DOOR EMERGENCY SLIDE LANYARD, OK FOR SERVICE.SDR SWAA043116Latch · looseDURING SCHEDULED C4 CHECK, FOUND L2 DOOR EVAC SLIDE GIRT BAR FWD FLOOR LATCH LOOSE. SECURED L2 DOOR EVAC SLIDE FWD FLOOR LATCH PER MM.SDR SWAA043110Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR SWAA043109Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR GTIA040822Lanyard · looseL1 DOOR GIRT BAR WAS DIFFICULT TO UNLATCH. FOUND LANYARD LOOSE, RESECURED LANYARD AND CLEANED GIRT BAR LATCH, OPS CHECK GOOD.SDR 2004UALA00984Proximity Sensor · malfunctionedDOOR 1L SLIDE LIGHT WILL NOT COME ON WHEN DOOR IS ARMED. REPLACED DEFECTIVE GIRT BAR PROXIMITY SENSOR.SDR 2004UALA00975Girt Bar · looseGIRT BAR DOOR 1L DOES NOT STAY IN PLACE. SHOP FINDINGS FROM INSPECTION OF THE SLIDE UNIT REVEALED A LOOSE GIRT BAR SLEEVE. THE LOOSE GIRT BAR WAS REPAIRED AND THE SLIDE UNIT WAS RETURNED TO SERVICE.SDR SWAA043082Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR AALA20041067Slide · inoperativeBOS - L3 DOOR SLIDE INFLATION BOTTLE FOUND AT ZERO. REMOVED AND REPLACED SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR EM04019Slide · deployedFLIGHT 1684, UPON ARRIVING IN PIT FOUND THE GIRT BAR WAS INADVERTENLY RELEASED FROM THE DOOR CLIP CAUSING PARTIAL SLIDE DEPLOYMENT ON THE 1L DOOR SLIDE. MAINTENANCE REPLACED SLIDE AND SERVICED DOOR PNEUMATIC BOTTLE.SDR SWAA043073Slide · out of limitsDURING SCHEDULED A1 CHECK, FOUND R1 DOOR EVAC SLIDE IND OUT OF LIMITS. REMOVED AND REPLACED R1 DOOR EVAC SLIDE PER MM.SDR SWAA043072Cable · frayedDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED L2 DOOR EVAC SLIDE CABLE PER MM.SDR MWEA040194Slide · dischargedAFT GALLEY SLIDE PRESSURE INDICATOR IS INDICATING IN THE RED (READS 2000 PSI). REMOVED AND REPLACED AFT GALLEY DOOR SLIDE.SDR SWAA043055Slide · out of adjustDURING SCHEDULED HC2D CHECK, FOUND R1 AND R2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED R1 AND R2 DOOR EVAC SLIDE PER MM.
Back to JASC 2565