JASC 2565

Service difficulty reports · 26,821

Reports filed under 2565 · Escape Slide, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2565'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 97UAL900664Tube · wornDURING SHOP OVERHAUL OF SLIDE/ RAFT REMOVED FOR TIME EXPIRATION, IT WAS FOUND THAT THE LOWER TUBE RELIEF VALVE HAD WORN A HOLE INTO THE LOWER TUBE. THE HOLE WAS REPAIRED WITH AN OUTSIDE PATCH.Aug 25, 1997 · N585UA · Boeing 757222SDR 97UAL900641Slide · defectiveFORWARD ENTRY DOOR 1L SLIDE DEFECTIVE. *S/D* REPLACED 1L SLIDE WITH NEW SLIDE. HOME SHOP REPORTED THAT GIRT RESTRAINING BUNGEE ATTACH POINT REINFORCING PATCHES WERE FOUND TO BE DISBONDING.Aug 21, 1997 · N987UA · Boeing 737291SDR 97UAL900634Valve · corrodedDURING OVERHAUL OF SLIDE, REMOVED FOR TIME EXPIRATION FOUND INFLATION FLOW CONTROL VALVE BODY (P/N 525S0002) AND SPRING (P/N 525S0003) CORRODED. REPLACED VALVE ASSEMBLY (P/N D18287107) COLD DOOR. A HEATER HAS NOT BEEN ADDED TO THE DOOR AS HAS BEEN DONE TO THAug 21, 1997 · N555UA · Boeing 757222SDR MWEA97741Slide · defectiveDURING TRANS CHECK, FOUND EMERG GALLEY SLIDE PRESS LOW. MTC REMOVED AND REPLACED SLIDE.Aug 19, 1997 · N900ME · Doug DC915SDR CALA9701231Slide · low pressureINSPECTION FOUND THE L-2 DOOR EMERGENCY SLIDE PACK PRESSURE LIGHT ILLUMINATED. THE L-2 DOOR SLIDE WAS REMOVED AND REPLACED.Aug 19, 1997 · N15069 · Doug DC1030SDR ASAA9780180L2 Door · failed testOAK - DURING C-CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)Aug 19, 1997 · N979AS · Doug DC983SDR ASAA9780179Slide · failed testOAK - DURING C-CHECK, THE R1 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMPE TEST. REPLACED THE R1 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)Aug 19, 1997 · N979AS · Doug DC983SDR ASAA9780178Inflation Bottle · low pressureOAK - DURING C-CHECK, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE L1 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)Aug 19, 1997 · N979AS · Doug DC983SDR SWAA970784Slide · low pressDURING SERVICE CHECK, FOUND R1 FLOOR SLIDE PRESSURE LOW. REPLACED PER BOEING M/M.Aug 17, 1997 · N368SW · Boeing 7373H4SDR SWAA970787Slide · low pressDURING SERVICE CHECK, FOUND R2 DOOR SLIDE PRESSURE LOW. REPLACED PER BOEING M/M.Aug 14, 1997 · N673AA · Boeing 7373A4SDR MALA975655Escape Slide · looseDURING MAINTENANCE, THE PASSENGER ESCAPE SLIDE FELL OUT. MAINTENANCE REPLACED PASSENGER DOOR ESCAPE SLIDE ASSEMBLY IAW AVRO MM 25-60-11. (X)Aug 14, 1997 · N504XJ · Bac AVRO146RJ85ASDR SWAA970699Slide · low pressDURING A1 CHECK, FOUND R2 DOOR SLIDE PRESSURE LOW. REPLACED PER BOEING M/M.Aug 11, 1997 · N355SW · Boeing 7373H4SDR AALA971436Slide · low pressureDFW - DURING OVERNIGHT CHECK, EMERGENCY EVACUATION SLIDE AT FORWARD SERVICE DOOR INDICATED LOW BOTTLE PRESSURE. REPLACED EMERGENCY EVACUATION SLIDE AT FORWARD SERVICE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 10, 1997 · N7527A · Doug DC982SDR AWXA9700437Slide · deployed2-L DOOR SLIDE INADVERTENTLY DEPLOYED. REMOVED 2-L DOOR SLIDE, PLACED IN AFT PIT AND FERRIED TO PHX. REPLACED SLIDE ASSEMBLY.Aug 9, 1997 · N643AW · Airbus A320231SDR SWAA970681Slide · low pressDURING WALKAROUD CHECK, FOUND R2 DOOR SLIDE PRESSURE LOW. REPLACED PER BOEING M/M.Aug 7, 1997 · N395SW · Boeing 7373H4SDR DLL14971585Slide · malfunctionedFOUR RIGHT DOOR DID NOT OPEN AND THE SLIDE DID NOT DEPLOY DURING EVACUATION. FOUND 'T' HANDLE NOT FULLY DEPLOYED, OPS CHECK NORMAL.Aug 7, 1997 · N740DA · Lkheed 1011385115SDR 98ZZZM95Slide · deployedWITH A/C IN HANGAR FOR RON MX, REAR RT DOOR OPENED AND SLIDE WAS NOT DSIARMED AND WAS DEPLOYED DUE TO BEING UNSAFE. REMOVED AND REPLACED SLIDE. (M)Aug 5, 1997 · N612AW · Bag BAE146300ASDR MWEA97715Slide · deployedDURING C-CHK, TAIL SLIDE INADVERTENTLY DEPLOYED. MTC REMOVED AND REPLACED TAIL SLIDE IAW AFT ACCESSORY PLACARD.Aug 4, 1997 · N502ME · Doug DC932SDR 9714969985Slide · low batteryDURING PERIODIC CHECK, MAIN CABIN DOOR EVACUATION SLIDE FAILED BATTERY TEST. REPLACED SLIDE.Aug 4, 1997 · N985US · Doug DC932SDR SWAA970670Slide · low pressDURING WALKAROUNBD CHECK, FOUND FWD ENTRY DOOR SLIDE PRESS LOW. REPLACED PER BOEING M/M.Aug 1, 1997 · N519SW · Boeing 7375H4SDR CALA9701161Slide · zero pressureINSPECTION FOUND THE R-2 DOOR ESCAPE SLIDE WITH ZERO PRESSURE. THE SLIDE WAS REMOVED AND REPLACED.Aug 1, 1997 · N12231 · Boeing 737217SDR SWAA970692Slide · low pressDURING WALKAROUND CHECK, FOUND FWD ENTRY DOOR SLIDE PRESSURE LOW. MX FERRIED TO OAK. REPLACE PER BOEING M/M.Jul 31, 1997 · N519SW · Boeing 7375H4SDR SWAA970650Slide · low pressDURING SCHEDULED SERVICE CHECK, FOUND AFT DOOR SLIDE PRESSURE BELOW MINIMUM. REPLACED SLIDE ASSEMLY PER BOEING M/M.Jul 29, 1997 · N302SW · Boeing 7373H4SDR 97UAL900609Tube · failedDURING SHOP OVERHAUL OF SLIDE, THE LOWER TUBE FAILED THE AIR RETENTION TEST DUE TO POROSITY IN THE INFLATABLE MATERIAL. SLIDE SENT TO VENDOR FOR REPAIR OR REPLACEMENT.Jul 29, 1997 · N601UA · Boeing 767222SDR SWAA970654Slide · low pressDURING WALKAROUND CHECK, FOUND AFT RIGHT DOOR SLIDE PRESS LOW. REPLACED PER BOEING M/M.Jul 25, 1997 · N350SW · Boeing 7373H4SDR SWAA970631Slide · low pressureDURING WALKAROUND CHECK, FOUND FWD ENTRY DOOR SLIDE PRESSURE BELOW SERVICEABLE LIMITS. REPLACED PER BOEING M/M.Jul 20, 1997 · N354SW · Boeing 7373H4SDR DLM88971413Slide · inflatedLT AFT GALLEY SLIDE FELL OUT AND INFLATED. REPLACED LT AFT GALLEY SLIDE.Jul 18, 1997 · N973DL · Doug MD88SDR 9713839603Slide · failed testDURING PERIODIC CHECK, MAIN CABIN DOOR EVACUATION SLIDE FAILED BATTERY TEST. REPLACED SLIDE.Jul 16, 1997 · N603NW · Doug DC932SDR ASAA9780145Inflation Bottle · low pressureONT - PRIOR TO DEPARTURE OF FLIGHT 383, CREW REPORTED, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE L1 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)Jul 14, 1997 · N948AS · Doug DC983SDR MWEA97632Evac Slide · failedDURING C-CHK, GALL DOOR EVAC SLIDE FAB DETERIORATED. MAINT REMOVED AND REPLACED SLIDE.Jul 12, 1997 · N501ME · Doug DC932SDR 97ZZZM870Slide · deployedFUNCTION CHECK SLIDE (BELOW) AND THEN REMOVE FOR DETAILED INSPECTION REF CHECK LS. REPORT TASK ON STEP 543 IN COMPUTER. AT INSTALLATION C/W COVER LATCH PULL CHECK COMPLIED WITH FUNCTION CHECK NR 3 POS (S/N 0389) SLIDE ASSEMBLY AND REMOVED FOR DETLD INSPECTIOJul 10, 1997 · N463AP · Bag BAE146100ASDR 9713569953Slide · failed testDURING PERIODIC CHECK, MAIN CABIN DOOR EMERGENCY EVACUATION SLIDE FAILED BATTERY TEST. REPLACED SLIDE.Jul 10, 1997 · N918RW · Doug DC931SDR USAAD97115Slide · malfunctionedPIT/RON - TAIL CONE ACCIDENTALLY DROPPED, ESCAPE SLIDE DID NOT DEPLOY. REPLACED ESCAPE SLIDE. (X)Jul 1, 1997 · N816US · Doug DC982SDR CALA9701114Slide · low pressureINSPECTION FOUND THE TAILCONE EMERGENCY SLIDE PRESSURE LOW. THE TAILCONE SLIDE WAS REMOVED AND REPLACED IAW MM 25-62.Jun 29, 1997 · N937MC · Doug DC982SDR 9712539994Slide · failed testDURING PERIODIC CHECK, MAIN CABIN DOOR EVACUATION SLIDE FAILED BATTERY TEST. REPLACED SLIDE.Jun 25, 1997 · N8979E · Doug DC931SDR ASAA9780116Cable · brokenSEA - DURING MAINTENANCE CHECK, THE L1 DOOR EMERGENCY EVACUATION SLIDE GIRT BAR ATTACH CABLE WAS FOUND BROKEN. REPLACED THE CABLE ASSEMBLY. (M)Jun 20, 1997 · N957AS · Doug DC982SDR SWAA970556Slide · out of dateDURING SCHEDULED A1 CHECK, FOUND FWD SERVICE DOOR SLIDE OUT OF DATE. REMOVED AND REPLACED SLIDE PER BOEING M/M.Jun 19, 1997 · N301SW · Boeing 7373H4SDR 97UAL900470Slide · fell offCATERERS PARTIALLY OPENED DOOR FOUR RIGHT, WITH DOOR ARMED, CAUSING SLIDE TO FALL OFF. *S/D* 757 HAS AN EMERGENCY ASSIST CYLINDER TO OPEN DOOR IN EMERGENCY (WITH SLIDE ARMED). AMIS WRITE UP IMPROPERLY REPORTED PARTIAL OPENING OF DOOR. SLIDE WAS BLOWN AND OJun 15, 1997 · N570UA · Boeing 757222SDR 97UAL900625Valve · failedEVACUATION SLIDE AT DOOR 4R INFLATED IN THE AIRPLANE DUE TO INFLATION BOTTLE DISCHARGE VALVE FAILURE. THE AIRPLANE HAD BEEN STORED IN LAS FOR 32 MONTHS. IT WAS NOT ECONOMICALLY FEASIBLE TO REPAIR THE SLIDE DUE TO THE DAMAGE THAT OCCURRED DURING DEPLOYMENT. Jun 10, 1997 · N1808U · Doug DC1010SDR AWXA9700333Slide · deployedL-1 DOOR SLIDE ACCIDENTLY DEPLOYED ON PUSHBACK. REMOVED AND REPLACED SLIDE ASSEMBLY.Jun 9, 1997 · N620AW · Airbus A320231SDR ASAA9780110Inflation Bottle · low pressureSEA - DURING MAINTENANCE CHECK, THE R1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE R1 DOOR EMERGENCY EVACUATION SLIDE. (M)Jun 8, 1997 · N948AS · Doug DC983SDR 9710819966Slide · battery failedDURING PERIODIC CHECK, FORWARD SERVICE DOOR EVACUATION SLIDE FAILED BATTERY TEST. REPLACED SLIDE.Jun 4, 1997 · N9330 · Doug DC931SDR AU970810Slide · faulty(AUS) NO3 MAIN ENTRY DOOR ESCAPE SLIDE DEFLATE DURING TEST - SUSPECT CAUSED BY TEARING OF THE FABRIC BY THE DOOR DUST SEAL PLASTIC RETAINER METAL CORNERMay 28, 1997 · Boeing 747338SDR 9710469607Slide · low batteryDURING PERIODIC CHECK, FOUND MAIN CABIN DOOR EVACUATION SLIDE BATTERIES LOW. REPLACED SLIDE.May 28, 1997 · N607NW · Doug DC932SDR 9710459607Slide · low batteryDURING PERIODIC CHECK, FOUND RIGHT FORWARD SERVICE DOOR EVACUATION SLIDE BATTERIES LOW. REPLACED SLIDE.May 28, 1997 · N607NW · Doug DC932SDR AALA970973Slide · low pressureRDU - DURING OVERNIGHT CHECK, FOUND FORWARD ENTRY DOOR SLIDE BOTTLE PRESSURE LOW. REPLACED FORWARD ENTRY DOOR EMERGENCY EVACUATION SLIDE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)May 26, 1997 · N295AA · Doug DC982SDR ORJA9772Slide · not securedUPON OPENING FORWARD PASSENGER DOOR, SLIDE FELL OUT OF CONTAINER. INSTALLED FORWARD PASSENGER SLIDE, IAW MM. (X)May 25, 1997 · N823RA · Doug DC982SDR 97UAL900423Slide · cutDURING SHOP OVERHAUL OF SLIDE REMOVED FROM DOOR 1R FOR TIME EXPIRATION, A CUT WAS FOUND ON THE SLIDING SURFACE. SLIDE/RAFT WAS SENT TO THE VENDOR FOR REPAIR.May 25, 1997 · N551UA · Boeing 757222SDR 97UAL900422Slide · damagedDURING SHOP OVERHAUL OF SLIDE REMOVED FROM DOOR 1L FOR TIME EXPIRATION, A HOLE ON THE LOWER TUBE NEXT TO THE RELIEF VALVE WAS FOUND. SLIDE SENT TO THE VENDOR FOR REPAIR.May 25, 1997 · N548UA · Boeing 757222SDR 9710249983Slide · low pressureDURING LINE MAINTENANCE INSPECTION, FOUND AFT EVACUATION SLIDE BOTTLE PRESSURE LOW. REPLACED SLIDE.May 25, 1997 · N983US · Doug DC932
Back to JASC 2565