JASC 2611
Service difficulty reports · 7,436
Reports filed under 2611 · Smoke Detection, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2611' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2611' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA9922Smoke Detector · malfuntionedFLT CI328 - MAIN DECK SMOKE DETECTOR (NR 1) RED WARNING LIGHT ILLUMINATED AND BELL SOUNDED AND NR 4 SMOKE DETECTOR (A) LIGHT INTERMITTENTLY FLASHED A FEW TIMES DURING THE FIRST THREE HOURS OF FLIGHT. THEY CAN ON AT THE SAME TIME AND WERE ONLY ON FOR A SHORT PSDR QXEA9900940Smoke Warning · activatedSEA- EN ROUTE, THE SMOKE WARNING WENT OFF FOR APPROXIMATELY 15 SECONDS THEN WENT OUT. MAINTENANCE PERFORMED A OPERATIONAL CHECK OF THE DETECTORS WITH NO DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE. NO PARTS REPLACED.SDR RAIA990439Smoke Detector · illuminatedFLT 5786 - ORD - LAV SMOKE LIGHT ILLUMINATED, THEN SMOKE APPEARED IN COCKPIT AND CABIN. MAINTENANCE REPLACED LAV SMOKE DETECTOR AND PERFORMED ENGINE RUNS. (M)SDR QXEA9900853Smoke Detector · malfunctionedSEA - LAV SMOKE DETECTOR SOUNDS INTERMITTENT ALARMS. MAINTENANCE PLACED ON MEL. REMOVED AND REPLACED SMOKE DETECTOR IN LAVATORY, OPERATIONAL CHECK NORMAL. CLEARED MEL.SDR MALA976437Smoke Detector · malfunctionedAT CRUISE ALTITUDE, CARGO SMOKE LIGHT ON CWP CAME ON, ACTIVATED NR 1 CARGO EXTINGUISHER, LIGHT WENT OUT. FOLLOWED QRH FOR CARGO SMOKE, AS PER QRH ACTIVATED BOTH CARGO EXTINGUISHERS, NR 1 FOLLOWED BY NR 2 BOTTLE, AFTER 5 MINUTES FIRED BECAUSE CARGO SMOKE ILLUMSDR HNAA9900049Smoke Detector · malfunctionedINTERMITTENT BAGGAGE BAY SMOKE WARNING LIGHT IN FLIGHT (CONFIRMED NO SMOKE). INSPECTED WIRING/CONNECTORS AT BOTH SMOKE DETECTORS. SYSTEM TESTS NORMAL.SDR COMA9960157Smoke Detector · malfunctionedCARGO SMOKE WARNING. REPLACED CARGO COMPARTMENT SMOKE DETECTORS.SDR HNAA9900048Smoke Detector · won't testBAGGAGE COMPARTMENT NR 2 SMOKE DETECTOR WILL NOT TEST. REPLACED SMOKE DETECTOR.SDR UIEA9919Smoke Detector · defectiveFLT CI326 - MAIN DECK SMOKE DETECTOR SECTION 1 GAVE TOW MOMENTARY FIRE WARNINGS. INSPECTED MAIN DECK AND DETERMINED WARNING TO BE FALSE. MAIN SMOKE DETECTOR REPLACED. OPERATIONAL CHECK NORMAL. (M)SDR HEEA061684Smoke Detector · failedSMOKE DETECTOR FAILED FUNCTION TEST.SDR QXEA9900546Smoke Detector · malfunctionPDX- ON APPROACH, MASTER WARNING LIGHT ILLUMINATED WITH SMOKE WARNING LIGHT (BAGGAGE COMPARTMENT) INTERMITTENTLY ILLUMINATED. MAINTENANCE REPLACED BOTH CARGO COMPARTMENT SMOKE DETECTORS, OPERATIONAL CHECKS GOOD.SDR QXEA9900547Smoke Detector · malfunctionPDX- VERY BRIEF AND INTERMITTENT MASTER WARNING LIGHT ILLUMINATED WITH SMOKE WARNING LIGHT. BAGGAGE SMOKE DETECTORS TEST OK. MAINTENANCE REPLACED NR 2 SMOKE DETECTOR, OPERATIONAL CHECKS GOOD.SDR PCAA9900006Smoke Detector · malfunctionedBDL -FLT 3781 BAGGAGE SMOKE WARNING LIGHT CAME ON WITH NO EVIDENCE OF SMOKE OR FIRE DURING CRUISE FLIGHT INTO BDL. MAINTENANCE INSPECTED, FOUND NO EVIDENCE OF SMOKE OR FIRE, FOUND THE NR 2 BAGGAGE SMOKE DETECTOR AT FAULT. DISBLED IT AND RELEASED AIRCRAFT UNDERSDR PCAA9900005Smoke Detector · failedACY - FLT3698: AIRCRAFT WAS EN ROUTE TO PHL WHEN A BAG BAY SMOKE WARNING LIGHT ILLUMINATED. THE CREW DIVERTED INTO ACY AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND FOUND NO EVIDENCE OF SMOKE OR FIRE. THEY FOUND THE NR 2 SMOKE DETECTOR AT FAULT. TSDR SWAA990540Detector · defectiveAIR TURNBACK DUE TO AFTER TAKEOFF, THE AFT LAV SMOKE ALARM WENT OFF. REMOVED AND REPLACED SMOKE DETECTOR PER MM.SDR HNAA9900039Smoke Detector · failedDURING CLIMB-OUT, SMOKE WARNING LIGHT ILLUMINATED SEVERAL TIMES. NO EVIDENCE OF FIRE OR SMOKE. ELECTRICAL SMELL FOUND IN BAG BAY WHEN DOOR WAS OPENED. REPLACED BOTH SMOKE DETECTORS P/N 30-231-3 NR 1, S/N 31832, NR 2 S/N 0015W.SDR SIMA990778Smoke Detector · false indicationXNA - FLT 3603 - DURING APROACH, THE CARGO SMOKE WARNING LIGHT ILLUMINATED. DISCHARGED BOTH FIRE EXTINGUISHERS. VERIFIED EVENT AS A FALSE WARNING. REMOVED AND REPLACED BOTH CARGO SMOKE DETECTORS IAW EMB-145 AMM 26-15-00. NO FURTHER DEFECTS NOTED. AIRCRAFTSDR QXEA9900499Detector · malfunctionPUW- SMOKE WARNING LIGHT ILLUMINATED SEVERAL TIMES DURING FLIGHT. INSPECTED AND FOUND NO EVIDENCE OF SMOKE IN CARGO COMPARTMENT. REPLACED BOTH SMOKE DETECTORS, OPERATIONAL CHECKS GOOD. (S/N OFF 0819) 166 HRS & 243 CYCLES (TSN).SDR MALA976396Smoke Detector · dirtyAVIONIC SMOKE MASTER WARNING AND WARNING LIGHT (CWP) ILLUMINATED IN FLIGHT, NO INDICATION OF FIRE, SMOKE OR HEAT. AIRCRAFT RETURNED TO DTW. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE CLEANED AVIONIC RACK SMOKE DETECTOR PER SF340A MM. ALL CHECKS GOOD.SDR SIMA990721Smoke Detector · false warningDFW - FLT 5054 - LAVATORY SMOKE ON CWP ILLUMINATED INFLIGHT. FLIGHT ATTENDANT FOUND THE LAVATORY WAS OCCUPIED, AND THE PERSON WAS REMOVED. AOM VOL 1 PROCEDURES WERE COMPLIED WITH. VERIFIED THE EVENT AS A FALSE WARNING. REMOVED AND REPLACED THE LAV SMOKE DESDR C2XA99BT008Smoke Detector · malfunctionedAFT SMOKE ILLUMINATED ON TAXI. REMOVED AND REPLACED AFT SMOKE DETECTION. OPS CHECK GOOD IAW ATR JIC 26-15-00. (M)SDR 99UAL900153Smoke Detector · failedFORWARD LAVATORY SMOKE DETECTOR SYSTEM INOPERATIVE. FORWARD LAVATORY SMOKE DETECTOR UNIT REPLACED.SDR SIMA990691Smoke Detector · malfunctionedDSM - FLT 4017 - ON APPROACH BAGGAGE SMOKE WARNING LIGHT ILLUMINATED. DISCHARGED BOTH FIRE EXTINGUISHERS. DECLARED EMERGENCY. LANDED SAFELY. DETERMINED TO BE A FALSE WARNING. DEFERRED BAGGAGE SMOKE WARNING SYSTEM. PERFORMED OPERATIONAL CHECK OF BAGGAGE SSDR QXEA9900495Detector · malfunctionedPDX- SMOKE WARNING LIGHT ILLUMINATED INTERMITTANTLY. MAINTENANCE REPLACED BOTH CARGO COMPARTMENT SMOKE DETECTORS, OPERATIONAL CHECKS GOOD.SDR RAIA990304Smoke Detector · failedFLT 7461 - BHM - MAIN CARGO BAY SMOKE LIGHT ILLUMINATED. MAINTENANCE REPLACED MAIN CARGO BAY SMOKE DETECTOR. (M)SDR HNAA9900034Detector · intermittantSMOKE WARNING ILLUMINATED IN FLIGHT. NO APPARENT CAUSE. COULD NOT DUPLICATE. REPLACED NR 2 (FORWARD) SMOKE DETECTOR AS A PRECAUTION.SDR GAIA9931Bulb · failedEN ROUTE FROM YIP TO HUF, THE CARGO SMOKE LIGHT ILLUMINATED. THE FLIGHT CREW FOLLOWED EMERGENCY CHECKLIST PROCEDURES. THERE WAS NO SMOKE OR SMELL INTHE COCKPIT OR THE CARGO COMPARTMENT. LIGHT EXTINGUISHED 15 MINUTES LATER. ALL TEST WERE GOOD. THE AIRCRAFT SDR 99ZZZX1146Smoke Detector · malfunctionedEN ROUTE TO SDF, APPROXIMATELY 10 MINUTES FROM LANDING, THE FORWARD SMOKE CWP LIGHT CAME ON. THE CAPTAIN INSTRUCTED THE F/O TO DISCHARGE THE FORWARD HAND HELD FIRE EXTINGUISHER BOTTLE INTO THE FORWARD COMPARTMENT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THERESDR 99ZZZX1145Smoke Detector · malfunctionedEN ROUTE TO SDF, APPROXIMATELY 10 MINUTES FROM LANDING, THE FORWARD SMOKE CWP LIGHT CAME ON. THE CAPTAIN INSTRUCTED THE F/O TO DISCHARGE THE FORWARD HAND HELD FIRE EXTINGUISHER BOTTLE INTO THE FORWARD COMPARTMENT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THERESDR QXEA9900420Wire · brokenPDX- AFT SMOKE DETECTOR LIGHT STAYS ON. MAINTENANCE REPAIRED BROKEN WIRES 2612-4A22 AT CONNECTION 2612-P2. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. NO PARTS REPLACED.SDR DLL10990389Wire · brokenGALLEY SMOKE WARNING LIGHT ILLUM INTERMITTANTLY. AURAL WARNING DOES NOT ACTUATE, ALL OVENS OFF. SMOKE DETECTOR C/B PULLED. REPLACED SMOKE DETECTOR AND AMPLIFIER.SDR QXEA9900312Detector · malfunctionPDX- SMOKE LIGHT FLASHED ON AND OFF IN FLIGHT, AND THEN WENT OUT. MAINTENANCE INSPECTED AND FOUND NO EVIDENCE OF SMOKE OR FLAMES. REPLACED BOTH THE NR 1 AND NR 2 SMOKE DETECTOR IN THE CARGO COMPARTMENT, OPERATIONAL CHECKS GOOD.SDR CA990226007Smoke Detector · failed(CAN) AFT BULKHEAD SMOKE WARNING ILLUMINATED, AIRCRAFT SAFELY LANDED. INVESTIGATION REVEALED CONDENSATION IN SMOKE DETECTOR DUCT LEADING TO FAILURE OF UNIT.SDR EISA99029Smoke Detector · malfunctionedDURING CRUISE, CARGO SMOKE LIGHT ILLUMINATED WITH NO SECONDARY INDICATIONS OF SMOKE. GROUND TEST OF SYSTEM CHECKS GOOD. FOUND MOISTURE ON WALLS AND TWO VENT TUBES BENT. REPOSITIONED GROUND TEST GOOD. (M)SDR EISA99023Smoke Detector · malfunctionedCARGO SMOKE LIGHT ILLUMINATED IN FLIGHT NO OTHER INDICATIONS OF SMOKE, LIGHT WENT OUT AFTER 10 MINUTES. PERFORMED FUNCTIONAL CHECK OF CARGO SMOKE DETECTOR. (M)SDR SIMA990422Detector · false warningDFW - FLT 3576 - CARGO SMOKE LIGHT CAME ON IN FLIGHT. VERIFIED EVENT AS A FALSE WARNING. REMOVED AND REPLACED AFT CARGO SMOKE DETECTOR. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99FDEA00057Smoke Detector · malfunctioned99-0045, MAIN CARGO SMOKE IND LIGHT CAME ON FOR ZONE NR 6 FOR 30 SEC. REMOVED AND REPLACED DETECTOR NR 6 PER 727-200 MM 26-16-011-4. OPER CK GOOD.SDR GAIA9923Detector · dirtyEN ROUTE FROM MHR-TOL, THE CARGO SMOKE DETECTION CARGO LIGHT ILLUMINATED. THE AIRCRAFT DECLARED AN EMERGENCY AND DIVERTED TO SLC. THE AIRCRAFT LANDED WITHOUT ANY FURTHER DIFFICULTIES. FOUND CONDENSATION ON SMOKE DETECTORS IN THE MAIN CARGO BAY. CLEANED OFFSDR SCNA99031Smoke Detector · inopDURING A LINE MAINTENANCE CHECK, THE AFT RIGHT LAVATORY SMOKE DETECTOR ALARM WAS FOUND TO OPERATE CONTINUOUSLY. REMOVED AND REPLACED THE RIGHT AFT LAVATORY SMOKE DETECTOR, OPERATIONALLY CHECKS GOOD.SDR HNAA9900024Connector · dirtySMOKE WARNING LIGHT ILLUMINATED FOR 3-4 SECONDS ON SHORT FINAL, AFTER LANDING AND DURING ROLLOUT FOR 3-4 SECONDS. POST FLIGHT INSPECTION FOUND NO SMOKE OR FUMES IN BAG BAY. CLEANED CANNON PLUGS ON BOTH SMOKE DETECTORS IN BAG BAY. TESTED OPERATIONAL CHECK OKSDR DHL99742001Smoke Detector · defectiveAT FL 330 CARGO SMOKE WARNING LIGHT ILLUMINATED. DECLARED EMERGENCY AND DESCENDED INTO IAH. AT APPROX 2000 FT AGL THE LIGHT EXTINGUISHED. LANDED WITHOUT INCIDENT. FOUND NR 1 SMOKE DETECTOR DEFECTIVE. REMOVED AND REPLACED SMOKE DETECTOR.SDR QXEA9900283Wire · brokenSEA- SMOKE WARNING LIGHT CAME ON INTERMITTENTLY FOR ABOUT 5 SECONDS EACH TIME. MAINTENANCE INSPECTED AND FOUND NO EVIDENCE OF FIRE OR SMOKE. FOUND 2 BROKEN WIRES AT THE CANNON PLUG ON THE NR 2 CARGO SMOKE DETECTOR. STOWED WIRES AND PLACED ON MEL.SDR MALA976325Smoke Detector · malfunctionedAVIONICS SMOKE ILLUMINATED DURING FLIGHT, CREW COMPLETED QRH. MAINTENANCE COULD NOT DUPLICATE. REMOVED AVIONICS DOOR AND INSPECTED AREA FOR SMOKE AND EVIDENCE FOR OVERHEAT, NOTHING NOTED. NO SMELL OF SMOKE. PERFORMED SMOKE DETECTOR TEST IAW 26-13-00.SDR MALA976320Connector · looseCARGO SMOKE LIGHT ILLUMINATED ON THE GROUND, NO INDICATION OF SMOKE, DUST ETC IN CARGO HOLD. MAINTENANCE CLEANED AND RESECURED FORWARD SMOKE DETECTOR CANNON PLUG, OPS CHECK GOOD.SDR AWXA9900031Smoke Detector · dirtyAFT LAV SMOKE WARNING, INITIATED AIR RETURN TO MIA. CLEANED OUT CLOGGED AFT LAV DETECTOR GRILLS. ALSO, CHECKED REPORT OF THE SIDE WALL BEING HOT, THIS WAS NORMAL AS THE HOT WATER HEATER IS ON THE OTHER SIDE. NO PARTS REPLACED.SDR HNAA9900016Smoke Detector · malfunctionedSMOKE WARNING LIGHT ILLUMINATES INTERMITTANTLY IN FLIGHT. COULD NOT DUPLICATE. REPLACED ANNUNCIATOR PANEL (P/N 75-0434-1) (S/N 0075), SMOKE DETECTOR (P/N 473054) (S/N 0052) AND SMOKE DETECTION CONTROL AMPLFIER (P/N 30-326E7) (S/N 0354) AS A PRECAUTION.SDR COMA9960038Smoke Detector · malfunctionedCARGO SMOKE WARNING, BOTTLES DISCHARGED. FALSE WARNING. REPLACED FIRE BOTTLES AND SMOKE DETECTORS.SDR COMA9960037Smoke Detector · malfunctionedCARGO SMOKE WARNING, FIRE BOTTLES DISCHARGED. FALSE WARNING. REPLACED FIRE BOTTLES AND SMOKE DETECTORS.SDR AWXA9900020Smoke Detector · damagedECAM SMOKE LAVATORY DET FAULT, SUSPECT LAV (AFT LEFT). A/C RETURNED TO LAS VEGAS. DETECTOR TAMPERED WITH BY PASSENGER. PLACED ON MEL 26-17-01, LOCKED OUT LAV. REMOVED AND REPLACED DETECTOR IN LAV D PER AMM CHAP 26, SYS CKS OK THROUGH CFDS.SDR EISA99003Smoke Detector · inoperativeDURING CRUISE CARGO SMOKE DETECTOR ILLUMINATED WITH NO EVIDENCE OF SMOKE, LIGHT REMAINED ON WITH DOOR OPEN ON GROUND. REMOVED AND REPLACED NR 1 SMOKE DETECTOR. SYSTEM OPS CHECKS GOOD PER MM 26-17-0. (M)
Back to JASC 2611